EVALUATION SUBJECT: FIREPLACES DIVISION: SPECIALTIES SECTION: FIREPLACES AND STOVES. Report Holder:

Similar documents
EVALUATION SUBJECT: OUTDOOR DECORATIVE GAS FIRE PIT AND FIREPLACES DIVISION: SPECIALTIES SECTION: FIREPLACE SPECIALTIES

EVALUATION SUBJECT: OUTDOOR DECORATIVE GAS FIRE PIT AND FIREPLACES DIVISION: SPECIALTIES SECTION: FIREPLACE SPECIALTIES

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS EXTRA HEAVY OR SERVICE

EVALUATION SUBJECT: FIRE SUPPRESSION RANGE HOOD DIVISION: MECHANICAL SECTION: COMMERCIAL-KITCHEN HOODS.

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HYDRONIC PIPING.

GAS APPLIANCE LISTING PROGRAM

EVALUATION SUBJECT: DIVISION: PLUMBING SECTION: INSTRUMENTATION AND CONTROL FOR PLUMBING PLUMBING FIXTURES.

EVALUATION SUBJECT: DIVISION: PLUMBING SECTION: FACILITY WATER DISTRIBUTION INSTRUMENTATION AND CONTROL FOR PLUMBING

EVALUATION SUBJECT: PLUMBING SUPPLY FITTINGS DIVISION: PLUMBING SECTION: INSTRUMENTATION AND CONTROL FOR PLUMBING.

EVALUATION SUBJECT: DIVISION: PLUMBING SECTION: FACILITY WATER DISTRIBUTION INSTRUMENTATION AND CONTROL FOR PLUMBING

Effective Date: October 2016 Void After: October Product: Air Admittance Valves File No. C-3803

EVALUATION SUBJECT: DIVISION: PLUMBING SECTION: FACILITY WATER DISTRIBUTION INSTRUMENTATION AND CONTROL FOR PLUMBING

EVALUATION SUBJECT: LOW LEAD - PLUMBING SUPPLY FITTINGS, FLEXIBLE WATER CONNECTOR

EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS

Gas Equipment. Volume 4 June/July Issue date: June 25, 2008

EVALUATION SUBJECT: PLUMBING SUPPLY FITTINGS

EVALUATION SUBJECT: PLUMBING SUPPLY FITTING

EVALUATION SUBJECT: EPA WATERSENSE - PLUMBING SUPPLY FITTING DIVISION: PLUMBING SECTION: INSTRUMENTATION AND CONTROL FOR PLUMBING

LGB. Control Supplement. Gas fired boiler. Universal Control System. Series 2 Propane gas. Contents

Gas Equipment. Volume 3 April Issue date: April 29, 2009

Section 2, Reference publications: Updated the referenced publications to the current editions.

EVALUATION SUBJECT: EPA WATERSENSE PLUMBING SUPPLY FITTINGS DIVISION: PLUMBING SECTION: INSTRUMENTATION AND CONTROL FOR PLUMBING

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: FIRE RETARDANT WOOD TREATMENT REPORT HOLDER:

Completed Projects / Projets terminés

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

MOBILE FOOD SERVICE EQUIPMENT FIELD APPROVAL SUBMISSION INFORMATION

LGB Gas fired boiler

ENERVEX ADC100 DRAFT CONTROL

Installation Instructions

ASX7-4-IOM-6 J

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Stone Hearth Pizza Dome Oven

Gas Equipment. Volume 4 June/July Issue date: June 27, 2007

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

2015 IRC Significant Changes For Mechanical and Fuel Gas with LSUCCC Amendments

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

ASX7-5-IOM-3 J

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

DESIGN CLASS FUNCTION

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Owner s Guide Installation & Operation

Suggested Specifications Prestige Excellence 110

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

ELECTRONIC FIREPLACE DAMPER

Installation Instructions

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Installation Instructions

Installation Instructions

Gas Equipment. Volume 3 May Issue date: May 11, 2007

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

ELECTRONIC FIREPLACE DAMPER

Owner s Guide Installation & Operation

PCG305P 30-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

CONVERSION MANUAL CAUTION

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

Installation Instructions

INSTALLATION & OPERATION MANUAL FOR Achiever Charbroilers

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

TMB Baking TSV Gas Oven TAG Series. Contractor s Utility Requirements

MOBILE FOOD VENDING Food Trucks & Trailers

Chapter 3: General Regulations

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

Certificate of Compliance

2012 INTERNATIONAL FUEL GAS CODE VENTS

RG7D 1-Stage Heat Series

Owner s Guide Installation & Operation

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

G315/6 Cast Iron Boiler

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

Installation Instructions. Parts Included. Materials Needed. Tools You Will Need. 30 Sealed Gas Cooktop

Errata ANSI Z223.1 National Fuel Gas Code 2015 Edition

Installation Instructions

Installation Instructions

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

IPVB EC inline power venter

G315/5 Cast Iron Boiler

INSTALLATION AND SERVICE MANUAL

G515/7 Cast Iron Boiler

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Laser Safety Citations

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

INSTALLATION AND SERVICE MANUAL

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

TECHNICAL SPECIFICATIONS

Commercial Tankless Rack System

Home Stack Washer/Dryers

Transcription:

ICC-ES Report PMG-1290 Reissued 02/2017 This report is subject to renewal 02/2018 EVALUATION SUBJECT: FIREPLACES DIVISION: 10 00 00 SPECIALTIES SECTION: 10 30 13 FIREPLACES AND STOVES Report Holder: CF+D CUSTOM FIREPLACE DESIGN INC. 5490 HARVESTER ROAD, UNIT 1 BURLINGTON, ONTARIO, L7L 5V4 CANADA

ICC-ES PMG Product Certificate PMG-1290 Effective Date: February 2017 This listing is subject to re-examination in one year. www.icc-es-pmg.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council CSI: DIVISION: 10 00 00 SPECIALTIES Section: 10 30 13 Fireplaces and Stoves Product certification system: The ICC-ES product certification system includes testing samples taken from the market or supplier s stock, or a combination of both, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the supplier s quality system. Product: Listee: Fireplaces CF+D Custom Fireplace Design Inc. 5490 Harvester Rd. Unit #1 Burlington, Ontario, L7L 5V4 Canada www.cfd-na.com Compliance with the following codes: 2015, 2012 and 2009 International Fuel Gas Code (IFGC) 2015, 2012 and 2009 International Mechanical Code (IMC) 2015, 2012 and 2009 International Residential Code (IRC) Compliance with the following standards: Identification: ANSI Z21.50/CSA 2.22-2014, Vented Gas Fireplaces Marking material shall be identified by class number and shall meet the following specifications. All metal marking materials shall be rustproof. All marking shall be suitable for application to surfaces upon which applied and shall demonstrate suitable legibility. The designation of any class of marking shall not preclude the use of marking of a lower number class. Class I. Integral Marking Marking that is embossed, cast, stamped or otherwise formed in the part. This includes markings baked into an enameled surface. Class IIA-1. Permanent Plate Shall be made of metal having a minimum thickness of 0.012 in (0.30 mm) and shall be securely attached by mechanical means. Class IIA-2. Permanent Plate Shall be made of metal having a thickness of 0.006 to 0.012 in (0.15 to 0.30 mm) and shall have mechanical attachment means at all corners with a maximum spacing of 6 in (152 mm) between mechanical fasteners. Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this listing, or as to any product covered by the listing. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4

PMG-1290 Most Widely Accepted and Trusted Page 2 of 4 Class IIA-3. Permanent Plate Shall be made of metal having a thickness less than 0.006 in (0.15 mm) and shall be attached by means of non-water-soluble adhesive. These materials shall not be located on surfaces having temperatures exceeding 300 F. Class IIA-4. Permanent Plate Shall be made of pressure-sensitive metal foil requiring no solvent or activator and shall not be located on surfaces having temperatures exceeding 300 F (149 C). Class IIIA-1. Permanent Label Shall be made of material not adversely affected by water, shall be attached by means of non-watersoluble adhesive and shall not be located on surfaces having temperatures exceeding 300 F (149 C). Class IIIA-2. Permanent Label Shall be made of material not adversely affected by water, shall be attached by means of non-watersoluble adhesive and shall not be located on surfaces having temperatures exceeding 175 F (79.5 C). Class IIIB. Waterproof Marking Shall be printed directly on the part with waterproof marking not adversely affected by a temperature of 175 F (79.5 C) and shall not be used on surfaces having temperatures exceeding 175 F (79.5 C). Class IIIC. Waterproof Label Shall be made of material not soluble in water, and may use water-soluble adhesive for attachment means. Class IV. Semi-Permanent Plate or Label Shall be made of material which may be soluble in water and may use water-soluble adhesive for attachment means. Class V. Printed Marking Marking shall be clear and prominent and may be applied directly by any printing means. Class VI. Attached Tags Rating plate(s) Each appliance shall bear a plate or a combination of plates in proximity, of Class IIIA marking material located so as to be easily read when the appliance is in a normally installed position. A rating plate(s) applied to the inner surface of a control compartment door is considered acceptable. The following information shall appear on the plate(s): a) type of appliance. b) on an appliance suitable for use only with a vent damper device: For use only with automatic vent damper device Part No.. Follow installation c) an appliance suitable for use with or without a vent damper device: May be used with automatic vent damper device Part No.. Follow installation d) on an appliance where the trim panel assembly forms part of the draft hood relief mechanism: For use only with trim kit(s) Part No(s).. Follow installation e) the manufacturers or distributor's name and location. f) the manufacturer's or distributor's model designation of the appliance. g) a distinctive number that will identify an individual appliance. h) the manufacturer's normal hourly Btu input rating and manifold pressure in inches water column. i) type of gas for which equipped: Natural or Propane j) minimum permissible gas supply pressure for purpose of input adjustment. k) the statement: Vented Gas Fireplace Not for Use with Solid Fuel. The size of the lettering used for this marking shall be Vogue boldfaced upper case type, or equivalent, having a minimum letter height of 0.100 in (2.54 mm).* The minimum vertical spacing between lines of type shall be 0.066 in (1.67 mm). * This letter height measurement corresponds to 10-point type. This line spacing measurement corresponds to 2-point leading.

PMG-1290 Most Widely Accepted and Trusted Page 3 of 4 Installation: Model: l) identification of this Standard by indicating either the edition of the standard, or the most recent effective addenda thereto, with one of the following markings: ANS Z21.50-(year) CSA 2.22-(year) Vented Gas Fireplaces; ANS Z21.50a-(year) CSA 2.22a-(year) Vented Gas Fireplaces; or ANS Z21.50b-(year) CSA 2.22b-(year) Vented Gas Fireplaces. m) electrical rating-voltage, frequency (Hz), and total input in amperes. If the total input of all components is less than 12 amperes, the input marking may optionally be shown as less than amperes. * * This amperage rating shall be equal to or greater than the total input in amperes. n) ICC-ES PMG listing mark. o) where applicable, the statement: FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY or NOT FOR USE WITH GLASS DOORS. p) on direct vent gas appliances for manufactured home (USA only) or mobile home installation convertible for use with natural gas and liquefied petroleum (propane) gases, see Clause 1.1c), this marking shall be as follows: For natural gas when equipped with No. drill size orifice. For propane when equipped with No. drill size orifice. (Each orifice shall be clearly identified with regard to the gas for which it will be used and the orifice size shall be indicated on the spud or hood. Also see Clause 4.9.5). q) a direct vent gas appliance for manufactured home (USA only) or mobile home aftermarket installation for use with natural gas only or liquefied petroleum (propane) gases only, [see Clause1.1d)], shall be marked: This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home where not prohibited by local codes. See owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. r) a direct vent appliance for manufactured home (USA only) or mobile home aftermarket installation convertible for use with natural gas and liquefied petroleum (propane) gases [see Clause 1.1c)] shall be marked: This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. See owner's manual for details. This appliance is supplied with a conversion kit. s) the information on the instruction plate may be combined with the information on the rating plate. At least the following information shall appear on a single plate permanently affixed to the principle (main) assembly of the appliance: i) Manufacturer's or distributor's name; ii) Manufacturer's or distributor's model number of the appliance; iii) Manufacturer's normal input rating; iv) Type of gas for which equipped and manufacturer's recommended manifold pressure; and v) Symbol of the organization making the examination for compliance with this Standard. t) Where applicable, For use only with barrier(s) Part No(s). Follow installation CF+D Vented fireplaces shall be installed in accordance with the manufacturer's instructions and applicable codes. FOCUS and CFD LINEAR Fireplaces haves been tested and proved to comply with ANSI Z21.50/CSA 2.22. FOCUS and CFD LINEAR Fireplaces includes Enervex Intelli System (Power Vent Exhaust System with ADC100(150) Control Board, PDS-1 Pressure Sensor, ADF(MFD) Auto Damper & RS Exhaust Fan). Following FOCUS series of vented fireplaces are available with either Gas Burner system for logs (RHP - G46-18-01) or Gas burner System for glass media (RHP - G22-GL-18C-01). Name and Model Number Focus-Ergo Focus-Gyro Focus-Bathysca Description

PMG-1290 Most Widely Accepted and Trusted Page 4 of 4 Focus-Hetero 1400 Focus-Pax Focus-Emi FOCUS-NEO and CFD LINEAR fireplaces are available with Spark Ribbon Burner and Enervex Intelli System. Name and Model Number Focus-Neo 1500 Focus-Neo 1800 CFD-Linear 6018 CFD-Linear 12018 Description with Spark LBS48 Ribbon Burner with Spark LBS60 Ribbon Burner with Spark LBS48 Ribbon Burner with Spark LBS96 Ribbon Burner Conditions of Listing: 1. The CF+D vented fireplaces recognized in this listing must be installed in accordance with the manufacturer s published installation instructions and the applicable codes. 2. The CF+D vented fireplaces recognized in this listing are manufactured in Ontario, Canada under a quality control program with annual surveillance inspections by ICC-ES.