Guidelines 85. Contents. 1. Scope of this guideline

Similar documents
Qualification of Washer/Disinfectors. Dr. Winfried Michels

Washer-Disinfectors - Effectiveness and Quality Assurance. T. Miorini Institute for Applied Hygiene / ÖGSV

ENDOSCOPE DECONTAMINATION : Where are we now!

minietd2 the small reprocessor with the big performance.

Innova new M2 and M3 series

CORRECT ENDOSCOPE REPROCESSING

Attendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

SOLUSCOPE SERIES 3 DESIGNED WITH THE FUTURE IN MIND FEATURES FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER

Institute of Decontamination Sciences Blackburn House, Redhouse Road, Seafield, Bathgate, West Lothian EH47 7AQ

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

From a Catalogue of measures to a Standard Operating Procedure Example: Reprocessing of flexible endoscopes

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

2015 Myco Industries, Inc Fax:

Cleanroom Technology. Complete solutions for pharmacies.

EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd

REUSABLE ENDOSCOPY INSTRUMENTS (thermo resistant)

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012

The Principles, The Process, and The Results:

Washer disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

I.F.U Re/Processing Reusable Medical Devices

Want to know more about the Notified Body? Everything you need to know to help you through the Notified Body process and on to accreditation.

Accurately With HSE COP PT 1 5

EUROWASHER. Instruments washer disinfector HSD. Medical device

Does your equipment meet your needs and the operational capacity stated by the manufacturer?

Cleaning and Sterilization for Instruments & Posts

9 Standards, Regulations and Authorities

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

ENDOSCOPE REPROCESSOR OER-Pro Operation Manual

INSTRUCTION MANUAL. Endo-Jet 2000 (EJ-2) PAULDRACH medical GmbH Porschestrasse Garbsen GERMANY

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Processing instructions for the Ligamys suture forceps

Cleaning & Sterilization

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

INSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE

ASSESSMENT REPORT ENDOZIME INSTRUSPONGE

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

O-PEP Hygiene-Beileger

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

This document is a preview generated by EVS

INTERNATIONAL STANDARD

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

1. Terms defined in the Construction Products Regulation (CPR)

Getinge WD15 Claro Washer-disinfector

Product Catalogue 2016

INTERNATIONAL STANDARD

Reusable Laryngoscope Blades and Handles

Flexible endoscope automated reprocessing system Safe and user friendly solutions for clinics

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Flexible endoscope automated reprocessing system

When you sterilize an instrument set, you know what the standards are.

Loss Prevention Standard

Low Temperature Sterilisation ISO 14937

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

Dental instrument Washer Disinfectors

Processing Instructions. Cleaning so easy.

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

ECB S Recommendation for Service, Repair and Modification Operations on ECB S Certified Secure Storage Units, Data Cabinets and Data Rooms

GK/GN0612. Guidance on Signalling Lockout Systems to Protect Railway. Undertaking Personnel. Railway Group Guidance for GK/RT0212.

Measurement of Safety Integrity of E/E/PES according to IEC61508

European Regulations of Medical Devices and In-vitro Diagnostic Medical Devices. The Notified Body Point of View

Cleaning and Sterilisation for Burs, accessories and filling material

1. What does the 3T Heater-Cooler Vacuum & Sealing Upgrade ( 3T V&S Upgrade ) consist of?

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you

Fujinon Medical Hygiene. Reprocessing of flexible endoscopes and endoscopic accessories.

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

BUSINESS PLAN CEN-CLC/TC 3 QUALITY MANAGEMENT AND CORRESPONDING GENERAL ASPECTS FOR MEDICAL DEVICES EXECUTIVE SUMMARY

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

EUROPEAN COMMITTEE FOR ELECTROTECHNICAL STANDARDIZATION (CENELEC) TECHNICAL COMMITTEE No. 62: ELECTRICALEQUIPMENT IN MEDICAL PRACTICE

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

Guidance Note No 19/1. CE Marking windows and doorsets

Pharmaceutical washing-systems

2. Push the drain connector into the disinfectant removal port until it clicks.

Elaborating of a Reprocessing Instruction According to ISO Klaus Roth

Scottish Health Technical Memorandum 2030 (Part 2 of 3) Design considerations. Washer-disinfectors

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Corporate. Laundry SOP. Document Control Summary

CLEANING STARTS WITH

An evaluation of washer-disinfectors (WD) and dishwashers (DW) effectiveness in terms of processing dental instruments

ESSENTIAL REQUIREMENTS CHECK LIST

Record of Amendments. Version Date Amendment Section/page affected

Record of Amendments. Version Date Amendment Section/page affected

OLYMPUS AMERICA, INC. ENDOSCOPE GROUP TWO CORPORATE CENTER DRIVE MELVILLE, NEW YORK TEL (631) March 3, 2003

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

Technical Bulletin CE marking: from 1st July 2013

Industrial, Medical and cgmp-conform Cleaning Equipment

FINAL DRAFT INTERNATIONAL STANDARD

Dr. Weigert - New Standards in Cleaning and Disinfection of Medical Devices

A new wave in instrument washing and disinfection Introducing the HYDRIM G4 WD series

Quality Management Systems - Audit Requirements for Aviation, Space, and Defence Organizations

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

X99 Series. Dental Handpiece. Instruction For Use

Transcription:

Guidelines 85 ESGE/ESGENA guideline for process validation and routine testing for reprocessing endoscopes in washer disinfectors, according to the European Standard pren ISO 15883 parts 1, 4 and 5 Authors Institutions U. Beilenhoff 1, C. S. Neumann 2, H. Biering 3, R. Blum 4, V. Schmidt 5, J. F. Rey 6 and the ESGE Guidelines Committee Institutions are listed at the end of article. Bibliography DOI 10.1055/s 2006 945191 Endoscopy 2007; 39; 85±94 Georg Thieme Verlag KG Stuttgart New York ISSN 0013 726X Contents 1. Scope of this guideline 2. Quality management: the roles of validation and routine testing 3. Responsibilities and qualifications 4. Validation 4.1. Prerequisites 4.2. Installation qualification (IQ) 4.3. Operational qualification (OQ) 4.4. Performance qualification (PQ) 5. Routine testing 6. Frequency 6.1. Frequency of validation and revalidation 6.2. Frequency of routine testing 7. References 8. Appendices Appendix 1: Glossary Appendix 2.: Example of a checklist of prerequisites for installation of a washer disinfector Appendix 3.: Example of a checklist for installation qualification Appendix 4.: Example of a checklist for operational qualification Appendix 5.: Example of a checklist for performance qualification Appendix 6.: Routine testing: checklist 1. Scope of this guideline Validation is an important quality assurance tool in hygiene and infection control, whether endos copy procedures are performed in hospitals, in private clinics, or in doctors offices. Up till now, the clinical service provider (see Appendix 1: Glossary) has had to rely on the correct functio ning of automated washer disinfectors according to the manufacturer s specifications. The current tools for regular quality control are routine main tenance and microbiological surveillance. Validation procedures have long been common practice in the monitoring of sterilization devi ces, for example in central sterilization units. The implementation of validation of reprocessing procedures for flexible endoscopes will be an im portant step for systematic quality assurance and patient safety. This guideline, from the European Society of Gas trointestinal Endoscopy (ESGE) and the European Society of Gastroenterology and Endoscopy Nur ses and Associates (ESGENA), is based on the Eu ropean standard, pren ISO 15883, which descri bes in detail the design and function require ments for washer disinfectors. This ESGE/ESGE NA guideline addresses the need to validate the entire reprocessing cycle for flexible endoscopes and their accessories, because such validation: " ensures the transparency of reprocessing pro cedures " supports the early detection of weaknesses and defects in washer disinfectors " is based on dedicated and proven test me thods for benchmarking

86 Guidelines QM of WD manufacturer Quality management of clinical service provider Figure 1 Quality Management for reprocessing of flexible endoscopes. Type Test Detailed analysis of each process parameter and of the complete reprocessing cycle Test, showing conformity of the WD with the pren ISO 15883. Validation Evaluation of reprocessing performance under conditions at the point of use Check of pre-requisites Installation qualification Operational qualification Performance qualification Routine Test Evaluation of outcome quality by technical and microbiological tests Testing of: Endoscopes WD Water " has the potential to reduce the amount of routine testing This guideline is an expert opinion and provides practical infor mation about and guidance through the validation of the entire procedure of reprocessing with washer disinfectors. Example checklists are provided to support the implementation of valida tion at each individual endoscopy unit. Aims of this guideline These are: " To support individual endoscopy departments and clinical service providers in establishing local standards and proto cols for validation processes for endoscope reprocessing with washer disinfectors " To support national societies and official bodies in developing national recommendations for the validation of procedures for reprocessing flexible endoscopes Target groups This guideline provides practical guidance through the validati on process for the following groups: " Clinical service providers, as they have the responsibility to meet structural and organizational requirements and to pro vide educated staff, for the safe use of washer disinfectors " Endoscopists, endoscopy nurses, and other users of washer disinfectors, who use flexible endoscopes and who are responsible for the safe reprocessing of endoscopy equipment " Hospital hygienists, microbiological personnel, microbiolo gists, and authorized agencies, who perform regular micro biological quality control in endoscopy units " Manufacturers, suppliers, and authorized third parties who sell, install, and maintain flexible endoscopes and washer disinfectors for gastrointestinal endoscopy " Institutions, companies, and other qualified agencies that are authorized to perform validation of washer disinfectors 2. Quality management: the roles of validation and routine testing The European standard pren ISO 15 883 consists of five parts, of which three are relevant to endoscopy: " Part 1 states the general requirements and definitions for all washer disinfectors. " Part 4 defines the special requirements for the design of washer disinfectors and for reprocessing of heat sensitive instruments such as thermolabile, flexible endoscopes. In addition, pren ISO 15 883±4 requires a check on whether the correct reprocessing results are obtained with all endoscope types to be reprocessed under the particular circumstances obtaining at the service provider s location (water quality, power supply etc.). This process is called validation. " Part 5 provides test soils and methods for demonstrating the cleaning efficacy of washer disinfectors. Quality assurance systems for washer disinfectors comprise three parts (see l " Figure 1), type testing, validation, and routine testing. 1. Type testing according to pren ISO 15883, is the responsibility of the manufacturer and checks that the washer disinfector complies with the pren ISO 15883 standard. During type testing, each individual step of the reprocessing cycle is separately ana lyzed (e. g. cleaning efficacy, disinfection efficacy, water quality, chemicals), followed by evaluation of the reprocessing cycle as a whole. In addition, type testing provides reference data for furt her validation and use of the washer disinfectors. 2. Validation is the responsibility of the clinical service provider. It demonstrates that the entire reprocessing procedure gives re producible results at the point of use as required. Single param eters can be defined as indicators. The validation process for washer disinfectors includes the following steps: " Installation qualification (IQ), to check that the equipment is received as specified, that it is correctly installed, and that the particular location is suitable for the use of the washer disin fector " Operational qualification (OQ), to check that the washer dis infector will operate as specified in the endoscopy unit con cerned " Performance qualification (PQ), to check that the washer dis infector consistently performs according to the specification for routine use Validation must be repeated (revalidation): " on a regular basis (according to national requirements), " after each major change of the reprocessing cycle, or " after major repair. This is in order to document that the reprocessing process still achieves the same required, reproducible results. 3. Routine testing is the responsibility of the clinical service pro vider. Based on the validation results, routine tests are establis hed in order to prove that the washer disinfector works within the defined limits for dedicated parameters and to prove the outcome quality of the complete reprocessing cycle. Routine tes ting may include tests of endoscopes, washer disinfectors, and the water used in the particular department. An appropriate sampling plan has to be established for each type of washer dis infector. This guideline focuses on the validation process (including in stallation, operational, and performance qualification) and on the routine testing.

Guidelines 87 Validation Responsibility Option for Execution Qualification Table 1 Responsibilities and Qualification in Quality mana gement of validation Prerequisites Clinical Service Provider Manufacturer Authorised Supplier Authorised third party IQ OQ Clinical Service Provider Clinical Service Provider PQ Clinical Service Provider Manufacturer Authorised Supplier Authorised third party, Endoscopy staff Microbiological institutes Microbiological staff Hygienists Infection control nurses Routine tests Clinical Service Provider Expertise in regulatory issues technical and elect rical issues of WD, chemi cals, flexible endoscopes and special equipment Microbiological expertise Technical understanding of the WD 3. Responsibilities and qualifications It is the responsibility of the clinical service provider to ensure that validation is carried out. Validation must be done at the lo cation where the washer disinfector is being used. A qualified company/person may carry out validation on behalf of the clini cal service provider. It is strongly recommended that the compa ny or persons performing such validation have expert knowl edge in all relevant areas such as microbiology, hygiene and in fection control, technical and electrical issues relating to was her disinfectors, chemicals, flexible endoscopes, and regulatory issues. The clinical service provider must document all the relevant va lidation data for the washer disinfector, and the use of standard checklists is recommended. This guideline provides examples of checklists [1] which can be adapted to local structures and the requirements of particular clinical settings (see section 8, Ap pendices 2 ± 6.) Installation qualification is usually performed by the manufactu rer, the supplier, or authorized third parties. Operational qualification is the responsibility of the clinical ser vice provider. Specialized knowledge will be required about: technical and electrical issues relating to washer disinfectors; chemicals; flexible endoscopes; regulatory issues; and special equipment. Therefore it is recommended that authorized and specially trained persons perform this validation. The manu facturer of the washer disinfectors must provide instructions on how to test the various process parameters and functions of each washer disinfector. The manufacturer may also need to supply appropriate specialized test equipment. Performance qualification is the responsibility of the clinical ser vice provider. Only persons or organizations with appropriate microbiological expertise should carry out these tests. Additio nally, such persons or organizations should have a thorough un derstanding of the structure and function of the tested washer disinfectors and endoscopes. Routine testing is the responsibility of the clinical service provi der. The tests may cover technical and microbiological parame ters, and should therefore be performed by appropriate trained persons. Collection, culturing, and the interpretation of test re sults should be done in close cooperation with endoscopy staff, the hospital hygienist, appropriate microbiology personnel, and the microbiologist, in line with national requirements. An example of the procedures and expertise required for valida tion and routine testing has been published recently [2]; l " Ta ble 1 shows these, linked with the appropriate organizations and personnel needed to carry out the procedures. 4. Validation 4.1. Prerequisites The endoscopy department or unit must fulfil technical and or ganizational prerequisites. A purpose designed room for clea ning and disinfection that is separate from procedure rooms is recommended, to minimize patient and staff exposure to: " chemicals used in cleaning and disinfection procedures (e. g. because of toxic/allergic reactions, glutaraldehyde vapour) " the risk of infection and contamination with potentially in fectious material, blood and other body fluids. The manufacturer must provide information about the structure and function of the washer disinfector. The validation can be performed when the washer disinfector is installed according to the manufacturer s instructions and local safety regulations, and when all components and utilities are available. The checklist in Appendix 2 is an example of what should be considered. It is based on the recommendations of the ESGE Gui delines Committee and relevant European guidelines [3, 4]. 4.2. Installation qualification (IQ) Installation qualification is the process of obtaining and docu menting evidence that the washer disinfector has been supplied and installed in accordance with its specifications. Checks need to be carried out that all ordered items have been received and that the location of the washer disinfector correctly fulfils speci fications (e. g. with regard to water quality, power supply, etc.). An example of a checklist is shown in Appendix 3. 4.3. Operational qualification (OQ) Operational qualification is the process of obtaining and docu menting evidence that the installed washer disinfector operates within predetermined limits when used in accordance with its operational procedures. For example, checks are needed to show whether: " the leak test and the flow control function in accordance within their specifications,

88 Guidelines " the temperature profile is in line with specifications, and " the dosage pumps for the chemicals deliver the right quanti ties. A standardized checklist is available in Appendix 4. 4.4. Performance qualification (PQ) Performance qualification is the process of obtaining and docu menting evidence that the washer disinfector, as installed and operated in accordance with operational procedures, consistent ly performs in accordance with predetermined criteria and the reby yields reprocessed instruments according to the specificati ons. Performance qualification focuses on the testing of the washer disinfector in operational conditions. The efficacy of the cleaning and disinfection steps should be evaluated as a combined test procedure. The pren ISO 15 883 ± 5 standard offers a variety of test soils and methods for demonstrating cleaning efficacy, but there is cur rently no consensus in the relevant working group of the CEN (ComitØ EuropØen de Normalisation/European Committee for Standardization) regarding preferred test soils and methods. Therefore, the present guideline only recommends that they should be carried out on endoscopes that are routinely used in clinical practice and should include representative samples of all types of endoscopes used and reprocessed in the particular department. The endoscopes employed in the performance qualification pro cedure should be used in clinical practice and should be repro cessed following the everyday standardized reprocessing proto col, including pre cleaning by brushing manually and cleaning and disinfection in the washer disinfector. This will ensure that potential negative side effects of incompatible chemicals are identified. National guidelines and laws on validation and hygiene in en doscopy vary from country to country [5, 6]. Test procedures for performance qualification have to be modified according to na tional regulations. This guideline includes suggestions for tes ting important process parameters. Test condition procedures for evaluating the results and to achieving limits are available in Appendix 5. 5. Routine testing Routine testing ensures that the required performance standard is delivered consistently at all times. Based on the individual risk assessment and the results of the validation of each individual machine, the extent of the routine testing has to be defined, based on national recommendations and pren 15 883/4 Annex C. These routine tests cover technical and microbiological parameters. Routine checks of technical parameters (such as leakage testing and channel non obstruction testing, and of temperature, water quality, etc.) can reduce the required number of microbiological tests on endoscopes, as the technical tests demonstrate that the washer disinfector is working within its specifications. In additi on paper print outs document that the particular reprocessing cycle has been completed within the required process parame ters. Daily check ups of single machine parameters document that the washer disinfector operates within its specifications. These daily check ups may be defined by the manufacturer or the service provider. For performance of microbiological tests on endoscopes, it is re commended that the ESGE±ESGENA guideline on microbiologi cal surveillance testing in endoscopy is followed [7]. If any routine test result breaches the specification (because it is out of the predetermined range of the technical parameters or because of contamination), it is the responsibility of the clinical service provider to take the suspect device out of service (e. g. washer disinfector, endoscope), until corrective actions have been taken and satisfactory results have been achieved. Examples of possible test options are given in Appendix 6. 6. Frequency 6.1. Frequency of validation and revalidation A complete validation is necessary before routine use. This first validation is a baseline assessment of the adequacy of effective ness (pren ISO 15883 4). A revalidation is necessary after any major repair, change, or both of the reprocessing cycle (e. g. in temperatures, process che micals). Regular maintenance of washer disinfectors is part of quality management and is a prerequisite for their safe use. It ensures the early detection of possible weaknesses and defects in was her disinfectors. 6.2. Frequency of routine testing In order to confirm the correct functioning of the washer disin fectors, routine testing on a regular basis according to national requirements is recommended. The frequency of routine micro biological tests can be reduced if the machine consistently shows reliable technical results on routine tests. It is the respon sibility of the clinical service provider to decide on the intervals between microbiological tests. The frequency of routine microbiological testing varies across Europe [7]. This guideline therefore will have to be modified lo cally to comply with the relevant national regulations. As a point of reference, the ESGE±ESGENA Guideline Committee recom mends routine testing every 3 months at least. Institutions 1 ESGENA Treasurer, ESGE Guidelines Committee chairman, Ulm, Germany 2 ESGENA President, Clinical Investigation Unit, City Hospital NHS Trust, Bir mingham, UK 3 R,D&E Health Care EMEA, Ecolab GmbH&Co OHG, Düsseldorf, Germany 4 BU Endoscopy Reprocessing Systems, Olympus Medical Systems Europa Gmbh, Hamburg, Germany 5 Leitung Fachgebiet Mikrobiologie und Hygiene, Chemische Fabrik Dr. Wei gert GmbH & Co. KG, Hamburg, Germany 6 ESGE Guidelines Commitee chairman, Institute A. Tzanck, Saint Laurent du Var, France 7. References 1 DGVS. Leitlinie von DGKH, DGSV und AKI für die Validierung und Rou tineüberwachung machineller Reinigungs und Desinfektionsprozes se für thermostabile Medizinprodukte und zu Grundsätzen der Gerä teauswahl. Zentralsterilisation 2005; 13 Suppl 1: 1± 33 2 DGSV (Deutsche Gesellschaft für Sterilgutversorgung [German Society for Sterile Supply]). Qualification requirements for persons entrusted with validation. Zentralsterilisation 2005; 13: 375 ± 376 3 ESGE ESGENA Guideline Committee. Guidelines on cleaning and disin fection in gastrointestinal endoscopy ± update 1999. Endoscopy 2000; 32: 77± 83

Guidelines 89 4 ESGE ESGENA Working Group. ESGE±ESGENA checklist for purchase of washer disinfectors for flexible endoscopes. Endoscopy 2000; 32: 914± 919 5 Rey JF, Kruse A. Cleaning and disinfection in Europe according to the Endoscopic Societies guidelines. Endoscopy 2003; 35: 878 ± 881 6 Leiss O, Beilenhoff U, Bader L et al. Reprocessing of flexible endoscopes and endoscopic accessories ± an international comparison of guideli nes. Z Gastroenterol 2002; 40: 531 ± 542 7 ESGE/ESGENA guideline for quality assurance in reprocessing: micro biological surveillance testing in endoscopy. Endoscopy 2007; in press 8. Appendices The tables and checklists in Appendices 2±6 are based on the German Guideline for alidation of automated reprocessing pro cesses or thermostable medical devices [6]. Appendix 1: Glossary Clinical service provider: An organization, person, or persons le gally responsible for the provision of a clinical service. Could be an institution (such as the health service), hospital or depart ment, or a doctor working in his own premises. User: Person or department using equipment; organization(s) or persons within those organization(s) who operate and/or use the equipment Process chemicals: All chemicals used during the reprocessing procedures, including detergents, disinfectants, alcohol, etc.

90 Guidelines Appendix 2: Example of a checklist to evaluate the prerequisites for installation of a washer disinfector Part 1 Environmental and structural prerequisites for the clinical service provider Requirement Available Countermeasure, Comments Purpose designed reprocessing room, separate from procedure rooms Separation of contaminated and clean working areas Information about water quality (e. g. hardness and microbiological status) Trap (U bend) in drainpipe Ventilation of reprocessing room Room temperature conditions defined Isolating valve and dirt arrester for cold water Isolating valve and dirt arrester for warm water Isolating valve for demineralised water Mains switch for electrical power supply Device for hand disinfection Storage for process chemicals, safe supply Health and safety requirements Part 2 Organizational prerequisites for the clinical service provider Requirement Available Countermeasure, Comments Reprocessing instructions for each medical device Risk analysis for reusable medical devices (with respect to hygiene) Medical device file and manual for WD, including description of the entire reprocessing procedure Maintenance and service schedule for washer disinfectors Safety data sheets for all process chemicals Definition of test load for performance qualification Definition of person responsible for performance qualification Certification of reprocessing staff (training courses, competency assessment) Hygiene plan and reprocessing protocols Compatibility of WD, endoscopes and process chemicals Appendix 3: Example of checklist for installation qualification General Information about the washer disinfector Installation location Person responsible for validation Further responsible persons Date of validation Type of device Manufacturer Serial number Year of production Process chemicals Applicable (Yes/No) No. Product name Manufacturer Function 1 Part 2 Type/Title Documentation Delivered Docu To be Part 1 Delivery contens Products ordered Article number Amount received products Damage (Yes/No) Installation plan Circuit diagrams Instruction manual Other manuals (i. e. Maintenance) Safety data sheets of che micals Reports and certificates Declaration of conformity MDD 93/ 42 (Yes/No) ment no. filed at:

Guidelines 91 Type of installation and installation task Department/Company Date of Installation Part 3 Responsible Depart ments/companies. All internal Electrical power supply departments and external Water supply companiesin charge of prepa Drainage ration of the installation site Air ventilation and maintenance shall be listed Appendix 4: Example of a checklist for operational qualification General information about the washer disinfector Device Location of installation Person responsible for validation Date of validation Part 1 Basic functions Requirement Applicable OK Not OK Comments, Coun Check all water supply pipes in leakage concerned Check drainage pipes for buckling Check power supply; connectors available Check all door seals for leakage Check all sieves and filters (outside washer disinfector), sterile filters for availabi lity and leakage Check all sieves and filters (inside washer disinfector) for availability and dirt Check spray arm for availability, check rpm* Check liquid level sensor Check function of scope identification Check functionality of documentation (printer or network connection) Check all adapters (position and function) Check leak test adapters (position and function) and endoscope connection Check external ventilation (if required) Check door lock of washer disinfector, function, seals Check whether START of process is blocked if washer disinfector door is still open Check filter efficacy (chemicals, vapour etc) termeasure Part 2 Operational functions Water supply: Applicable (Yes/No) Name/No. of process Water Supply Process cycle Specified volume range*, L Measured volume, L Comment Pre cleaning Cleaning Rinsing Disinfection Rinse 1 Rinse 2 Rinse 3 * As specified in type testing of each individual washer disinfector

92 Guidelines Temperature: Applicable (Yes/No) Name/No. of process: Temperature Process cycle Specified temperature range*, 8C Pre cleaning Cleaning Rinsing Disinfection Rinse 1 Rinse 2 Rinse 3 Drying * As specified in type testing for each individual washer disinfector Measured temperature, 8C Comment Dosage process chemicals: Applicable (Yes/No) Dosage Product no./name of Specified range of vol Measured volume, ml Comment product ume*, ml, tolerance 1 2 3 * As specified in type testing for each individual washer disinfector Part 3: Machine and alarm functions Requirement Applicable Ok Not Ok Comments, Countermeasure Alarm function: Leak test NOK (simulation leak) Alarm function: channel non obstruction test Alarm function: Insufficient dosage Alarm function: No process chemicals Alarm function: Water supply Alarm function: Temperature Documentation (process print out) Cycle completion 1 ( pass function); Cycle completion 1 (fail function); Documentation of temperature profile Cycle completion 2 ( pass function); Cycle completion 2 (fail function); Documentation of temperature profile Cycle completion 3 ( pass function); Cycle completion 3 (fail function); Documentation of temperature profile Name Prog. 1 Name Prog. 2 Name Prog. 3

Guidelines 93 Appendix 5: Example of a checklist for performance qualification General information Location of installation Person responsible for validation Date of validation Persons collecting the test samples Institution and persons performing culturing Type/Article of tested endoscope Serial number of tested endoscope Date of last reprocessing cycle Washer disinfector used for last reprocessing cycle (arti cle, serial number) Type/Article of tested washer disinfector Part 1: Microbiological tests Sample number Volume of sterile saline used Results ± Specification of micro organisms found ± Number of cfu* 1. Test of Endoscope 1.1. Endoscope channels ± Suction/instrument channel ± Air water channel ± Elevator channel ± Separate flushing channels 1.2. Swabs from endoscopes surfaces ± Control part ± Distal end ± Channel openings ± Elevator on duodenoscopes 2. Test of washer disinfector ± Sample from last rinsing water from washer disinfector * cfu, colony forming units Appendix 6: Routine testing checklist General information Installation place Person responsible for validation Date of validation Part 1: Technical tests (examples of possible test parameters): Name/No. of washer disinfector and process: Temperature Process cycle Specified temperature range*, 8C Cleaning Disinfection Drying * As specified in type testing of each individual washer disinfector Measured temperature, 8C Comment

94 Guidelines Part 2 Machine and alarm functions (examples of possible alarm functions): Requirement Applicable Ok Not Ok Comments, Countermeasure Alarm function: Leak Test NOK (simulation leak) Alarm function: channel non obstruction test Alarm function: Insufficient dosage Alarm function: Water supply Documentation (process print out) Part 3 Microbiological tests Persons collecting the test samples Institute and persons performing culturing Type/Article of tested endoscope Serial number of tested endoscope Date of last reprocessing cycle Washer disinfector used for last reproces sing cycle (article, serial number) Type/Article of tested washer disinfector Serial number of tested washer disinfector 1. Test of Endoscope 1.1. Endoscope channels ± Suction/instrument channel ± Air/water channel ± Elevator channel ± Separate flushing channels 1.2. Swabs from endoscopes surfaces ± Control part ± Distal end ± Channel openings ± Elevator on duodenoscopes 1.4. Water bottle ± Water sample from used bottle 2. Test of washer disinfector Sample of final rinsing water from washer disinfector * cfu, colony forming units Sample number Volume of sterile saline used Results ± Specification of germs founded ± Number of cfu*