AV90 Advocate Lavatory System AV-Series

Similar documents
AV60 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

AV30 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

SS-3N Express Lavatory System SS-Series

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

SS-2N Express Lavatory System SS-Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

LD-5010 OmniDeck with WashBar 5000 Series

FL-3H, FL-3L Frequency Lavatory System FL-Series

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

Express Lavatory System MG-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

Express Lavatory System MG-Series

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

LVQD3 Verge with WashBar Technology LVQ-Series

LVQD3 Verge with WashBar Technology LVQ-Series

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

LVQD1 Verge with WashBar Technology LVQ-Series

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

LVSD2 Verge Wash Basin LVS-Series

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

LVSD2 Verge Wash Basin LVS-Series

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

Model Z Sundara Reef Triple Basin Hand Washing System

Washfountain Application Guide

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

LA60 DISCONTINUED IMPORTANT!

Installation Instructions OBSOLETE

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

MERIDIAN MODEL# 3793

LA45 DISCONTINUED IMPORTANT!

School Solutions Ideabook

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

Model Z Sundara Float Double Basin Hand Washing System

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

LA90 DISCONTINUED IMPORTANT!

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Terreon Lav Decks WARNING

A. Section Joint Sealants: Seal fixtures to walls and floors.

PAT BASIN MODEL 9121, 9131, & 9141

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

ADA guidelines. 48" min. 30" min. 8 min. 34 max. to top of lavatory rim. 27 min. knee space to bottom of bowl

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

D & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.

Summary of Substantive Changes between the 2012 and 2018 editions of ASME A /CSA B125.1 Plumbing Supply Fittings

HOT WATER WITH THE SNAP OF A FINGER. Mini Tanks. Basic Heaters. High Capacity Heaters. Model CMT. Model SR, M & E. Model ER Series

Union County Vocational - Technical Schools Scotch Plains, New Jersey

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

Commercial washroom innovation. 90 years as the leading source of innovative solutions for all washroom design challenges. bradleycorp.

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

COMMERCIAL VOLUME PLUMBING

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

Durability within reach

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

Transcription:

Soap, water and hand dryer, unique all-in-one patent pending design Includes infrared, high speed, dual-sided hand dryer at each hand washing station Includes large capacity, top-fill, infrared soap dispenser, with low level indicator and one-of-a-kind overfill protection Includes hygienic hands-free infrared,.38gpm faucet Constructed of Terreon Solid Surface Material Soap, faucet and dryer are pre-mounted to basin Meets International Codes & Standards Specifications The Advocate Lav System s unique all-in-one design allows users to access soap, water and a hand dryer without leaving the hand washing station. This provides personal space and helps to prevent water from dripping off hands and on to the floor, making cleaning and maintenance easier while providing a safer restroom environment. The AV-Series features a solid surface one-of-a-kind integral bowl. This system can be mounted at different heights to accommodate hand washing for adults, children, young children and those with disabilities. Construction owl Constructed of Terreon, a densified solid surface material composed of bio-based resin or Terreon RE, a densified solid surface material composed of a bio-based resin and preconsumer recycled granules. Terreon and TerreonRE are resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Access Panel The access panel of the Advocate lav system not only conceals plumbing and electrical connections, but also reduces time needed for installation and maintenance. Access panel is made from Class A fire-rated polystyrene. Access panel color: Coal. End Panel The end panels are deep drawn 18 gauge stainless steel. Stainless steel is polished 300 series with a #3 finish. End panels have internal stud welds for mounting to stainless steel frame described below. Mounting Frame The AV-Series includes welded 18 gauge stainless steel mounting frame with 14 gauge basin supports, eliminating the need for additional specifications and/or casework to support the fixture. All Advocate Lavatory Systems meet or exceed industry standards for load testing. Faucet The faucet sensor uses a collimated infrared transmitting beam as part of a position sensor to detect hands. Range is 4". This creates a specific detection area near the faucet spout. Sensor activates when the user s hands enter the detection area. A timing turn-off delay of 2 3 seconds results in a smooth, controlled hand-washing operation. To ensure proper activation, lighting can not exceed 10,000 lux. The radley sensor is not affected by varying skin tones or darkness. The flow is a spray pattern at a rate of.38 gpm. Low Voltage Plug-In Adapter A UL/CSA-listed 120VAC/12VDC or 230/24 VAC, plug-in adapter powers the solenoid valve. The adapter, furnished as standard equipment, plugs into a standard GFCI protected electrical outlet. Protected by one or more of the following patents: D663,016; D674,967. Other patents pending. Model AV90 Valve 12VDC, 3 8" NPT electronically-activated, slow-closing solenoid valve provides reliable performance since there are few moving parts, and its operation is unaffected by most chemicals and minerals often present in municipal water supplies. Operating water pressure range is 20 80 psi. Flow regulator keeps flow rate constant at all pressures. Soap Dispenser Each hand washing station features an electronic liquid soap dispenser within the basin area. This eliminates any soap from dripping on counters or onto the floor, minimizing slip hazards and easy cleaning. Each dispenser features an integral check valve to hold prime for consistent reliable operation. Dispenser is top filled via a tamper resistant flip top cover accessed using a spanner wrench (included). Dispenser is compatible with most liquid soaps. Soap tank capacity is 64oz. (1893ml). The Advocate soap dispenser features built in-overflow protection utilizing an audible chirp that increases in intensity when soap level approaches full. Soap level indicator flashes red when soap is low. The sensor uses a collimated infrared transmitting beam as part of a position sensor to detect hands. Sensor activation range is 2". Intelligent electronics allow a maximum of three activations in a 15-second period, limiting the rate at which soap can be dispensed, preventing waste and deterring vandalism. Sensor can be activated at start up to automatically prime soap dispenser. Hand Dryer Each hand washing station features an individual infrared-activated, energy efficient hand dryer. Dryer can be entered from the side immediately after washing hands. This virtually eliminates excess water on the floor. The one-of-a-kind dual-sided dryer features white LEDs to illuminate the dryer cavity while in stand-by mode, and amber LEDs while dryer is active. Dryer sensors can be turned off for 30 seconds while cleaning dryer area. The sensor uses a collimated infrared transmitting beam as part of a position sensor to detect hands. Range is 4". The dual-sided dryer will dry hands in approximately 15 seconds. The dryer nozzles contain antimicrobial protection that inhibits the growth of microorganisms such as bacteria, mold, mildew, and fungus. Dryer motor, located inside the cabinet of the Advocate, has 3' power cord that plugs into a standard 20-amp, 120-volt outlet or 10-amp outlet for the 230-volt model. Easily accessible filter housing uses standard rigid polyester replacement air filters. Dryer has an on/off disconnect switch. Dryer must be unplugged for any service. Hand dryer requires a dedicated 20 amp circuit or 10-amp outlet for the 230-volt model, and must be properly grounded. GFI circuit protection is recommended. Hand dryer is UL listed. AV Dryer Option Code Voltage/ Hz Watts Amps Circuit Required (Amps) CFM d Plug Type HD2 120/60 1150 12 20 69 80 HD3 230/50 1150 8.6 10 70 80 F HD4 230/50 1150 8.6 10 70 80 G Page 1 of 8 5/31/2017 radley_sink_advocate_av90 2017 radley P.O. ox 309, Menomonee Falls, WI 53052-0309 800 RADLEY (800 272 3539) +1 262 251 6000

Code Compliance and Certifications Electrical Safety - United States and Canada UL 507 Electric Fans CSA C22.2 no. 113-10 Fans and Ventilators UL 60730-1 Electrical Controls for Household and Similar Use, Part 1: General Requirements. CSA-E60730-1-02, Automatic Electrical Controls for Household and Similar Use - Part 1: General Requirements FCC Part 15 Subpart Class A Electrical Safety - Europe IEC 60730-1 Automatic Electrical Controls for Household and Similar Use - Part 1: General Requirements IEC 60335-1 Household and Similar Electrical Appliances Safety Part 1: General Requirements - Edition 4 - Revisions Date 2004/03/01 IEC 60335-2-23 Household and Similar Electrical Appliances - Safety Pt. 2-23, Particular Requirements for Appliances for Skin or Hair Care - Edition 5.2 - Issue Date 2012/03/01 EN 61000-3-2 Harmonic Current Emissions EN 61000-3-3 Limits - Limitation of Voltage Changes, Voltage Fluctuations and Flicker in Public Low-Voltage Supply Systems, for Equipment with Rated Current 16A per Phase and not Subject to Conditional Connection EN 61000-6-2 Generic Standards - Immunity for Industrial Environments EN 61000-6-4 Generic Standards - Emission Standard for Industrial Environments EN62233: 2008 Measurement Measurements for Electromagnetic Fields of Household Appliances and Similar Apparatus with Regard to Human Exposure Plumbing - United States and Canada CSA 45.0 General Requirements for Plumbing Fixtures 45.5/IAPMO Z124 Plastic Plumbing Fixtures ASME A112.18.1-2011/CSA 125.1-11 Plumbing Supply Fittings ASME 1070-2004 Performance Requirements for Water Temperature Limiting Devices IAPMO IGC 156 Washfountains and Lavatory Systems with or without Water Closets NSF/ANSI 372-2011 Drinking Water System Components - Lead Content Plumbing - Europe EN 14688 Washbasins. Functional Requirements and Test Methods EN 695 Kitchen Sinks. Connecting Dimensions EN 31 Washbasins. Connecting Dimensions Solid Surface - United States and Canada CSA 45.5/IAPMO Z124 Plastic Lavatories - Home Innovation Lab Certified ASTM E84 Surface urn Characteristics - Rated Flame Class A GREENGUARD Certified as low emitting materials. AV90 Solid Surface - Europe DIN ISO 4586-2: 07-1997 High-Pressure Decorative Laminate Sheets Made from Thermosetting Resins - Part 1: Classification and Specifications DIN EN 438 - Part 1 1991 High-Pressure Decorative Laminates (HPL). Sheets ased on Thermosetting Resins (Usually Called Laminates). Classification and Specifications for Alternative Core Laminates DIN EN13501-1 Fire Classification of Construction Products and uilding Elements - Part 1: Classification Using Data from Reaction to Fire Tests Rated -s1, d0 Standard Height Mounting The standard height hand washing stations are designed to be mounted with a 34" rim height to comply with all ADA guidelines on reaches and clearances. Juvenile Height Mounting The juvenile height hand washing stations are designed to be mounted at 31" rim height to comply with all ADA guidelines, and ANSI A117.1 standard, for reaches and clearances. Source: ADA Accessibility Guidelines for uildings and Facilities (ADAAG) as amended through August 5, 2005. Junior Height Mounting The Junior Height option is designed to be mounted at a 26" rim height for use by younger children where ADA guidelines are not a concern. Hand Dryer The Advocate Lavatory System hand dryer meets requirements for safety as listed by Underwriters Laboratories, Inc. This plumbing fixture is designed for hand washing only. It is not Intended to dispense water for human consumption through drinking or for preparation of food or beverages. Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ ANSI 372 meeting the Lead-Free content requirement. Standard Equipment AV90 Advocate lavatory system features three hand washing stations with hands-free.38gpm flow faucets, soap dispensers and three hand dryers. These components are composite fiberglass, reinforced polymer with a painted, clear coat finish. End panels are satin finish 300 series stainless steel. Heavy gauge stainless steel mounting system. Trap cover is easily removed for service and encloses the following fittings: offset drains; P-traps; flexible stainless steel supply connections; and ASSE 1070 Navigator thermostatic mixing valve with combination stop/strainer/check valves. Certified to NSF/ANSI 372 Page 2 of 8 5/31/2017 radley_sink_advocate_av90 2017 radley P.O. ox 309, Menomonee Falls, WI 53052-0309 800 RADLEY (800 272 3539) +1 262 251 6000

Dimensions for AV-Series Advocate Lavatory Systems Top View 4 3 8" (111mm) 12 5 8" (321mm) 5¼" (133mm) 90" (2286mm) 13 3 8" (340mm) 11⁵ ₈" (295mm) 17" (432mm) 19" (483mm) 15½" (394mm) 27½" (699mm) 48" (1219mm) min. ADA Clear floor space (for each station) Front View 90" (2286mm) min. ADA 45" (1143mm) 45" (1143mm) 3" (76mm) 20 5 8" (524mm) 36 3 8" (924mm) Page 3 of 8 5/31/2017 radley_sink_advocate_av90 2017 radley P.O. ox 309, Menomonee Falls, WI 53052-0309 800 RADLEY (800 272 3539) +1 262 251 6000

Dimensions for AV-Series Advocate Lavatory Systems Standard Height 40" (1016mm) * 33¼" (845mm) 36¼" (921mm) 38¼" (972mm) 17½" (445mm) 9" (229mm) * 27" (686mm) * 32" (813mm) 34" (864mm) * 6" (152mm) * 17" (432mm) min. 8" (203mm) * Juvenile Height Junior Height 37" (940mm) * 35¼" (895mm) 14½" (368mm) 9" (229mm) * 24" (610mm) * 29" (737mm) 30¼" (768mm) 31" (787mm) * 33¼" (845mm) 30¼" (768mm) 9 5 8" (244mm) 24" (610mm) 25¼" (641mm) 26" (660mm) 28¼" (718mm) 6" (152mm) * 17" (432mm) min. 8" (203mm) * * ADA AA Guidelines, 2004; Chapter 6: Plumbing Elements and Facilities; 606.3 Height Page 4 of 8 5/31/2017 radley_sink_advocate_av90 2017 radley P.O. ox 309, Menomonee Falls, WI 53052-0309 800 RADLEY (800 272 3539) +1 262 251 6000

Dimensions for AV-Series Advocate Lavatory Systems TAS Height Grades 6 through 8 or 9 37" (940mm) 36¼" (921mm) 15½" (394mm) 9" (229mm) 28" (711mm) 31¼" (794mm) 32" (813mm) 34¼" (870mm) 6" (152mm) 17" (432mm) min. 8" (203mm) TAS Height Grades Pre-K through 5 or 6 34¼" (870mm) 34" (864mm) 13½" (343mm) 9" (229mm) 29¼" (743mm) 28" 26" (711mm) (660mm) 32¼" (819mm) 6" (152mm) 17" (432mm) min. 8" (203mm) Page 5 of 8 5/31/2017 radley_sink_advocate_av90 2017 radley P.O. ox 309, Menomonee Falls, WI 53052-0309 800 RADLEY (800 272 3539) +1 262 251 6000

Rough-Ins (hot/cold, drain, electrical, and valve) for AV90 Advocate Lavatory Systems (standard height shown) 41¾" (1060mm) (electrical) 35½" (902mm) 12¼" 6½" (311mm) (165mm) 90" (2286mm) 5½" (140mm) 24½" (622mm) Frame Centerine Notch E D F F D E D E 19" (483mm) 25¾" (654mm) (3) places 24" (610mm) (3) places) 20¼" (514mm) 2½" (64mm) H C 26½" (673mm) 34¹ ₈" (867mm) 10¼" (260mm) (electrical) 40¼" (1022mm) (electrical) C L Finished Floor 17⁵ ₈" (448mm) 36⁵ ₈" (930mm) CODE DESCRIPTION QTY. H, C ½" nominal (⁵ ₈" O.D. Comp.) Hot/Cold Supplies, Stub-Out 2" (51mm) From Wall 1 D 1½" NPT Drain, Stub-Out 2" (51mm) From Wall 3 E 20-amp, 120-volt GFI Protected Electrical Outlet or 10-amp minimum circuit required for 230V (based on product selections) Circuit breaker to have a minimum instantaneous overload current rating of 6 times the circuit breaker's ampere rating. F #10 Anchors for Valve racket Installation 2 RIM HEIGHT VERTICAL HEIGHT ADJUSTMENTS FOR CODES A,, H, C, D and E 34" (864mm) No Adjustment Standard 31" (787mm) Subtract 3" (76mm) Juvenile 26" (660mm) Subtract 8" (203mm) Junior 32" (813mm) Subtract 2" (51mm) TAS Grades 6 through 8 or 9 Subtract 4" (102mm) TAS Grades Pre-K through 5 or 6 FIXTURE STYLE 3 Page 6 of 8 5/31/2017 radley_sink_advocate_av90 2017 radley P.O. ox 309, Menomonee Falls, WI 53052-0309 800 RADLEY (800 272 3539) +1 262 251 6000

acking Rough-Ins for AV90 Advocate Lavatory Systems (standard height shown) AV90 Areas marked as Anchor hardware is not provided. require sufficient backing compliant with local building site codes. 11¾" (298mm) 30⁵ ₈" (778mm) ⁵ ₈" (16mm) 90" (2286mm) 11¾" (298mm) 29³ ₈" (746mm) 11¾" (298mm) A A A A A A 19" (483mm) 17⁵ ₈" (448mm) 15¾" (400mm) 14¼" (362mm) 38¾" (984mm) 8¾" (222mm) 15¾" (400mm) 14¼" (362mm) 15¾" (400mm) 9½" (241mm) (6) places 20¾" (527mm) (6) places 36¹ ₈" (918mm) (6) places Finished Floor C L CODE DESCRIPTION QTY. A ³ ₈" owl Anchors with a Minimum Pull-Out Force of 1,000 lbs. 6 ³ ₈" Frame Anchors with a Minimum Pull-Out Force of 1,000 lbs. 12 RIM HEIGHT VERTICAL HEIGHT ADJUSTMENTS FOR CODES A,, H, C, D and E 34" (864mm) No Adjustment Standard 31" (787mm) Subtract 3" (76mm) Juvenile 26" (660mm) Subtract 8" (203mm) Junior 32" (813mm) Subtract 2" (51mm) TAS Grades 6 through 8 or 9 Subtract 4" (102mm) TAS Grades Pre-K through 5 or 6 FIXTURE STYLE Page 7 of 8 5/31/2017 radley_sink_advocate_av90 2017 radley P.O. ox 309, Menomonee Falls, WI 53052-0309 800 RADLEY (800 272 3539) +1 262 251 6000

Model AV90 Advocate Lavatory System AV-Series Standard Selections (Must select one from each category) Activation Type IRP Faucet Spout with Adaptive Infrared Soap Dispenser Type 1 Electronic Soap Dispenser Water Supply Type 2 Tempered Line 3 Navigator Thermostatic Mixing Valve Hand Dryer Type HD2 HD3 HD4 HD2 rushless DC Motor 120v/60hz, 20 Amp (Type "") rushless DC Motor 230v/50hz, 10 Amp (Type "F") rushless DC Motor 230v/50hz, 10 Amp (Type "G") HD3 HD4 Component Finish (Faucet, Soap, Dryer) VS Vapor Silver Color of Terreon owl (select one): Standard Colors CHAR COLE DRIFT DUNE E-GRAY GRAPH LANNON LONDON MOONSTONE Charcoal Gray Cobblestone Driftwood Sand Dune Empire Gray Graphite Lannonstone London Gray Moonstone O-TAUPE PELE PEP-WHT SAND S-CREEK S-MIST WHT-SAND Organic Taupe Pebble each Peppered White Sandtrap Stone Creek Silver Mist White Sand Element Colors SS-GRAY Soapstone Gray CA-TAN Canyon Tan Designer Colors * ARC-CHIP Arctic Chip COFFEE Coffee ean RIVER Riverstone TerreonRE Colors* IRCH-ARK irch ark MOONDUST Moondust DUSK Dusk OAT Oat Access Panel Type PD Waste Assembly Type D High Impact Polymer, Coal Chrome (Single) G Polypropylene (Single) * Designer and TerreonRE colors available at an additional charge (non-cancelable, non-returnable). This color contains large, randomly distributed chips. Page 8 of 8 5/31/2017 radley_sink_advocate_av90 2017 radley P.O. ox 309, Menomonee Falls, WI 53052-0309 800 RADLEY (800 272 3539) +1 262 251 6000