EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS

Similar documents
more than M A N U FA C T U R I N G F R E E Z E R S U LT

EVOSAFE TM -SERIES ULTRA-LOW TEMPERATURE FREEZERS

MICRO CLIMA-SERIES TM (COOLED) INCUBATORS AND WALLS

MICRO CLIMA-SERIES TM PREMIUM ICH INSECT CHAMBER

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

Protect your research

DOUBLE DOOR FREEZER.

TwinGuard ULTRA LOW TEMPERATURE FREEZERS

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

-86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES

ULTRA.GUARD ultra low temperature freezer

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

PR / MP I Laboratory / Medicine

Refrigerators & ULT Freezers

New. ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1

Ultra low temperature freezers. -40 C and -86 C. Green Line

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES

Thermo Scientific Revco UxF -80C Series Upright ULT Freezers

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

Octalarm-T: the latest in future-proof industrial alarm diallers

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Refrigerated Incubators / Environmental Testing Chambers

Protection, safety, reliability. And more.

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

REAL TIME LABORATORY MONITORING SYSTEM

Medical Refrigerators

Refrigerated Incubator Model and Operating Instructions

Multi-Lab REFRIGERATORS Frigidere medicale

Compact Ultra Low Temperature Chamber

REFRIGERATOR M E D I C A L.

Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program

CLIMATRON GROWTH CABINETS

Chromatographic Air circulated Refrigerator, two-door TC 603

Cold chain monitoring technologies. Facility monitoring

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

SNIJDERS LABS EXPERIENCED INNOVATORS. MICRO CLIMA SERIES ARABIDOPSIS CHAMBER, type MCA1600. MCA1600 Pagina 1 van 11 STEK ISO9001:2008 CERTIFIED

Biomedical Freezer 37 38

Laboratory refrigerators and freezers

Altitude Chambers.

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

Tabletop 2340 EA-D Class S Autoclave 19 Litres

Chromatographic Air circulated Refrigerator, two-door TC 603

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

CSF. Contact Shock Freezers. Blood Management Solutions. B Medical Systems CSF Range

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

-86 Ultra Low Temperature Freezer


Ultra Low Freezers. Blood Management Solutions. B Medical Systems U Range

Dew point set DS 400

DATAssure. Laboratory wireless alarm & monitoring system

Ultra-Low Temperature Freezer powered by Smart-Lab TM System

Reliable cooling solutions...

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

-1050C FREEZER NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Benchtop & Compact Test Chambers

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

LABorAtory refrigerators

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

IceSpy System5. A big deal in the world of large scale environmental monitoring INDUSTRY SPECIFIC PRODUCT SOLUTIONS HEALTHCARE.

laboratory & sterilization technology

Heated and Refrigerated Incubators

Laboratory Refrigerator/Deep Freezer TC 802

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

Laboratory Freezers. Medical Refrigeration. B Medical Systems F Range

Ice Lined Refrigerator User Operation & Maintenance manual

MEDICAL REFRIGERATORS

Setting the Benchmark

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

Advance Blood Storage system from Meditech

Walk in Freezer. Comfortable work environment

ThermoControl 0 C - 10 C - 20 C - 30 C

REFRIGERATORS AND FREEZERS. laboratory chromatography ultra low temp pharmacy vaccine hazardous flammable undercounter performance qualified

BIOMEDICAL REFRIGERATORS

MIRADOR Real Time Monitoring

MEDICAL CHILLER SYSTEMS

KEY CONSIDERATIONS WHEN PURCHASING AN ULTRA-LOW TEMPERATURE FREEZER

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Blood bank refrigerators

IceSpy System5. A big deal in the world of large scale environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS COMPLIANCE REGULATORY

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

Thermo Scientific ULT Freezers: Superior Thermal Performance

Reproducible Climate...

SAVING LIVES THROUGH RELIABLE AND INNOVATIVE TECHNOLOGY. Medical Refrigeration

Transcription:

EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS

ULTRA-LOW TEMPERATURE FREEZERS A full range of Ultra-Low Temperature freezers (-86 C), vertical as well as horizontal, in capacities from 120 up to and incl. 965 ltr. Designed to protect your samples and to save energy at the same time. Snijders Labs has been manufacturing Ultra-Low Temperature (ULT) freezers for over 30 years. The company is ISO-9001 certified for Development, Manufacturing, Sales and Service. Snijders Labs operates worldwide by co-operating with factory certified and trained distributors for installation and service of the freezers. By adapting to customer requirements, focusing on technology and functionality, we are able to strengthen our market position and quality.

VERTICAL FREEZERS (VF)-86 C AND HORIZONTAL FREEZERS (HF)-86 C IN VARIOUS CAPACITIES. VF1000-86 VF830-86 VF720-86 VF620-86 VF475-86 VF360-86 VF240-86 VF120-86 HF570-86 HF400-86 INSULATION TECHNOLOGY The EvoSafe-series are fitted with an unique insulation method EXAMPLES OF TEMPERATURE RISE DURING POWER FAILURE CONCLUSION With any brand using vacuum insulation the Pull down period to a PC based coolant dosing system. It is an unique system designed specifically for Snijders. The system can fill to an installed between the interior and exterior. A combination of PU Pull-up example from a freezer with vacuum insulation is comparable to the EvoSafe TM freezers. However the difference accuracy of 0.1 gram. Each freezer is tested for leaks three blocks with two component foam is used (the so-called foam in place insulation). This system ensures that all the cooling is transferred to the interior of the freezer and hence improves considerably the insulation value over vacuum panel technology (see the comparison in the below pull-up graph). VACUUM INSULATION OR PU The internal and external dimensions of the EvoSafe-series TM are tailored to the European metric system to take European Temperature ( C) 0-10 -20-30 -40-50 -60-70 -80-90 -100 0 1 2 3 4 5 6 7 8 9 Time (hour) in the Pull up time is clearly visible. A freezer with vacuum insulation during a power failure reaches -10 C (from -86 C), within 9 hours. With the PU foam in place insulation of the EvoSafe-series it takes 12 hours before the freezer reaches -10 C (from -86 C). STATE OF THE ART ULTRA LOW TEMPERATURE COOLING The EvoSafe-series is the result of 30 years of experience times. It s tested on temperature in our own temperature controlled test facility. inventory systems, in contrast to other Asian and American Pull-up EvoSafe TM VF720-86 with Cascade cooling technology. They are designed for high producers. This allows a greater capacity of boxes to be stored while keeping the external dimensions to a minimum, even when using polyurethane insulation. Ask for EvoSafe-series TM datasheets for more information on the exact numbers of boxes and the total numbers of samples stored. Temperature ( C) 0-10 -20-30 -40-50 -60-70 -80-90 -100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Time (hour) performance, sustainability, energy efficiency and low noise output, due partly to the selection of the L Unité Hermétique compressor silent range. The cooling system layout has been improved to allow all the heat generated in the engine room to be discharged directly to the rear and out of the compartment. The EvoSafe cooling system has been filled with non-flammable, environment friendly CFC and HCFC free refrigerant. The ULT freezer performance and consistency is greatly increased due

Display 4-digit 7-segments for temperature/setpoint and parameters readout. Status LED s LED Cool=Cooling active LED Backup=CO 2 active UP and DOWN keys to adjust setpoint and parameters. Setpoint key to read/adjust setpoint. Prg key with indication LED for entering the program mode. Mute/Batt. key for reset alarm and battery status. Code key with indication LED for entering authorised access. ENERGY CONSUMPTION The graph on the right gives a representation of the energy consumption in Watts, per box, per hour and is based on the EvoSafe TM model VF720-86 (capacity: 528 pcs. 50 mm boxes). For comparison the graph shows a freezer with a similar capacity selected from the Asian and American markets. 3,5 3 2,5 2 1,5 1 0,5 0 Scheme energy consumption. EvoSafe-series Asian brand American brand Temp. low LED warning temperature too low. Temp. high LED warning temperature too high. Low Batt. LED warning battery is low. Power on/off key to switch the controller on/off (authorised access). WATER COOLING OPTION Our ULT freezer can be executed with a water-cooled condenser CAPACITY Maximisation of capacity, calculated in litres, was achieved WEB BASED CONTROLLER WITH IFREEZE TECHNOLOGY COMMUNICATION WITH THE FREEZER There are three different ways to communicate with the freezer which uses between 5 to 10% less energy. This system rejects by matching the internal dimensions to the standard box and The controller is the brain of the freezer, which uses the most as shown below in the scheme diagrams. less heat to atmosphere and therefore there are significant cost racking system used throughout the world. This results in advanced measurement and control techniques. savings to be made by using less air-conditioning to cool the more boxes per freezer, a lower volume in litres and therefore Developed specifically for the EvoSafe-Series, to give 1. Through USB-port ambient in the space where the freezers are located. optimum sample storage capacity. maximum security and reliability, including modern multimedia The temperature can be read graphically by a computer and communication technologies. program. The USB-port is located behind the removable Brand A EvoSafe-series condenser plate. After installing the Snijders ifreeze log-viewer 725 litre freezer with 3 inner 720 litre freezer (VF720-86) software, the chart can easily and quickly be read on any doors. with 2 inner doors. Windows PC. The chart can also be viewed and stored by a Total capacity: Total capacity: direct connection to a PC or laptop. 504 pcs. 4 x 50 mm boxes. Racks required : 18 pcs. 528 pcs. 4 x 50 mm boxes. Racks required: 12 pcs. single Fig. Scheme 1 through USB-port or 6 pcs. double. Standalone Freezer USB-stick USB-stick Laptop

2. Via a local network If a local network () is available a user can view the status of the freezer through the web page Freezer Statistics. For example: the actual temperature, set point, ambient temperature, door open or closed and/or whether there has been an alarm. This application is also suitable for simultaneous use. 3. Via Internet To expand communication capability it is possible to access the freezer(s) through any internet connection. This requires a right to be called up to enter the local network via internet. IFREEZE LOGVIEW By one of the three aforementioned forms of communication, the temperature log of the freezer can be retrieved. Through the 512 MB memory the freezer logs every 20 minutes the most critical parameters. The maximum storage is 6 months. In the example on the right, you can see a temperature-time log graph. Legend graph: Adjust temperature ( C) Condensor temperature ( C) Set point ( C) Battery voltage (Vdc) AC In the status bar below the chart is stated when these functions have been active. Fig. Scheme 2 via a local network /Intranet Freezer-1 Local PC FREEZER STATISTICS By using the standard web interface including an unique TCP/ IP address, it s possible to approach one or more freezers. In this way it will be possible to look at a number of important parameters, for example: Freezer-2 + set temperature and actual temperature + if the fan is running + if the door is closed + if there is an alarm or has been an alarm. Intranet Fig. Scheme 3 via internet /Intranet to /Intranet Freezer-1 Server PC Freezer-2 INTERNET www.snijderslabs.nl Intranet PC/Laptop

FREEZER DETAILS Capillary CO 2 emergency cooling system Flexible interior for each type of rack Division 1 2 compartments/10 racks. Division 2 4 compartments/20 racks. High quality stainless steel interior Vacuum release Receiver lock Door heating Stainless steel platforms, removable and height adjustable Insulated stainless steel inner doors One movement handle with cylinder lock Platform 1 Platform Platform 2 Platform 3 Door seal Internal door closure Machine room USB port located behind the removable condenser plate Door alarm switch Condenser + filter FLEXIBLE DIVISIONS All upright freezers are fitted with in height adjustable platforms allowing virtually any format and any type of rack to be used. ALARM FUNCTIONS In the event of a failure or warning, the freezers are equipped with various alarms. Each alarm has an unique code that is seen Web based controller with ifreeze technology 4 castors; the front two with brakes The example above is of the VF620-86 freezer with 2 different divisions (2 and 4 compartments). on the display of the controller. There is a mute button for audible alarm. Available and selectable alarm functions: REAR FREEZER DETAILS SAFETY Monitoring 24 hours a day 7 days a week. minimum or maximum temperature exceeded door alarm damaged sensor (in cabinet and/or condenser) Alarms will be notified, acoustically and visually, through a code battery voltage too low in the display and via the potential free contact. battery empty CO 2 fuse CO 2 connection SMS Novo alarm (optional) Potential free contact Normal use and preventive maintenance increases the lifetime of the EvoSafe freezers. EUROPEAN QUALITY All installed electronic and cooling components are sourced voltage deviation ambient temperature too high power fan failure back up alarm telephone dialing system alarm. 2 Spacers Power cable connection from reputable European brands. This selection process has a positive effect on the lifetime of the freezers. For example: L Unité Hermétique compressors, EBM ventilators, Siemens time relay, Jumo sensors, DuPont refrigerant and Danfoss The ways in which the freezer alarms: acoustically via a buzzer visually in the display by a code and/or LED indication components. Our suppliers comply with the latest European via an e-mail (optional) directives in the field of energy saving, environment and safety. via an SMS text message (optional) No low-cost components are used, thereby ensuring quality and via the potential free contact to a BMS reliability. (Building Monitoring System).

G M CRYOTHEQUE BIOBANK In addition to the manufacturing and delivery of ULT freezers Snijders also offers the facility to store the valuable samples of customers in either their own ULT freezers or ones supplied by us in our fully conditioned storage facility. This facility includes temperature controlled storage rooms, fitted with all necessary safety devices for 24 hours a day, 7 days a week. For example: burglar and fire alarm, temperature logging and alarms, emergency power, visitor registration and backup freezers if required. This offers advantages such as: maximum security during the storage of your samples freezers no longer located at the customers site, hence saving space, no heat removal requirements, no excess noise, energy saving and no maintenance or malfunctions spreading costs opportunity for third party clinical trials risk management of the unique collection of patient DNA or irreplaceable material. SNIJDERS LABS: EXPERIENCED INNOVATORS SNIJDERS LABS forms part of the Snijders Group, which actively delivers equipment and products for scientific research & development as well as internal transport systems and examination couches for the health care sector under SNIJDERS CARE. All design, manufacture and testing is held in house to assure high quality production and investment in new technologies for the production of all Snijders products. The total control of the manufacturing line means that Snijders can offer total quality, in-depth knowledge and detailed assistance to all of their clients. SERVICE AND WARRANTY Contact your local distributor who will guarantee quality and service (if necessary check our website for distributor details). VISIT OUR WEBSITE WWW.SNIJDERSLABS.COM There you ll find all the latest information about: + a variety of climate cabinets for plants, seed germination, fungi, snails and insects research with temperature-, light- and humidity control + (cooled) incubators and incubator walls, designed for general microbiological research of among others food, water and medical laboratories. + stability chambers. *Specifications subject to change E R A N Y Derde druk 2014 Office and Production Showroom and Testfacility Laurent Janssensstraat 105 Gebroeders Salastraat 40 5048 AR Tilburg 5048 AL Tilburg T +31 13 750 15 55 info@snijderslabs.com The Netherlands The Netherlands F +31 13 463 86 35 www.snijderslabs.com