MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Similar documents
Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION ELECTRICAL GENERAL PROVISIONS

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

5. Identification products.

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

SECTION ELECTRICAL IDENTIFICATION

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Electricity Unit Notes. Agriculture Mechanics I

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS

Catalogue. Instrumentation & Control Cables

All surfaces shall be restored where surface finish damage is evident. Physical material damage will require replacement of part.

Catalogue Power Cables

Related Sections: TBD. Effective Date: January 1, 2016

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

A. Shop Drawing submittals shall include, but not be limited to, the following:

E I Delmar Cobble MINOR ELECTRICAL DEMOLITION

occurs and be cause for termination of the contract.

Chapter 1 General... 5

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

Division 26 ELECTRICAL TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

Flexible Power Cable DLO

SECTION (16075) - IDENTIFICATION FOR ELECTRICAL SYSTEMS

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

SECTION BASIC ELECTRICAL MATERIALS AND METHODS. A. This Section includes basic electrical materials and methods including:

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

DuraLife TM FPL. Installation Guide. UL 2196 Fire Rated Alarm Cables. Authorities Having Jurisdiction should be consulted before installation.

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

BASIC ELECTRICAL REQUIREMENTS July Electrical Systems

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CHAPTER 20 SERVICE EQUIPMENT

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

2014 National Electrical Code & NFPA 70E/Arc Flash

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT ELECTRICAL POWER AND TRANSMISSION INSTALLERS. Test Code: 5922 Version: 01

*REPORT OF THE MOTIONS COMMITTEE

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

Special Provision No. 683S28 December 2017

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

SECTION LOW VOLTAGE LIGHTING CONTROLS

Installing Protectowire Linear Heat Detector

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

Installation Manual. Electric Range LSC5622W / LSB5611S / LST5601S / LSC5633W LSC5674W / LSC5683W / LSB5682S / LST5651S. Website:

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

P-16 ENGINEER NO. DATE DESCRIPTION 1 01/19/2016 FOR CONSTRUCTION 2 03/11/2016 REVISION # 2 DRAWN BY: CHECKED BY: DATE: SCALE: DRAWING NUMBER

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

On-Call General Contractor Specifications University of Maryland College Park June 2013

Steel Pipe Sleeves: ASTM A 53/A 53M, Type E, Grade B, Schedule 40, galvanized steel, plain ends.

Second Revision No. 601 NFPA [ Section No [Excluding

ELECTRICAL POWER SYSTEMS

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Division 16 Electrical Equipment

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

Spring Test 6 due 04/26/2013

DIVISION 16. ElECTRICAl

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

3. Provide revised typed circuit directory in panelboards that have circuits removed.

SECTION GENERAL REQUIREMENTS, ELECTRICAL. B. Comply with all applicable Federal, State, and municipal laws and regulations.

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

SECTION FIRE ALARM SYSTEMS

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES

Tratos Railway Cables

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

NEC Study Guide CORRECT: C NEC (A)(1)

SECTION INTERCOMMUNICATIONS AND PROGRAM SYSTEMS

CONSOLIDATED EDISON CO. OF NEW YORK INC. 4 IRVING PLACE NEW YORK, N.Y DISTRIBUTION ENGINEERING CABLE SYSTEMS

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

ESTIMATE SET-UP PACKAGE BID SCHEDULE ENTRY AND MAINTENANCE

Transcription:

Related Sections U-M Design Guideline Sections: 260800 - Electrical Acceptance Tests Products Medium Voltage Primary Cables Primary power distribution cable shall be single conductor stranded copper, with ethylene propylene rubber (EPR) insulation rated 15kV, 90 degrees C, 133 percent insulation level, having a 5 mil thick minimum tape shield with 12-1/2 percent minimum overlap, and polyvinyl chloride (PVC) jacket. Cable shall be suitable for use on a 13.2 kv, 3 phase, 3 wire, ungrounded system. Cable shall be suitable for use in cable trays. Medium voltage service cables of voltages other than 13.2-kV (2.4kV, 4.8-kV) shall be of the type noted immediately above. The cable and terminations will be provided, and installed, to allow possible, future, conversion of the service to 13.2-kV. Medium voltage cables serving loads directly at voltages below 13.2-kV (2.4-kV, 4.16-kV. 4.8-kV) shall be single conductor stranded copper, with ethylene propylene rubber (EPR) insulation rated 5kV, 90 degrees C, 133 percent insulation level, and polyvinyl chloride (PVC) jacket. Cable shall be suitable for use on a 5 kv, 3 phase, 3 wire, ungrounded system. Cable shall be suitable for use in cable trays. Wires and Cables (600 Volts and Below) Power distribution and lighting wire for indoor use shall be single conductor stranded copper, No. 12 AWG minimum, with NEC Type THHN, or THHN/THWN-2 insulation rated 90 degrees C, 600 volts. Power distribution and lighting wire for outdoor use, for use in parking structures and tunnels, and for underground use in conduits shall be single conductor stranded copper, No. 12 AWG minimum, with NEC Type XHHW insulation rated 90 degrees C in dry locations and 75 degrees C in wet locations, 600 volts. Insulated power cable for use as fire pump supply cables shall be able to pass the two hour fire rated test under UL 2196 test (and shall be so labeled), be NEC Type MI rated 600-volts,and shall be one of the following types: 1. Mineral insulated, single conductor, solid copper conductor, using compressed magnesium oxide insulation, and shall have a liquid and gas tight seamless copper sheath. The cable is NEC Type MI. This cable is Factory Mutual (FM) approved, and MARCH 2014 PAGE 1 OF 5

may be used without need for a 'clearance from FM... Install and support as required by manufacturer and Code. 2. Ceramfied silicone insulated (Lifeline), single conductor, stranded copper conductor, cermafied silicone rubber insulated. The cable to be NEC Type RHH. This cable is not FM approved. FM must review each application before giving an approval for that project. Install cable in EMT, and install and support as required by manufacturer and Code Control wire shall be single conductor stranded copper, No. 14 AWG minimum, with NEC Type THHN, or THHN/THWN-2 insulation rated 90 degrees C, 600 volts. Instrumentation and special systems wire shall be in accordance with manufacturer s recommendations, but shall not be less than No. 20 AWG. Execution Medium Voltage Primary Cables Cables shall be pulled in lengths not exceeding 500 feet. Cables shall be pulled using generous amounts of compatible cable pulling lubricant. AE shall make calculations to insure maximum cable pulling tensions, sidewall pressures and cable bend radii do not exceed manufacturer s instructions. Cables passing through manholes shall be trained neatly in the same relative position as in the duct bank, without crossing each other, and shall be supported by porcelain or fiberglass insulators attached to manhole cable racks. Cables shall be identified by numbered tags. Identification numbers and tagging requirements shall be coordinated with the Plant Electric Shop through the Owner s Representative. Wires and Cables (600 Volts and Below) All wiring, including low voltage control, telecommunications, and power limited wiring shall be installed in raceways. (Raceways include conduits, ducts, trays, surface raceways, and wireways.) The only exceptions include: 1. NEC Type MI cable. 2. Control wiring at VAV boxes, serving sensors and actuators associated with that VAV box. 3. Type MC Cable serving light fixtures. 4. Type MC cable run in hollow wall cavities MARCH 2014 PAGE 2 OF 5

5. Manufacture prepared wiring systems associated with lighting fixtures. An example of this would be, Lithonia 'RELOC'. Said systems shall have a corrugated metal cover. Wiring of different voltage levels shall be segregated. Wiring of different voltage levels shall not share raceways (except wiring to rooftop receptacles, rooftop motor controls and motor disconnect early break auxiliary contacts may share raceways with motor feeders). Six hundred (600)-volt power feeder wiring shall be spliced with solderless compression butt splices or ring lugs and terminated with solderless compression ring lugs. Branch circuit wiring, lighting wiring, and control and instrumentation wiring shall be spliced with wire nut connectors. Control and instrumentation wiring shall be terminated with solderless compression ring or spade lugs. NEC Type MI cable shall be supported and protected in accordance with its manufacturer s instructions to maintain its UL fire resistive listing, and shall be spliced and terminated with special fittings from the same manufacturer as the cable. Home runs of 20 amp branch circuits that exceed 150 feet in length shall be No. 10 AWG wire. Home runs of 480 volt or 208 volt, 20 amp or 30 amp, single phase branch circuits that feed special receptacles shall be installed using 5 wires. Terminate the spare wires to ground at both ends. Cables and wires terminated in panels shall be uniquely identified by permanent tags. The shields of shielded instrumentation and control cables shall be grounded at one end only. The shields at the other end shall be insulated from ground. Color Coding All wiring shall be color coded, continuous color coded, or tape color coded at each termination and at each intervening 'box/point. 'If no color coding system exists, Campus circuits shall be color coded as follows: 1. Three Phase Power Over 600 Volts: MARCH 2014 PAGE 3 OF 5

2. Three Phase Power 480/277 Volts: Phase X(A): Brown Phase Y(B): Orange Phase Z(C): Yellow Neutral: Gray 3. Three Phase Power 208/120 Volts: 4. Single Phase Power 240/120 Volts: 5. Fire Alarm Wiring (Being updated and expanded for easier identification): Addressable Device: #18 Shielded Twisted Pair (STP) Red with Black Stripe Horn, Horn/Strobe or ZAM Positive (+) 24 VDC: #14 Red Horn, Horn/Strobe or ZAM Negative (-) 24 VDC: #14 Black Speakers: #18 STP Solid Red Strobe Light Positive (+): #14 Solid Yellow Strobe Light Negative (-): #14 Solid Blue Panel Communications: #18 STP Red with Black Stripe Fireman's Telephone: #18 STP Red with Yellow Stripe 6. Synchronized Clock Wiring: Line: Black Clock Correction: Red 7. Less Than 120 Volts: Use Industry Standard Methods Site lighting wire insulation shall be in solid colors to match the circuit voltage and phase color code. MARCH 2014 PAGE 4 OF 5

All UMHS owned facilities, unless noted otherwise, (University Hospital, THC, etc.) circuits shall be color coded as follows: 1. Three Phase Power Over 600 Volts: 2. Three Phase Power 480/277 Volts: Phase X(A): Red Phase Y(B): Blue Phase Z(C): Black Neutral: Gray 3. Three Phase Power 208/120 Volts: Phase X(A): Yellow Phase Y(B): Orange Phase Z(C): Brown 4. Less Than 120 Volts: Use Industry Standard Methods MARCH 2014 PAGE 5 OF 5