NON-PROGRAMMABLE THERMOSTAT. The following Payne equipment is not compatible with the AC version (TSTATPPBAC01-B) of this

Similar documents
Standard Programmable Thermostat Homeowner s Guide / Installation, Start-Up, and Operating Instructions

Installation and Operating Instructions

Installation Instructions

Thermidistat Control Installation, Start-Up, and Operating Instructions

Installation Instructions

Installation Instructions

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03

INSTALLATION AND OPERATING INSTRUCTIONS

Installer s Guide ACONT200AN11AA 1 Heat (Gas, Oil* or Elec) / 1 Cool Electronic Non-Programmable, 4 Wire Hookup

ACCESSORY KIT INSTALLATION MANUAL

MAXIMUM UNIT AMPS MINIMUM WIRE SIZE

Installation, Start-Up, and Operating Instructions

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

Instruction Guide: Thermostat Operation

Installation, Start-Up, and Operating Instructions

Product Instructions. Viega Programmable Heat/Cool Thermostat. Technical data

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCNB001 TSTATBBNB001 P Digital Thermostat

Installation Instructions

Installation Instructions

User s Manual

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

installation and start-up instructions THERMIDISTAT CONTROL

Installation Instructions P/N

Installation Instructions

Installation Instructions

Installation, Start-Up, and Operating Instructions

Installation Instructions MODEL 8870

1F Non-Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

T8400C Universal Electronic Thermostats

TB-226 ZONE 3 MOTOR M6 M4 M2 M1 ZONE 2 MOTOR M6 M4 M2 M1 MOTOR M6 M4 M2 M1 24 VAC T'FORMER SYSTEM W2/E W1/B O RH RC RC/RH LINK.

Owner s Manual. Part Number 33CSCPACHP-01

T8000C Programmable Thermostat

ZONE 3 MOTOR M6 M4 M2 M1 ZONE 2 MOTOR M6 M4 M2 M1 MOTOR M6 M4 M2 M1 24 VAC T'FORMER SYSTEM W2/E W1/B O RH RC RC/RH LINK.

Comfort Zone (Rev 1.4) Installation and Start-Up Instructions

Installation and Start-Up Instructions

INSTALLATION MANUAL. Need Help? This manual covers the following models: T705. Power Type. Thermostat Applications Guide. Page.

CP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

INSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page.

Safety & Installation Instructions Model 8570

HEAT HEAT PUMP TOTALINE. Installation Instructions DIGITAL THERMOSTAT MODEL P FM. I2:00 Mo COOL

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL ELECTRO-MECHANICAL THERMOSTATS FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

Installation Instructions

Y8196A (T8196A Thermostat/ Q682A Subbase) Heating/Cooling New Construction Thermostat/Subbase Package Installation Instructions

INSTALLATION MANUAL. Need Help? This manual covers the following models: T805. Power Type. Thermostat Applications Guide. Page.

P/N TSTAT0709 DIGITAL THERMOSTAT. Installation Instructions HEAT COOL. Warmer HEAT PUMP. International Comfort Products 2003

Operator: Save these instructions for future use!

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS STANDARD PROGRAMMABLE THERMOSTAT

Product Data TSTAT. Thermostats Thermidistat TM Control BUILDER S THERMOSTAT NON-PROGRAMMABLE THERMOSTAT FEATURES/BENEFITS

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

Wiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel.

1 PREPARATIONS 2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT. 1E78 Non-Programmable Thermostat CONTENTS

Operator: Save these instructions for future use!

Installation Instructions

INSTALLATION AND MAINTENANCE INSTRUCTIONS. MHP4 Series. Self-Contained Heat Pump. Save these instructions for future reference

7-Day. Digital Thermostat. residential. & 2-cool

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

Installation, Start-Up, and Operating Instructions

asy Single Day up to 2-heat & 2-cool Stat

IF78 CAUTION CONTENTS YOUR THERMOSTAT REPLACES PREPARATIONS. Installation Instructions for. Heating & Air Conditioning. Non-Programmable Thermostat

FOSSILFUELKITAXWR02FFA1

Emerson Blue Easy Set 1H/1C

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

Installation Instructions Read and become familiar with these instructions before beginning installation.

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL DELUXE NON-PROGRAMMABLE THERMOSTATS THERMIDISTAT: INDUSTRY LEADING TEMPERATURE PLUS HUMIDITY CONTROL

T-32-TS Touchscreen Thermostat. Installation Manual

2 HEAT - 1 COOL Meets Residential California Title 24

Operator: Save these instructions for future use!

HydroZone Installation Manual

Installer : Save these instructions for future use!

Small Digital Thermostat Controller Temperature Control

Operator: Save these instructions for future use!

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

SC Installation, Operation & Application Guide

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Installer : Save these instructions for future use!

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Installer : Save these instructions for future use!

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Commercial Thermostat

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Install guide Customer Support: or Visit our website OFF FAN HEAT COOL AUTO ON

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

1F Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Smart Temp. Model

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

T8400C and T8401C Electronic Thermostats

Operator: Save these instructions for future use!

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

Safety & Installation Instructions

Operator: SaVe these instructions forfuture use

1F Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

installation and start-up instructions TWO-SPEED PURON PLUS HEAT PUMP

Operator: Save these instructions for future use!

TB-231 ZONE 3 DAMPER PC PO C ZONE 2 DAMPER PC PO C ZONE 1 DAMPER PC PO C 24VAC T FORMER R SYSTEM W2/E W1/B O Y G RH RC C RC/RH LINK.

1F98EZ-1421, Easy Install

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Transcription:

Installation Manual NN-PAMMABLE THEMSTAT TSTAT < < Fig. 1 Non-Programmable Thermostat NTE: ead the entire instruction manual before starting the installation. A98193 SAFET NSIDEATINS ead and follow manufacturer instructions carefully. Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installation may damage thermostat. ecognize safety information. This is the safety-alert symbol. hen you see this symbol on the equipment and in the instruction manual, be alert to the potential for personal injury. Understand the signal words DANE, ANIN, and AUTIN. These words are used with the safety-alert symbol. DANE identifies the most serious hazards which will result in severe personal injury or death. ANIN signifies a hazard which could result in personal injury or death. AUTIN is used to identify unsafe practices which would result in minor personal injury or product and property damage. INTDUTIN The Non-Programmable thermostat is an electronic 24-vac, non-programmable, manual changeover wall mount thermostat. This thermostat uses a single set point to maintain and control room temperature in both the heating and air conditioning modes. The thermostat is designed to maintain +/-2 F accuracy. No batteries are required; temperature, fan, mode, and installer configuration settings are preserved with power off. INSTALLATIN NSIDEATINS A. Air onditioner Model TSTATPPBA01-B, the Non-Programmable air conditioner thermostat may be wired with or without connecting a common wire between the indoor equipment and the thermostat. However, it is recommended to use a common wire whenever possible. ithout a common wire this thermostat becomes "power stealing." This means it will need to steal a small amount of power from the equipment to which it is connected. hen "power stealing" method is used, the supplied 270 ohm load resistor must be connected at the indoor unit. (See Fig. 2 and 3, and note.) NTE: Not all HVA equipment is compatible with power stealing type thermostats. For all non-payne equipment, consult the system equipment Installation Instructions before applying this thermostat in a power stealing manner. AUTIN: thermostat. The following Payne equipment is not compatible with the A version (TSTATPPBA01-B) of this A1AAD, A2AAD P8UA, P8LA P8HA TSTATXXNV10 Standing Pilot Furnaces il Furnaces as Furnace Thermostat onversion Kit Form: IM-TSTAT-05 ancels: IM-TSTAT-04 Printed in U.S.A. 8-99 atalog No. 53TS-TA6

B. Heat Pump Model TSTATPPBHP01-B, the Non-Programmable heat pump thermostat is compatible with all Payne heat pump systems. It is NT power stealing and MUST have both the and terminals connected to operate properly. This thermostat uses a green LED to indicate auxiliary heat and emergency heat operation. INSTALLATIN PEDUE 1 THEMSTAT LATIN Thermostat should be mounted: Approximately 5 ft (1.5m) from floor. lose to or in a frequently used room, preferably on an inside partitioning wall. n a section of wall without pipes or duct work. Thermostat should NT be mounted: lose to a window, on an outside wall, or next to a door leading to the outside. Exposed to direct light and heat from a lamp, sun, fireplace, or other heat-radiating object which may cause a false reading. lose to or in direct airflow from supply registers and return-air grilles. In areas with poor air circulation, such as behind a door or in an alcove. PEDUE 2 INSTALL THEMSTAT ANIN: Before installing thermostat, turn off all power to unit. There may be more than 1 disconnect. Electrical shock can cause personal injury or death. 1. Turn FF all power to unit. 2. If an existing thermostat is being replaced: a. emove existing thermostat from wall. b. Disconnect wires from existing thermostat, one at a time. Be careful not to allow wires to fall back into wall. c. As each wire is disconnected, record wire color and terminal marking. d. Discard or recycle old thermostat. NTE: Mercury is a hazardous waste and MUST be disposed of properly. 3. Separate front and back (mounting base) assembly of thermostat. 4. oute thermostat wires through hole in mounting base. Level mounting base against wall (for aesthetic value only, thermostat need not be leveled for proper operation) and mark wall through 2 mounting holes. 5. Drill two 3/16-in. mounting holes in wall where marked. 6. Secure mounting base to wall with 2 anchors and screws provided making sure all wires extend through hole in plastic. 7. Strip 1/4 in. insulation from thermostat wire and adjust length to reach terminal block connector on mounting base. Match and connect proper wiring in accordance with wiring diagrams. (See Fig. 2, 3, and 4.) 8. Push any excess wire back into wall. Seal hole in wall to prevent air leaks. Leaks can affect thermostat operation. Any excess wire left inside thermostat casing may also affect thermostat operation by interfering with airflow across the temperature sensor. 9. Snap thermostat together making sure terminal block connector aligns, and assembly is secure. 10. If "power stealing" method is used, be sure to attach 270 ohm load resistor at indoor unit. (See Fig. 2 and 3, and note.) 11. Turn on power to unit. n power up, depending on the thermostat model being used, the LD readout will display either, H for air conditioner model (1-stage heat/1-stage cool), or HP for heat pump model (2-stage heat/1-stage cool). PEDUE 3 SET THEMSTAT NFIUATIN onfiguration options allow the installer to configure the thermostat for a particular installation. These selections are intended to be made at installation and normally are not modified by the homeowner. Below is a list of available options followed by a description of each one. ption 01 -- Anticipator adjustment ption 03 -- Fahrenheit or elsius operation ption 04 -- Enable fan () N with heat () ption 10 -- (reversing valve) n with Heat or ool (present on Heat Pump model only) ption 13 -- oom temperature offset adjustment Note that not all configuration option numbers are used in this product. A. To Enter the onfiguration Mode: Press and hold FAN button for approximately 10 sec until room temperature disappears and the display reads "01". ou are now in configuration mode. NTE: If FAN button is pressed again, or if no button is pressed for 2 minutes, the thermostat will exit configuration mode and return to normal operation. To re-enter configuration mode, the FAN button must be pressed and held for 10 sec again. 2

hile in the configuration mode, the temperature display is used to show both the option number and the selected choice within each option. Each press of the MDE button alternates between the option number and the selection within that option. hen the configuration mode is first entered, option 01 is displayed. The up and down buttons now move between the available option numbers. nce an option number is selected, press the MDE button once to display the currently selected choice within that option. After the new choice is made, press the MDE button again to return to the option number display. hen finished with option selections, press the FAN button once to exit the configuration mode. PTIN 01 ANTIIPAT VALUE ADJUSTMENT This adjustment controls the sensitivity and cycle rate of the thermostat. Higher numbers increase the cycle rate in cooling. Lower numbers increase the cycle rate in heating. However, this feature will not allow more than 4 equipment cycles per hour (or 1 cycle every 15 minutes), regardless of setting. Values can range from 1 to 3. Factory default setting is 2. This default selection will provide optimum performance in nearly all installations. Try this setting first. Do not change setting unless there is evidence or need to do so. Unlike conventional anticipators, this setting is not to be determined by current draw. There is no need to measure, know, or compensate for current. AVAILABLE SELETIN: Use UP and DN buttons to move between values 01, 02, or 03. PTIN 03 FAHENHEIT/ELSIUS SELETIN This selection operates the thermostat in either Fahrenheit or elsius. Factory default is F. AVAILABLE SELETIN: Use UP and DN buttons to change between F and. PTIN 04 (FAN) N ITH (HEAT) SELETIN This selection determines whether (fan) output is to be N or FF when (furnace or strip heat) output is N. Most furnaces and fan coils manage their own blowers and do not require a separate signal. For these applications, select FF. Some auxiliary heaters require a separate signal from the thermostat to turn on the blower. In this case, select N. Factory default is F (off). AVAILABLE SELETIN: Use UP and DN buttons to change between N and FF. PTIN 10 (EVESIN VALUE) N ITH HEAT L SELETIN This selection is only available on heat pump model thermostats. This selection determines whether the reversing valve is energized in the heating or cooling mode. Factory default is. AVAILABLE SELETIN: Use UP and DN buttons to change between H and. PTIN 13 M TEMPEATUE FFSET ADJUSTMENT This option allows calibration (or deliberate miscalibration) of the room temperature sensor. There are various reasons why homeowners may want to have displayed temperature adjusted to a higher or lower value. The selected number is the number of degrees, plus or minus, which will be added to actual temperature. The numbers can range between -5 and +5. Factory default is 0. AVAILABLE SELETIN: Use UP and DN buttons to move between -5 and +5 in steps of 1. PEDUE 4 THEMSTAT PEATIN A. Temperature Display Thermostat will display room temperature until UP or DN button is pressed. The word SET appears when these buttons are pressed and the current set point is displayed. If no buttons are pressed for 5 sec, the display will change back to show room temperature. B. Timeguard Timer A 5-minute timeguard is built into the thermostat immediately upon power up, and any time the compressor turns off. The compressor will not turn on until the timeguard has expired. The timeguard affects only compressor operation. Pressing UP and FAN buttons simultaneously will override the timeguard for 1 cycle.. ycle Timer In normal heating and cooling operation the thermostat will not allow more than 4 equipment cycles per hour (or 1 cycle every 15 minutes). Both the and outputs have a 15-minute timer that starts counting down when the output is turned on, (e.g., if output is turned on for 9 minutes and then satisfies, it cannot turn back on for another 6 minutes regardless of demand). However, pressing UP and FAN buttons simultaneously or changing the set point will override the timer for 1 cycle. D. Minimum n Timer nce the equipment has turned on, it will remain on for a minimum of 3 minutes regardless of demand. However, the equipment can turn off in less than 3 minutes if a change in set point or a change in mode occurs. E. Staging Timer If the thermostat is a heat pump model, it has 2-stage heat capability. In normal operation there is a 15-minute delay between the first and second stages of heat. The output will energize first, then 15 minutes later, is allowed to come on if the thermostat determines it is not satisfying the demand. However, if the heating demand is greater than 5, there will be only a 3-minute delay before bringing on. F. Error Messages -- (two dashes) will be displayed if the thermostat cannot properly read room temperature. If -- appears, replace thermostat. E4 will be displayed if the thermostat has an internal memory failure. If E4 appears, replace thermostat. 3

PEDUE 5 HEK THEMSTAT PEATIN A. Fan peration 1. Press FAN button. This will start continuous fan operation. FAN annunciator will turn on. 2. Press FAN button again. This will stop continuous fan operation. FAN annunciator will turn off. B. Heating peration 1. Press MDE button until HEAT is displayed. 2. Press UP button until LD readout reads 30 above room temperature. Press UP and FAN buttons simultaneously to defeat timers. Heating system should begin to operate immediately. 3. For HP thermostats only, press MDE button until EMHT (emergency heat) appears. Press UP and FAN buttons simultaneously to defeat timers. Emergency heating ( is N, is FF) should begin immediately.. ooling peration 1. Press MDE button until L is displayed. 2. Press DN button until LD readout reads 30 below room temperature. Press UP and FAN buttons simultaneously to defeat timers. ooling system should begin to operate immediately. 4

A THEMSTAT TPIAL FAN IL/ FUNAE SINLE-SPEED AI NDITINE HEATIN FAN 24 VA HT 24 VA MM LIN N/A HEAT PUMP THEMSTAT Fig. 2 Typical Air onditioner * * See note 1 TPIAL FAN IL A99154 SINLE-SPEED HEAT PUMP 270 Ω, 10 * ESIST (SUPPLIED) HEATIN FAN 24 VA HT 24 VA MM LIN N/A A THEMSTAT * See note 1 * TPIAL FAN IL/ FUNAE 270 Ω, 10 * ESIST (SUPPLIED) HEAT STAE 2 EVESIN VALVE Fig. 3 Typical Heat nly A99115 FAN 24 VA HT 24 VA MM HEAT/L STAE 1 Fig. 4 Typical Heat Pump A98217 *IIN DIAAM NTE 1. If "power stealing" method is used, leave terminal disconnected connection between thermostat and equipment and add the supplied 270 ohm load resistor as shown. 5

NN-PAMMABLE THEMSTAT NFIUATIN ED wner/perator Date Indoor Unit Model No. utdoor Unit Model No. A) Mode Settings Mode (FF, HEAT, L, EMHT) Heat/ool Set Point Value Fan (AUT or N) B) onfiguration ptions 1 Anticipator (1-3: factory default = 2) 3 Fahrenheit or elsius (F or : factory default = F) 4 Fan n with (ff or n: factory default = ff) 10 (reversing valve) n with heat (H), or ool () (factory default = ) 13 oom Temperature ffset (-5 to +5: factory default = 0) (Note: onfiguration ptions 2, 5, 6, 7, 8, 9, 11, 12 are not applicable) A99292 6

7

1999 Payne Heating & ooling P.. Box 70, Indianapolis, IN 46206 8 imtstt05 atalog No. 53TS-TA6