inorax Outdoor Enclosures

Similar documents
Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

LANDE SECURITY CABINETS and FIELD ENCLOSURES

ENCLOSURE COOLING. Glossary

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Eldon Product Overview

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

AIR HANDLING UNITS. Revision AG 16-07

Double Skin Casing Air Handling Units

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

Oil Mist Eliminators PMR Series

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

VA G 052 S

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

SITESTAR CABINET DESCRIPTION

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Package Hygienic Air Handling Units. PHK Series

Fibre Solutions for Harsh Environments

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Thermal Management INDEX. Management. Thermal TM-1

CGAM air-cooled scroll chiller. Highly efficient, yet extremely quiet

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

19 Cabinets. Eurolan. 19" Floor Standing Cabinets. Racknet Floor Standing Cabinets. Racklan Floor Standing Cabinets. Rackserv Floor Standing Cabinets

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

Outdoor Racks. - Especially designed for, telecomunications, - Double thermally installed. Product Datasheet CHARACTERISTICS

Cooling unit Mechanical control

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Custom Duct Heaters. Special Applications

Guardian/GuardianX Series NEMA 4 or 4X Rated Air Conditioners. Air Conditioners:

EC3-X33 Stand-alone Superheat Controller Technical Data

PR / MP I Laboratory / Medicine

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

enclosuresystems.co.uk Enclosure Systems 455 Series IP55 Outdoor Wall Mounting Cabinets by Canford Cabinets and Racks for all your 19 needs

Submittal Data Performance Data Electrical Data

SmartShelter Room. Technical Description. Version 1.1 Jul. 2017

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles

OWNERS MANUAL. PLEASE READ THIS MANUAL BEFORE OPERATION

Downstream Equipment. Intelligent Air Technology

SYSTEMS GENERAL CATALOGUE

Reciprocating Compressors AIRBOX / AIRBOX CENTER

Fiber Optic Cable Fence Disturbance Sensor

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

Fincoil FMP and FMPG. Air coolers and liquid circulated air coolers

12 In Row. Installation Manual. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

ULTRA.GUARD ultra low temperature freezer

Greensource Residential Geothermal Heat Pumps. Invisible Comfort. Si Series: CE Model. boschheatingandcooling.com

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

FOGEL Caribbean Corporation

Largo & Allegro. Air Compressors. Largo & Allegro 31-90

Vacuum drying VD VDL series

CX1 ProVector Explosion-Proof Heaters

A cast iron case for our modular motors: High-voltage motors H-compact PLUS

Main technical datas:

Innovating Reliable Power

SPECTRACOOL Indoor & Outdoor Air Conditioners

PROAIR Harsh Environment/Wash Down Air Conditioners

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Product Management, Rev 3 December 2009

Specification and Manual

HVAC SYSTEMS COMMERCIAL VESSELS

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Laboratory refrigerators and freezers

ELSTA MOSDORFER- Energy Distribution with Competence

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

Fiber Distribution Box

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

THERMAL MANAGEMENT. Outdoor 3.13 to

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Rollair. Air Compressors. Rollair 40 to 125 and Rollair 40 V to 125 V

Refrigerant air dryers. FD series ( l/s, cfm)

Transportation. Distribution

AQUASNAP JUNIOR 30RHV

ENCLOSURE SYSTEMS. ATI Systems. Edition 9. ATI Systems International:

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

KELVIN Clim F497. Kelvin air conditioning

INDUSTRIAL AIR CURTAIN. IndAC 2

20 20 MARKET SOLUTIONS INSPIRATION INNOVATION INTEGRATION. Industrial Solutions

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

Top-Mount Air Conditioners

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Filtered Containment Venting System. Proven Technology Passive Operation

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

SPECTRACOOL Indoor & Outdoor Air Conditioners

Fibox FTTH Solutions

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

Quality Products. Service Excellence.

Flammables Safety Cabinets

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

Transcription:

inorax Outdoor Eclosures Protected like a bunker for all harsh environments 82

Outdoor enclosures and climate control components do withstand even the toughest environmental (sunlight, rain, ood, humidity, dust, so on) conditions. From basic requirements such as humidity, temperature uctuations and sunlight, to extreme conditions such as seawater resistance or vibration-earthquake resistance, through to protection against vandalism, Canovate has the answer. In this way, we ensure that there are no limits to our customers applications including DSLAM, MSAN, VDSL, 3G and 4G GSM networks, railway, energy and traf c monitoring and transmission applications. Canovate aluminum, stainless steel and galvanized steel based outdoor cabinets offer maximum protection against environmental impacts, vandalism, EMC and extreme thermal conditions. Canovate Outdoor Climate Control solutions provide everything you need to protect your electronic equipment investment. All weather-tested enclosure air conditioners, heat exchangers, fans, and heaters are especially designed for extreme outdoor conditions to ensure constant interior temperature performance. Double Layer Aluminum Double Layer Stainless/Galvanized Steel IP 55 protection Solid extruded aluminum pro le construction- Completely Weld free structure Double layer doors and panels with natural ventilation system and integrated isolation material Double layer construction (sandwich technology) ensures maximum heat dissipation by low in uence of sun irradiation and offers maximum sealing effect Special sun re ecting and anti-graf ti outdoor paint ensures up to 6 C temperature isolation Indoor paint ensures humidity absorbance by collecting humidity created by active devices on the surface of the inner roof Ventilated roof top ensures maximum ventilation through creating a chimney effect Special bumps on all doors and panels disables advertisement material posting on surfaces adversely effecting the appropriate ventilation required for heat exchangers and AC units Anti-vandal design External access totally impossible provided by hidden hinges Robust stainless steel locking system Maximum protection against environmental impacts, vandalism, EMC and extreme thermal effects 19 mounting rails for active equipment Separate battery, 19, MDF and other sections according to customized requirements Laptop shelves on doors Customer-speci c solutions for installation and future expansions Fully integrated heat exchangers, air-conditioning and internal heating are available upon request IP 55 protection Resistant construction against corrosion and harsh conditions Double layer doors and panels with isolation material inside Double layer construction with special isolation material (sandwich technology) ensures maximum heat dissipation by low in uence of sun irradiation and offers maximum sealing effect Special outdoor paint resistant to adverse weather conditions Separate battery, 19, MDF and other sections according to customized requirements Anti-vandal design Robust stainless steel locking system Maximum protection against environmental impacts, vandalism, EMC and extreme thermal effects 19 mounting rails for active equipment Customer-speci c solutions for installation and future expansions Fully integrated heat exchangers, air-conditioning and internal heating are available upon request 83

inorax-09 Outdoor Cabinet Frame : Extruded aluminum, thickness can be up to 4 mm Protection Level IP55 DIN 50939 chromating Technical Speci cations 3 sections: 19 Systems + MDF+ Power, 3 doors Top Mounted Heat Exchanger 1700 1155 414 OAD-7-1001 Top Mountable Heat exchanger Double Skin Door Power Box Section MDF Section 19 Active Equipment Section Thermal Test Thermal study for extreme climatic conditions are done in approved laboratories Boundary Conditions Temperature Distributions Streamlines, coloured with ow velocity 84

inorax-10 Outdoor Cabinet Frame : Extruded aluminum, thickness can be up to 4 mm DIN 50939 chromating Protection Level IP55 Technical Speci cations 4 sections: 2x 19 Systems + MDF+Battery, 7 doors Heat exchangers & AC units can be mounted on the doors 1500 1900 900 OAD-7-1002 inorax-11 Outdoor Cabinet Frame : Extruded aluminum thickness can be up to 4 mm DIN 50939 chromating Protection Level IP55 Technical Speci cations 3 sections: 19 Systems + MDF+Battery, 4 doors Heat exchangers & AC units can be mounted on the doors 1500 1600 900 OAD-7-1003 1390 1250 805 OAD-7-1004 Side View 85

inorax-18 Outdoor Cabinet Frame : Extruded aluminum thickness can be up to 4 mm DIN 50939 chromating Protection Level IP55 Technical Speci cations 7 sections: 19 Systems + MDF+ Power Distribution + Power meter + Fans+ 2 x Battery, Access is available from front, side, rear and top Height mm 1620 Width mm 920 Depth mm 450 Part No OAD-7-1005 inorax-19 Outdoor Cabinet Frame : Extruded aluminum, thickness can be up to 4 mm DIN 50939 chromating Protection Level IP55 Technical Speci cations 7 sections: 19 Systems+Battery+ MDF+ Power Distribution + Power meter+ Fan+ Cable Storage Access is available from front, side, rear and top, cable storage at the bottom Height mm Width mm 830 536 Depth mm 260 Part No OAD-7-1006 86

inorax-20 Outdoor Cabinet Frame : Extruded aluminum, thickness can be up to 4 mm Protection Level IP55 DIN 50939 chromating Technical Speci cations 3 sections: 19 Systems + MDF+ Power, 4 doors, Door Mounted Heat Exchanger 1475 1687 566 OAD-7-1007 inorax-13 Outdoor Cabinet Frame : Aluminum/ Stainless Steel/ Galvanized steel Doors and Panels:Double layer aluminum/stainless steel/galvanized steel thickness can be up to 4 mm DIN 50939 chromating Protection Level IP55 Technical Speci cations 4 sections: 2x 19 Systems + MDF+ Battery, 5 doors Heat exchangers & AC units can be mounted on the doors 1650 1774 790 OGD-7-1001 87

inorax-14 Outdoor Cabinet Frame : Aluminum/ Stainless Steel/ Galvanized steel Doors and Panels:Double layer aluminum/stainless steel/galvanized steel thickness can be up to 4 mm DIN 50939 chromating Protection Level IP55 Technical Speci cations 4 sections: 2x 19 Systems + MDF+ Battery, 5 doors Heat exchangers & AC units can be mounted on the doors 1650 1190 690 OGD-7-1002 inorax-21 Outdoor Cabinet This outdoor cabinet is an ideal solution for Power and Gsm based applications Frame : Aluminum/ Stainless Steel/ Galvanized steel Doors and Panels:Double layer aluminum/stainless steel/galvanized steel thickness can be up to 4 mm DIN 50939 chromating Protection Level IP55 Related Accessories Roxtec Special Cable inlet optional Earthing bar Depth adjustable 19 mounting rails and 2 sets of vertical organizer AC units can be mounted on the doors Height Width mm Depth mm Part No 39U 600 900 OAD-7-1008 Internal Cabling and Assembly Roxtec Cable Inlet 88

inorax-16 Outdoor Cabinet This outdoor cabinet is an ideal small size solution for any 19 active equipment installation and a perfect ber cross connect cabinet for FTTX applications. Single layer galvanized steel - 2 mm Protection Level Plinth 250 mm (H) plinth is included in standard con guration Finish Epoxy polyster outdoor paint, RAL 7035 Weather-proof outdoor cabinet for installation of 19 active equipment and optical distribution modules Assembly of modular optical building blocks like splice, patch and splitter modules Provides a secure anchor for incoming loose tube cables within the cabinet Easy installation and removal Doors are protected from external access through hidden hinges High resistivity against corrosion 1 pair of 19 inch mounting rails (Optional 2 pairs) Single front door CNC controlled polyurethane (PUR) gasketing is available for all of the complete openable surfaces of the outdoor to provide IP65 protection degree,which is complying with the EN6O529 standard 1,5 mm mounting plate for cable management on the back side C-rail for xing cables on the back side Optional: Mounting brackets for wall applications Ventilation unit on top (IP55 protection) Double front door Aluminum/Stainless steel material Height U Height mm Width mm Depth mm Weight kg Part No 12U 16U 24U 912 1090 1200 620 620 620 Minimum Order Quantity:10 Pcs. 450 600 600 53.00 64.00 82.00 IP65 OGS-7-1002 OGS-7-1003 OGS-7-1004 Ventilation Unit Option Top cover designed for air circulation Double front door option 89

inorax-17 Outdoor Cabinet SMC/Polycarbonate Cabinet An ultimate solution for outdoor copper cable connection and distribution applications. Special glass ber reinforced polycarbonate structure makes this cabinet an ideal solution for cross-connect applications of Telecom and Cable TV companies. The structure is a blend of low weight and high mechanical strength and its functional design gives extra advantages both for installation and cable management. Glass ber reinforced polycarbonate Protection Level Weather-proof outdoor cabinet for cross connect applications Double door access with 2400 pairs capacity (Krone Type) Front and rear door Locking systems: 3 points, 2 vertical bars, 1 lock Easy to install on a pedestal with bottom cable entries Impact resistant 4 Vertical mounting rails RAL7038 IP55 Height mm 998 Width mm 757 Depth mm 310 Weigth kg 50 Part No OPS-7-1001 inorax-23 Outdoor SMC/Polycarbonate Cabinet An ultimate solution for outdoor ber cable connection and also distribution applications. Special glass ber reinforced polycarbonate structure makes this cabinet an ideal solution for cross-connect applications of Telecom and Cable TV companies. The structure is a blend of low weight and high mechanical strength and its functional design gives extra advantages both for installation and cable management. Glass ber reinforced polycarbonate Protection Level IP54 Weather-proof outdoor cabinet for cross connect applications Double front door Door hinges circular type-stainless steel Locking systems: Latch-Type Cylindrical Lock 3 points, 2 vertical bars, 1 lock Professional cable management with suf cient number of entry holes (Suitable sized grommeeted or poke-out or punch-thruogh) for incoming feeder cables and distributions cables Plinth with 4 entry panels on the front and back for xing and management Cable Clamps to secure up to 18 mm diameter FOC. Impact resistant 4 Vertical mounting rails RAL7035 Height mm 1100 Width mm 1500 Depth mm 320 Weigth kg 50 Part No OPS-7-1002 90

Thermal Management Air conditioner Ensures that the proper interior temperature is maintained inside your enclosure. Conveniently mounted on the front or rear door with adjustable internal, mid, or external mounting cabability. These reliable products give you the exibility you need to meet the strigent requirements for your unique outdoor application Technical speci cations Capacitor Hot air Fan Cool air Fan Hot air Cabinet Refrigeration capacity: 300W - 3500W Noise level: 65 db, according to ETS300753 Class 4.1 IP54 protection Feeding: AC Designed to ease regular maintenance Quick-removable front casing Components designed for quick cleaning and maintenance Easy lter replacement Lower maintenance costs CE approved Compressor Evaporator Cool air Air to Air heat exchangers Outdoor Air to Air heat exchangers ensure that the proper interior temperature is maintained inside your enclosure. Conveniently mounted on the front or rear door with adjustable internal, mid, or external mounting cabability. These reliable products give you the flexibility you need to meet the stringent requirements for your unique outdoor application. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Technical speci cations Capacity: 30W/K to 120W/K IP54 protection Noise level: 75 db according ETS300753 Class 4.1 E Feeding: 48V DC, Closed Loop Cooling for Controlled Environments Ef ciently Coated Aluminum Heat-Transfer Core- Cross Flow Type Speed controlled fans CE approved External circulation Hot air Fan Thermal exchange area Cool air Internal circulation Cabinet Direct Air Cooling-Membrane Filter & Fan system Unlike bulky heat exchangers and air-conditioning systems, Direct Air Cooling (DAC) systems with Membrane Cooling Filters have fewer mechanical parts. They are also easier to incorporate into cabinet designs, and require less maintenance. These cooling filters reduce ongoing operating costs, because they use less energy than mechanical systems; and reduce overall cabinet size to save space. Reliable protection of system electronics requires highly efficient filtering of ambient air to remove submicron particles and aerosols while also preventing water ingress into the cabinet. This is best achieved by using membrane filter, which provides 99% particle filtration efficiency at the 0.3um level yet still allows high airflows. Not only do membrane filters eliminate costly failures caused by corrosion and other pollutants, but they are also maintenance free and have longer lifetimes than non-membrane alternatives. Membrane filters have been specifically developed for outdoor cooling and protection under extreme environmental and climatic conditions. Nominal dimension: 500 x 500 x 40mm Humidity resistance Classi cation EN779-F9 Initial charge loss 15MMca Door Impure air Fans Cabinet Filtered air Filter MEF 91