Instructions For A and Flame Simulators

Similar documents
R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

7800 SERIES RM7888A Relay Module

7800 SERIES RM7840E,G,L,M Relay Module

7800 SERIES EC7885A/RM7885A Relay Module

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

Honeywell Primary Control Cross Reference

C7005A,B Gas Pilot and Flame Rod Assemblies

7800 SERIES EC7823/RM7823 Relay Module

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

RA890G Protectorelay Primary Control

C554A Cadmium Sulfide Flame Detector

C7004B Flame Rod Holder

7800 SERIES RM7888A Relay Module

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

Commercial/Industrial Combustion Control Level Three Announcement

7800 SERIES EC7810A, EC7820A Relay Module

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

R7140G,L,M Burner Control Modules

C6097A,B Pressure Switches

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

The T6140A,B Remote Bulb Temperature Controller

RM7890; RM Vac 7800 SERIES Relay Modules

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

T7079A,B Solid State Remote Temperature Controllers

7800 Series RM7888A Relay Module

7800 SERIES RM7824A Relay Module

CR7075 Two-Stage Lighting Controller

T6984F,G Electronic Floating Control Thermostats

C7915A Infrared Flame Detector

RM7890D; RM7895E,F 7800 SERIES Relay Modules

T4398A,B High Performance Electric Heat Thermostats

T4098A,B Deluxe Electric Heat Thermostats

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

T7984 A,B,C Electronic Modulating Control Thermostats

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

R4348B INDUSTRIAL FLAME SWITCH APPLICATION PRODUCT HAND BOOK

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

7800 SERIES Relay Modules

F150E Media Air Cleaner

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Honeywell Thermal Solutions COMBUSTION CATALOG

T8011R Programmable Heat Pump Thermostat

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D 7800 SERIES Relay Modules

Solid State Burner Management Controls Series D10-20 for Automatic Burners

RM7897A,C 7800 SERIES Relay Modules

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

L8151A Triple Aquastat Relay

H1008A,D Automatic Humidity Controls

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

R7120M 7800 SERIES Relay Modules

R4140G Flame Safeguard Programming Controls

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

F200E Charged-Media Air Cleaner

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

COMBUSTION CATALOG. Honeywell Thermal Solutions Honeywell Thermal Solutions Combustion Catalog

Home and Building Control Home and Building Control Helping You Control Your World

RM7838A 7800 SERIES Relay Modules

Electronic Thermostat

C7012A,C,E,F,G Solid State Purple Peeper Ultraviolet Flame Detectors

HE365A,B Powered Flow-Through Humidifier

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

HE420A Steam Power Humidifier

C7061A,F Dynamic Self-Check Ultraviolet Flame Detector

SIL3. C7012A,C,E,F,G Solid State Purple Peeper Ultraviolet Flame Detectors. Capable FEATURES APPLICATION PRODUCT DATA. Contents C7012A,E,G C7012C,F

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

RA889A Switching Relay

SIL3. C7961E,F Dynamic Self-Check Ultraviolet Flame Detector. Capable APPLICATION FEATURES PRODUCT DATA. Contents

YP7899C SERIES Burner Management Panel

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

T8411R Electronic Heat Pump Thermostat

C7061A,F Dynamic Self-Check Ultraviolet Flame Detector

T8600D Chronotherm IV Deluxe Programmable Thermostats

T8602C Chronotherm IV Deluxe Programmable Thermostats

Indirect gas-fired air heater

Cleaver-Brooks CB780/CB784 Operation and Maintenance Manual

Sola Hydronic Control. An Eco-Friendly Solution.

F25F Media Air Cleaner

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

SOLID STATE Burner Management Controls SERIES D40-41

T874 Multistage Thermostat and Q674 Subbase

M6063A Compact Rotary Mixing Valve Actuator

T8611M Deluxe Programmable Heat Pump Thermostats

T6984 A,D,E Electronic Floating Control Thermostats

DIGITAL BURNER CONTROLLER DBC2000 SERIES

T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

CT1500, CT1501, CT1502, CT1503

Transcription:

Instructions For 123514A and 203659 Flame Simulators Application Flame simulators are devices that simulate a flame by reproducing ultraviolet resistance or rectification characteristics of an actual flame. Flame simulators simplify the troubleshooting of flame safeguard controls by providing a quick method to check the flame detection function. A simulator is typically used to simplify troubleshooting when: 1. The pilot lights but the flame relay does not pull in, or 2. Shutdown occurs during the run period. Using a flame simulator provides a quick, positive indication of the source of trouble in the flame detection circuitry. If the flame signal is unsteady or weak, a flame simulator enables the service technician to determine whether the trouble is in the flame detector, external circuitry, plug-in amplifier, or flame safeguard control itself. 123514A 203659 Features Provides a quick, positive indication of the source of trouble in the flame detection circuitry. Simulates flame by providing the ultraviolet resistance or rectification characteristics of the flame itself. Designed to plug directly into the flame signal meter jack, test jack or into direct contact on Honeywell flame safeguard controls or plug-in amplifiers. Specifications MODELS 123514A Flame Simulator brown, rectification type, for systems using rectifying flame rods, rectifying photocells, C7012A,C or C7020A Ultraviolet Flame Detectors. Use with flame safeguard controls. Refer to Table 1. 203659 Flame Simulator purple, ultraviolet, type, for systems using C7027, C7035, or C7044 Minipeeper Ultraviolet Flame Detectors. Use with flame safeguard controls and Minipeeper Flame Detectors. Refer to Table 2. WARNING A flame simulator must be used only for troubleshooting. The flame simulator must not be used for a permanent installation. Operation OPERATING INSTRUCTIONS Flame simulators are designed to plug directly into the flame signal meter jack, test jack or into direct contact with terminals on Honeywell flame safeguard controls or on plugin flame signal amplifiers. CAUTION Remove the flame detector leadwire to terminal F (or F1) on the terminal strip or subbase while using a flame simulator. In some cases (as shown in Fig. 5), a wire may have to be connected to the terminal strip or subbase to provide access to terminal F (or F1). Tables 1 and 2 and Figs. 1-23 show how the flame simulator is applied. If the flame simulator is applied properly, but the flame relay in the flame safeguard control does not pull in, the plug-in amplifier or the control itself is faulty. If the flame relay does pull in, the trouble is in the flame Ordering Information Specify 1. Order number. Order from 1. Your usual source, or 2. Honeywell Inc. 1885 Douglas Drive North Minneapolis, Minnesota 55422 (612) 542-7500) (In Canada Honeywell Controls Limited, 740 Ellesmere Road, Scarborough Road, Scarborough, Ontario, M1P 2V9). International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. P.G. Rev. 7-92 Honeywell Inc. 1992 Form Number 65-0093 1 1 65-0093 1

detector or its circuitry. For more details, refer to the Instructions for the flame safeguard control. NOTE: Flame simulators are not needed for self-checking flame detection systems. NOTES ON USING THE FLAME SIMULATOR 1. Only momentarily hold the simulator in position on the control. Whether the flame relay pulls in or not, remove the simulator as soon as the check is made. 2. If the control or amplifier has a meter jack (or test jack) in the F circuit, use the simulator to quickly check for a flame simulating condition that is preventing a start. Proceed as follows: a. If the flame relay is being held in and the burner cannot start, insert the simulator lead or plug into the meter jack. Hold the simulator probe end away from all metal parts to avoid completing the circuit to ground. This disconnects the flame detector circuit. b. If this causes the flame relay to drop out, a flame simulating condition exists (light reaching photocell, defective vacuum tube, hot refractory hold-in or a similar problem). If the flame relay does not drop out, replace the control. 3. See Figs. 1-23 for the procedures for checking the flame detecting function for each flame safeguard control. Refer to the Burner Control Instructions for the complete procedure for other troubleshooting problems. 4. If trouble is determined to be in the flame detector or in the detector circuit, look for the following causes: Short to ground; includes high resistance shorts caused by moisture or dirt buildup at the detector or control terminals. Burned-off flame rod. Flame rod not in flame. Insufficient ground area at flame rod. Blowing or lifting flame; wrong fuel-air mixture. Defective photocell. Dirty photocell, sensing tube, filter, lens or viewing window. Smoky flame. Detector not properly sighting flame. Hot refractory hold-in at end of burner operation. Defective electron (vacuum) tubes (C7012). Defective ultraviolet sensing tube. TABLE 1 APPLICATION OF THE 123514A FLAME SIMULATOR. Type of Flame Plug-In Flame Safeguard Using the Flame Simulator Detection System Amplifier Model Control(s) Plug End Probe End Fig. No. Rectification R177, R180, R187, Hold on terminals 1 (no test jack, or R190, R485A, R887, F and G on the test jack in R890, R7023A, RA190, control chassis. F circuit) and RA890E without a test jack. R485B, R7023B, Plug into test jack Hold G lug against 2 RA190B, RA890E on control chassis. metal frame or with a test jack, and subbase. RA890F,H,J,K. R7289A R4795 Plug into test jack Hold G lug against 3 (Green) on amplifier. subbase. Rectification R7242A R4075B, R4181A Plug into meter jack Hold on terminal F. 4 (meter jack in (Green) on front of control. G circuit) R4138A,B Plug into meter jack Tap against terminal 4 on front of control. F about once a second. R7253A R4126, R4127 Plug into meter Hold on terminal 5 (Green) jack on amplifier. F1 on terminal strip. R8169B Plug into meter Hold on terminal 6 jack on amplifier. F1 on terminal strip. R7257A R4150 Hold against Plug into tip jack 7 (Green) R4150 chassis. on R4150 chassis. Q518A, Q519A Plug into meter Hold on terminal 8 Multiburner Modules jack on amplifier. F. R7247A R4075C,D,E; Hold against Hold on terminal 9 (Green) R4138C,D control chassis. F. R4140 Hold against Plug into tip jack 10 control chassis. on R4140 chassis. R7847A,B 7800 SERIES Plug into (COM) Plug into S on 11 on amplifier. amplifier. 2

Fig. 1 Using a 123514A Flame Simulator with an R177, R180, R187, R190, R485A, R887, R890, R7023A, RA190, or RA890E without a test jack. Fig. 3 Using a 123514A Flame Simulator with an R4795 and R7289A Amplifier. HOLD PROBE ON HOLD PROBE HOLD PLUG END ON OR AGAINST SUBBASE M5216 HOLD PLUG END ON OR AGAINST SUBBASE R7289A PLUG-IN (GREEN) M5215 Fig. 2 Using an 123514A Flame Simulator with an R485B, R7023B, RA190B, RA890E with a test jack, or RA890F,H,J,K. Fig. 4 Using a 123514A Flame Simulator with an R4075B, R4138A or B, or R4181A. HOLD PROBE HOLD PROBE ON FOR R4075B OR R4181A; TAP ONCE A SECOND FOR R4138A OR B PLUG INTO METER JACK ON HOLD PLUG END ON OR AGAINST SUBBASE M5217 TERMINAL STRIP IN CABINET OR ON SUBBASE M5203 3 65-0093 1

Fig. 5 Using a 123514A Flame Simulator with an R4126 or R4127. Fig. 7 Using a 123514A Flame Simulator with an R4150. HOLD PLUG END AGAINST R4150 NORM. TEST PLUG PROBE INTO TIP JACK ON R4150 R7257A (GREEN) PLUG INTO METER JACK ON WIRE CONNECTED TO TERMINAL F1 Fig. 8 Using a 123514A Flame Simulator with a Q518A or Q519A Multiburner Module. M5207 M5208 R7253A (GREEN) HOLD PROBE ON 1 R7257A (GREEN) PLUG INTO METER JACK ON Fig. 6 Using a 123514A Flame Simulator with an R8169B. HOLD PROBE ON APPROPRIATE F TERMINAL M5206 R7253A PLUG-IN (GREEN) Fig. 9 Using a 123514A Flame Simulator with an R4075C,D,E, or R4138C,D. HOLD PROBE ON HOLD PROBE ON 1 HOLD PLUG END AGAINST PLUG INTO METER JACK ON M5209 TERMINAL STRIP IN CABINET OR ON SUBBASE M5204 4

Fig. 10 Using a 123514A Flame Simulator with an R4140. Fig. 11 Using 123514A Flame Simulator 7800 SERIES Amplifiers. PLUG PROBE INTO TIP JACK ON R4140 R7247A (GREEN) TIP JACK INSERT PROBE INTO THE S TIP JACK ON PREPURGE TIMER DIAL POWER FLAME PILOT MAIN ALARM RESET INSERT PLUG END INTO THE TIP JACK ON S 7800 SERIES () M5210 PROGRAMMER HOLD PLUG END AGAINST R4140 M5205 TABLE 2 APPLICATION OF THE 203659 ULTRAVIOLET FLAME SIMULATOR. Type of Flame Plug-in Flame Using the Using the Detection Amplifier Safeguard Flame Simulator Flame Simulator Fig. System Model Control(s) Black Probe Red Probe No. Minipeeper RA890G Hold on terminal Hold on terminal F. 18 Ultraviolet R7290A (Purple) R4795 G or against Hold on terminal F. 20 Flame Detector R7255B (Purple) R4126, R4127 control chassis. Hold on terminal 13 (C7027, C7035, F1 on terminal strip. C7044) R7259A R4150 Plug into jack on 15 R4150 chassis. R7259A Q518A, Q519A Hold on terminal F. 16 Multi-burner Modules R7249A R4075B,C,D,E; Hold on terminal F. 12, 17 R4181A, R4138A,B,C,D R7249A R4140 Plug into tip jack 19 on R4140 chassis. R7249A BC7000 Plug into tip jack 22 on BC7000 chassis. R7255B R8169B Hold on terminal F. 14 R7795A,C,E,G Hold on terminal F. 21 R7849A, R7849B 7800 SERIES Plug into (COM) Plug into S on 23 on amplifier. amplifier. 5 65-0093 1

Fig. 12 Using a 203659 UV Flame Simulator with an R4075B, R4138A,B or R4181A. Fig. 14 Using a 203659 UV Flame Simulator with an R8169B. HOLD PROBE ON FOR R4075B OR R4181A; TAP ONCE A SECOND FOR R4138A OR B RED METER JACK R7255B PLUG-IN (PURPLE) HOLD PROBE ON 1 BLACK RED BLACK BLACK OR TOUCHING M3133 M3140 TERMINAL STRIP IN CABINET OR ON SUBBASE Fig. 15 Using a 203659 UV Flame Simulator with an R4150. HOLD AGAINST R4150 Fig. 13 Using a 203659 UV Flame Simulator with an R4126 or R4127. BLACK RED NORM. M3134 PLUG PROBE INTO TIP JACK ON R4150 R7259A (PURPLE) TEST R7255B (PURPLE) PLUG-IN HOLD RED 1 Fig. 16 Using a 203659 UV Flame Simulator with a Q518A or Q519A. BLACK (ON OR ) R7259A (PURPLE) BLACK (ON ) WIRE CONNECTED TO 1 M3132 HOLD PROBE ON APPROPRIATE M3135A RED 6

PREPURGE 123514A/203659 Fig. 17 Using a 203659 UV Flame Simulator with an R4075C,D,E, or R4138C,D. Fig. 19 Using a 203659 UV Flame Simulator with an R4140. HOLD RED ON AGAINST OR PLUG RED INTO TIP JACK ON R4140 TIP JACK PROGRAMMER R7249A (PURPLE) M3136A TERMINAL STRIP IN CABINET OR ON SUBBASE AGAINST R4140 M3138 TIMER DIAL Fig. 18 Using a 203659 UV Flame Simulator with an RA890G. Fig. 20 Using a 203659 UV Flame Simulator with an R4795 and R7290A Amplifier. HOLD RED ON HOLD RED ON F TEST JACK OR M3137 G OR R7290A (PURPLE) M3139 7 65-0093 1

Fig. 21 Using a 203659 UV Flame Simulator with an R7795A,C,E,G. HOLD RED CAUTION: DISCONNECT POWER BEFORE INSTALLING OR REMOVING WITH LOSS OF FLAME: CLIPPED JUMPER = LOCKOUT UNCLIPPED JUMPER = XXXXX FLAME CLIPPED JUMPER = 4 SEC. T. F. I. UNCLIPPED JUMPER = 10 SEC. T. F. I. M3145A Fig. 22 Using a 203659 UV Flame Simulator with a BC7000. Fig. 23 Using a 203659 UV Flame Simulator with 7800 SERIES Amplifiers. PLUG RED INTO TIP JACK ON BC7000 BC720- - - - - - STANDBY PREPURGE HOLD IGN TRIAL FLAME ON RUN POSTPURGE MICROCOMPUTER BURNER SYSTEM 203659 FLAME SIMULATOR POWER FLAME PILOT MAIN ALARM RESET RED PLUG PROBES INTO TIP JACKS ON BLACK AGAINST BC7000 BC7000 S 7800 SERIES () M3143A M3144 Home and Building Control Home and Building Control Honeywell International, Inc. Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 8 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.