Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU. Típus EK-EU

Similar documents
Type EK-EU FOR MECHANICAL SMOKE EXTRACT SYSTEMS AND AS AN ADDITIONAL SUPPLY AIR INLET, ALSO FOR NATURAL SMOKE AND HEAT EXHAUST SYSTEMS

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Fire dampers. For diverse applications

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

K*, R* Ventilation grilles

Type RM-O-3-D. Duct smoke detector used to prevent smoke from spreading through the ducts of ventilation and air conditioning systems

Ceiling diffusers. Type DLQL

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Ceiling swirl diffusers

Ceiling swirl diffusers

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

BSK-RPR Fire Damper. Additional operating instructions according to

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

BKA-EN Fire Damper. Additional operating instructions according to

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT

Units for suspended ceilings

Dual certification! Air handling units for potentially explosive atmospheres

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Fire damper DESIGN GENERAL FIRE CELL DIVISION DISTRIBUTION OF RESPONSIBILITIES FIRE PROTECTION DOCUMENTATION HAGAB FIRE DAMPER DESIGN

Bevent Rasch BSKC6. - Fire /06/17

Smoke extraction duct of sheet steel

DUCT SMOKE DETECTORS IQ8

DACC Health Sciences Building Air Handler Assessment/Study

Air distribution for clean rooms. Clever and flexible.

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

TrueAlarm Analog Sensing

TUNNEL FANS STANDARD AND HOT SMOKE

Life Safety Dampers Selection and Application Manual

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

KOMFORT EC DB Suspended heat recovery air handling units

Intumescent Fire Dampers

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

DUCT SYSTEMS CHAPTER 6

Introduction to Fans. The Basics of Fan Principles and Terminology

Bevent Rasch RABC-VAV. - Fire /03/2018

Prescriptive Requirement for Smoke Control

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Units for suspended cei lings

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Installation of a Brunner fireplace. General Indications

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Fan Coil Unit CULTRA

European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Orion-Opus LØV-R with Sirius

CONTENT: VEX308 Decentralised ventilation VEX308

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

DUCT SYSTEMS CHAPTER 6

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Trench Heating Katherm QK

Colt International Ltd Commissioning and maintenance of smoke control systems CPD Technical Seminar

FEATURES AND BENEFITS

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

Control and Indicating Equipment

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Orion-PTV LØV-R with Sirius

Orion-LØV LØV-R with Sirius

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Module 7. Control of Smoke & Highlights of Code Requirements

PDH & Professional Training

Lo-Carbon Sentinel Kinetic Horizontal

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

NFPA Edition Update

COOLflow 4E PRODUCT RANGE

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

ADAPTER FOR VENTILATION DUCT BWP-143A-SS (STAINLESS STEEL)

Calm. Service Instructions

Installation Smoke Detector ELQZ , GOLD

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

FIRE AND SECURITY CONSULTING SERVICES

Homepage > Prodotti > Sistemi di ventilazione decentralizzata > Dispositivi verticali > Type FSL-V-ZUS. Type FSL-V-ZUS

PARAGON. Compact comfort module. Key figures

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Heat Recovery Unit (Aluminium Plate) Energy Recovery Unit (Rotary)

Transcription:

Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU Típus EK-EU FOR MECHANICAL SMOKE EXTRACT SYSTEMS AND AS AN ADDI TIONAL SUPPLY AIR INLET Rectangular smoke control dampers with extract ventilation function, for smoke extract with mechanical smoke extract systems or as an additional supply air inlet Nominal sizes 200 200 1500 800 mm, in increments of 1 mm Casing, damper blade and actuator encasing made of temperature-resistant calcium silicate Remote control with actuator Pressure level 3 (operating pressure 1500 to 500 Pa) Manual or automatic release For smoke extract ducts from 35 mm wall thickness Cmod = ventilation function and intermediate positions for flow rate balancing Casing air leakage to EN 1751, class C Optional equipment and accessories Connecting subframe Cover grille

Integration into the central BMS with TROXNETCOM APPLICATION Application Smoke control dampers of Type EK-EU, with CE marking and declaration of performance, for smoke extract with mechanical smoke extract systems Provision of fresh air supply for mechanical smoke extract systems Extract ventilation function is possible if the mechanical smoke extract system has been approved (general building approval) for extract ventilation Integration into the central BMS with TROXNETCOM Special characteristics Declaration of performance according to Construction Products Regulation Classification to EN 13501-4, EI 90 (vedw hodw, i o) S1500 Cmod MA multi General building inspectorate licence Z- 56.4212-990 Complies with the requirements of EN 12101-8 Tested for fire resistance properties to DIN 1366-10 and EN 1366-2 Casing air leakage to EN 1751, class C Low sound power level and differential pressure Any airflow direction Integration into the central BMS with TROXNETCOM Tested to EN 1366-10 with a weight being attached to the blade, with 10,000 open/close cycles and 10,000 cycles in intermediate position (Cmod)

DESCRIPTION Variants EK-EU with open/close actuator of Type BE EK-EU with cover grille Attachments Open/Close actuator, 24 V AC/DC or 230 V AC supply voltage Network module for the integration with AS-i networks Construction features Rectangular construction Reversible open/close actuator Remote control with actuator Suitable for the connection of cover grilles or connecting subframes Materials and surfaces Casing, damper blade and actuator encasing made of temperature-resistant calcium silicate Brass bearings Shafts made of stainless steel MŰSZAKI INFORMÁCIÓK FUNCTION Functional description Smoke control dampers are used in mechanical smoke extract systems. They are used for extracting smoke gases and for providing additional supply air to one or more fire compartments. The dampers are made of calcium silicate panels and are opened by an encased actuator; when smoke is detected, the actuator is triggered by a signal either from a duct smoke detector or from a fire alarm system. Smoke control dampers have two safety positions: open and closed. In the case of fire-resistant smoke control dampers for multiple compartments, the safety position is either 'open' or 'closed', depending on the fire site and the path of the smoke to be extracted. If the safety position is 'open', the free area must be maintained even in the event of a fire. According to the specified time- temperature curve, an EK-EU can still fully open or close after 25 minutes (MA, manual release). Regular maintenance of the smoke control damper is required to ensure its functional reliability.

TECHNICAL DATA SPECIFICATION TEXT Rectangular or square smoke control dampers to product standard EN 12101-8, tested to EN 1366-10 and EN 1366-2, for use in smoke extract systems. Smoke control dampers not only prevent the spreading of smoke and combustion products between fire compartments, they also prevent the leakage of emitted, dangerous and poisonous fire suppression gases from the affected area, and they maintain positive pressure in pressurisation systems. The EK-EU is suitable as a pressure relief damper for gas fire extinguishing systems. For extracting smoke gases and for providing additional supply air to one or more fire compartments. The EK-EU can be used in smoke extract systems which have been approved for extract ventilation. The fire-resistant smoke control damper for multiple compartments is suitable for installation in solid walls and ceiling slabs as well as in and on fire-resistant smoke extract ducts. Open/Close actuator, with fully wired and ready-to-operate control module AS- EM or AS-EM/SIL2 in a temperature resistant encasing (optional). Special characteristics Declaration of performance according to Construction Products Regulation Classification to EN 13501-4, EI 90 (vedw hodw, i o) S1500 Cmod MA multi General building inspectorate licence Z- 56.4212-990 Complies with the requirements of EN 12101-8 Tested for fire resistance properties to DIN 1366-10 and EN 1366-2 Casing air leakage to EN 1751, class C Low sound power level and differential pressure Any airflow direction Integration into the central BMS with TROXNETCOM Tested to EN 1366-10 with a weight being attached to the blade, with 10,000 open/close cycles and 10,000 cycles in intermediate position (Cmod) Materials and surfaces Casing, damper blade and actuator encasing made of temperature-resistant calcium silicate Brass bearings Shafts made of stainless steel Technical data

Nominal sizes: 200 200 mm 1500 800 mm, in increments of 1 mm Casing length: 600 and 800 mm Volume flow rate range: Up to 12000 l/s or 43200 m³/h Differential pressure range, pressure level 3: 1500 to 500 Pa Operating temperature: 30 to 50 C Upstream velocity*: 10 m/s * Data applies to uniform upstream and downstream conditions for the smoke control damper Sizing data [m³/h] Δpst [Pa] LWA Air-regenerated noise [db(a)] Kezdőlap Kapcsolat Impresszum Szállítási és fizetési feltételek Titoktartás Jogi nyilatkozat 2018.01.07. TROX Austria GmbH

Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU ORDER CODE Kezdőlap Kapcsolat Impresszum Szállítási és fizetési feltételek Titoktartás Jogi nyilatkozat 2018.01.07. TROX Austria GmbH

Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU TROX Austria GmbH Online szolgáltatások Szerviz forródrót TROX Academy Az Ön kapcsolattartója Online hibabejelentés TROX Austria GmbH Magyarországi Fióktelep Telefon +36 1 212 1211 Kapcsolat Magyarországi Fióktelep 1138 Budapest Népfürdő u.22.c.ép.fszt.3/b. Telefon +36 1 212 1211 Fax +36 1 212 0735 E-Mail trox@trox.hu Kezdőlap Kapcsolat Impresszum Szállítási és fizetési feltételek Titoktartás Jogi nyilatkozat 2018.01.07. TROX Austria GmbH