INSTALLATION &OPERATIONS MANUAL PORTABLE AIR CONDITIONER KOREL AIR CONDITIONING KMA1-12GRC FOR FUTURE REFERENCE

Similar documents
AIRE ACONDICIONADO PORTATIL

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use.

MOBILE ROOM AIR CONDITIONER

INSTALLATION &OPERATIONS MANUAL

Dual-Hose Portable Air Conditioner User Manual

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Instruction Manual. Portable Air Conditioner

PORTABLE AIR CONDITIONER

Moveable Air-conditioner User s Manual

ACCESSORIES INCLUDED

Downloaded from manuals search engine

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

Portable Room Air Conditioner and Heat Pump

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

Portable Air Conditioner

- Cooling - Heating - Dehumidifying - Fan. Please read this owner s Manual carefully before operating the unit. -1-

AC-12200E Portable Air Conditioner

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

15,000 BTU Portable Air Conditioner

MODEL: DC10RCDH / DC12RCDH

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

Sunleaves Air Conditioner

Operating Instructions

PORTABLE AIR CONDITIONER

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Air Conditioner Features...8 Operating Instruction Care and Cleaning...17 Before You Call...18 Major Appliance Limited Warranty...

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Reverse Cycle Portable Air Conditioner with Dehumidifier

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

PORTABLE AIR CONDITIONER (LOCAL)

PORTABLE AIR CONDITIONER

Mobile Type AIR CONDITIONERS (LOCAL AIR CONDITIONERS)

Portable Air Conditioner Instruction Manual

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

SERVICE NUMBER ( )

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

Mobile Type Air Conditioner

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

PC20-AMFII / PC40-AMF USER MANUAL

5) Do not start or stop the unit by inserting or pulling out the power plug.

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

ARTICA. 8000Btu. Room Air Conditioners Portable Range

Portable Air Conditioner USER MANUAL

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Local air conditioner

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Split Air Conditioner

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

KSD-35 DR11 KUE-35 DVN11

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Progress plus Instruction manual

WA-1240E: 12,000 BTU Cooling only WA-1240H: 12,000 BTU Cooling and Heating WA-1420E: 14,000 BTU Cooling only WA-1420H: 14,000 BTU Cooling and Heating

Split Air Conditioner

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Inverter Split-type Room Air Conditioner

53 KNL / 53 QNL OWNER S MANUAL

POLOCOOL USER MANUAL. For. PC-53AP/C 19,000 BTU(5.5kW) PC-44BP/C 15,000 BTU(4.4kW) PORTABLE REFRIGERATED AIR CONDITIONER

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Owner s Manual TABLE OF CONTENTS

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Trotec PAC FT 2600 Portable air conditioner

Owner's Manual TABLE OF CONTENTS

OWNER'S MANUAL MODEL: P-08PE P-12PE. For any service needs, call

PORTABLE AIR CONDITIONER (LOCAL)

OWNER S MANUAL. Portable Refrigerated Air Conditioner. CP12CW2 (English) (CP12CW2)

SPLIT - TYPE ROOM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

Dehumidifier. Model: GDN20AX-K4EBA1A GDN20AX-K4EBA1B

Owner's Manual TABLE OF CONTENTS

Portable Air Conditioner. Instruction Manual

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

PORTABLE AIR CONDITIONER

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

PORTABLE AIR CONDITIONER (LOCAL)

Transcription:

INSTALLATION &OPERATIONS MANUAL PORTABLE AIR CONDITIONER KOREL AIR CONDITIONING KMA-2GRC FOR FUTURE REFERENCE

Wiring diagram Cooling Heating HEATER ONLY THE UNIT WITH HEATING MODE HAS HEATER 2

The Wind Blowing Out, But The Cooling Effect Is Bad Causes Mistakes in temperature setting. The air filter is blocked by dust. The air inlet or outlet of machine is blocked. Turn the air conditioner on in very hot room. Cooling capacityis insufficient. The doors or windows are open. Noise or vibration Causes The ground is not level or not flat enough. Solutions Set a proper temperature, setting temperature should be lower than ambient temperature. Clean the air filter. Remove the obstruction. Allow additional time to remove stored heat from walls,ceiling, floor and furniture. Reconfirm the required cooling capacity with your dealer. Close the doors and windows. Solutions Place the unit on a flat, level ground if possible. CONTENTS Brief Introduction... Technical Specifications... 2 Parts Description... 3 Accessories... 4 Control Panel... 5 Operation... 5 Installation... 7 Maintenance... 9 Troubleshooting... 0 Wiring diagram... 2

Brief Introduction This mobile air conditioner is a new generation air conditioner which is ideal for using in bedroom, study room, lobby, office, meeting room, warehouse, attics, sports hall and other entertainment room. Its flexibility characteristic enable easy adjustment to desirable room temperature and humidity. Besides, the built-in filter can remove floating dust, purify air to create a healthy working environment. It is designed under novelty, practically and convenience principles to satisfy the needs for convenient, efficient and mobile small-sized air conditioner. It features easy using, no need for complicated installation and convenient maintenance. Besides, the double control system (remote control /manual control optional ) eases its operation. The unit is highly competitive to other cooling capable products. With tidy structure, multiple functions, auto-drain function and reasonable ventilation design, the unit minimizes noise and power consumption. Aiming at harmonious human life, our company adopts human factors into design, produced this high efficiency mobile air conditioner. Cleaning The Unit.For the purpose of safety, please turn off the air conditioner and cut off the power supply. 2.Wipe the unit with dry cloth. 3.If the unit is very dirty, please wipe with wet cloth dipped by cold water., Note: if you don t use the unit for a long time, please pull out the rubber plug to drain the inside water out referring to right figure. Do not use gasoline,benzene,thinner or any other chemicals, or any liquid insecticide on the air conditioner, as these substances may cause flaking off of the paint,cracking or deformation of plastic parts. Never attempt to clean the unit by pouring water directly over any of the surface areas, as this will cause deterioration of electrical components and wiring insulation. Never use hot water over 40 (04 )to clean the air filter. To save the cost of a service call, please try the suggestions below to see if you can solve your problem without outside help. Air Condition Will Not Operate Causes The power switch is released. Power supply failure. The fuse is burnt. It doesn't reach the set time for start up. Troubleshooting Solutions Switch on the power. Wait for the recovery of power supply. Replace the fuse. Wait or eliminate the original setting. Unit Doesn't Start When Pressing ON/OFF Button Causes It is not three minutes after switch off. Room temperature is lower than the setting temperature. Solutions Wait three minutes. Reset the temperature. 0

Window kit installation Your window kit has been design to fit most standard vertical and horizontal window applications. However, it may be necessary for you to improvise or modify some aspects of the installation procedure for certain types of window. Please refer to fig. A &fig. B for minimum and maximum window openings. Horizontal window Window slide kit minimum:67.5cm maximum:25cm Fig. C Nut Bolt Fig. A Window slide kit minimum:67.5cm maximum:25cm Note:The bolt and nut are used to fix window fixing board. Maintenance Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care for your air conditioner properly.. Cleaning Air Filter If the air filter is covered by dust, the cooling effect will be decreased. Please clean the air filter every two weeks.. Turn off the air conditioner and cut off the power supply. 2. Pull out the filter cover and remove the filter from cover. 3. Wash air filter in warm soap water. Do not put air filter in the dishwasher or use any chemical cleaners. And dry filter completely before replacing. 4. Attach the air filter to the filter cover using the attachment hooks on the inner surface of the cover. Put the filter cover back to its place. Fig. B Vertical window Technical Specifications Model Cooling capacity (Btu/h) 9000 Electric heating (W) 3 Air flow (m /h) Rated input current (A) Rated input power(w) Power supply Refrigerant Cooling Heating Cooling Heating Weight (kg) Noise db(a) Dimension(mm) Type of the fuse 2 Suitable room area (m ) AM-H09A4/BR Note:.The above cooling capacity are calculated at ambient temperature DB 30, WB 25.4. 2.Our company has quick technical improvement. There will be no prior notice for any change of technical data. Please read the nameplate on the air conditioner. 3. The working temperature range of the air conditioner is 8~35. 9 2 330 4.5 0-5 220-240V~/50Hz R407c 37 52 829 49 420 F3.5AL (250V 3.5A) KMA-2GRC 2000 2000 3000 7.95 330 4.5 7.95 050 050 750 750 4-20

Parts Description Duct mount instruction Air outlet Control panel. Put one side of duct to the exhaust air outlet of mobile air conditioner, According fix it with unit correspondingly, then turn right, Push it downwards, make sure that it is fixed thoroughly. 2 Handle recess Front panel Truckle 2. Put the other side of the duct to adaptor. 3. Put the adapor to a nearby window. Adaptor Remote controller FRONT VIEW Filter cover Air inlet Air filter (inside) Note:.The duct can be compressed to 450mm minimum and extended to 800mm maximum. It is better to keep the duct length to a minimum. 2.Stretching or bending the duct excessively will affect the cooling efficiency. (As the following fig. Show) Air intake(condenser) Rear panel Exhaust air outlet Do not! Yes! Down drain outlet Up drain outlet Drain cover board REAR VIEW 3 8

Deal with water condensate When the inside water tank is full, the water full display is lighted.. Open the drain cover and extract it upwards. 2.put one container or drain cover under the drain pipe, take off the plug on the drain pipe and let out the condensing water. 3.after let out all the condensing water, put the plug back onto the drainage outlet, then cover the drain cover. Down drain outlet Accessories Parts Parts name Quantity Duct Adaptor Windows installation board IMPORTANT: This water is not suitable for drinking. Alkaline batteries 2 Installation Guide of customer The customer should have a qualified power supply coincident with that printed on the tag of the air conditioner. Its voltage should be in the range of 90%-0% of its rated voltage. Must use special circuit and efficient grounding outlet matching with the plug of the air conditioner. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Select a best location.install the mobile air conditioner in a flat and spacious location where the air outlets will not be obstructed. 2.A minimum clearance of 50cm from walls or other obstacles should be kept. Note:.The air conditioner shall not be used in the laundry. 2.The plug shall be accessible after the unit is positioned. More than 50cm More than 50cm Remote controller bolt nut NOTE: This remote control is the general type, so some functions such as SWING, HEALTH,HUMIDITY,and FEELING are not avaiable for this unit. 7 4

Control Panel k j i h g f e d c m b a 5 4 3 2 Function buttons.on/off button Press this button to make the unit run or stop. 2. + or - button Press + or - button to set the room setting temperature increase or decrease. 3.MODE button Each time you press this button, a mode is selected in a sequence that goes from cool, dry and fan. 4.TIME button Press this button to initiate the auto-on or auto-off time sequence. 5.FAN button This button is used for setting fan speed in the sequence that goes from Low Med, to High, then back to Low. Function display a-signal receiver windows c-running indicator e-dry display g-cool display I-Med speed display k-temp. Display m- this display) Note :. Sleep function and Auto fan speed can be selected by remote controller not by control panel. 2. Other functions on control panel are as same as remote controller's. Operation b-water full indicator d-time display f-circulation display h-low speed display j-high speed display Electric heating(cold wind type unit with out WARNING Failure to follow the below precaution could result in electrical shock, fire or personal injury..the plug must be plugged into an outlet that is properly installed and grounded. 2.Do not use an extension cord or plug adaptor with this unit. Before starting the unit ) Select a suitable location, make sure the unit is near to an electrical outlet. 2) Install the flexible exhaust hose and the adjustable window slider kit. 3) Plug the unit into a right outlet. 4) Plug one end of drain pipe into the water full auto-drain outlet and plug the other end plug into the windows installation board. 5) Turn the unit on. Cooling operation mode. Press the MODE button in a sequence until the cool display is lighted. 2. Press the + and - button to set your desired set temperature. 3. Press FAN button to select the fan speed. 4. Press ON/OFF button to start the unit and press it again to stop. Drying operation mode. Press the MODE button in a sequence until the dry display is lighted. 2. The fan will run at a fixed speed at this operation mode. 3. Close windows and doors for the best dehumidifying effect. 4. Press ON/OFF button to start the unit and press it again to stop. Circulation operation mode. Press MODE button in a sequence until the fan display is lighted. 2. Press the FAN button to select the fan speed. 3. Press the ON/OFF button to start the unit and press it again to stop. Timer operation. Press the TIME button. 2. Press the + and - button to adjust your timer time. Note: Time off is effective only when the air-conditioner is running. Time on is effective only when the air-conditioner is stopping. 5 6