Eco. Hand dryer. Automatic. High Speed

Similar documents
Biobot Hand dryer. Automatic. High Speed

Business Hand dryer High Speed

Business² Hand dryer

Business². Hand dryer. High Speed

Executive. Hand dryer. High Speed

I storm. Circular High Speed Hand Dryer. Model N2 : I storm...,. Patent Pending. Operating Instructions and Parts Manual

Product Instruction Manual. Jetstream JET1600 (white) & JET1600BSS (brushed stainless steel) 1.6 kw automatic hand dryer V15.

The Complete Range of Hand Dryers

TSL hand dryer. installation + maintenance

HAND DRYERS

Hot Air Hand Dryer Range

BARDON ROUGHING-IN. A. Specifications A T01-D TOUCHLESS HAND DRYER INSTALLATION INSTRUCTIONS K-5486T

^ Blade Hand Dryer Model: GS-2006H SLV

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer

INSTALLATION INSTRUCTION for ceiling fan

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

18 INCH HIGH VELOCITY FLOOR FAN

IMPORTANT INSTRUCTIONS READ & SAVE

READ AND SAVE THESE INSTRUCTIONS

OPERATION AND INSTALLATION

THE VELOCITY PATTERN

ASHDOWN STOVE SUITE

CEILING FAN OWNER'S MANUAL

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

IMPORTANT INSTRUCTIONS READ & SAVE

INSTALLATION INSTRUCTIONS

The Finest Hand And Hair Dryers Available

Hand Dryers Air Curtains Soap & Paper Dispensers Foam Dispenser Sanitizer Dispenser Body & Hair Dryers Shoe Shining Machines Sensor Taps & Urinal

SECTION ELECTRIC HAND DRYERS. ** NOTE TO SPECIFIER ** Excel Dryer, Inc.; Electric Hand Dryers.

24 & 30 INCH DRUM FANS

150MM ELECTRIC EARTH BORER

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

WAILEA OWNER S MANUAL

#ADENCE4- $ESIGNED )NCLUDES #OOL4OUCH4- +ICHLER )NSTRUCTION #USTOMER KHA

HARTFORD SLIM ASSEMBLY INSTRUCTIONS. IMPORTANT - RETAIN FOR FUTURE REFERENCE - READ CAREFULLY.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

CEILING FAN OWNER'S MANUAL

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

CEILING FAN OWNER'S MANUAL

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

Condensing Units CUS 15-60

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Dear Customer. Contents. 1) Vantage Electric Radiator characteristics Pag.3. 2) Technical specifications Pag.3. 3) Warnings Pag.4

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

SECTION ELECTRIC HAND DRYERS

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Comfort. Description. Applications

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS USA

NON-SUBMERSIBLE WATER PUMP

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

CI/SfB (57.7) 1st Edition. Vent-Axia Hygiene Range

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Installation. Professional Built-In Electric Warming Drawers (Indoor and Outdoor Models)

1-3 Komaba-cho, Nakatsugawa City, Gifu Prefecture, Japan

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

MILLA ELECTRIC FIREPLACE

OPERATING INSTRUCTIONS

CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

INSTALLATION MANUAL Wolfen Slimline Hand Dryer Stainless Steel. Installation Details Warranty

Chest Freezer Instruction manual

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Installation. Built-In Electric Cooktop. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

GCW SERIES Gas Cylinder Warmers

RESIN FREESTANDING TUB

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

INSTRUCTION MANUAL (ATEX / IECEx)

AM 213 Installation Introduction

HS&S Alert No: 103 Date: 9 March 2017

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Sealed Electric Wall & Floor Mounted Towel Warmers. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual.

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Syrup Server. Thank You MODEL: SY MODEL: SY for purchasing this Syrup Server to heat and neatly dispense sticky syrups and sauces.

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

Insta-Therm Series Service, Installation and Operation Manual

e Bath Fan with Light User s Guide

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 12kW QUIKTHERM RETHERM OVENS

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

User Guide PLEASE READ BEFORE USE AND KEEP FOR FUTURE REFERENCE.

QUADRO COLLECTION COMPONENTS. Instructions for Use & Installation Plastic Anchor Threaded Wall Support Anchor Screw Threaded Long Tube

IMPORTANT INSTRUCTIONS READ & SAVE

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

15-Year Limited Warranty

Model: AC-108. Instruction Manual

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

Transcription:

Eco Hand dryer Automatic High Speed

300mm 175mm 280mm Item Category Operating Voltage Air Speed Output Air Output Temperature Motor Type Motor Thermal Protection Heater Element Heater Thermal Protection Drying Time Decibel Rating Circuit Operation Sensor Range Timing Protection Drip Proof Isolation Net Weight Shipping Weight Unit Size Approvals Item Code BE08W BE08S BE08C Technical Specifications Performance Data 220-240Vac, 50Hz, 900 WATTS 64 m/s, 140m³/h 77 F (25 C) - Ambient Temperature 68 F (20 C) 23,000 rpm, 650W, Brush Type, Dual Ball Bearings Auto Resetting Thermostat turns unit off, 240V at 221 F (105 C) - EURO Spec 250W Auto Resetting Thermostat turns unit off at, 149 F (65 C) Under 10 seconds 76 dba @ 1mtr Infared Automatic, self adjusting 100 mm 60 seconds auto shut off IP22 CLASS I 4.5 kg 5 kg 280mm W x 300mm H x 175mm D CE, WEEE, Greenspec Cover Type/Finish Die Cast Aluminium; Epoxy Polyester Powder Coating (White) Die Cast Aluminium; Epoxy Polyester Powder Coating (Silver) Die Cast Aluminium; Bright Chrome 2 Eco

General Safety Information WARNING Failure to properly ground unit could result in electrical shock and/or death. This product is intended for installation by a qualified service person. Use AWAG No.16 solid conductor for wiring. Disconnect power at the service breaker before installing or servicing. NOT FOR HOUSEHOLD USE - MAY CAUSE BURNS IMPROPRE A L USAGE DOMESTIQUE - PUET OCCASIONNER. NOTE: Do not install dryer over wash basin. Type Y attachment If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. All units must be supplied with a 3-wire service. The ground wire must be connected with the dryers back plate. Installation Installation must be carried out by a qualified electrician 1. Make sure power supply breaker is switched off. Installation must be carried out in accordance with the current edition of the local wiring regulations code having jurisdiction. Installation should be performed only by a qualified electrician. 2. Place template against wall at desired height (see mounting height recommendations) and mark locations of 4 mounting holes and wire service entry at knockout (KO) location. NOTE: For two or more dryers, dryers should be no closer than 24 inches (610 mm) on centre. Connections: a. Connect the live wire (coloured red or brown) to the terminal block marked L. b. Connect the neutral wire (coloured black or blue) to the terminal block marked N. c. Connect the ground wire (coloured green or green and yellow) to the green screw marked. Note that the colour of live and neutral wires depends on voltage of supply service. 5. Replace cover. Do not over-tighten screws. 3. Remove and retain 2 cover screws and cover. 4. Connect supply wires to terminal block where indicated and connect ground wire to baseplate with ground screw. Eco 32

Recommended Mounting Heights From floor to bottom of dryer. Men s Ladies Children, ages 11-17 Children, ages 3-10 Disabled 43 41 39 33 35 109 cm 104 cm 99 cm 84 cm 89 cm Cleaning and Maintenance All surfaces of the unit should be cleaned daily with a soft cloth dampened with warm, soapy water. Polish with a soft dry cloth. DO NOT use caustic solutions or abrasive cleaning materials on the drier. Operation No touch operation. Shake excess water from hands. Place hands under the outlet to start operation. Rub hands lightly and rapidly. Stops automatically after hands are removed. 4 Eco

Diagram and Parts List 1. Die Cast Cover 2. Motor Housing 3. Rubber Washer 4. Shock Absorber 5. Motor Rubber 6. Motor 7. Rubber Mounting 8. Blower Mounting Plate 9. Mounting Plate Screws 10. Electrical Terminal Block 11. Cable Clamp 12. Cover Screws 13. Nylon Bushes 14. Base Plate 15. Circuit Board Module 16. Circuit Board Cover 17. Heater Element 18. Baffle Plate 19. Air Outlet /baffle 20. Senor Bracket 21. Sensor Module 22. Sensor Screen Eco 5

FW3 LTD, Biodrier West Hill, Exeter, EX11 1LQ tel: +44(0)1404 814292 email: sales@biodrier.com