CPU HBX Control Systems Inc. Installation Manual Central Processing Unit 0550 Version 1.04

Similar documents
Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Installation Manual Central Processing Unit 0550 Version 2.00 ECO HBX Control Systems Inc.

Viessmann B1HA Boiler Series

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

Installation Manual ZON-0500 Version 2.30 ZON HBX Control Systems Inc.

Installation Manual. THM-0200 Programmable Thermostat Version 1.07 THM HBX Control Systems Inc.

B-40/B-41 Modulating Temperature Controller

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

P r o d u c t C a t a l o g u e

- Data Brochure Universal Reset Module 422

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

- Data Brochure Boiler Control 274

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

Dual Mixing Application

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

- Data Brochure Universal Reset Module 423

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

INSTRUCTION MANUAL P Heating and 1 Cooling

Installation and Operations Manual

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

Installation & Operation Manual

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

Geothermal Programming Guide. Central Processing Unit 1000 Version 1.33 ECO HBX Control Systems Inc. Page 1

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

SYSTEM CONTROL KIT Model: CK-41P

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

VX SERIES Wireless Thermostat with Occupancy Sensor

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

OPERATION & INSTALLATION MANUAL

- Data Brochure D 260. Boiler Control /09

Radiant Thermostat 519

Series: MBC1-TC Mini Benchtop Temperature Controller

prestige Control Application Supplement - TriMax

- Data Brochure Mixing Control 360

Programming Guide. Central Processing Unit 1000 Version 1.38 CPU HBX Control Systems Inc.

- Data Brochure Boiler Control 264e

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Operating Instructions. Temperature and Humidity EC Control. Model 35YV93

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

Installation & Operation Manual

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

- User Brochure tekmarnet 4 Setpoint Control 161

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

INSTALLATION INSTRUCTIONS

Installation Manual WAV-0110 WAV-0111 WAV Version WAV-0110 WAV-0111 WAV HBX Control Systems Inc. Page 1

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

- Data Brochure Universal Reset Control 364

120 VAC SYSTEM CONTROL KIT Model: CK-63

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Installation & Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Quest Power Electric Heat EHS 62 Pro

prestige Control Application Supplement - TriMax

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

SC Installation, Operation & Application Guide

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

Multiple Boilers Electro TS Series Application EB-C-STG5

Installation & Operation Manual

RC-2000 Thermostat Installation Instructions

Blade Series Heat Exchanger Operation and Installation

Digital Non-Programmable

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

120 VAC SYSTEM CONTROL KIT

7-Day. Digital Thermostat. residential. & 2-cool

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Climate Cŏntrol Multifunction Hydronic Control Installation and Operation Manual. Uponor Radiant Heating and Cooling Systems

SC Installation, Operation & Application Guide

1F90-60 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat (for Heat Only Systems)

Heatronic 4000 IO Heatronic /04 en-us. Features. 4 boiler control, DHW, BACnet and Modbus. Installation/Operating instructions (IO)

Control Application. Supplement - ACVMax

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

QTC15 Temperature Controller Operation Manual

Multi Boiler Guide. Kit #

Outdoor Reset IQ Option Card, p/n

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Transcription:

Installation Manual 0550 Version.04 Staging Mixing Differential Setpoint Pump Sequencer Dual Setpoint Control Systems Inc.

Control Systems Inc. Control Systems Inc. Hydronic Control Hydronic Version Control.04 Version.04 TABLE OF COTETS Introduction... - Safety Symbols & Warnings... Receipt & Inspection... Description... Technical Data and Dimensions... Wiring & Installation... 4 Wiring... 4 Installation... 4 Programming... 5- avigating the... 5 Control Mode... 5 Setup Menu... 6 Control Programming... 7- Mixing Control Programming... -9 Differential Setpoint Programming... 0- Pump Sequencer... - Dual Setpoint... 4-5 Table of of Contents Table of Contents Sample Wiring and Diagrams... 6-5 otes... 6 Warranty Information... 7 Comfort Comfort Control Control Innovation Innovation

H BX Hydronic Control Version.04 HYDROIC COTROLLER ITRODUCTIO This manual will help with the installation, parameter setting, troubleshooting and general maintenance requirements for the controller. To guarantee the safe and reliable operation of this control, you must first read this manual in detail and take particular note to any and all warnings or caution directives prior to connecting to AC power. Please consult and install the heating appliance in accordance with manufacture s recommendations. QR CODE Each ECO-0550 is labeled with a QR code, which when scanned will link to a digital version of this manual. If this manual is ever lost or damaged, simply scan this with a compatible device to download the latest manual version. SAFETY SYMBOLS & WARIGS Extreme Hazard This action poses a serious threat that could result in personal injury or death, as well as permanent damage to the equipment. Proceed with caution. Moderate Hazard This action may cause personal injury or have adverse effects on the installation process if handled incorrectly. Disconnect Power Source The presence of low voltage(4vac) or high voltage(0vac) could result in personal injury or permanent damage to components or equipment. Point of Interest This point clarifies pertinent information, or brings your attention to an action that may have adverse effects on the installation process. Drawing Reference Refer to the specified electrical or mechanical drawing at the back of the manual. Only suitably qualified individuals with formal training in electrical and Hydronic controls should attempt the installation of this equipment. Incorrect wiring and installation will affect the warranty provided with this unit. Wiring must be completed in accordance with the codes and practices applicable to the jurisdiction for the actual installation. Use only copper conductor supply wire suitable for at least 05 C The is a microprocessor based controller and as such is not to be regarded as a safety (limit) control. Please consult and install the heating or cooling appliance in accordance with the manufacturer s recommendations. RECEIPT & ISPECTIO After receiving, inspect the unit for any possible physical damage that may have occurred during transportation. After unpacking the unit make sure the box contains: x Remote Outdoor sensor x Universal sensors x Terminal Screwdriver (.5mm) x Cable ties x Manual Control Systems Inc. 05 Page

H BX Hydronic Control Version.04 HYDROIC COTROLLER DESCRIPTIO The is designed to be a stand-alone Outdoor Reset Control device. The purpose and function of the is to provide control for multiple applications. The applications are selectable through push button operation on the programming interface and consist of, Mixing, Differential Setpoint control or Pump Sequencer. Control The use of the as a Control allows the capability to run up to three On/Off boilers, or a single modulating boiler with DHW requirements. Mixing Control As a Mixing Control, the has the capability to run a single On/Off or modulating boiler. Mixing types include Modulating Mixing, Floating Action Valve or Injection Pump Differential Setpoint Control The, when selected as a Setpoint Control, will allow for Dual or Differential Setpoint requirements. Pump Sequencer This control allows the system to sequence and cycle pumps, override pumps and turn the pump off when the outdoor temperature goes above a certain value (WWSD). Dual Setpoint This control is for use when one or two independant setpoints are needed. Page

H BX Hydronic Control Version.04 TECHICAL DATA & DIMESIOS TECHICAL DATA Specifications: x Thermistor Input (0K Ohm) x Miscellaneous Input Signal x Relay Outputs (40VAC 0Amps) Dry Contacts x Modulating Output / Amp Dry Contact (0-0VDC) Input: 0VAC +/- 0% 60Hz 0A Max HD DHW WWSD BOILER SYSTEM OUTDOOR STG O STATUS 95 0 BOILER PROTECTIO DHW P ETER TARGET 0 80 0 SYS P O IJ P Relays: 40VAC 5A Max Input: 0VAC 5A Max Mod Output: -0V Weight: 0.408Kg Dimensions: 00mm W x 68mm H x 70mm ETL Listings: Meets CSA C. o. 4 Meets UL Standard 87 ETL Control o. 0684 Storage: 50 to 04 (0ºC to 40ºC) CPU DIMESIOS Input Signals (4) Side View Front View Rear View 66 mm 70.9 mm (.60 in) (.76 in) Mod or O/ () Outdoor 0 VAC Relay Outputs () Top View 88 mm 67 mm (7.40 in) (6.57 in) Bottom View mm 00 mm (4.76 in) (.94 in) Control Systems Inc. 05 Page

WIRIG AD ISTALLATIO H BX Hydronic Control Version.04 Wiring All signal wiring must be with a minimum of 8AWG wire at a maximum of 500ft., : Demand Signal Apply heat demand from a dry contact, or 4VAC, 4: Demand Signal Used for DHW or Setpoint demand. 5, 6: Modulating / Contacts Modulating or output. Also used in differential setpoint output for modulating devices. Inputs 7, 0: Primarily used for boiler temperature but also used for setpoint temperature in Setpoint controls. 8, 0: Used for DHW or setpoint on controls and low temperature system temperature on Mixing control. Also used for setpoint temperature. 9, 0: Outdoor temperature. Only on and Mixing controls. 8, 9: Relay Generally used as a system pump in boiler mode, injection or system pump in mixing mode or as an alarm in pump sequencer mode. 6, 7: Relay Generally used as a pump contact valve or as a third stage boiler. 4, 5: Relay This relay is generally a pump contact or can be used as a second stage boiler or as a third stage boiler. (Relays, and are dry contacts and rated for a maximum of mps.) Please ensure no power is applied to pin 5, 6 when in any modulating mode. 4VAC MAX 4-0v + A - DO OT COECT POWER HERE 5 BL 6 BL 7 8 9 0 0 L 4 5 6 7 8 9 Demand Input Demand Input Contacts Inputs Installation The is designed to be wall mounted or installed in a separate electrical enclosure. The unit should be mounted inside and protected from falling water and high humidity conditions. With all the covers in place it is designed to protect any individual from accidental electrical shock. It is not suitable for installation in hazardous locations and should not be placed close to any electromagnetic fields. Identify the four mounting holes on the, mark on the wall the desired location of mounting. Predrill, anchor and fasten four screws for mounting. Hang and fasten tight to desired locations Complete wiring connections in accordance with terminal locations. Relay Relay Relay Supply Power 0 VAC Mounting Holes Page 4

AVIGATIG E All programming steps within the are achieved by using the three buttons (and combination thereof) located below the screen. The button is used to scroll down in menu screens and decrease a value within specific options. The button is used to scroll up in menu screens and increase a value in specific options. The ETER button is used to access the setpoint menu and select a setting. H BX Hydronic Control Version.04 HD DHW WWSD BOILER SYSTEM OUTDOOR STG O STATUS 95 0 BOILER PROTECTIO DHW P TARGET 0 80 0 SYS P O IJ P Relays: 40VAC 5A Max Input: 0VAC 5A Max Mod Output: -0V COTROL MODE The programming instructions for the are broken down into the four control modes listed below. When the control is first plugged in you are asked to select which control mode you would like your to operate in. To select your control mode simply use the or buttons to select the correct mode then wait five seconds to accept your selection. CHOOSE COTROL TYPE.04 ) STAGIG ) MIXIG ) DIFFERETIAL 4) PUMP SEQ 5) DUAL SETPOIT Mode (Default = Mode) Programming for this mode can be found on pages 8 through. This mode is used when running boilers only. The boiler configurations available in this mode are single modulating, On/Off boiler, two stage On/Off boiler and three stage On/Off boiler. With single and stage boiler operation the control will run the boiler pump and DHW pump. ETER CHOOSE COTROL TYPE.04 ) STAGIG ) MIXIG ) DIFFERETIAL 4) PUMP SEQ 5) DUAL SETPOIT CHOOSE COTROL TYPE.04 ) STAGIG ) MIXIG ) DIFFERETIAL 4) PUMP SEQ 5) DUAL SETPOIT Mixing Mode Programming for this mode can be found on pages 4 through. This mode is used when running mixing pumps or valves. Mixing configurations include PMIp, Modulating, and Floating Action Valve. In this mode the control can run up to on/ off boilers or a single mod boiler, depending on other options selected in the control. In modes other than Floating Valve the control Signals (4) will run O/ the injection and system pump. Differential Setpoint Mode Programming for this mode can be found on page. This mode is used when running a differential setpoint. In differential mode, the control will also send a modulating signal output based on how far the control is from the differential. This can be used to run a pump in modulating applications for constant flow. Input Mod or () Outdoor 0 VAC Relay Outputs () CHOOSE COTROL TYPE.04 ) STAGIG ) MIXIG ) DIFFERETIAL 4) PUMP SEQ 5) DUAL SETPOIT Pump Sequencer Programming for this mode can be found on page. This mode is used to provide pump control for two pumps in a duty, standby situation. This control allows the system to sequence and cycle pumps, override pumps and turn the pumps off when the outdoor temperature goes above a certain value (WWSD) CHOOSE COTROL TYPE.04 ) STAGIG ) MIXIG ) DIFFERETIAL 4) PUMP SEQ 5) DUAL SETPOIT Dual Setpoint Programming for this mode can be found on page 5. This mode is used when one or two independant setpoints are needed. Each setpoint is set up individually and each has its own thermistor input and relay outputs: Each setpoint has its own normally open and normally closed contacts (which can be used for heating and/or cooling). Control Systems Inc. 05 Page 5

H BX Hydronic Control Version.04 SETUP MEU the SETUP menu is used for entering the design values, as well as assign different control options. to access the setup menu, push the ETER button on the STATUS screen. Use the or buttons to scroll through the various settings. To select a parameter, align the cursor arrow with the desired parameter and press the ETER button. the arrow will become solid, which indicates that a parameter has been selected. Adjust the setting to the desired value with the or buttons. Once the correct value is set, push the ETER button. This will deselect the parameter. To go to the previous screen, push and hold the ETER button. If the SETUP menu is left for more than 90 seconds, the display will change to the STATUS screen and the control will resume operation. HD DHW WWSD BOILER DHW OUTDOOR STG O STATUS BLR P O TARGET 0 95 50 0 DHW P SYS P O SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) MIXIG SETUP 5) HEAT DEMAD 6) C OR BOILER SETUP.00 ) STAGES MOD ) MOD TIME S ) MI MOD % 0% 4) MOD SETPT Page 6

BOILER MODE H BX Hydronic Control Version.04 Multicolour backlit Display The Multicolour Backlit Display is one of the key features of the Controls stand-alone Control. Depending on which mode of operation is selected the screen colour will change to indicate information about the status of the system. Screen Colors Light Blue - o Heat Demand Red - Demand (DHW or Heat Demand) and running Yellow - Heat Demand O, boiler running but in boiler protection Dark Blue - Heat Demand O and boiler satisfied Status Screen Warm Weather Shut Down Domestic Hot Water Demand Heat Demand HD DHW WWSD BOILER DHW OUTDOOR STATUS 05 95 0 Current Temperatures TARGET 6 0 Target DHW Tank Target STG O BLR P O DHW P SYS P O DO OT 4VAC COECT POWER MAX HERE 4-0v + A - DO OT COECT POWER HERE 5 BL 6 BL 7 8 9 0 0 L 4 5 6 7 8 9 Heat Demand Input Aquastat Mod O/ DHW Outdoor System Pump DHW Pump Pump Supply Power 0 VAC Control Systems Inc. 05 Page 7

BOILER MODE PROAMMIG GUIDE H BX Hydronic Control Version.04 ) BOILER SETUP SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) HEAT DEMAD 5) C OR Setup This setting is used to configure the boiler staging component in your system. STAGE SETUP ) STAGES ) DIFF BOILER SETUP.00 0 Stages This setting will allow you to select the boiler stage. ( to, MOD) Default: ) STAGES ) DIFF BOILER SETUP.00 0 Differential Adjust this setting to the desired differential for the boiler. This will center the differential around the setpoint. (eg. 0 below/above) ( to 60) Default: 0 BOILER SETUP.00 ) STAGES ) DIFF ) ROTATE 4) LAG TIME 0 M / STAGE SETUP Stages This setting will allow you to select the boiler stage. ( to, MOD) Default: BOILER SETUP.00 ) STAGES ) DIFF ) ROTATE 4) LAG TIME 0 M Differential Adjust this setting to the desired differential for the boiler. This will center the differential around the setpoint. (eg. 0 below/above) ( to 60) Default: 0 BOILER SETUP.00 ) STAGES ) DIFF ) ROTATE 4) LAG TIME 0 M BOILER SETUP.00 ) STAGES ) DIFF ) ROTATE 4) LAG TIME 0 M Rotate The time of rotation between boilers is 48 hours of run time. It means that the boilers are going to rotate when the first boiler exceeds the second by 48 hours and vice versa. (Y/) Default: Lag Time When the the boiler is set for two or more stages, this setting will be set for the minimum lag time between boiler stages. This is a time delay between stages. Even if th differential has been exceeded this time must elapse before that stage can come on. (M to 40M) Default: M Page 8

H BX Hydronic Control Version.04 BOILER SETUP.00 ) STAGES ) MOD TIME ) MI MOD % 4) MOD SETPT MOD S 5% MOD BOILER SETUP Stages This setting will allow you to select the boiler stage. ( to, MOD) Default: BOILER SETUP.00 ) STAGES ) MOD TIME ) MI MOD % 4) MOD SETPT MOD S 5% Mod Time This setting sets the time between the steps when the boiler needs to increase or decrease the firing rate. Each step is % for all situations. (S to 40S) Default: S BOILER SETUP.00 ) STAGES ) MOD TIME ) MI MOD % 4) MOD SETPT MOD S 5% Minimum Mod % This setting is used to set the lowest modulating level the boiler can go down to. This will also be the starting point whenever there is a new demand. (0% to 95%) Default: 5% BOILER SETUP.00 ) STAGES ) MOD TIME ) MI MOD % 4) MOD SETPT MOD S 5% Mod Setpoint In this mode the 0-0VDC signal does not directly run the burner. The 0-0VDC signal is interpreted by the boiler as a setpoint. The boiler in this mode will modulate the burner to achieve that setpoint. (Y/) Default: Control Systems Inc. 05 Page 9

) DESIG TEMPERATURE H BX Hydronic Control Version.04 SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) HEAT DEMAD 5) C OR Design Temperatures Design Temperature allows you to customize each design temperature for your system DESIG TEMPERATURES SETUP DESIG TEMPERATURES.00 ) OUTDOOR 0 ) MAX BOILER 80 ) MI BOILER 40 4) WWSD 70 Outdoor Temperature This is used in the outdoor reset design calculation. This option should be set to reflect your specific city or region. (-50 to 0) Default: 0 DESIG TEMPERATURES.00 ) OUTDOOR 0 ) MAX BOILER 80 ) MI BOILER 40 4) WWSD 70 Maximum Temperature This is used in the outdoor reset design calculation, and also serves as the maximum setting for the boiler. This is the maximum boiler temperature for the coldest day. (40 to 00) Default: 80 DESIG TEMPERATURES.00 ) OUTDOOR 0 ) MAX BOILER 80 ) MI BOILER 40 4) WWSD 70 Minimum Temperature This is the minimum boiler temperature. Set this to the temperature you would like the boiler to be when the outdoor temperature approaches WWSD. (/5 to 00) Default: 40 This is the supply Temperature. Keep this in mind when selecting this feature. DESIG TEMPERATURES.00 ) OUTDOOR 0 ) MAX BOILER 80 ) MI BOILER 40 4) WWSD 70 Warm Weather Shut Down This setting is used to set the temperature in which the will go into WWSD. If the system rises above this temperature, the system will be shut off. In WWSD the boilers and all pumps will shut off. (5 to 0) Default: 70 Page 0

) DHW SETUP SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) HEAT DEMAD 5) C OR H BX Hydronic Control Version.04 Domestic Hot Water (DHW) Setup DHW setup allows you to program domestic hot water options in your system. DHW SETUP.00 ) USE DHW ) PRIORITY ) FAST DHW 4) BOIL SETPT 80 5) SETPOIT 0 6) DIFF 8 DHW SETUP.00 ) USE DHW ) PRIORITY ) FAST DHW 4) BOIL SETPT 80 5) SETPOIT 0 6) DIFF 8 DOMESTIC HOT WATER SETUP Use DHW Once this option is enabled you will be able to program the remaining options for your DHW setup. (Y/) Default: DHW Priority This selection will allow the DHW demand to ovverride the heating system for a max of 60 minutes in order to satisfy the DHW demand. Once 60 minutes have passed and there is still unsatisfied heat demand, the control will automatically switch back to accomodate the demand for heat. (Y/) Default: DHW SETUP.00 ) USE DHW ) PRIORITY ) FAST DHW 4) BOIL SETPT 80 5) SETPOIT 0 6) DIFF 8 DHW SETUP.00 ) USE DHW ) PRIORITY ) FAST DHW 4) BOIL SETPT 80 5) SETPOIT 0 6) DIFF 8 DHW SETUP.00 ) USE DHW ) PRIORITY ) FAST DHW 4) BOIL SETPT 80 5) SETPOIT 0 6) DIFF 8 DHW SETUP.00 ) USE DHW ) PRIORITY ) FAST DHW 4) BOIL SETPT 80 5) SETPOIT 0 6) DIFF 8 Fast DHW (Only Applies to Multiple Operation) This option will allow all the boilers to come on immediately when there is a call for DHW. The boilers will still stage off at the normal differential. This option allows for faster DHW heating. (Y/) Default: Setpoint This option allows you to set the maximum boiler temperature when the DHW demand is on. This will override the calculated boiler target from the designs. (50 to 00) Default: 80 Setpoint This option allows you to select your DHW target temperature in the tank. (50 to 00) Default: 0 Differential This is the differential for the DHW tank. Set this parameter to the desired differential for the DHW tank. ( to 60) Default: 8 Control Systems Inc. 05 Page

4) HEAT DEMAD H BX Hydronic Control Version.04 SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) HEAT DEMAD 5) C OR Heat Demand This setting indicates that the is in a permanent heat demand. This can be used instead of attaching a thermostat. (Y/) Default: 5) CELSIUS OR FAHREHEIT SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) HEAT DEMAD 5) C OR Celsius or Fahrenheit Use this setting to change the display format from Celsius ( C) to Fahrenheit (). (/ C) Default: Page

MIXIG MODE Multicolour backlit Display H BX Hydronic Control Version.04 The Multicolour Backlit Display is one of the key features of the Controls stand-alone Control. Depending on which mode of operation is selected the screen colour will change to indicate information about the status of the system. Screen Colors Light Blue - o Heat Demand Red - Demand (DHW or Heat Demand) and running Yellow - Heat Demand O, boiler running but in boiler protection Dark Blue - Heat Demand O and boiler satisfied Status Screen Warm Weather Shut Down Domestic Hot Water Demand Heat Demand Current Temperatures HD DHW WWSD BOILER SYSTEM OUTDOOR STG O STATUS BOILER PROTECTIO DHW P TARGET 0 80 95 0 0 SYS P O IJ P Target Low Temp System Target Protection Enabled DO OT 4VAC COECT POWER MAX HERE 4-0v + A - DO OT COECT POWER HERE 5 BL 6 BL 7 8 9 0 0 L 4 5 6 7 8 9 Heat Demand Input Aquastat Mod O/ Mod Valve System Outdoor System Pump Injection Pump System Pump Valve Down Pump DHW Pump Valve Up Pump DHW Pump Supply Power 0 VAC Control Systems Inc. 05 Page

H BX Hydronic Control Version.04 MIXIG MODE PROAMMIG GUIDE ) BOILER SETUP SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) MIXIG SETUP 5) HEAT DEMAD 6) C OR Setup This setting is used to configure the boiler staging component in your system. STAGE SETUP ) STAGES ) DIFF BOILER SETUP.00 0 Stages This setting will allow you to select the boiler stage. ( to, MOD) Default: ) STAGES ) DIFF BOILER SETUP.00 0 Differential Adjust this setting to the desired differential for the boiler. ( to 60) Default: 0 BOILER SETUP.00 ) STAGES ) DIFF ) ROTATE 4) LAG TIME 0 M / STAGE SETUP Stages This setting will allow you to select the boiler stage. ( to, MOD) Default: BOILER SETUP.00 ) STAGES ) DIFF ) ROTATE 4) LAG TIME 0 M Differential Adjust this setting to the desired differential for the boiler. This will center the differential around the setpoint. (eg. 0 below/above) ( to 60) Default: 0 BOILER SETUP.00 ) STAGES ) DIFF ) ROTATE 4) LAG TIME 0 M BOILER SETUP.00 ) STAGES ) DIFF ) ROTATE 4) LAG TIME 0 M Rotate The time of rotation between boilers is 48 hours of run time. It means that the boilers are going to rotate when the first boiler exceeds the second by 48 hours and vice versa. (Y/) Default: Lag Time When the the boiler is set for two or more stages, this setting will be set for the minimum lag time between boiler stages. This is a time delay between stages. Even if th differential has been exceeded this time must elapse before that stage can come on. (M to 40M) Default: M Page 4

H BX Hydronic Control Version.04 BOILER SETUP.00 ) STAGES ) MOD TIME ) MI MOD % 4) MOD SETPT MOD S 5% MOD BOILER SETUP Stages This setting will allow you to select the boiler stage. ( to, MOD) Default: BOILER SETUP.00 ) STAGES ) MOD TIME ) MI MOD % 4) MOD SETPT MOD S 5% Mod Time This setting sets the time between the steps when the boiler needs to increase or decrease the firing rate. each step is % for all situations. (S to 40S) Default: S BOILER SETUP.00 ) STAGES ) MOD TIME ) MI MOD % 4) MOD SETPT MOD S 5% Minimum Mod % This setting is used to set the lowest modulating level the boiler can go down to. This will also be the starting point whenever there is a new demand. (0% to 95%) Default: 5% BOILER SETUP.00 ) STAGES ) MOD TIME ) MI MOD % 4) MOD SETPT MOD S 5% Mod Setpoint In this mode the 0-0VDC signal does not directly run the boiler. the 0-0VDC signal is interpreted by the boiler as a setpoint. The boiler in this mode will modulate the burner to achieve that setpoint. (Y/) Default: Control Systems Inc. 05 Page 5

H BX Hydronic Control Version.04 ) DESIG TEMPERATURE SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) MIXIG SETUP 5) HEAT DEMAD 6) C OR Design Temperatures Design Temperature allows you to customize each design temperature for your system. DESIG TEMPERATURES.00 ) OUTDOOR 0 ) MAX BOILER 80 ) MI BOILER 40 4) SYSTEM 0 5) MI SYSTEM 70 6) WWSD 70 DESIG TEMPERATURES.00 ) OUTDOOR 0 ) MAX BOILER 80 ) MI BOILER 40 4) SYSTEM 0 5) MI SYSTEM 70 6) WWSD 70 DESIG TEMPERATURES.00 ) OUTDOOR 0 ) MAX BOILER 80 ) MI BOILER 40 4) SYSTEM 0 5) MI SYSTEM 70 6) WWSD 70 DESIG TEMPERATURES.00 ) OUTDOOR 0 ) MAX BOILER 80 ) MI BOILER 40 4) SYSTEM 0 5) MI SYSTEM 70 6) WWSD 70 DESIG TEMPERATURES.00 ) OUTDOOR 0 ) MAX BOILER 80 ) MI BOILER 40 4) SYSTEM 0 5) MI SYSTEM 70 6) WWSD 70 DESIG TEMPERATURES.00 ) OUTDOOR 0 ) MAX BOILER 80 ) MI BOILER 40 4) SYSTEM 0 5) MI SYSTEM 70 6) WWSD 70 DESIG TEMPERATURES SETUP Outdoor Temperature This is used in the outdoor reset design calculation. This option should be set to reflect your specific city or region. (-50 to 0) Default: 0 Maximum Temperature This is used in the outdoor reset design calculation, and also serves as the maximum setting for the boiler. This is the maximum boiler temperature for the coldest day. (40 to 00) Default: 80 Minimum Temperature This is the minimum boiler temperature. Set this to the temperature you would like the boiler to be when the outdoor temperature approaches WWSD. If the actual boiler temperature falls below this setting, the control will enter boiler protection mode and shut off mixing. (Off/5 to 00) Default: 40 This is the supply Temperature. Keep this in mind when selecting this feature. System Temperature This is used to setup the maximum temperature for your low temperature system on the coldest day. (0 to 80) Default: 0 Minimum System Temperature This is used to setup the lowest temperature you would like in the low temperature system. The setpoint will hit this when the outdoor temperature approaches WWSD. (0 to 80) Default: 0 Warm Weather Shut Down This setting is used to set the temperature in which the will go into WWSD. If the system rises above this temperature, the system will be shut off. In WWSD the boilers and all pumps will shut off. (5 to 0) Default: 70 Page 6

H BX Hydronic Control Version.04 ) DHW SETUP SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) MIXIG SETUP 5) HEAT DEMAD 6) C OR Domestic Hot Water (DHW) Setup DHW setup allows you to program domestic hot water options in your system. DOMESTIC HOT WATER SETUP DHW SETUP.00 ) USE DHW ) PRIORITY ) FAST DHW 4) BOIL SETPT 80 Use DHW Once this option is enabled you will be able to program the remaining options for your DHW setup. (Y/) Default: AQUASTAT OLY I MIXIG MODE DHW SETUP.00 ) USE DHW ) PRIORITY ) FAST DHW 4) BOIL SETPT 80 AQUASTAT OLY I MIXIG MODE Priority This selection will allow the DHW demand to ovverride the heating system for a max of 60 minutes in order to satisfy the DHW demand. Once 60 minutes have passed and there is still unsatisfied heat demand, the control will automatically switch back to accomodate the demand for heat. (Y/) Default: DHW SETUP.00 ) USE DHW ) PRIORITY ) FAST DHW 4) BOIL SETPT 80 AQUASTAT OLY I MIXIG MODE DHW SETUP.00 ) USE DHW ) PRIORITY ) FAST DHW 4) BOIL SETPT 80 Fast DHW (Only Applies to Multiple Operation) This option will allow all the boilers to come on immediately when there is a call for DHW. The boilers will still stage off at the normal differential. This option allows for faster DHW heating. (Y/) Default: Setpoint This option allows you to set the maximum boiler temperature when the DHW demand is on. This will override the calculated boiler target from the designs. (50 to 00) Default: 80 AQUASTAT OLY I MIXIG MODE Control Systems Inc. 05 Page 7

H BX Hydronic Control Version.04 4) MIXIG SETUP SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) MIXIG SETUP 5) HEAT DEMAD 6) C OR Mixing Setup Mixing Setup is used to select your mixing device. IJECTIO PUMP MIXIG SETUP MIXIG MEU.00 ) MIXIG TYPE IJ Mixing Type Use this option when using a primary/secondary injection style piping. This selection will take hot water from the primary loop and inject it into the secondary loop, ensuring proper temperature control in the low temperature system. (IJ/FLO/MOD) Default: IJ MIXIG MEU.00 ) MIXIG TYPE FLO FLOATIG ACTIO VALVE SETUP Mixing Type Use this option when you are using a or 4 way mixing valve. This will run your floating(power open/power close valve) and mix the temperature down in your low temperature system. (IJ/FLO/MOD) Default: IJ MIXIG MEU ) MIXIG TYPE ) MOD TIME ) MI MOD% MIXIG MEU ) MIXIG TYPE ) MOD TIME ) MI MOD%.00 MOD S 0%.00 MOD S 0% Mixing Type Use this option when you need to have a -0VDC signal to run your mixing device. This could be used for a modulating valve or to a VFD, to ensure the proper temperature in the low temperature system. (IJ/FLO/MOD) Default: IJ Mod Time This setting sets the time between the steps when the valve needs to increase or decrease the firing rate. Each step is % for all situations. (S to 40S) Default: S MODULATIG OUTPUT SETUP MIXIG MEU ) MIXIG TYPE ) MOD TIME ) MI MOD%.00 MOD S 0% Minimum Mod % This setting is used to set the lowest modulating level the valve can go down to. This will also be the starting point whenever there is a new demand. (0% to 95%) Default: 0% Page 8

H BX Hydronic Control Version.04 5) HEAT DEMAD SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) MIXIG SETUP 5) HEAT DEMAD 6) C OR Heat Demand This setting indicates that the is in a permanent heat demand. This can be used instead of attaching a thermostat. (Y/) Default: 6) CELSIUS OR FAHREHEIT SETUP MEU.00 ) BOILER SETUP ) DESIG TEMPS ) DHW SETUP 4) MIXIG SETUP 5) HEAT DEMAD 6) C OR Celsius or Fahrenheit Use this setting to change the display format from Celsius ( C) to Fahrenheit (). (/ C) Default: Control Systems Inc. 05 Page 9

DIFFERETIAL SETPOIT MODE H BX Hydronic Control Version.04 Multicolour backlit Display The Multicolour Backlit Display is one of the key features of the Controls stand-alone Control. Depending on which mode of operation is selected the screen colour will change to indicate information about the status of the system. Screen Colors Light Blue - o Heat Demand Red - Heat Demand Status Screen Heat Demand Modulating Level HD DIFF SETPT SETPT STATUS 78 99 TARGET 0 MOD 40% PMP O PMP O PMP DO OT 4VAC COECT POWER MAX HERE 4-0v + A - DO OT COECT POWER HERE 5 BL 6 BL 7 8 9 0 0 L 4 5 6 7 8 9 Heat Demand Input Differential Mod Output Setpoint Setpoint Pump Pump Pump Supply Power 0 VAC Page 0

DIFFERETIAL SETPOIT MODE PROAMMIG GUIDE H BX Hydronic Control Version.04 DIFFERETIAL SETPOIT SETUP ) DIFF ) MOD TIME ) MI MOD 4) C OR SETUP MEU.00 6 S 0% ) Differential Use this setting to set the differential between setpoint s temperature and setpoint s temperature. ( to 00) Default: 6 ) DIFF ) MOD TIME ) MI MOD 4) C OR SETUP MEU.00 6 S 0% ) Mod Time This setting sets the time between each step of the 0-0VDC output when the modulating output needs to increase or decrease. (S to 40S) Default: S ) DIFF ) MOD TIME ) MI MOD 4) C OR SETUP MEU.00 6 S 0% ) Minimum Mod % This setting is used to set the lowest modulation level the modulating output can go down to. It can also be used to set the minimum position on valves. (0% to 95%) Default: 0% ) DIFF ) MOD TIME ) MI MOD 4) C OR SETUP MEU.00 6 S 0% 4) Celsius or Fahrenheit Use this setting to change the display format from Celsius ( C) to Fahrenheit (). (/ C) Default: Control Systems Inc. 05 Page

PUMP SEQUECER MODE H BX Hydronic Control Version.04 STATUS SCREE Multicolour backlit Display The Multicolour Backlit Display is one of the key features of the Controls stand-alone Control. Depending on which mode of operation is selected the screen colour will change to indicate information about the status of the system. Screen Colours Light Blue - o Demand Dark Blue - Pump Running Red - Flow Alarm Warm Weather Shut Down Heat Demand # of Runtime Hours HD WWSD HOURS CYCLES OUTDOOR STATUS H 45 50 TARGET 50H 80 Timed Rotation Target Cycle Rotation Target # of Cycles Currently STG O PMP O PMP O ALARM DO OT 4VAC COECT POWER MAX HERE 4-0v + A - DO OT COECT POWER HERE 5 BL 6 BL 7 8 9 0 0 L 4 5 6 7 8 9 Heat Demand Input Flow Proof Input O/ Outdoor Flow Alarm Pump Pump Supply Power 0 VAC Page

PUMP SEQUECER MODE PROAMMIG GUIDE H BX Hydronic Control Version.04 PUMP SEQUECER SETUP SETUP MEU.00 ) OVERRIDE ) OVERRIDE ) SEQ TIME 4) SEQ CYCLES 5) WWSD 6) C OR 60 SETUP MEU.00 ) OVERRIDE ) OVERRIDE ) SEQ TIME 4) SEQ CYCLES 5) WWSD 6) C OR 60 SETUP MEU.00 ) OVERRIDE ) OVERRIDE ) SEQ TIME 4) SEQ CYCLES 5) WWSD 6) C OR 60 SETUP MEU.00 ) OVERRIDE ) OVERRIDE ) SEQ TIME 4) SEQ CYCLES 5) WWSD 6) C OR 60 ) Manual Override This setting is used to put Pump in manual override. When set to yes, the pump relay is permanently on. (Y/) Default: ) Manual Override This setting is used to put Pump in manual override. When set to yes, the pump relay is permanently on. (Y/) Default: ) Sequencial Time This setting is used to set the rotation time for the pumps. (/ to 40H) Default: 7H 4) Sequencial Cycles This setting is used to set the number of demands that are given before the pumps will rotate. (/ to 40 Cycles) Default: Use caution. Sequencial Time and Sequential Cycles will override each other. Use only one or the other. SETUP MEU.00 ) OVERRIDE ) OVERRIDE ) SEQ TIME 4) SEQ CYCLES 5) WWSD 6) C OR 60 SETUP MEU.00 ) OVERRIDE ) OVERRIDE ) SEQ TIME 4) SEQ CYCLES 5) WWSD 6) C OR 60 5) Warm Weather Shut Down This setting is used for Warm Weather Shut Down. This will turn the pumps off when the outdoor temperature goes above this setting. (5 to 0) Default: 70 6) Celsius or Fahrenheit Use this setting to change the display format from Celsius ( C) to Fahrenheit (). (/ C) Default: Control Systems Inc. 05 Page

DUAL SETPOIT MODE H BX Hydronic Control Version.04 STATUS SCREE Setpoint Current Temperature SETPT SETPT C O C STATUS O TARGET 54 80 0 O O Setpoint Target Setpoint Target Setpoint Current Temperature DO OT 4VAC COECT POWER MAX HERE 4-0v + A - DO OT COECT POWER HERE 5 BL 6 BL 7 8 9 0 0 L 4 5 6 7 8 9 ormally Closed Relay Setpoint s ormally Open Relay ormally Open Relay ormally Closed Relay Supply Power 0 VAC ormally Closed is typically used in a heating logic application. ormally Open is typically used in a cooling logic application. Page 4

DUAL SETPOIT MODE PROAMMIG GUIDE H BX Hydronic Control Version.04 DUAL SETPOIT SETUP ) SP TEMP ) SP DIFF ) SP TEMP 4) SP DIFF 5) LAGTIME 6) C OR ) SP TEMP ) SP DIFF ) SP TEMP 4) SP DIFF 5) LAGTIME 6) C OR ) SP TEMP ) SP DIFF ) SP TEMP 4) SP DIFF 5) LAGTIME 6) C OR ) SP TEMP ) SP DIFF ) SP TEMP 4) SP DIFF 5) LAGTIME 6) C OR SETUP MEU.04 80 6 0 8 M SETUP MEU.04 80 6 0 8 M SETUP MEU.04 80 6 0 8 M SETUP MEU.04 80 6 0 8 M ) Setpoint Temperature This setting is used to set the desired temperature for setpoint. ( to 00) Default: 80 ) Setpoint Differential This setting is used to set the differential for setpoint. ( to 00) Default: 6 6 differential would be above and below the target ) Setpoint Temperature This setting is used to set the desired temperature for setpoint. ( to 00) Default: 0 ) Setpoint Differential This setting is used to set the differential for setpoint. ( to 00) Default: 6 8 differential would be 4 above and 4 below the target ) SP TEMP ) SP DIFF ) SP TEMP 4) SP DIFF 5) LAGTIME 6) C OR ) SP TEMP ) SP DIFF ) SP TEMP 4) SP DIFF 5) LAGTIME 6) C OR SETUP MEU.04 80 6 0 8 M SETUP MEU.04 80 6 0 8 M 5) Lagtime This setting is used to set lagtime. When this is set above zero, the control will wait the specified amount of time before turning the relays on. (0M to 40M) Default: M 6) Celsius or Fahrenheit Use this setting to change the display format from Celsius ( C) to Fahrenheit (). (/ C) Default: Control Systems Inc. 05 Page 5

STAGIG MODE WIRIG DIAAMS ) Single On/Off boiler with DHW pump M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A Use Aquastat when no thermistor is available in the tank DHW Outdoor Pump DHW Pump System Pump 4 V AC C R 0 V AC L ) Two On/Off boilers with DHW pump Wire Thermostat W R C 4VAC DO OT COECT POWER MAX HERE -0v + - A DO OT COECT 4 5 6 7 8 9 4 BL BL 7 8 9 0 0 L A DHW DHW Pump Use Aquastat when no thermistor is available in the tank Outdoor System Pump 4 V AC R C 0 V AC L Page 6

) Three On/Off boilers M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A DHW Use Aquastat when no thermistor is available in the tank Outdoor System Pump 4 V AC C R 0 V AC L 4) Single modulating boiler with DHW pump M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A DHW Pump DHW Pump Use Aquastat when no thermistor is available in the tank Outdoor System Pump Modulating Output 4 V AC C R 0 V AC L Page 7

MIXIG MODE WIRIG DIAAMS ) Single O/ boiler with injection pump M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A System Pump System Pump Use Aquastat when no thermistor is available in the tank Outdoor Injection Pump 4 V AC C R 0 V AC L ) Single modulating boiler with injection pump M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A System Pump System Pump Use Aquastat when no thermistor is available in the tank Outdoor Injection Pump Modulating Output 4 V AC C R 0 V AC L Page 8

) Single On/Off boiler with injection pump and DHW pump M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A Use Aquastat when no thermistor is available in the tank System Outdoor DHW Pump System Pump Injection Pump 4 V AC C R 0 V AC L 4) Single modulating boiler with injection pump and DHW pump M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A System DHW Pump System Pump Use Aquastat when no thermistor is available in the tank Outdoor Injection Pump Modulating Output 4 V AC C R 0 V AC L Page 9

5) Two On/Off boilers with injection pump M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A System System Pump Use Aquastat when no thermistor is available in the tank Outdoor Injection Pump 4 V AC C R 0 V AC L 6) Single On/Off boiler with a floating action valve (power open/power close) M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A Use Aquastat when no thermistor is available in the tank System Outdoor System Pump Valve Up Valve Down 4 V AC C R 0 V AC L Page 0

7) Single modulating boiler with a floating action valve (power open/power close) M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A System Use Aquastat when no thermistor is available in the tank Outdoor System Pump Modulating Output Valve Up Valve Down 4 V AC C R 0 V AC L 8) Single On/Off boiler with modulating valve output (-0VDC) M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A System Pump Use Aquastat when no thermistor is available in the tank Outdoor System Pump Modulating Valve Output 4 V AC C R 0 V AC L Page

9) Single On/Off boiler with modulating valve output (-0VDC) and DHW pump M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 A Use Aquastat when no thermistor is available in the tank System Outdoor DHW Pump System Pump Modulating Valve Output 4 V AC C R 0 V AC L Page

DIFFERETIAL MODE WIRIG DIAAM ) Differential Setpoint M-000 Thermostat A DO OT COECT 4 4V AC 4VAC DO OT COECT POWER MAX HERE 4-0v + - A BL BL DO OT COECT 7 8 9 0 0 L 4 5 6 7 8 9 Setpoint Setpoint Pump Pump Pump Differential Mod Output 4 V AC C R 0 V AC L Page

PUMP SEQUECER MODE WIRIG DIAAM ) Pump Sequencer 4VAC DO OT COECT POWER MAX HERE -0v + - A DO OT COECT 4 5 6 7 8 9 4 BL BL 7 8 9 0 0 L Demand Input Alarm Output FP Outdoor Pump Flow Proof Input Pump 0 V AC L Page 4

DUAL SETPOIT MODE WIRIG DIAAM ) Dual Setpoint 4 V AC MAX 4-0v + A - DO OT COECT POWER HERE BL 5 BL 6 7 8 9 0 0 L 5 A 4 5 5 A 6 7 5 A 8 9 Setpoint Setpoint ormally Closed ormally Closed ormally Open ormally Open 0 V AC L Page 5

H BX Hydronic Control Version.04 OTES Page 6

Limited Warranty H BX Hydronic Control Version.04 Controls warrants each of its products to be free from defects in workmanship and materials under normal use and service for a period of 4 months from date of manufacture or months from date of purchase from an Authorized Dealer, if within the above documented period after date of manufacture. If the product proves to be defective within the applicable warranty period, on its sole discretion will repair or replace said product. Replacement product may be new or refurbished of equivalent or better specifications, relative to the defective product. Replacement product need not be of identical design or model. Any repair or replacement product pursuant to this warranty shall be warranted for not less than 90 days from date of such repair, irrespective of any earlier expiration of original warranty period. When provides replacement, the defective product becomes the property of Controls. Warranty Service, within the applicable warranty period, may be obtained by contacting your nearest Controls office via the original Authorized Agent and requesting a Return Material Authorization umber (RMA #). Proof of purchase in the form a dated invoice/receipt must be provided to expedite the issuance of a Factory RMA. After an RMA number has been issued, the defective product must be packaged securely in the original or other suitable shipping package to ensure that it will not be damaged in transit. The RMA number must be visible on the outside of the package and a copy included inside the package. The package must be mailed or otherwise shipped back to with all costs of mailing/shipping/insurance prepaid by the warranty claimant. Any package/s returned to without an approved and visible RMA number will be rejected and shipped back to purchaser at purchaser s expense. reserves the right, if deemed necessary, to charge a reasonable levy for costs incurred, additional to mailing or shipping costs. Limitation of Warranties If the product does not operate as warranted above the purchasers sole remedy shall be, at s option, repair or replacement. The foregoing warranties and remedies are exclusive and in lieu of all other warranties, expressed or implied, either in fact or by operation of law, statutory or otherwise, including warranties of merchantability and fitness for a particular purpose/application. neither assumes nor authorizes any other person to assume for it any other liability in connection with the sale, installation maintenance or use of Controls products. shall not be liable under this warranty; if its testing and examination discloses that the alleged defect in the product does not exist or was caused by the purchasers or third persons misuse, neglect, improper installation or testing, unauthorized attempts to repair or any other cause beyond the range of intended use, or by accident, fire, lightning or other hazard. Limitation of Liability In no event will be liable for any damages, including loss of data, loss of profits, costs of cover or other incidental, consequential or indirect damages arising out of the installation, maintenance, commissioning, performance, failure or interruption of an product, however caused and on any theory of liability. This limitation will apply even if has been advised of the possibility of such damage. Local Law This limited warranty statement gives the purchaser specific legal rights. The purchaser may also have other rights which vary from state to state in the United States, from Province to Province in Canada and from Country to Country elsewhere in the world. To the extent this Limited Warranty Statement is inconsistent with local law, this statement shall be deemed modified to be consistent with such local law. Under such local law, certain disclaimers and limitations of this statement may not apply to the purchaser. For example, some states in the United States, as well as some governments outside the United States (including Canadian Provinces), may: Preclude the disclaimers and limitations in this statement from limiting the statutory rights of a consumer (e.g. United Kingdom); Otherwise restrict the ability of a manufacturer to enforce such disclaimers or limitations; or Grant the purchaser additional warranty rights which the manufacturer cannot disclaim, or not allow limitations on the duration of implied warranties. Control Systems Inc. 05 Page 7

Phone: + (40) 70-009 Fax: + (40) 70-0054 Email: inf o @ hbxcontrols.com Web: www.hbxcontrols.com Toll Free Technical Support: + (855) 554 669 Control Systems Inc. 456 - th Avenue SE Calgary, AB Canada TC K Control Systems Inc. 07