HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

Similar documents
Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

ENGINEERING. Edition No. 13 October 2002

Best Practices for Condensing Boilers

Dehumidifying with Dedicated Outdoor Air

Adding More Fan Power Can Be a Good Thing

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

A New Approach to Museum HVAC Design ASHRAE TECHNOLOGY AWARD CASE STUDIES

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Daikin Blueprint: Delivering Hot Water with a Chiller

The School District of Philadelphia Administration Headquarters

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

Temperature. In the HVAC area, we talk about two kinds of temperatures.

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

HVAC 101. H V A C S y s t e m s

Technical Criteria for District Energy Ready Buildings Master Requirement ENG 108 Building Department: ,

Feedback from potential users of UV in HVAC

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

Chilled Beams in Labs Eliminating Reheat & Saving Energy on a Budget

Technical Report Three

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Closing the Loop What s best for your system?

HVAC Mandatory Provisions Part II, Page 1

Achieving Dry Outside Air in an Energy-Efficient Manner

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Applying VRF? Don t Overlook Standard 15

GARCIA GALUSKA DESOUSA Consulting Engineers

C-Series. Unique Solutions for All-Indoor HVAC Projects

NOVEMBER 2012 THE EUROPEAN EXPERIENCE

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Description of All Alternatives Considered-

Appendix 13. Categories of Cooling and Heating systems

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Air Conditioning and process cooling Energy Components at a Glance

Applying VRF? Don t Overlook Standard 15

FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK

National Institutes of Health Building 37 Modernization Bethesda, Maryland MECHANICAL DEPTH EXISTING MECHANICAL SYSTEM

Computing Services Center

b.) Technical Information:

Continuous Commissioning: A Valuable Partner to Retrofit Projects

7. MECHANICAL SYSTEM DESIGN

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

CHAPTER 4. HVAC DELIVERY SYSTEMS

Cold Weather Operation Of Cooling Towers

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Benefits Offered by Passive Dehumidification Wheel Speed Control

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Architectural Engineering Senior Thesis Mechanical System Redesign

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

Shippensburg University

Madeira City Schools Madeira, Ohio. HVAC Assessment. December 2011 (Revised February 2012)

AHRI Certification Program Scopes - COOLING

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

Technical Assignment 3

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems

Evaluation. ems. Prepared By: Martha. a s Vineyard. Box P.O. Box June 2015

ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards

BUILDING DESIGN STANDARDS. AIR CONDITIONING DIVISION 23 Heating, Ventilation and Air Conditioning

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

Air Conditioning Clinic

TECHNICAL REPORT 3 Mechanical Systems and Existing Conditions Northfield Mental Healthcare Center Northfield, Ohio

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

August 15, 2013 Page 1 of 19

ASHRAE/IESNA Standard

COMcheck Software Version Review Mechanical Compliance Certificate

Challenges and Methods of Estimating a Conceptual HVAC Design

4-Pipe VAV vs. Active Chilled Beams for Labs

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

The Ed Roberts Campus Berkeley, CA

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

1 - This title will copy onto other forms Date

Mechanical Redesign, Proposal Elizabeth C. Krauss Mechanical Option September 18, 2013

APPLICATION GUIDE BEAMS

AHU Air Handling Unit Fundamentals. j.ilangumaran

Vapor-Compression Refrigeration

2014 ASHRAE TECHNOLOGY AWARD CASE STUDIES

DADANCO Technical Paper

Heat pump and energy recovery systems

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Energy-Efficiency Measures List

Improving Performance with a Building Tune-Up. Janice Peterson, P.E. LEED AP Market Manager, Building Operations BetterBricks

Energy Recovery Ventilation

Hello, my name is Sarah Hilden and I am a Marketing Engineer in the C.D.S. group at Trane.

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1

Do All DOAS Configurations Provide the Same Benefits?

Transcription:

ASHRAE s BEST This article was published in ASHRAE Journal, November 2010. Copyright 2010 American Society of Heating, Refrigerating and -Conditioning Engineers, Inc. Reprinted here by permission from ASHRAE at www.pageaumorel.com. This article may not be copied nor distributed in either paper or digital form by other parties without ASHRAE s permission. For more information about ASHRAE, visit www.ashrae.org. HONORABLE MENTION: COMMCIAL BUILDINGS, EXISTING HVAC modifications at the Complexe Desjardins in Montreal resulted in savings of 11.5 million kwh annually. Heat pumps and heat recovery systems were added to three of the four towers. office retrofit By Roland Charneux, P.E., Fellow ASHRAE The managers of Complexe Desjardins (Desjardins Gestion Immobilière) decided in 2004 to make major electromechanical upgrades to improve the overall energy efficiency of the 1970s-era office building complex in Montreal (Climate Zone 6A). The complex consists of three office towers sitting on a base structure that includes a central atrium, retail space and a food court. Below that are four levels of underground parking. In addition, a fourth tower is an independently owned hotel. Thorough study and analyses led to a solution that consisted of the installation of a 330 ton (1160 kw) heat pump and an innovative system to recover heat from computers, the lighting system and occupants, which would then be used to heat the envelope of the building and the outside air supply. This system also would humidify inexpensively. The design concept was successfully implemented on the North Tower and then applied to the other two office towers (East and South). The concept can be applied to other large existing buildings with little adaptation. Systems Before Renovation Before renovations, the HVAC systems in the 19-story North Tower (21,500 ft² [2000 m²]) had one 100% dedicated outdoor air system (DOAS) (54,000 cfm [25 500 L/s]), supplying air to perimeter About the Author Roland Charneux, P.E., is COO at Pageau Morel & Associes in Montreal. He is an ASHRAE-certified Healthcare Facility Design Professional (HFDP). 3 0 A S H R A E J o u r n a l a s h r a e. o r g N o v e m b e r 2 0 1 0

technology award case studies Outside Mixing Box in 100% Fresh During Day and 100% Return During the Night Exhaust Filters Preheating Pump Electric Heating Water Cooling Fans Return Fan Electric Heated Pan Toward Tower Perimeter Induction Units General Exhaust Figure 1: Original dedicated outdoor air system (DOAS) for the North Tower. The system had an electric coil, a chilled water coil, a runaround glycol loop for heat recovery on the exhaust air and an electrically heated hot water humidification pan. Heat Recovery induction units. This system was fitted with an electric coil, a chilled water coil, a runaround glycol loop for heat recovery on the exhaust air and an electrically heated hot water humidification pan (Figure 1). The induction terminal units have an electric coil and a chilled water coil to maintain adequate perimeter zone air temperature. On each floor, an air-conditioning unit draws its return air from close to the perimeter (obtaining its required outside air from there), supplying air conditioning to the floor s internal zones using chilled water coils. Complexe Desjardins is an all-electric building (Quebec s electricity is mostly renewable hydroelectricity) and, as such, the hot water used in the pan humidifiers was heated using an electric heater. Also, chilled water was produced centrally and distributed to the various HVAC rooms throughout the complex. At night, the dedicated outdoor air systems operate as a 100% recirculation system to provide perimeter heating. Also, another 100% DOAS supplies outside air Building at a Glance Name: Complexe Desjardins Location: Montreal Owner: Desjardins Gestion Immobilière Principal Use: Office Includes: Retail, Storage Employees/Occupants: 10,000 Substantial Completion: 2008 to the commercial retail spaces (23,000 cfm [10 850 L/s]). This system was identical to the previous system, though smaller in size. Finally, two recirculating, dual-duct systems (77,500 cfm and 58,000 cfm [36 600 L/s and 27 400 L/s]) supply conditioned air to spaces located within the lower levels of the tower (180,000 ft² [16 750 m²] of office spaces and storage areas). Those systems had a dual supply fan, an electric coil in the hot duct and a chilled water coil in the cold duct (Figure 2). Implemented Modifications Traditionally, in a northern climate such as Montreal, inexpensive air conditioning for internal spaces comes from airside economizer cycles. However, heating for the perimeter zones and heating and humidification of the outside air are still needed. Consequently, the airside economizer is basically wasting a lot of warm energy that could be reused if harnessed correctly. In this existing building retrofit, the cooling loads described in the previous section had to be harnessed to contribute to building heating and humidification loads using decentralized chillers acting as a heat pump and adiabatic humidifiers. In the North Tower, a 330 ton (1160 kw) heat recovery water source heat pump on the chilled water network was installed. It uses return chilled water to produce hot water used to heat and humidify outside air and to satisfy a part of the building envelope heating load. The hot water pan humidifiers were replaced with one-pass adiabatic humidifiers, using warm air to evaporate the water and producing humidification, while preconditioning the return air for sensible cooling purposes. The installation of a 330 ton (1160 kw) chiller (to act as a heat pump ) in the main ventilation mechanical room reduced required pipe lengths and installation costs (Figure 3). This chiller cools chilled water returning from the recirculation air-conditioning units located on each tower floor, using it as a heat source and precooling the chilled water returning to the chiller plant (reducing its load). Condenser N o v e m b e r 2 0 1 0 A S H R A E J o u r n a l 3 1

water (with glycol antifreeze) is supplied to the 100% dedicated outdoor air systems 4-01 and 2-31, as described later. Since the cooling load is present 24/7 in many parts of the complex, the heat recovery chiller is continuously providing heating capacity. The heat pump chiller load is controlled by the condenser heat needs. In the DOAS, a hot glycol coil had been installed before the electrical coil (which now serves as a second-stage heating), while adiabatic humidifiers replaced the hot water pan humidifiers (Figure 4). Similar modifications were made to the dual-duct systems serving the lower levels, except that the adiabatic humidifiers have been located before one of the return fans to reduce its size and costs (Figure 5). Also, during the humidification months, the exhaust air damper is completely closed, and air is exhausted from the spaces using other ducts, rebalancing the exhaust network. Also, a complete reconditioning of the affected HVAC systems was carried out. Combined together, those modifications allow heating and humidification of the towers using almost exclusively recovered energy from the indoor office spaces. Innovation Recovering the internal loads is not new. However, the originality of the solution lies in the innovative layout of the electromechanical equipment. First, decentralized heat recovery chillers were installed to minimize first costs and reduce the central plant chiller load. Consequently, there is no additional electrical energy demand on the building for the heat recovery systems. Second, installing the adiabatic humidifier in the return airstream of the dual-duct systems gives the hu- Outside Mixing Box in ±20% Outside During Day Exhaust Figure 2: Original dual-duct systems. Pump Chilled Water Pipework Serving Indoor AHUs Filters EGP EGP Fans Return Fans Electric Heated Pan Figure 3: Connections of the new heat recovering heat pump chillers (typical). Figure 4: Modified dedicated outdoor air systems. E C 330 Ton Heat Pump Chiller From Heat Pump Glycol Heating Adiabatic Electric Heating Water Cooling Condensate Condensate EFD Pump Hot Deck Cold Deck Return To DOAS Heating s 3 2 A S H R A E J o u r n a l a s h r a e. o r g N o v e m b e r 2 0 1 0

Advertisement formerly in this space.

midifier a higher air temperature to operate with, downsizing the equipment and further reducing first costs. Following the successful operation in the North Tower, the modifications were implemented in the East and South Towers. Annual energy savings have been calculated by measuring the chilled water flow rates and temperature differentials produced by the heat pump chillers (data logged every 15 minutes). This thermal energy directly equals energy saved from the use of the electrical coils and pan humidifiers. Energy consumed by the heat pump chillers has been considered to be equal to the energy saved by the central chiller plant, and is excluded from the calculations. Figures 6a and 6b illustrate some of those measurements. Table 1 gives the annual calculated totals. Improved Overall Efficiency Part of the project investment resulted in the major overhaul of the existing HVAC systems, replacing old equipment with modern motorized dampers, cooling and heating recovery coils or reconditioning the fan motors, fans and housing. The heated pan humidifiers required substantial maintenance each year with associated required downtime. The replacement of those humidifiers by adiabatic ones has helped reduce maintenance costs and downtime, ensuring better system operation. Furthermore, with many newer components added to the existing HVAC systems, the life expectancy of the equipment has been increased. Also, the newer equipment has been chosen for easier maintenance and longevity, which translates into productivity gains for the owner and operation personnel. For the three towers combined, the work performed required an Figure 5: Modified dual-duct single fan systems. Heating Power (kw) 2,250 2,000 1,750 1,500 1,250 1,000 750 5 0 5 10 15 20 25 30 35 40 45 Outside Temperature ( F) Figure 6a: Day measurements, South Tower heat pump chiller, December 2008. Heating Power (kw) Mixing Box in ±20% Outside During Day with No Exhaust 2,250 2,050 1,850 1,650 1,450 1,250 1,050 850 650 450 Filters Fans 250 5 0 5 10 15 20 25 30 35 40 45 Outside Temperature ( F) From Heat Pump Figure 6b: Night measurements, South Tower heat pump chiller, December 2008. EFD Adiabatic Glycol Heating 3 4 A S H R A E J o u r n a l a s h r a e. o r g N o v e m b e r 2 0 1 0

Towers Stories Day (kwh) Night (kwh) Total (kwh) Savings ($0.461/kWh) Demand Reduction (kw) North 19 1,146,200 952,000 2,098,200 CA$96,727 700 East 24 2,272,500 2,230,400 4,503,000 CA$207,588 1,700 South 32 2,332,500 2,576,000 4,908,500 CA$226,282 1,750 Total 5,751,200 5,749,400 11,509,700 CA$530,596 4,150 Table 1: Annual energy savings (calculated from chilled water measurements) are more than CA$500,000. investment of 3,390,000 Canadian dollars. This translates into a simple payback of 6.4 years (when excluding O&M benefits). Energy-efficiency grants amounted to CA$1,144,000, for a simple payback of 4.2 years. Additional energy-efficiency measures have been implemented such as new high-efficiency chillers, new direct digital controls and variable frequency drives on pumps. The total energy consumption of the site was reduced from 138,000 MWh in 2005 to 116,500 MWh in 2009, which is more than a 15% reduction. Environmental Impact Outside air supply meets or exceeds the minimum quantity requested by ASHRAE Standard 62.1. The modifications generate annual energy savings of more than 11,500,000 kwh. Since Quebec s electricity is mostly from hydro sources, the emission factor for the province is only 44 lb (20 kg) of CO 2 per MWh. As such, the avoided CO 2 emissions from the electric energy savings are 230 metric tons/year. However, when compared with an efficient combined-cycle gas-fired thermal plant with an emission factor of 992 lb (450 kg) of CO 2 per MWh, the avoided CO 2 emissions become 5,175 metric tons/year. Another comparison can be made assuming gas-fired boilers used for heating (emission factors of 118.9 lb per 1,000 ft³ [1.9 kg per m³]). The CO 2 emission savings would be 2,112 metric tons/year. This solution can contribute greatly to substantial reductions in CO 2 emissions in large existing buildings. Also, the installed heat pump uses R-134a, an HFC. Additionally, less water makeup and chemical treatment of the water is necessary. Advertisement formerly in this space. N o v e m b e r 2 0 1 0 A S H R A E J o u r n a l 3 5