SENTRA Series Water Unit

Similar documents
30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

RQE Series Temperature Controllers

OACS Outdoor Air-Cooled Central Chillers

Circulating Water Temperature Controller

SECTION STEAM CONDENSATE PUMPS

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

CVGF. Water Cooled Centrifugal Chillers

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS

Temptek Auxiliary Equipment

LXG-300 Series. Models with LXG-300 Series Instruments

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

Precise Temperature Control; Compact Footprint

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

DEAERATORS .005 ATMOSPHERIC DEAERATOR

FT900BD FLIGHT-TYPE DISHWASHER

GP SERIES Packaged Chillers

.005 ATMOSPHERIC DEAERATOR

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

TECHNICAL. Series 18. Pump Packages

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

.03 ATMOSPHERIC DEAERATOR

5. CONDENSATE PUMPS/UNITS

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

VENTLESS DOOR-TYPE DISHWASHER

470 Series Stamped Stainless Steel Pumps

Revitalize Building Mechanical Systems (4619)

FLANGE-MOUNT CENTRIFUGAL PUMPS

LQ AQ SQ. Air-cooled and water-cooled portable chillers

GIRTON CABINET WASHER MODEL 794A

Outstanding Performance; Application Flexibility

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

SECTION STEAM CONDENSATE PUMPS

Power Flame Incorporated

POULTRY MARKET CATALOG

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

Control and power circuit fusing to meet N.E.C.

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

Casey Craft

CL64T INDUSTRIAL TOTE WASHER

Circulating Oil Temperature Control System

SERIES CONVECTION OVENS

SECTION STEAM CONDENSATE PUMPS

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

Wilo IL Vertical Split-Coupled Inline Pumps

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

BuildingName The Description of the Project P DOCUMENTS

AccuBrine automated brine maker Technical Specifications

Screw Compressors HSD SERIES. Capacities from: 816 to 3002 cfm Pressures from: 80 to 217 psig

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

AIR HANDLER SPECIFICATION

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

DUPLEX CONDENSATE TANK SYSTEM

Landfill & Digester Gas Dryers. Features and Benefits

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

FT900 FLIGHT-TYPE DISHWASHER

Chemical Engineering and Applied Chemistry. Department: Phone number: (416)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

Gas and Electric Convection Ovens

1.1 This section applies to air handling units for HVAC Systems.

KEENER GRINDER PUMPS

Call us today! (800)

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Pumps SELECTION OF A PUMP

TM Series. Induced Draft, Counter Flow Optional Accessories

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Externally Heated Desiccant Air Dryer RP Series

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Superior Temperature Control. world of innovation

Modular Supply Make-Up Air Unit

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

SIOUX WATER HEATERS. Hot Water for Cold Weather Concrete Production. Better Concrete Higher Profits. Sioux Water Heaters and Steam Generators

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

CF-10A shown CF- 2A Shown

LARGE CAPACITY, REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING TM OPERATION AND REDUNDANT OPERATING SYSTEMS. MultiPlex.

Transcription:

SENTRA Series Water Unit Standard Unit: F to 0 F Process Fluid Temperatures* Optional High Temperature Configuration to 0 F Direct Injection Cooling 0 to kw Heaters to 7. HP Centrifugal Pumps (0-00 GPM) The Sentra water temperature control unit is used to preheat a process to the desired operating temperature by engaging the unit s electric immersion heater and recirculating the water in the system. Upon reaching the operating temperature, the Sentra water temperature control unit can continue to add heat or become a cooling device by exchanging a small amount of recirculated water with cooling water supplied from an external source. Tight temperature control is achieved by adding just the right amount of heat or by precisely metering cooling water into the system. * The Sentra relies on an external source of cooling water that must be colder than the desired set point Package for standard units having kw and smaller heaters and horsepower and smaller pumps. Approximate dimensions are: 9 x. x 9. (HxWxD). CONTROL INSTRUMENT... Choice of microprocessor instrument offers precise temperature control, machine status and diagnostic information presented in an easy-tounderstand interface (not visible from this angle). Package for standard units having & kw heaters and & 7. horsepower pumps. Approximate dimensions: x x (HxWxD). PRESSURE GAUGES... Indicates to process and from process pressure. The operator can determine P, pump direction and other operating characteristics from these gauges. SENSOR PROBE... Placed in the fluid steam for accurate temperature monitoring. The To Process sensor reads process temperature delivered to process. The High Temperature Limit protects against overheating. T Instruments include a From Process sensor probe. ELECTRICAL CABINET... Hinged door opens to allow full access to electrical components. Note: ka RMS SSCR COOLING CYLINDER FLOW METER... Included with T instruments up to 0 F to monitor process flow. Flow is displayed in GPM (gallons per minute) or LPM (liters per minute). Optional feature available with G instruments up to 0 F. Knowing the process flow is critical for fine tuning heat transfer efficiency. STAINLESS STEEL CABINET... Durable and sturdy construction, vented to dissipate excess process heat, and easy to clean. Rear cover panel is easy-to-remove for access to the mechanical components (panel removed in photo). MOTOR... Horizontal orientation extends pump seal service life and assures water and debris will not foul motor windings. HEATER... Flange mounted for easy service. TO PROCESS CONNECTION... All unit connection ports are machined into reinforced bosses to provide strong and rigid connections. COOLING WATER DRAIN CONNECTION COOLING VALVE... Provides precise control and easy maintenance. AVT TM modulating valve on G & T models. Solenoid valve on VE and 0 G & T units. FROM PROCESS CONNECTION HEATING CYLINDER... Cylinder castings are custom designed to eliminate leak-prone pipe fittings found on competitive models. The Heating and Cooling cylinders are flange mounted to the pump casing. PUMP CASING... With built-in seal flush for extended pump seal service life. COOLING WATER SUPPLY CONNECTION GALVANIZED STEEL BASE... Provides a rigid, strong, and long lasting support structure. POWER CORD... 0 factory installed 4 wire power cord ( power & ground). Ready for installation to customer supplied disconnect. Supplied on units up to hp and kw. (Not shown in picture). CASTERS... Swivel casters allow easy mobility. Made In The USA.

Centrifugal Pump The custom designed casing and impeller generates 0% more flow with the same horsepower as compared to many competitive machines. Standard hp pumps produce gpm at psi. Refer to the pump curves for more details. The pump casing has vertically facing machined ports that receive the heating and cooling cylinder assemblies. This eliminates dozens of flow restricting and leak prone pipe fittings found on some competitive machines. The motor is mounted horizontally to extend bearing and seal life. All Sentra temperature control units have an open drip proof motor with a stainless steel shaft. A pump seal flush line diverts a portion of the water flow over the pump seal to wash away solids and debris that may damage the seal. The standard shaft seal is covered by a lifetime warranty on most standard models. Cooling Valves A standard feature of all units with the T and G controllers up to 0 F is the AVT TM (Advanced Valve Technology), the industry s first and only modulating cooling valve designed for temperature control units. The AVT TM cooling valve offers straight line temperature control by opening or closing in 000 steps, from 0% to 00% to pass a precise flow to drain. This introduces cooling water from plant supplies with no water hammer pressure spikes or temperature swings. At start-up the AVT TM valve opens for about seconds so that trapped air can be purged from the process piping. A modulating cooling valve has the approximate cooling capacity of a solenoid valve. A standard feature of all units with the VE and 0 F G and T controllers is the solenoid controlled cooling valve. Pulsed by the microprocessor controller, the solenoid cooling valve provides good temperature control and is best applied on applications with small cooling loads and when a large temperature difference exists between the set point and cooling water temperatures. Straight line control is difficult to achieve with a solenoid valve because it is either fully open or closed. As it opens, it passes a slug of over-temperature water to drain and introduces an equal portion of cooling water. As it closes, it creates a pressure spike known as water hammer sending shock waves across the process and rapidly decreasing the useful life of pump seals, O-rings, and other system components. The over-cooling pulse creates wasteful heater operation and consumes electrical energy. The AVT TM modulating cooling valve eliminates this. The AVT TM valve provides precise cooling with no water hammer. The Sentra cannot achieve temperatures below the cooling water supply temperature and generally will provide slightly warmer water to process compared to the cooling water temperature even with the cooling valve fully open. Your Advantage sales representative can help you select the proper cooling valve for your application. Components Phone: 7-887-079 Web: www.advantageengineering.com HEATER... kw to kw are offered. The heater is made with a stainless steel sheath. The stainless steel sheath minimizes pitting damage from dissolved chemicals in the process water. The stainless steel sheath also performs well during high temperature duty when compared to copper heating elements. The heater has a flange for boltin mounting and an O ring seal to prevent leaking. The heater is easy to replace if needed. MECHANICAL CONTACTOR... Engages the heater to add heat to the process circulation. Solid state contactors are optional and recommended for applications where frequent heater cycling is anticipated. PROBES... Solid state temperature sensors are embedded in a threaded bulbwell (T, G & VE series units). J type thermocouple probes are used on 0 F G & T series units. All probes are terminated with quick-disconnect plugs to ease service and maintenance. WATER PRESSURE SWITCH... Monitors water supply pressure. Minimum supply pressure of 0 PSI is required to maintain process temperatures over 00 F. For process temperatures over 0 F minimum water supply pressure of PSI is critical. HEATING & COOLING CYLINDERS... Separate heating and cooling cylinders are required for precise blending of process and cooling water. Cylinders are cast iron from custom molds with reinforced bosses for process and ancillary connections. The tanks are flange mounted to the pump casing. PRESSURE GAUGES... To and From process pressure gauges are standard and are placed across the process to provide full process performance information. Pump generated pressure is determined by the difference between the two pressure readings. Plant water supply pressure is indicated when the unit is off and the plant s water supply pressure is on.

Control Instruments NEW NEW Temptender T Series Temptender T Series Controller Touch screen simplicity 4. full color touch screen interface More than screens with custom set-up, operation & system monitoring information. Home screen includes continuous setpoint and to process Digital flow rate display and from process temperature on informational screen. % Heating or Cooling indication on home screen. Standard shut down pump seal cooling feature. User configurable automatic start-up venting. Out-of-spec alarm including standard audible signal. Pump rotation monitor. Selectable English or Spanish language display. Selectable F or C temperature display. Selectable SPI or Modbus RTU communication. Optional Modbus TCP communication. Operates exclusive AVT modulating cooling valve. Drop in replacement for older Advantage HE series control instrument. For process fluid temperature up to 0 F Optional : High temperature fluid capability to 0 F Optional : nd setpoint cable 0ft length G Series G Series Controller Simple menu driven controller LCD display Home screen includes continuous setpoint and to process % Heating or Cooling indication on home screen. Operates exclusive AVT modulating cooling valve. Standard shut down pump seal cooling feature. User configurable automatic start-up venting. Out-of-spec alarm including standard audible signal. Selectable F or C temperature display. Selectable SPI or Modbus RTU communication. Optional Modbus TCP communication. Drop in replacement for older Advantage LE series control instrument. For process fluid temperature up to 0 F Optional : High temperature fluid capability to 0 F Optional : Flow meter with flow rate display KNOW YOUR FLOW... Digital flow display is a standard feature on the Temptender T Series control and an option available on the G Series Control for fluid up to 0 F. The high quality elastomer flow sensor rotates in the water stream to determine the flow rate which is displayed on the control instrument. A flow alarm can be configured to alert the user when flow falls out of range. Know your flow to optimize heat transfer and be alert to flow changes that can affect cycle time and part quality! VE Series Controller Single large display window with continuous display of To Process Status indicating lights for Power, Pump, Heat and Cool. On - Off rocker switch. Pulsed solenoid cooling valve is used with this instrument. For process fluid temperature up to 0 F. VE Series

Electrical Panel DIN rail mounted electrical components are selected for reliability and are UL approved. Color coded and numbered wires are easy to identify for service purposes. A 0 power cord is included on standard models up to HP and kw. The transformer supplies power to the control circuit. The pump motor starter is a high grade contactor type and includes over current, phase loss and short circuit protection. A long life mechanical contactor is standard for the heater. NEMA electrical construction is standard and suitable for the majority of applications. NEMA electrical construction is available. Optional Closed Circuit Systems The standard unit uses direct injection mixing of cooling water into the recirculated fluid for cooling. Optional closed circuit units use a heat exchanger to isolate the process recirculated fluid from the cooling fluid. This option can be supplied with or without an easy to fill expansion tank integral to the unit. Optional Mold or Process Purge The purge system removes the recirculating fluid from the process piping. Factory supplied using compressed air. The optional mold purge system is supplied as a factory installed option. Optional Dual Zone Dolly Processors often want to run different temperatures on each mold half to produce the best part quality. A dual zone dolly that holds two standard single zone units adds convenience by providing a common castered dolly with optional single cooling water supply and drain connection and optional electrical junction box where both units can be connected with a single power supply. Optional Beacon and/or High db Alarm In addition to the standard audible alarm supplied on the T and G series control instruments an optional high db audible alarm and/or alarm beacon can be supplied (T & G models only). Optional Stacking Stand A second options for processors to run different temperatures is a Stacking Stand. Holding two standard single zone units and providing a single cooling water supply and drain connection and optional electrical junction box where both units can be connected with a single power supply. Optional Non Ferrous Components Reduce ferrous metals in your system by selecting optional non-ferrous pump casing and suction and discharge tanks. Other Options ¾ AVT modulating cooling valve (T & G models) ½ - solenoid cooling valve (VE) Power disconnect switch Custom Unit Designs Advantage staffs an Engineering Department with experienced water system designers. Working from customer supplied facility and process information, our designers can customize a temperature control unit to your exact specifications, including higher flows and greater heater capacities.

Specifications 0 00 0 0 0 0 0 0 000 0 Heater kw 0 0 0 0 0 0 0 0 Process Pump HP 7 GPM 0 0 00 0 PSI Full Load Amperage volt 7.0 7.8 8. 0..8. 7.0 7.8 8...8. 40.. 4.0 4.8 4.. @ø/0hz 40 volt 8. 8.9 9. 0. 0.9...9 4...9 7. 0...0.4.8. Dimensions (inches) Height 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Width Depth 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Connections (inches) T/F S/D 4 Weight (pounds) Shipping 9 00 0 0 0 0 98 00 08 08 00 0 0 0 00 00 00 Heater kw Process Pump HP 7 7 7 GPM 00 00 00 PSI Full Load Amperage volt 4.8 49..4...9. 7. 9.9. 8. 88. 89.0. 9. 9.0 00. 07.4 @ø/0hz 40 volt.4.8 7.7...0.8..0 7.8 4.... 4.. 0..7 Dimensions (inches) Height 8 8 Width Depth 9 9 Connections (inches) T/F S/D 4 Weight (pounds) Shipping 0 8 0 70 8 9 8 9 0 0 Notes:. Derate heater output by % for 08//0 operation.. Consult factory for 0hz operations.. T - to process; F - from process. 4. S - water supply; D - drain.. Approximate unit shipping weight. Warranties* Standard Models with T & G Series Control Instruments: Years covering the entire machine. 4 Years covering the AVT TM valve, control instrument and heater. Lifetime covering the pump seal. Standard Models with VE Control Instrument: Years covering the entire machine. 4 Years covering the control instrument. Lifetime covering the pump seal. Instrument T : Temptender T Series G : G Series VE : VE Series Custom and Non Standard Models: Years covering the entire machine. *See Warranty Statement W-700 for full description of Limited Warranty. Phone: 7-887-079 Web: www.advantageengineering.com TEMPERATURE CONTROLLERS PORTABLE CHILLERS CENTRAL CHILLERS PUMP TANK STATIONS TOWER SYSTEMS FILTERS ADVANTAGE ENGINEERING, INC. East Stop 8 Road Greenwood, IN 44 phone: 7-887-079 fax: 7-88-77 Web site: www.advantageengineering.com Email: sales@advantageengineering.com 0 ADVANTAGE ENGINEERING, INC. Form #ADV-948 updated /0 SINCE PRODUCT INNOVATION AND IMPROVEMENT IS OUR CONSTANT GOAL, ALL FEATURES AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR LIABILITY.