Accumulators - Suction Line

Similar documents
FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit

REFRIGERATION PRODUCTS

Sealed Type Liquid Line and Suction Line Specifications

THERMOSTATIC EXPANSION VALVES

Filter Driers with Replaceable Core

OIL SEPARATORS APPLICATIONS

Research Design Quality Value Service Experience

Dehydrators and Filters

R E D I C O N T R O L S

Refrigeration Supplies

DEHYDRATORS AND FILTERS

Research Design Quality Value Service Experience

Copeland Scroll Condensing Units for the Food Service Market

APPLICATION and INSTALLATION

for Valve Types P-H-M-V-W-D-A

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

12 In Row. Installation Manual. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 6, Vertical Floor-Mount Units

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

Series 6, Vertical Floor-Mount Units

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

WineZone Ceiling Mount Ductless Split 15

PattonPak Stream Condensing Units

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

OPERATING INSTRUCTIONS

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

REFRIGERATION PRODUCTS

REFRIGERANT CHANGEOVER

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Commercial High-Efficiency Condensing Units

LINE COMPONENTS VALVES

Kirby Commander Condensing Unit

MACH N-407 Heat Pump Air-Cooled Chiller

TURBOIL (welded) / TURBOIL-F (flanged)

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

DESIGN STANDARDS SECTION 15600

Typical Piping Diagram

500 EX Fusion Compressor Series

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Check valve Types NRV and NRVH

RCY. Filter drier receiver units 4.1. Refrigeration & Climate Components Solutions. n Applications

T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount.

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

September 2016 AE Application Guidelines for Copeland CS**KIE Compressors in Ice Machines AE4-1421

horizontal air discharge outdoor discus condensing unit

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Suction Accumulators. Introduction. Suction Accumulators

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

ENTHALPY HERMETIC CONDENSING UNITS

TOSHIBA AIR CONDITIONING

Sporlan Valve Division Parker Hannifan/CIC Group

VCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications

Thermostatic Expansion Valves Type TR 6

Call us today! (800)

EN-CV: LHCb SciFi Common chiller. Martin Doubek September 25, 2017

These valves can also be ordered as a bidirectional valve, allowing control of flow in both directions for use on heat pump applications.

Danfoss Scroll for Refrigeration MLM / MLZ

Air-Cooled Condensing Units with Compact Screw Compressors

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

General information on refrigerant controllers

Contour TM Screw Compressors

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

MAC N-407 Air-Cooled Chiller

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

208 For more information visit our website at

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CHECK VALVES INSTALLATION

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

64 bar. DCY-P6 / 64 bar (928 psig) Anti-acid filter driers 1.9. subcritical. Refrigeration & Climate Components Solutions.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

ELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL

Brazed heat exchangers

Installation Instructions

T E C H N O L O G I E S P R O D U C T C A T A L O G

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Catalog 301. Condensed Catalog of Sporlan Products

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

REFRIGERATION PRODUCTS

Installation Manual BCS2000/3000

RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Process glycol chillers

Kramersaver Air Cooled Condensing Units

COMPRESSOR SPECIFICATIONS

Auto Air Conditioning Compressors GENERAL CATALOGUE

DANFOSS OPTYMA PLUS INVERTER UNITS

Owner s Manual Therma-Stor II Heat Recovery System

T P A 120 S 4 S N 1 Y

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Thermostatic Expansion Valves

Reverse Cycle Chiller Models CHA24, 36, 48 & 60

PULSE WIDTH MODULATING VALVES

General Service Bulletin

Transcription:

ACCUMULATORS Accumulators - Suction Line kw Cap at Evap. Temp. -6 C Size Connection R22 R404A / R507C F0804 1/2" ODS Vertical 4.6 4.8 F0805 5/8" ODS Vertical 6.9 7.2 F0806 3/4" ODS Vertical 9.2 9.6 F0807 7/8" ODS Vertical 16.7 17.5 F0809 1 1/8" ODS Vertical 27.0 28.3 F0811 1 3/8" ODS Vertical 43.1 45.2 F0813 1 5/8" ODS Vertical 65.3 68.4 F0121 2 1/8 LCY 1817 S/MMS 125 130 F0125 3 1/8 LCY 5025S 288 300 * These accumulators should not be used below -18 C without supplementary heating to ensure oil return - see information on Heater Elements below. Accumulator Factors for Determining Capacity Evap. Temp. -18 C -30 C Factor.68.41 Note: To find kw capacity for the other evaporator temperatures, multiply factor X rating listed at -6 C Selection of a suction line accumulator should be made on the basis of the following capabilities: The accumulator should have an adequate liquid holding capacity - normally not less than 50% of the system charge. The accumulator should perform efficiently without excessive pressure drop to the system. The accumulator should return oil at the proper rate and under a range of conditions of load. The selection of the suction line accumulator should not be based on line size, but on its ability to perform well within the limits described above. Consequently the suction line accumulator will not necessarily have the same connection size as the compressor suction line. Heater Elements To Suit Accumulators Elements must be used when operating under -18 C. The element adds heat to oil separators in order to prevent migration of refrigerant to the vessel during the off cycles of the compressor. Heater elements also add heat to suction line accumulators, to keep the oil warm, permitting oil return to the compressor on low temperature applications. Refer to page 127. 126

OIL CONTROL SYSTEMS Oil Separators Model ODS Nominal Capacity kw * Dimen. (mm) R22 R404A H x D -5 C -25 C -5 C -25 C F0869 S-5581 3 8" 4.7 3.3 4.7 3.3 210x102 F0070 NS-1004 1 2" 6.7 6.0 6.7 6.0 260x102 F0072 NS-1005 5 8 18.6 17 18 15.8 362x102 F0074 NS-1007 7 8 27.4 25.7 28.2 25 450x102 F0076 NS-3009 1 1 8 35.6 33.5 36.8 32.7 533x102 F0078 NS-3011 1 3 8 46 42.8 46.5 41 540x102 F0080 NS-3013 1 5 8 61.6 58 63.6 57.5 472x153 F0882 S-5694 2 1 8 101.7 93.8 103.6 92.5 486x158 Henry Helical Oil Separators/Oil Reservoirs Model ODS Nominal Capacity kw * Dimen. (mm) R22 R404A H x D -5 C -25 C -5 C -25 C F0347 S-5392 1 5 8" 63.3 56.3 66.8 52.7 890x150 F0348 S-5394 2 1 8" 105.5 87.9 109.0 84.4 890x150 F0351 S-5302 2 1 8" 123.1 137.1 109.0 144.2 640x200 F0352 S-5303 2 5 8" 281.3 249.7 291.9 225.0 750x250 All capacities shown are based on 37.8 C condensing temperature with an 18.3 C suction gas temperature. Dimensions are Height x Diameter in millimetres. Replacement Float F0330 F0331 A1900-30 Float Assembly suits S-5200 and S1900 series 2-023-001 Float Valve Gasket AC & R Heater Elements Heat elements add heat to oil separators to prevent migration of refrigerant to the vessel during off cycles of the compressor. Also suitable for AC & R accumulators. F0084 S-9111 4 diameter 220 volt 25 Watt Suits S-5520, S-5180 series oil separators 127

OIL CONTROL SYSTEMS Trax Oil Control Systems F0092 TRAX TR3201 Oil Level Control System Oil Reservoir And Accessories F0052 Henry S-9130 Adjustable Oil Level Regulator with 3/8 MF SAE equalisation connection 90 psi max. differential. Replaces S9191, S9131, S9134, S9133, S9190, & S9193 F0052 F0053 A C & R S-9108 Oil Reservoir (4 US gallon capacity) 15 litres The oil reservoir is the holding vessel for stand-by oil necessary for the operation of the oil control system. F0055 A C & R S-9109 Oil Reservoir (2 US gallon capacity) 7.5 litres 3/8 Flare Rotalock Valve F0057 Henry S-9104 Reservoir Pressure Valve 3/8 Flare Connections This valve will maintain a 5lb. positive pressure differential at the oil reservoir over the crankcase pressure ensuring an adequate oil supply to the oil level regulator. F0053/5 F0062 Henry S-9104H High Pressure Check Reservoir Valve Some parallel compressor systems have a satellite compressor which maintains a higher suction pressure than the other compressor system. The S-9104H provides a 20 lb positive pressure in the oil reservoir for this application. F0057/62 F0058 Henry S-9241 Oil Level Regulator Shut-Off Valve 3/8 MF x 3/8 FF Swivel Connection S-9106-vertical mount This valve allows each oil level regulator to be isolated if service is required on a compressor. Vertical model. For equalization lines on S-9130 regulator. F0060 F0059 Henry 3/033/212 Sight Glass Adapter 3 bolt 1.7/8 to suit Copeland 8R Series, Frascold W Series A C & R S-9105 Oil Line Strainer 3/8 MF Flare- 100 Mesh 11 sq in. This strainer protects the oil level regulator by removing foreign matter. The strainers mesh screen provides adequate straining with low pressure drop. F0058 F0066 F0067 Oil Filters *Henry S-4005 POE Oil Filter Drier 3/8 MF. 6 micron filtration Removes foreign material from the oil as it passes through the filter. Henry S-9106H Horizontal Shut-Off Valve 3/8 MF x 3/8 FF, swivel connection. Horizontal model for use where space is limited. F0059 F0066 SP2600 Sporlan OF-303 Oil Filter 3/8" Flare SP2601 Sporlan OF-303-BP Oil Filter W/Bypass 3/8" Flare F0067 128

RECEIVERS VERTICAL LIQUID Vertical Receivers Model Pump Down Capacity Kg @ 80% Sweat Connections Rotalock Valves R22 R134a R404A Supplied Inlet Outlet Inlet Outlet Yes/No PRV Required Yes/No F0261 RLVCY15 1.4 1.4 1.3 1 4 1 4 3 4 3 4 N Y F0264 RLVCY30 2.8 2.8 2.4 3 8 3 8 3 4 3 4 N Y F0280 RLVCY40 3.8 3.8 3.3 3 8 3 8 3 4 3 4 N Y F0284 RLVCY60 5.5 5.5 4.9 1 2 1 2 1 1 N Y F0292 RLVCY120M 11.0 11.0 9.8 5 8 5 8 1 1 4 1 1 4 N Y Receivers have fittings for Rotalock valves. Also the same connection allows for a solder connection as above. Gaskets are 3/4 : H1103; 1 : H1104. Mounting is by single M10 stud (F0261-F0280) or M12 (F0284). Pressure Relief Devices The requirements for the installation of pressure valves into pressure vessels are proscribed within AS/NZS1677.2.1998 and its amendments. Viz; 1. Vessels of less than 300L internal gross volume: Vessels containing more than 1.5kg of Group B2 refrigerants: or 1.0 Kg of Group A3 refrigerants must be fitted with 1 or more mechanical pressure relief devices. 2. Vessels of greater than 300 L internal gross volume: Pressure vessels which may contain liquid refrigerant and which may be shut off from other parts of the refrigeration system shall be protected by means of two pressure relief valves. If the vessel is on the high pressure side of the system, the pressure relief valves shall be controlled by a changeover device. 129

DRIERS Sporlan Driers - Flare Liquid Line Driers - Sporlan Model Size Cu In SP3001 CATCH-ALL 032 1/4" MF 3 SP3002 CATCH-ALL 052 1/4" MF 5 SP3003 CATCH-ALL 082 1/4" MF 8 SP3004 CATCH-ALL 162 1/4" MF 16 SP3008 CATCH-ALL 053 3/8" MF 5 SP3009 CATCH-ALL 083 3/8" MF 8 SP3011 CATCH-ALL C163 3/8" MF 16 SP3012 CATCH-ALL 303 3/8" MF 30 SP3015 CATCH-ALL 084 1/2 MF 8 SP3017 CATCH-ALL 164 1/2" MF 16 SP3018 CATCH-ALL 304 1/2" MF 30 SP3022 CATCH-ALL 165 5/8" MF 16 SP3023 CATCH-ALL 305 5/8" MF 30 SP3025 CATCH-ALL 415 5/8" MF 41 Sky Driers - Flare Liquid Line Driers - Sky Model Size Cu In H0125 FL 306 3/4" MF 30 Sporlan Driers - Sweat Model Size Cu In Liquid Line Driers - Sporlan SP3071 CATCH-ALL 032S 1/4" SWEAT 3 SP3072 CATCH-ALL 052S 1/4" SWEAT 5 SP3073 CATCH-ALL C082S 1/4" SWEAT 8 SP3078 CATCH-ALL C053S 3/8" SWEAT 5 SP3079 CATCH-ALL C083S 3/8" SWEAT 8 SP3081 CATCH-ALL C163S 3/8" SWEAT 16 SP3085 CATCH-ALL C084S 1/2" SWEAT 8 SP3087 CATCH-ALL C164S 1/2" SWEAT 16 SP3092 CATCH-ALL C165S 5/8" SWEAT 16 130

SUCTION FILTERS Mueller Driers - Sweat Model Size Cu In Liquid Line Driers - Mueller H0130 SD 417 7/8" SWEAT 41 SF Suction Line Filters The Sporlan SF Suction Line Filter protects the compressor from dirt. It is designed with an optional relief feature that opens if the filter plugs. It also has a full flow design for low pressure drop. It is suitable for use with all brazing alloys and maximum corrosion resistance. SP3155 SP3156 SP3157 SP3159 SP3161 SP3163 Sporlan Suction Filter SF-285-T 5/8" SW Sporlan Suction Filter SF-286-T 3/4" SW Sporlan Suction Filter SF-287-T 7/8" SW Sporlan Suction Filter SF-289-T 1.1/8" SW Sporlan Suction Filter SF-4811-T 1.3/8" SW Sporlan Suction Filter SF-4813-T 1.5/8" SW Suction Line Filter Driers The Suction Line Filter Drier has been specifically designed for system clean-up after a burn out or any time system cleanliness is questionable. High acid and water absorption. For use with HCFCs, HFCs, and lubricants that go with them. Not recommended for permanent use. Once the suction line filter drier has completed its clean-up procedure it should be replaced with a suction line filter. Model Filter Area Sq. In. Volume Cu. In. Burn-Out Driers H0306 Mueller A17224 1/2" SW 26 16 H0308 Mueller A17227 5/8" SW 26 16 H0311 Mueller A17225 1/2" MF 26 16 H0312 Mueller A17226 5/8" MF 26 16 H0313 Mueller A17228 3/4" SW 26 16 H0314 Mueller A17229 7/8" SW 26 16 H0315 Mueller A17230 1.1/8" SW 26 16 H0316 Mueller A17231 1.1/8" SW 52 30 Directional Liquid Line Driers (directional/ bi-directional) Model H0247 MA Line D111 12 gram XH9 Service Drier 1/4 ODS inlet - capillary connection outlet with separate charging port H0250 MA Line D109 10 gram XH9 Service Drier 1/4 ODS inlet - bidirectional H0256 MA Line D114 30 gram XH9 Service Drier 5/16 in 1/4 outlet Note: Driers with XH9 desiccant are suitable for all refrigerants including blends and R134a 131

DRIERS Reversible Heat Pump Driers Sporlan Code SP3240 HPC-103 Heat Pump Drier 3/8" MF SP3241 HPC-104 Heat Pump Drier 1/2" MF SP3250 HPC-103S Heat Pump Drier 3/8" OD SP3251 HPC-104S Heat Pump Drier 1/2" OD SP3261 HPC-165SHH Heat Pump Drier 5/8" OD Refillable Shells - Suction Line SP3240 Model Size Core Max. Rating kw Med Temp Max. Rating kw Low Temp SP3462 Sporlan RSF-489T 1 1/8" ODS 1 core 25.7 9.9 SP3463 Sporlan RSF-4811T 1 3/8" ODS 1 core 31.3 12 SP3464 Sporlan RSF-4813T 1 5/8" ODS 1 core 33.8 12.7 SP3465 Sporlan RSF-4817T 2 1/8" ODS 1 core 95.0 59.8 SP3466 Sporlan RSF-4821T 2 5/8" ODS 1 core 123.0 80.9 SP3471 Sporlan RSF-9621T 2 5/8" ODS 2 core 141.0 91.4 SP3472 Sporlan RSF-9625T 3 1/8" ODS 2 core 193.0 123.0 Sporlan RSF Suction Driers: kw are based on R404A Refillable Shells - Liquid Line Model Size Core Max. Rating kw Med Temp Refillable Shells - Liquid Line - Carly Max. Rating kw Low Temp SP3405 Sporlan C-485G 5/8" ODS 1 Core 35.2 26.4 SP3407 Sporlan C-487G 7/8" ODS 1 Core 52.8 35.2 SP3416 Sporlan C-967G 7/8" ODS 2 Core 87.2 52.8 SP3408 Sporlan C-489G 1 1/8" ODS 1 Core 52.8 35.2 SP3417 Sporlan C-969G 1 1/8" ODS 2 Core 1/4" FPT 101.9 87.9 connection SP3419 Sporlan C-9611G 1 3/8" ODS 2 Core 123 87 SP3113 Sporlan C-14411G 1 3/8" ODS 3 Core 1/4" FPT 137.1 123 connection SP3420 Sporlan C-9613G 1 5/8" ODS 2 Core 120 106 SP3429 Sporlan C-14413G 1 5/8" ODS 3 Core 176 123 SP3416 132

DRIERS Briquettes To Suit Refillable Shells - Interchangeable Model SP3702 Sporlan RC-4864 Catch-All core standard. SP3703 Sporlan RC-4864-HH Catch-All activated charcoal core. SP3704 Sporlan RCW-48 Catch-All High Water capacity core. SP3706 Sporlan RC-10098 Catch-All Core Suction Line Filter Elements To Suit Above Shells Model Sectional View Drier Core SP3710 Sporlan RPE-48-BD Pleated Suction Line Filter Element Gaskets Model SP3710 SP3725 1291-001 Gaskets AS-1704 SP3725 133

SIGHT GLASSES Liquid/Moisture Indicating - Sporlan See-All Sight Glasses SP2700 SP2703 SP2710 SP2717 SP2701 SP2704 SP2711 SP2709 SP2702 SP2705 SP2712 SP2718 SP2722 SP2723 SP2724 SP2728 1 4" MF 3 8" MF 1 2" MF 5 8" MF 1 4" MF FF 3 8" MF FF 1 2" MF FF 5 8 MF x SN 1 4" ODS 3 8" ODS 1 2" ODS 5 8" ODS 7 8" ODS 1 1 8" ODS 1 3 8" ODS 2 1 8 ODS Sight Glasses For Soldering On To Pipe H0770 H0771 H0772 H0773 1 3 8" SW 1 5 8" SW 2 1 8" SW 2 5 8" SW * Note: Listed sight glasses are suitable for all refrigerants except ammonia refrigeration systems. 134