Nokeval. No Manual. Model 2026 Totalizer / Batch controller for analog inputs

Similar documents
Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

STRAIN GAUGE TRANSMITTER 6841

Temperature Controllers

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

eed quality electronic design USER s MANUAL

Process & TeMPerATUre UniversAl input DigiTAl MeTers

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Product Manual SZ1145

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Product Manual SZ1144

Pioneer-R16 Gas Monitor Operator s Manual

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Software Version 2.01 LEVEL MONITOR MODEL 220

Carbon Monoxide Transmitter

Installation Manual Tracker 221

F4 Process Controller Installation and Operation Guide

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

EasyTronic III MANUAL SERVICE

UDC 700 Universal Digital Controllers and Indicator Specifications

Dryer Controller M720

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

LD5-TMR and LE5-TMR Large Digit Timer Display Operation and Instruction Manual

General Purpose IO Technical Manual

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

User Manual. Dryer Controller M720

OVEN INDUSTRIES, INC.

Pump-Up Controller MODEL 4062

Nov 08 PRODUCT SPECIFICATION SHEET

02/11/2015

CLEANROOM MONITOR CR3A Network - Installation Instructions

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

DIGITAL METERS Large Display Temperature Meters Instruction Manual

SHIMADEN DIGITAL INDICATORS

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Pump-Down Controller MODEL 4052

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ST Wiring diagram. Product description. Standard temperature controller. Order number

Analog Room Pressure Monitor RPC Series

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Table of Contents SECTION PAGE

SCAN20 Series Gas Detection Controller

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

NT DUAL CHANNEL DISPLAY. User Guide

02/11/2015

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

2-wire Passive Intelligent Loop (LED) Display Meter

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Mark 25 Ultrapure Water Conductivity Analyzer

TER Active Room Temperature Sensor (Controller),

Oxygen (O2) Single-Point Gas Detection System

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

2-wire Passive Intelligent Loop (LED) Display Meter

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

SCAN200E USER S MANUAL

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

1. Quick start-up guide

Electronic Temperature Controller 70304,

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Universal display DA9602

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Constant voltage 3-phase rectifier.

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions

Module Features are-configurable, no module jumpers to set

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

VERTEX F4 Instruction Manual

All-In-One Wireless Security System V1.0. Model #: MG-6060

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Digital Meters 2002 SINCE 1974 CATALOG. Level Flow Temperature Pressure. PRECISION DIGITAL CORPORATION

AutomationDirect. PC35 Configuration Sheet

Internet enabled RTU/Data loggers. ilog-gsm/edm: Tutorial Vers /2.0 August 2006

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

RS485 MODBUS Module 8AI

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

ETO 2 - Controller for ice and snow melting

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Sintrol Snifter A2 EX. Manual. Version 1.2.3

LevelSET S GSM Functionalities Instructions for Commissioning and Use

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

ESSEX ENGINEERING CORPORATION

INSTALLATION INSTRUCTIONS

FLOW CONTROLLER TYPE S/601

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions

The range of ATR243 controllers comes in three versions. Refer to the table below to easily select your preferred model.

Transcription:

No 00 Nokeval Manual Model 0 Totalizer / Batch controller for analog inputs

Contents Rate / Batch controller 0 for analog inputs... Dimensions... Front panel indicators and buttons... Configuration... Reset of configuration parameters... Setting of alarm value... Setting of alarms... Selection of input... 7 Alarm functions... 8 General description... 8 Alarm card connections... 8 Alarm settings by front panel keys... 8 Selection of alarm card and relay-function settings... 9 Main menu... 9 Shifting in menu... 9 Minimum and maximum value memory... 0 Reset memeory... 0 Setting of secret codes (Programming stage/ alarms)... 0 Terminal connections... Current intput 0/..0 ma... Voltage input 0-0V... Card slots... -wire -0 ma... Panelmeter 000 construction... 000 series input and option cards:... Modular indicator serie 000... Manufacturer: Nokeval Oy Yrittajakatu 700 Nokia, Finland Tel. +8 800 Fax. +8 0

Rate / Batch controller 0 for analog inputs Input signal 0/-0 ma, mv or 0-/0V Kumulative counter (quantity) Mass flow display according to weighing Up or down count Rate/batch operation digit display 999999 Counter non-volatile memory Scalable display One alarm level for batch function Front panel protection IP Sensor supply VDC, max. 0 ma Power supply 90..0 VAC or.. VDC Counter 0 assorts as volume counter or Batch contoller for flowmeters. Up or down counter has -digit red or green display. Display scaling indicates flow rate corresponding to one V/mA in time unit. Display memory (optional) stores calculated value for one week after power brake. You may use the counter as a batch controller by setting alarm value corresponding desired batch volume. Optional output relay changes its stage when alarm level is reached. You can start new count by resetting counter by remote contact or configure unit to stars automatically new batch. You may also determine start level (START) from which you can count down (empty) or up (filling). Configuration stage gives user the possibility to specify what values can be seen in display. Alternatives are rate-of-change (flow rate), totalizer (total flow) or scaled value of the input. User may change the display between two alternatives by -key. Calculated amount is set by front panel keys. Front panel protection is IP and meter can be mounted to cabinet door without protection cover. Nokeval makes counter also for pulse sensors, model 0, separate data sheet available. Typical application Example: Dose 00 litres/ batch. Display scaled to litres from sensor which output is, litres / ma/ min -0 ma 00.0 * Dosage relay Reset and start Output relay closes valve when counter reaches setvalue. Reset opens relay and opens dosing valve. Flow sensor -0 ma Flow rate e.g., litres/ma/min Valve Closing contact when new barrel ready for fill up Quantity t Valve

0 Technical specifications: Input Display scaling Input resistance Accuracy Linearity Supply for sensor VDC, max. 0 ma 0..0 ma,..0 ma 0.., 0..0V 0, 0, 00, 000 mv On whole display range current 0 ohm voltage Mohm 0.0% FS 0.00% FS Display scaling Number of digits per one ma in time unit. Time setting in seconds Count direction Up or down. Direction changed by converting input signal. Mass flow display of weighing sensor alteration Fillng or emptying rate container according to weighing sensor. Counts alternation between two measurement in time unit. Display e.g. ton/h (rate-of-change = Flow). Function of output relay Alarm relay is set by front panel keys. Only one relay is available for totalizer function, batch controller. Dosage function (batch) When set point is reached output relay is activated and will be reset only by remote reset and that resets at the same time the display. Dosage can be started from any value up- or downwards. Output relay is mounted to additional slot. Relay contacts max. 0 VAC, A, alternatively logic relays, 0V, 0, A. Display memory: Add- on card 000-MEM stores display for one week in case of power brake General Input filter Digital, freely adjustable AD-conversion bits ( 000) Temperaturestab. 0,000 %/ C Display -num. bright red LED, digit height. mm Power 8...0 VAC or...0 VDC/ VAC Power demand VA Front panel protection IP with gasket Weight 0 g Optional: Field enclosure Type specification 000IP- 0-REL-MEM-VDC 0 red display 0GR green display Relay card REL Memory card MEM Power - VDC, VAC or 8-0VAC Optional add-on cards: Memory 000-MEM (for slot B) Relay card for relays 000-REL (for slot C) Mother board has two slots (B and C) for add-on cards. Display reset Automatically according to the alarm border or by outside key from 000-MEM card. Dimensions ø,0 9 0 case corners have pins which help installation. Pins centralizes meter into panel cut out made with DIN-tool 8 Panel cut out. (h) x 90. (w) mm Gasket (IP) 0

Front panel indicators and buttons M min memory led M max memory led Conf-light indicates program stage Alarm lights A..A. With -keys You can move on or change numbers and values in programming menu. 0.0 * Another measuring value can be viewed by pressing the -button, the follwing alternatives can be selected in programming stage: (See closer in chapter programming). Rate-of-change value (flow). Scaled display (function de_nor selected). Scaled display (e.g...0 ma = 0..00,0%). Rate-of-change value (function nor_de selected). Totalizer Scaled display (function to_nor selected). Scaled display. Totalizer (function nor_to selected) Configuration You can enter configuration stage by pressing two seconds and -keys at same time. In program stage f. ex. scaling of display, sensor selection and alarm mode are chosen. See closer in chapter programming. Checking of alarm value First pressing of key shows setpoint of alarm one (A), correspondingly second pressing shows setpoint of alarm two (A) etc. Alarm indication light blinks in display informing that alarm level is displayed (if you do not touch keys during 8 seconds display returns to normal state automatically). Preventing of entering alarms (secret code) If you have set secret code for alarms you must feed it before you can change alarms (see chapter settings of secret codes Page 8). Change of alarm value See chapter Alarm settings by front panel key Page 8. Reset of configuration parameters Forgotten secret code may be reset by connecting power supply and pressing, and -keys at same time. Then you can enter configuration stage by keys. Change secret code and exit by SAVE. Setting of alarm value You can set alarm value by -keys number by number. Setting starts from largest number from left to right. You may go to next number by -key. Exit by -key. Number setting 00.00 Numbers 0...9 and, (decimal)

Configuration menu functions + * Input You can enter configuration stage by pressing two seconds and keys at same time. By arrow keys you can move upwards and downwards in main menu. By pressing key you can enter configuration stage at wished point. From setting stage you can skip direct to save stage or to previous level with -key. InPut DEC Input selection. See chapter 'Selection of input'. Decimal selection. Select.. Display scaling whit minimum input signal. e.g. ma. Counting downwards the display s minimum value is being set for negative (-). ok for e.g. page 7. (Zero shift for non scalable inputs) Display scaling whit maximum input signal. e.g. 0 ma. Counting downwards the maximum value of the display is being set for negative (-). ok for e.g. page 7. (multiplier function for mv- and R inputs) OPErAt Normal display display with *-button FL_nor Rate-of-change (flow rate) Scaled display Empty (-) 0- ma, Fill (+) -0 ma e.g...0 ma = 0..00,0% nor_fl Scaled display without time factor Rate-of-change (Flow/time unit) to_nor Totalizer, e.g. litre/ma/h Scaled display nor_to Scaled display Totalizer TimE StArt Halt reset FiLt disp PEAK CALib SEtCod Counting time in seconds, e.g. 00 litres / ma /min, set time to 0 s (= min). Display value where counting starts (batching). Default value = 0. When counting downwards display will show negative values if the Start value is set to zero. Halt value prevents counting under this display value (posive). By giving any negative value, totalizer can be counted also down when input is under w -value (eg. < ma). For example: Scale -0 ma=0-000, Halt=0 (. ma), counting only between 0...000. Undo reset Return without resetting the totalizer value (counter) Totalized value reset to Start-value settinga (new batch) Press and hold -button for seconds. See also remote reset, page 0. Digital filter for input signal (damping) selectable 0,0...0 (.0= no filter) 0. = factory setting = new and 8 old values = display update time /s. 7= /s. (average of 7 measurements) Min/max function: On=enabled, Off=disabled Indicators M=min, M=max For factory settings Secret code settings ( back): ALCod= Code for alarm settings CFCode= Code for configuration. See also section 'Secret code setting.

Slot b Slot c SAVE Undo Alarm level setting. See also section 'Alarm functions'. Alarm level setting. See also section 'Alarm functions'. Save with key and exit from configuration Undo changes and exit from configuration Example downwards counting Typical downwards counting application is emptying of container. Normally in the container has 000 litres of water. When you empty it, it is necessary to know how much water is discharged. In the bottom of container is flow meter, which has a scaling of 0..00 litres / min and output signal of..0 ma. Set follows: = 0, = -00, Start = 000, Time = 0. (By -value +00 counting would start upwards). Selection of input Units accept input from below list. Move with arrows into desired input and select with *-key. Default selection is -0 ma. You can enter configuration stage by pressing two seconds and keys at same time. + * Input Input selection Voltage and ma-inputs mv mv 00 mv 000 mv 00 mv 000 mv mv-input accepts both Bibolar* and Unipolar** * Bibolar e.g. ± mv ** Unipolar e.g. 0- mv Unipolar measurement has double accuracy on positive side -0 ma 0-0 ma 0-0V Square root selection sqr = ON lin = OFF Following inputs are designed only for special applications and they can be skipped without notice. Pt00 W Pt00 W Pt000 W Pt000 W Ni00 W Ni00 W tc-b, tc-c, Chr-Co, Tc-d, tc-e, tc-g, tc-j, tc-k, tc-l tc-n, tc-r, tc-s, tc-t, Ir 0 factory settings 7

Alarm functions General description Panelmeter default relay card is REL. In comissioning you have to ensure the hardware setup before programming. You can find description of alarm card and its place on meter plate (def slot C). When basic selections are done in program stage, normal use by front panel keys is very simple. Alarm settings by front panel keys Relay indication lights A...A 0.0 * Alarm cards: REL = two relays with changeable contacts (grey connector colour). Grey connectors are designed for mains voltage 0 VAC, A and green connectors for VDC, 00 ma. Removing electronics from case: Press meter gently behind front plate and draw front frame upwards at upper edge. Checking of alarm value Pressing once shows setpoint of alarm one (A), correspondingly second pressing shows setpoint of alarm two (A) etc. Alarm indication light blinks in display informing that alarm level is displayed (if you do not touch keys during 8 seconds the display returns to normal state automatically). Preventing of entering alarms (secret code) If you have set secret code for alarms you must feed it before you can change alarms (see chapter settings of secret codes Page ). Changeing alarm value First pressing of key shows setpoint of alarm one (A), second pressing shows setpoint of alarm two etc. When indication light (A..A) blinks you can change alarm level by pressing or -key. You can change setpoint of relay in question with keys,,. Accept change by -key (if you do not touch keys during 8 seconds display returns to normal state with automatically and save with same made changes). Alarm mode, hysteresis and other settings are done in configuration state. Alarm card connections Input card I/O card Relay card REL Nc No Nc No Slot A Slot B Slot C A A Max. 0 VAC, A 7 8 9 Only one relay is available, Relay A (default) or A In menu: Line=A Line=A Optional cards in configuration menu are named as Slot C or B 8

Selection of alarm card and relay-function settings Meter has versatile alarm functions. In initial settings you can select first type of alarm card (default REL) into slot C. There are two relays but only one of relays is available. When initial settings have been made user can easily set alarm levels by front panel keys (see chapter alarm functions Page 8). You can prevent entering to alarm change stage by secret code (see chapter settings of secret codes. Alarm card must always be mounted to slot C (for totalizer). Main menu Inputs See page 0 Shifting in menu You shift in menu to next level (to right) in programming stage by -key. By -key you return to previous level or to main menu. Only one relay (line or ) can be used for alarm or batch function. Reset Hold Open contact Closed contact Slot b Off = no input functions Output line OFF Return to main menu Input Output Hold On = Stop counting Alarm level setting Slot C Setup Line ALArm Level 00.0 Select Slot C No alarms Default Card Card Off Serial ( sec.) Line A (Line = relay ) Unit remembers which card is in use and skips direct to selection of relay number (line ). You can select new card in setup-point by holding down or -keys seconds. Point OFFand then -key excludes the card from use. Front panel indication lights A..A correspond to relay (line) numbers... Serial = serial card, see chapter 'serial output RS-8/RS-'. Slot B tai Slot C = Card slot B or C Hysteresis selection Relay card Front panel Led's A-A AL = w level AL = gh level Alarm Reset: Manually from input line (slot b) or automatic Relay direction: No=normal open Nc=normal closed HyST.0 Type AL AL Reset User Auto Contact Nc No What starts the alarm (Line): Norm AL Scaled value without time unit tot AL Totalized value or flow rate / time unit LinE Norm AL tot AL Counter auto reset (op): ON Counter reset and new start without manual reset Off Manual reset with external button op Hold On Off On For Hold input (I/O-line in slot b): On = relay changes its stage when hold input is closing or batch item is reached Off = (default) relay changes its stage only when batch item is reached (alarm value) Off 9

Remote reset and hold function (totalizer) GENERAL DESCRIPTION In addition to automatic reset you can reset also by remote contact (optional). Contact is connected to add-card 000-MEM, which acts also as display memory. Display is stored for one week without power. Counting of display can be stopped by Hold function from I/O-line or installed to Slot B. PROGRAMMING In programming state you select Slot b. By the -key you enter Setup-menu in which you select card (I/Ocard). Then you move to next menu by -key, in which you select Line or. In next menu you select Reset or Hold of counter. After reset selection you choose function direction of reset contact (opening or closing). You can return to main menu by -key. In the Hold menu you can select opening or closing contact of hold input that stops counting. If you need to use relay together with hold function, see page 9. The reset and hold functions (inputs) can be closed by selecting OFF menu only. Return to main menu by -key Hold Reset Opening contact Closing contact OFF= no input functions OFF Return to main menu Select Slot B Input Output Slot b Setup Line ALArm Default ( sec.) Slot C Card Card Off Serial Select Card (default) Line L Input lines or Default settings: Hold () =line Reset () =line If you have selected Hold or Reset function earlier, you skip to this menu directly from Line menu. All inputs can be revented by selecting OFF menu and leave it by -key. Reset (Line): =closing contact resets display (default) =opening contact Hold (Line ): =closing contact stops counting (default) = opening contact I/O-card connection (Slot B) for totalizer function Input Slot A I/O-card (MEM) Line Line Com Slot B Reset =Line Hold =line Slot C 7 8 9 0

Minimum and maximum value memory Meter has min. and max. memory as standard. This function must be selected in programmimg stage, parameter PEAK=ON. You can glance values by -key. When you press the -key indication lights, above display, turns on in following order:. A alarm level. A alarm level A-A lits if alarm card(s) is (are) fitted.. A alarm level. A alarm level. M Minimum value memory. M Maximum value memory 7. Back to measuring stage Reset memeory You may reset memory when you press -key when display shows memory in question, either M or M. A A A A M M 0.0 * Memory can be viewed with -key Memory can be resetted with -key when indicator M or M lits. Setting of secret codes (Programming stage/ alarms) You set secret code by pressing six time keys (-) in wished order (lines goes forward in display). Setting must be repeated in same order before new setting is accepted. Example: Press one after another keys and once more. You may think the keys as numbers from left to right,, in order to help recording and remembering. e.g. Input code and once more. Example number value would be. In Main menu position SETCod press -key and move on to selection stage. ALCode = Secret code setting for alarms CFCode = Secret code setting for Programming Main menu Back Accept new code and exit SEtCod ALCode On - _ Type new secret code twice. (Accepts new value only after second input) CFCode OFF Back Select secret code mode: CFCodeprogramming ALCode for alarms Secret code: ON = enable OFF = disable (default)

Terminal connections Card slots Sensor supply VDC max. 0 ma (+) (-) Inputs Slot A I/O-card (MEM) Line Line Com Slot B Hold Reset Relays (REL) Nc No Nc No Slot C A A 7 8 9 Relays max. 0 VAC A (A is default for totalizer function) Card slot A only for input card. Slots B and C for optional cards. Power 90...0 VAC, Gray connector... VDC, VAC, green connector (no polarity) Colour codes: Gray 0 VAC Green VDC Input: Sensor supply VDC, max 0 ma + - 0...0 ma...0 ma + VDC Transmitter output -wire Com + - -wire -0 ma Short cut - + - -wire transmitter Current intput 0/..0 ma (active transmitter) Voltage input 0-0V Input card 0-MU + - 0...0 ma...0 ma 0-0V - + J 0/0V input Factory settings (-) 0/0 V input requires shortcut jumper J to position -, for other inputs shortcut -. Manufacturer: Nokeval Oy Yrittäjäkatu 700 NOKIA FINLAND www.nokeval.com Tel. +8 800 Fax. +8 0 mail@nokeval.com