CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

Similar documents
LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Comprehensive Short-Term Radon Survey Report

Measurement Devices. Topic 5 - Audio 56

C-NRPP Quality Assurance Guidance for Radon Test Devices

ALL RADON TESTS WERE SIGNIFICANLY BELOW

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR

Quality Assurance Plan for Conducting Radon Measurements

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Bethel School District Radon Testing Plan

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories


Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

MCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation

RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon

Woodlin Elementary School Date of Report March 14, 2018

RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817

EagleRidge High School. Radon Testing Plan

Radon Detection Specialists, Inc.

RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

Radon Detection Specialists, Inc.

CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN

Certificate of Completion

Radon Detection Specialists, Inc.

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT

Radon Detection Specialists, Inc.

Policy Manual. April 21,2015. National Radon Proficiency Program 2015

CHAPTER 240. RADON CERTIFICATION

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings

Certificate of Completion

CHARCOAL CANISTER RADON SURVEY QUALITY ASSURANCE PROJECT PLAN

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Love the Lungs You re With

Certificate of Completion

RULES AND REGULATIONS FOR RADON CONTROL

RADON SCREENING SURVEY FOLLOW-UP SPRINGBROOK HIGH SCHOOL

Radon Detection Specialists, Inc. Love the Lungs You re With

2.3 Definitions, General Provisions, and Radon Standards

Illinois School District & Daycares

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

Illinois School District & Daycares

A new passive integrating detector for measurement of individual radon exposure at working places.

In Schools. Revised Edition. oepa. Aa Bb Cc Dd Ee Radon Measurement. Air And Radiation (6604J)

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

Property of Aztec Home Services LLC

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

Radon Reference Facility at Bowser-Morner, Inc. AMUG Meeting Las Vegas May 4, 2010 Phillip H. Jenkins, PhD, CHP

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm

Testing for Elevated Radon in Oregon Schools Protocol and Plan

adsw worth Center, New York State Department of Health, Albany, NY 12201

AIR POLLUTION Uncertainty Exists in Radon Measurements

WORKING. TOGETHER to PREVENT LUNG CANCER. A Guide to help you with testing your Child Care Centre for Radon

Radon Testing Results. City Hall

Table of Contents EPA (Radon).1 CPSC (Safety) 43 Business.48

Pennsylvania Citizen s Guide to Radon. Test your home for radon it is easy and inexpensive.

RADON LAZERWEB SERVICES

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Guide for Radon Measurements in Residential Dwellings (Homes)

Home Buyer s and Seller s Guide to Radon

Home Buyer s and Seller s Guide to Radon

Radon Measurement Report

Model Carbon Monoxide (CO) Alarm Response Policy

Multnomah Education Service District

EPA estimates that radon causes thousands of lung cancer deaths in the U.S. each year.

Dealing With RADON in Real Estate Transactions

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

Home Buyer s and Seller s Guide to Radon

AVERAGE RADON CONCENTRATION: Test has met minimum EPA sampling duration.

Property Inspected: 623 Pine St, Macon, GA 31201

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

U.S. Environmental Protection Agency, Radon Division Washington, DC

Property Inspected: 1228 Radcliffe Ave, Kingsport, TN 37664

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

Testing for Elevated Radon in Oregon Schools

radon Keeping your home safe from radon

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Environmental Resources Group, LLC (ERG) has completed the Radon Testing for the referenced property in Ann Arbor, Michigan.

Dealing With RADON in Real Estate Transactions

Radon Test Results, Prentis II Apartments, West 10 Mile Road, Oak Park, Michigan (ASTI Project No )

Software Failure Mode and Effects Analysis of Concept Phase for Radiation Monitoring System Digital Replacement

A STATE OF THE ART INTEGRATED CHEMICAL BIOLOGICAL & RADIATION WATER MONITORING SYSTEM

AVERAGE RADON CONCENTRATION:

Radiation Monitoring Equipment

Portable Survey Instruments NISP-RP-01

Testing for Elevated Radon in Oregon Schools

Procedures for Preparing and Receiving PUF Canisters and Filters

HEALTH AND SAFETY MANUAL

Transcription:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting Method Number: ELAP method number 7036 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: General LLD: < 1 pci/l Page 1 of 6

RADON IN AIR Page 2 of 6 NYSDOH Environmental Laboratory Approval Program Radon Checklist 1. Are both of the following EPA publications available at the lab: a. Protocols for Radon and Radon Decay Product Measurements in Homes? (EPA 402-R92-003) N002 b. Indoor Radon and Radon Decay Product Measurement Device Protocols? (EPA 402-R92-004) N003 2. Does the facility monitor Radon levels in air for a minimum of 48 continuous hours, process the collective data and interpret the result N004 for the client (rather than merely distributing devices)? 3. Is a written standard operating procedure (SOP) available? (Duplication of the protocols will not suffice.) N005 a. Does the analyst follow the manufacturer s instructions, the US EPA protocols and the lab s SOP? N072 4. Is a written quality assurance project plan (QAPP) appropriate to each device available? N006 5. Does the data collection log include: a. Date and time of deployment? N007 b. Date and time of removal? N008 c. Condition of the devices? N009 d. Attainment of closed building conditions? N010 e. Exact location of device (i.e., building, room and sampling position) within the property being monitored? N011 f. Serial number, model number, and manufacturer of the detector? N012 g. Unique identifier of client and client s address (if different from testing location)? N013 h. Condition of crawl space vents? N014 6. Are monitoring devices deployed and retrieved by trained employees of the radon laboratory? N015 7. When monitoring devices are set out and picked up by different persons, is this noted in the record? N016 8. Is a qualifying statement used if the lab does not control the monitoring process (i.e., placed and/or retrieved by persons other N017 than trained lab personnel)?

9. Are all devices deployed for 48 continuous hours if the measurement is used for remedial action or to determine the need for N018 further measurements? 10. Is the technical director of the laboratory aware of the device s Lower Limit of Detection (LLD), and has the background level been N019 determined? EQUIPMENT 1. Are charcoal containers sealed with a protective cover? N023 2. Is an instruction sheet provided to the client? N024 3. Is a shipping container provided to the client for returning the charcoal container(s)? N025 4. Is a data collection log available? N026 5. Is counting done with a sodium iodide gamma scintillation detector? N027 6. Is the detector linked to either a multi-channel gamma spectrometer or a single-channel analyzer with the window set to N028 include the appropriate gamma energy window? 7. Is the detector system and geometry identical to that used to derive the calibration factors? N029 8. Does analysis start at least 3 hours after sampling? N030 9. If no desiccant is used, are charcoal containers weighed before and after analysis to account for water adsorption? N031 a. Is a correction factor applied to results for water adsorption? N031A 10. Is the shelf life of the desiccant documented? N032 QUALITY CONTROL Routine Instrument Check Source 1. Is an instrument check source (ICS) used to calibrate the scintillation detector daily or with use? N034 2. Is there a record of daily or with use calibration using an ICS? N035 3. Does the ICS yield a good count rate (e.g.,1000-10,000 cpm) in N036 Page 3 of 6

a short time? 4. Is the ICS of similar geometry and type to the samples to be counted? N037 5. Are in-house derived control limits determined? N039 Field Control Detectors 1. Are field control detectors kept in a low radon (less than 0.2 pci/l) area? N042 (field control detectors = field blanks) 2. Are field control detectors deployed at at the rate of 5% of deployed detectors each month with a maximum of 25 per month? N043 3. Are field blanks labeled as real samples and returned to the supplier for analysis? N044 4. Are the results of field blanks tabulated? N045 5. Are acceptance limits indicated on the tabulation of field blanks? N046 6. Is the tabulation of field blanks up to date? N047 7. If the acceptance limits are exceeded, is the source of the problem determined and corrected? N048 Duplicate Collocated Detectors 1. Are duplicate detectors installed in homes at the rate of 10% of deployed detectors each month with a maximum of 50 per month? N050 2. Are the duplicates systematically distributed throughout the workload? N051 3. Are the duplicates handled identically to the samples? N052 4. Are the duplicates not identified as such to the analyzing laboratory (i.e., submitted blindly)? N053 5. Is the precision of the duplicate data from radon levels measured at 4 pci/l or above within 10% Relative Standard Deviation (RSD: for a long-term series of duplicate measurements), or 14% Relative Percent Difference (RPD: for a single pair of duplicates)? 6. Are the data from duplicates available (e.g., control charts)? N054 N055 7. Are the acceptance limits for duplicates determined? N056 Spiked Samples Page 4 of 6

1. Are Spiked samples with known radon exposures submitted at the rate of 3 per 100 measurements, with a minimum of 3 per year and a N060 maximum of 6 per month? 2. Are spiked samples labeled as routine samples? N061 3. Are the results of spiked samples kept as part of the record (e.g., control charts)? 4. If the acceptance limits are exceeded, is the source of the problem determined? SYSTEM CALIBRATION 1. Has either the manufacturer or the lab calibrated the complete system (detectors and readers) in a Radon Chamber yearly? a. Does the lab maintain the charcoal suitability study from the manufacturer? b. Is the exposure period sufficient to allow the detector to achieve equilibrium with the chamber atmosphere? 3. If the manufacturer is performing the calibration, does the lab utilize the correct calibration coefficient? RECORD KEEPING N062 N065 N067 N068 N069 N070 1. Are the following record(s) kept for 5 years by the measurement organization: a. A copy of the final report including measurement results and the statement outlining any recommendations concerning N237 retesting or mitigation provided to the building occupant or agent? b. The address of the building monitored including zip code? N238 c. The exact locations of all deployed measurement devices? (Examples: room sketches, detailed written description) N239 d. Exact start and stop dates and times of the measurement period required for analysis? N240 e. A description of the device used including the device identification number and serial number, if applicable? N241 f. A description of the condition of any permanent vents? N242 g. The name of the service organization used for calibrations and the certificates of calibration? N243 Page 5 of 6

h. The name of the individual who conducted the test along with their associated training records? N244 i. A description of any variations from or uncertainties about standard measurement procedures, closed building conditions, or other factors that may affect the measurement N245 result? j. A description of any non-interference controls and copies of signed non-interference agreements? N246 k. A record of any quality control measurements associated with the test? N247 l. The written authorization from the client enabling the lab to report results to a third party (if applicable)? N254 REPORTING 1. Does the lab report the result with an uncertainty or error factor, one is provided by the manufacturer? N249 2. Does the report contain the advisory of 10 NYCRR 16.130 for properties tested within New York State having measured radon gas N257 levels >20 pci/l or 0.1 working level? 3. For labs within NYS, does the laboratory report all of its radon monitoring data to the State according to 10 NYCRR 16.130? N258 4. Are field duplicate readings, if available, reported in an acceptable manner? (See EPA 402R92-003). N259 When any radon screening or long term testing result exceeds 20 pci/l or 0.1 working level as defined in section 16.2(a)(145), the customer, if a resident of New York State, is advised to contact the New York State Department of Health, Bureau of Environmental Radiation Protection, for further technical advice and assistance. New York State Radon Office Phone (518) 402-7556 Toll Free (800) 458-1158 Website: http://www.health.state.ny.us/environmental/radiological/radon NOTES: The calibration factor (CF) of monitoring devices decreases with increasing humidty and exposure time (A.C. George 1984). Results from A.C. George study: A 3-day exposure (with T = 23 C and relative humidity = 50%) resulted in a CF of 0.042 ±.003 l/min. The CF is the effective sampling rate rate in l/min. The lower limit of detection (LLD) for a 3-day exposure when counted 3 and 72 hour post exposure was 0.2 and 0.3 pci/l. Page 6 of 6