VZ Chiller series. Water cooled inverter chiller. The highest peak in chiller technology

Similar documents
Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

EWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

DAIKIN Air Handling Unit Modular

Air Conditioners Technical Data

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioners Technical Data

Pure comfort & design

Daikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Air Conditioners Technical Data

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

water-cooled CHILLERS

Air conditioners Heating & Cooling

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Air Purifiers. Technical Data MC70L

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Fan Coil Units. Technical Data FWC-BT/BF

WATER-COOLED CHILLERS and condenserless chillers

Air Conditioners Technical Data

Pure comfort & design

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air conditioners Heating & Cooling

Daikin Altherma hybrid heat pump. The natural combination

Product portfolio. Chillers and air side equipment

Remote control infrared ARC433B76 ARC433A8 ARC433B69

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

water-cooled CHILLERS

Air Conditioners Heating & Cooling

Chillers. Technical Data. EWYD-BZ 250~580 kw

Air conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Pure comfort & design

Air Conditioners Heating & Cooling

EWWD MBYN EWLD MBYN Applied systems

Air conditioners Cooling only

where innovation meets creativity

The natural ombination

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

Our mission: beating the winter cold

Air Conditioners Technical Data

Air Conditioners Heating & Cooling

GAS CONDENSING BOILERS RELIABILITY AND PEACE OF MIND

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

Air Conditioners Heating & Cooling

Air conditioners Heating & Cooling

Pure comfort & design

Air conditioners Heating & Cooling

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

The plug & play fresh Air Solution

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump

Air Conditioners Heating & Cooling

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

Daikin Altherma Low Temperature monobloc heat pump

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

Air conditioners Heating & Cooling

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Water-cooled chillers Remote condenser chillers NEW

Air Conditioners Heating & Cooling

Daikin Altherma Low Temperature monobloc heat pump

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Air conditioners, heating & cooling for the retailmarket and offices

VRV The total solution. Integrated Climate Control

Europe s new energy label: raising the bar on energy efficiency

Daikin leads the way:

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air Conditioners. Technical Data FTY-H

AIR CONDITIONERS, HEATING & COOLING for your home

for your home FLXS-B Flexi type unit air to air heat pumps

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

for small rooms in multi application

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Heating. Technical Data EEDEN ERRQ-AY1

Air conditioners, heating & cooling for shops,restaurants and offices

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

air-cooled CHILLERS APPLIED SYSTEMS EWAD AJYNN EWAD AJYNN/A EWAD AJYNN/Q EWAD AJYNN/H

Commercial and Technical Data

Transcription:

VZ Chiller series Water cooled inverter chiller The highest peak in chiller technology

The highest peak in chiller technology EWWD-VZ chiller series An increasing demand for high efficient HVAC systems drives our product development mission. By answering market demands and offering new opportunities we anticipate on the future HVAC market needs. 8.0 7. 7 7.1 2

ESEER up to 8.5 7. 9 Top efficiency ESEER The EWWD-VZ chiller series were developed and manufactured to answer the growing market demands on high efficient chiller series. Thanks to the continuous evolution in components technology, we are the first to reach the highest peak in chiller efficiency and technology. 3

Single compressor 450 kw - 1,053 kw Full inverter water cooled chiller Highest efficiency in the market in its category TOP CLASS EFFICIENCY

Dual compressor & dual circuit unit 1,200 kw - 2,100 kw 2 of everything: 2 compressors, 2 expansion valves, 2 condensers,... New condenser design with integral oil separator High efficient flooded heat exchangers Unique Daikin single screw compressor technology 5

The highest peak in chiller technology Why choose EWWD-VZ chiller series? Top class efficiency: ESEER up to 8.5 EER up to 5.8 New generation Daikin inverter single screw compressors Importance of ESEER: Power consumption significantly reduced at part loads where the machine will run for 97% of the operation hours (Eurovent load profile) Power input 100% 90% 80% 73% 60% 50% 40% 30% 20% 10% 0% Traditional screw compressor - 32 % Screw compressor INVERTER driven 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% Compressor Load Why choose an inverter chiller? -25% energy consumption -25% CO 2 emissions -25% running costs Return on investment < 2 years vs non-inverter chiller Why are we better than others? Full inverter capacity control down to 20% No inefficient mechanical unloading slides % of full load power input non inverter 100% 80% 60% 40% Daikin EWWD-VZ 41% 33% 23% 45% 40% 35% 30% 25% 20% 15% Running hours 100% 50% Compressor speed Others Savings Mechanical unloading < 50% 20% 0% 3% 100% 75% 50% 25% 10% 5% 0% Unit capacity 20% Daikin EWWD-VZ Full Load 50% Load 20% Load (min) Compressor load Full inverter control down to min load! 6

New generation high efficiency heat exchangers Flooded type technology allowing maximizing unit performances Latest technology enhanced surface tubes Evaporator tubes: Outside: Cavities for optimized nucleate boiling Inside: Helical structure Condenser tubes: Outside: Optimized for condensation Inside: Helical structure Optimized design Pressure drops reduced by half meaning 1 C lower condensing temperature ū ū + 3.5 % efficiency Did you know that you can maximize your BREEAM and programme score and LEED green building programme score with the Daikin HVAC solutions? 7

The highest peak in chiller technology 2 Compact unit Small footprint, ideal for installation through existing doorways Width reduced below 900mm with knock down panel options* * 900 kw unit size 1245 mm 865 mm 40 % footprint reduction in comparison to traditional water cooled series thanks to: 1. New single pass condenser technology.. High heat exchange performances thanks to couterflow design.. Low water pressure drops < 30 kpa 2. New integrated oil separator technology.. Low oil carry over.. Low refrigerant pressure drops REFRIGERANT WATER Oil separator Condenser 3 Application flexibility Widest operating envelope in its range: The large operation range makes this chiller ideal for a variety of applications: Condenser water ( C) Up to 65 C hot water production and with optimized efficiencies Evaporator Water down to -8 C Heat pump Widest operating envelope in its category not only for comfort cooling Evaporator Water up to +20 C Brine/Ice storage Comfort Data center Evaporator water ( C) 8

The highest peak in chiller technology 4 Connectivity Remote access with one click Remote monitoring System optimization Preventive maintenance Dashboards Remote HMI access Remote maintenance report Remote software upgrade Daikin on site Cloud platform Via LAN or GSM modem Diagnostics 5 Future readiness: Choose for today s best solution and be ready for the future! R-134A refrigerant, still today the best possible choice: Still most efficient refrigerant. Availability in high quantitates and at competitive prices. No phase out planned in F-GAS regulation. Classified as non flammable All VZ units are new refrigerant ready! Possibility to retrofit them in the future with lower GWP refrigerants (HFO blends). 9

Supporting tools Product video Marketing material All marketing material and tools for the EWWD-VZ range can be downloaded from the business portal. Asset finder > Campaign > VZ chiller series Score credits per BREEAM category. Each category carries a certain weight that affects the score. Levels of certification: Green Building Design % score 14% 12% 10% 8% 6% 4% 2% 0% 85% Outstanding 70% Excellent 55% Very good Typical HVAC energy 45% Good consumptions in buildings 30% Pass < 30% Unclassified 11 *Based on BREEAM International New Construction 2015 Carbon and energy Materials Local wellbeing Resilience Offices : up to 48% energy Hotel : up to 70% energy Innovation Transport Integrated design Stakeholders Highest Focus Encourages specification and design of energy efficient solutions for construction and operation of the infrastructure Green Building Design Land use and ecology Pollution Landscape and heritage Waste Water Source : 1. EIA Commercial Buildings Energy consumption survey ; 2. Energy conservation centre, 2009 Web Want to know more about this product? Have a look at our dedicated webpage: www.daikineurope.com/vzchillerseries Technical specifications - single compressor range Standard efficiency, standard sound Cooling only /Heating only EWWD600VZSSA1 EWWD700VZSSA1 EWWD760VZSSA1 EWWD890VZSSA1 EWWDC10VZSS Cooling capacity Nom. kw 610 704 757 894 1,039 Heating capacity Nom. kw 756.7 877.8 943.2 1,107 1,292 Power input Cooling Nom. kw 110 132 142 162 196 Heating Nom. kw 140 166 179 201 244 EER 5.51 5.31 5.31 5.52 5.28 ESEER 7.25 7.30 7.40 7.27 7.52 COP 5.42 5.27 5.28 5.5 5.3 Dimensions Unit Height mm 2,120 2,120 2,120 2,290 2,480 Width mm 1,180 1,180 1,180 1,240 1,340 Depth mm 3,460 3,460 3,460 3,690 3,690 Weight Unit kg 2,892 2,928 2,941 3,451 4,237 Operation weight kg 2,977 3,033 3,053 3,611 4,488 Water heat Type Flooded single pass shell and tube exchanger - Water volume l 88 88 96 134 156 evaporator Water flow rate Cooling Nom. l/s 29.3 33.8 36.3 42.9 49.9 Heating Nom. l/s 29.6 34.2 36.7 43.5 50.4 Water pressure drop Cooling Nom. kpa 80.0 106.0 89.0 98.0 104 Heating Nom. kpa 82 108 90 100 106 Water heat Type Single pass shell and tube exchanger - Water volume l 81 102 102 126 217 condenser Water flow rate Cooling Nom. l/s 34.5 40.2 43.1 50.7 59.4 Heating Nom. l/s 36.46 42.33 45.47 53.38 62.35 Water pressure drop Cooling Nom. kpa 54.0 41.0 46.0 44.0 33.0 Heating Nom. kpa 60 44 51 48 36 Compressor Type Inverter driven single screw compressor Quantity 1 Sound power level Cooling Nom. dba 101 105 105 105 108 Sound pressure level Cooling Nom. dba 82 86 86 86 89 Operation range Evaporator Cooling Min.~Max. CDB -3~20 Condenser Cooling Min.~Max. CDB 16~63 Refrigerant Type / GWP / Circuits R-134a / 1,430 / 1 Refrigerant charge Per circuit kg 100 110 110 170 180 TCO₂eq 143 157 157 243 257 Piping connections Evaporator water inlet/outlet (OD) 141.3 141.3 141.3 168.3 219.1 Condenser water inlet/outlet (OD) 168.3 168.3 168.3 219.1 219.1 Unit Starting current Max. A 179 214 245 295 344 Running current Cooling Nom. A 171 202 220 249 300 Max. A A 256 306 350 421 491 Power supply Phase/Frequency/Voltage Hz/V 3~/50/400 10

High efficiency, standard sound Cooling only/heating only EWWD-VZXS 450 500 610 710 800 900 C11 Cooling capacity Nom. kw 449 501 613 713 793 901 1,053 Heating capacity Nom. kw 553 617.2 756.7 882.2 984.6 1,110 1,302 Power input Cooling Nom. kw 81.1 89.6 108 128 146 158 192 Heating Nom. kw 102 112 138 163 185 199 240 EER 5.53 5.58 5.64 5.54 5.43 5.67 5.46 ESEER 7.51 7.92 8.10 8.20 8.22 7.92 8.17 COP 5.45 5.49 5.48 5.42 5.33 5.58 5.43 Dimensions Unit Height mm 2,090 2,120 2,230 2,290 2,480 Width mm 1,180 1,220 1,240 1,340 Depth mm 3,460 3,690 3,830 Weight Unit kg 2,968 2,911 3,102 3,470 3,451 4,257 4,552 Operation weight kg 3,098 3,006 3,274 3,648 3,611 4,518 4,860 Water heat Type Flooded single pass shell and tube exchanger - Water volume l 70 88 136 134 168 199 evaporator Water flow rate Cooling Nom. l/s 21.6 24.0 29.4 34.2 38.0 43.2 50.4 Heating Nom. l/s 21.7 24.2 29.7 34.5 38.4 43.7 50.9 Water press. drop Cooling Nom. kpa 89.0 63.0 59.0 63.0 55.0 67.0 58.0 Heating Nom. kpa 90 64 60 64 56 68 59 Water heat Type Single pass shell and tube exchanger - Water volume l 81 92 126 145 126 217 241 condenser Water flow rate Cooling Nom. l/s 25.4 28.3 34.7 40.4 45.2 50.9 59.9 Heating Nom. l/s 26.68 29.78 36.53 42.60 47.53 53.59 62.85 Water press. drop Cooling Nom. kpa 31.0 28.0 22.0 20.0 24.0 25.0 25.0 Heating Nom. kpa 34 31 24 22 27 28 27 Compressor Type Inverter driven single screw compressor Quantity 1 Sound power level Cooling Nom. dba 97 99 101 105 108 Sound pressure level Cooling Nom. dba 78 80 82 86 89 Operation range Evaporator Cooling Min.~Max CDB -3~20 Condenser Cooling Min.~Max. CDB 16~65 Refrigerant Type / GWP / Circuits R-134a / 1,430 / 1 Refrigerant charge Per circuit kg 95 100 110 170 180 TCO₂eq 136 143 157 243 257 Piping connections Evaporator water inlet/outlet mm 141.3 168.3 219.1 Condenser water inlet/outlet mm 168.3 219.1 Unit Starting current Max A 155 173 179 214 256 295 344 Running current Cooling Nom. A 126 140 171 201 229 249 299 Max A 222 247 256 306 366 421 491 Power supply Phase/Frequency/Voltage Hz/V 3~/50/400 Premium efficiency, standard sound Cooling only/heating only EWWD-VZPS 505 715 910 Cooling capacity Nom. kw 505 718 908 Heating capacity Nom. kw 619.7 885.3 1,115 Power input Cooling Nom. kw 87.5 126 156 Heating Nom. kw 110 161 196 EER 5.77 5.66 5.81 ESEER 8.15 8.48 8.25 COP 5.62 5.49 5.68 Dimensions Unit Height mm 2,090 2,430 2,480 Width mm 1,180 1,330 1,340 Depth mm 3,690 3,830 Weight Unit kg 3,247 4,082 4,346 Operation weight kg 3,375 4,349 4,660 Water heat Type Flooded single pass shell and tube exchanger - Water volume l 96 168 199 evaporator Water flow rate Cooling. Nom. l/s 24.2 34.4 43.5 Heating Nom. l/s 24.4 34.7 44 Water press. drop Cooling Nom kpa 55.0 42.0 44.0 Heating Nom. kpa 56 43 45 Water heat Type Single pass shell and tube exchanger - Water volume l 126 217 241 condenser Water flow rate Cooling Nom. l/s 28.5 40.6 51.2 Heating Nom. l/s 29.93 42.7 53.83 Water press. drop Cooling Nom. kpa 15 17 19 Heating Nom kpa 17 18 21 Compressor Type Inverter driven single screw compressor Quantity 1 Sound power level Cooling Nom. dba 99 105 Sound pressure level Cooling Nom. dba 80 86 Operation range Evaporator Cooling Min.~Max. CDB -3~20 Condenser Cooling Min.~Max. CDB 16~65 Refrigerant Type / GWP / Circuits R-134a / 1,430 / 1 Refrigerant charge Per circuit kg 100 150 180 TCO₂eq 143 215 257 Piping connections Evaporator water inlet/outlet mm 141.3 219.1 Condenser water inlet/outlet mm 219.1 Unit Starting current Max A 173 214 295 Running current Cooling Nom. A 138 200 247 Max A 247 306 421 Power supply Phase/Frequency/Voltage Hz/V 3~/50/400 11

Why choose Daikin? Daikin is Europe s leading manufacturer and global n 1 of highly energy-efficient heating, cooling, ventilation and refrigeration solutions for residential, commercial and industrial applications. Why choose Daikin chillers? The widest and most flexible chiller portfolio Worldwide experience in chiller design and manufacturing The highest efficiency for every installation Quality and reliability Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 8400 Oostende Belgium www.daikin.eu BE 0412 120 336 RPR Oostende (Responsible Editor) FSC ECPEN17-418 10/16 Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. Printed on non-chlorinated paper. Prepared by La Movida