Efficient, Long Lasting Evaporative Condensers

Similar documents
Reliable products with long-term, low cost of ownership

XLP2 Evaporative Condensers

Evaporative Condensers

CXVB Evaporative Condenser TABLE OF CONTENTS E112 ENGINEERING DATA CXVB EVAPORATIVE CONDENSERS E144 STRUCTURAL SUPPORT CONSTRUCTION DETAILS

Un-Used Series CXV Evaporative Condenser

Product Introduction...E35. Benefits...E37. Construction Details...E39. Custom Features & Options...E41. Accessories...E44. Engineering Data...

Closed Circuit Cooling Towers

Evaporative Condensers

SECTION COOLING TOWERS

Product Introduction...E11. Benefits...E13. Construction Details...E15. Custom Features & Options...E19. Accessories...E23. Structural Support...

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

SECTION COOLING TOWERS

INFO. Stainless Steel Evaporative Cooler. The New Choice In Evaporative Cooling

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

Product Introduction...D85. Benefits...D87. Construction Details...D89. Custom Features & Options...D91. Accessories...D93. Engineering Data...

Closed Circuit Hybrid Cooling Towers. Product Introduction...E61. Benefits...E63. Construction Details...E65. Custom Features & Options...

Compass Series Open Cooling Towers

Product Introduction...D9. Benefits...D11. Construction Details...D13. Custom Features & Options...D15. Accessories...D18. Engineering Data...

Series 1500 Cooling Tower Specification

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Mr. GoodTower Service Center

Product Introduction...D33. Benefits...D35. Construction Details...D37. Custom Features & Options...D39. Accessories...D41. Engineering Data...

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

Improving Condenser Safety In Cold Chain Facilities

Bulletin 241B. Mark owned by the Cooling Technology Institute

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

How about Savings in Time, Money, Energy and Longer Life?

Evaporative Condensers

Available in Capacities from 208 to 2,050 Ammonia Tons!

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

Maximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the.

Closed Circuit Coolers Technology for the Future, Available Today

INFO. Evaporative Condenser Stainless Steel MW. The Best Choice In Evaporative Cooling

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

JCseries EVAPORATIVE CONDENSER. engineering data

IDCF & IDC3 Evaporative Condensers

Aquatower STEEL COOLING TOWER. engineering data and specifications

/ Aquatower Fiberglass Cooling Tower /

BECAUSE TEMPERATURE MATTERS: MAINTAINING COOLING TOWERS

Forced Draft, Axial Fan Models Available in Capacities from 124 to 1,408 Ammonia Tons!

Closed Circuit Cooling Towers

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Bulletin 242-E Metric C E R T I F I E D E N I S O Mark owned by the Cooling Technology Institute

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

QuadraFlow Cooling Tower

C E R T I F I E D E N I S O

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

FRIGID COIL COPPER TUBE EVAPORATIVE CONDENSERS YEC Series

ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER

Bulletin 241-E Metric C E R T I F I E D E N I S O Mr. GoodTower

Since its founding in 1976, EVAPCO,

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

EVAPORATIVE COOLED PACKAGED CHILLERS & CHILLED WATER PLANTS

Vision and Skyline Semi-custom Air Handlers

A. Codes and Standards that are Standard at the University:

ENERGY SAVING, EASY TO INSTALL AND MAINTAIN FORCED DRAFT, AXIAL FAN CONDENSERS

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

ICT Cooling Towers. Stainless Steel Basins and Fiberglass Casings Available. Advanced Features In Induced Draft, Counterflow Towers.

Evaporative Cooling products

What is a Closed circuit Cooling Tower (CCT)?

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Lenntech. Tel Fax

SECTION STEAM CONDENSATE PUMPS

TM Series. Induced Draft, Counter Flow Optional Accessories

ENGINEERING DATA AND SPECIFICATIONS. MH Fluid Cooler

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

MAC N-407 Air-Cooled Chiller

INVITATION TO BID FAILURE TO SIGN WILL DISQUALIFY BID Bid No.: #GK-MECH-YARD ADDENDUM NO. 1

Plenum Fans. Model HPA. Direct Drive

ENGINEERING AND SPECIFICATIONS. Marley MC FLUID COOLER

DIVISION 15 MECHANICAL

MACH N-407 Heat Pump Air-Cooled Chiller

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

STAINLESS STEEL EVAPORATIVE CONDENSER

215 till kw nominal capacity

DESIGN GUIDELINES SECTION HVAC

Industrial Fans & Blowers

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

TECHNICAL. Series 18. Pump Packages

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

ECOSS. Stainless Steel Evaporative Condenser

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

CONTENTS. B. System Design and Performance Requirements

Modular Supply Make-Up Air Unit

RHEEM PACKAGE GAS/ELECTRIC

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Transcription:

CONDENSERS Efficient, Long Lasting Evaporative Condensers Reliable Products With Long-Term, Low Cost of Ownership

CONDENSERS Specifications Standard Unit Construction Corrosion Protection (Coil & Casing) Corrosion Protection (Basin) ECOSS IDCF IDC3 Stainless steel condensing coil Stainless steel framework c l a d w i t h s t a i n l e s s s t e e l p a n e l s Welded stainless steel basin See above See above G-235 (Z700 metric) mill galvanized steel panels and basin. All prime steel condensing coil, hot dip galvanized after fabrication (HDGAF). Stainless steel coil Stainless steel casing Stainless steel coil and casing Stainless steel Triple Guard G-235 (Z700 metric) mill galvanized steel panels and basin. All prime steel condensing coil, hot dip galvanized after fabrication (HDGAF). Stainless steel coil Stainless steel casing Stainless steel coil and casing Stainless steel Triple Guard Coil Test Pressure, psig 494 375 375 Max. Working Pressure, psig 380 300 300 Style Capacity Control Ease of Maintenance Features Access Packages Sound Levels Induced draft with multiple EC fan motors. Onboard motor management controller Factory supplied access platform for top access to fan motors and nozzles. Access to basin through inlet air louvers. Factory supplied access platform for top access to fan motors and nozzles. Access to basin through inlet air louvers. Low sound levels via EC motor technology Induced draft, axial fans with primary surface condensing coil PLUS fill media for enhanced heat rejection & scale reduction. Independent Fan Operation with VFD ready motors. Inward swinging door for access to motor, mist eliminators and spray nozzles. Access to basin through inlet air louvers. Multiple options: Full perimeter handrails Offset platforms Flush platforms Fans located at top of unit directing noise up and away. Induced draft, axial fans with primary surface condensing coil Independent Fan Operation with VFD ready motors. Inward swinging door for access to motor, mist eliminators and spray nozzles. Access to basin through inlet air louvers. Multiple options: Full perimeter handrails Offset platforms Flush platforms Fans located at top of unit directing noise up and away. Motor Design, Pump & Fan Brushless DC totally enclosed motor NEMA AC totally enclosed motors NEMA AC totally enclosed motors Factory Testing Coil shipped charged with air to ensure integrity. Basin water tight tested. Coil shipped charged with air to ensure integrity. Basin water tight tested. Coil shipped charged with air to ensure integrity. Basin water tight tested. Ease of Assembly No butyl tape required, interlocking water-tight field seams. Factory installed blank-off panels on multi-cell installations. Factory provided rigging pins for fast basin to coil rig. Improved base-rail for squareness. Factory installed blank-off panels on multi-cell installations. Factory provided rigging pins for fast basin to coil rig. Improved base-rail for squareness. Factory installed blank-off panels on multi-cell installations.

Specifications XLP2 ECC ECL G-235 (Z700 metric) mill galvanized steel panels and basin. All prime steel condensing coil, hot dip galvanized after fabrication (HDGAF). Stainless steel coil Stainless steel casing Stainless steel coil and casing Stainless steel Triple Guard G-235 (Z700 metric) mill galvanized steel panels and basin. All prime steel condensing coil, hot dip galvanized after fabrication (HDGAF). Stainless steel coil Stainless steel casing Stainless steel coil and casing G-235 (Z700 metric) mill galvanized steel panels and basin. All prime steel condensing coil, hot dip galvanized after fabrication (HDGAF). Stainless steel coil Stainless steel casing Stainless steel coil and casing Standard Unit Construction Corrosion Protection (Coil & Casing) Stainless steel Stainless steel Corrosion Protection (Basin) 375 375 375 Coil Test Pressure, psig 300 300 300 Max. Working Pressure, psig Forced draft, axial fans with primary surface condensing coil. Forced draft, centrifugal fans with primary surface condensing coil. Forced draft, centrifugal fans with primary surface condensing coil, low profile. Style Independent Fan Operation with VFD ready motors. Single drive, VFD ready, motor Single drive, VFD ready, motor Capacity Control Two (2) 30 x 44 Access Doors (one per end) standard to adjust float valve, clean strainer & flush basin. Cold water basin sloped to eliminate water and reduce biological growth. Internal access to adjust float valve, clean strainer & flush basin. Cold water basin sloped to eliminate water and reduce biological growth Internal access to adjust float valve, clean strainer & flush basin. Cold water basin sloped to eliminate water and reduce biological growth Ease of Maintenance Features Multiple options: Full perimeter handrails Offset platforms Flush platforms Multiple options: Full perimeter handrails Offset platforms Flush platforms Multiple options: Full perimeter handrails Offset platforms Flush platforms Access Packages Varying levels due to multiple fans. Low sound centrifugal fan. Low sound centrifugal fan. Sound Levels NEMA AC totally enclosed motors NEMA AC totally enclosed motors NEMA AC totally enclosed motors Motor Design, Pump & Fan Coil shipped charged with air to ensure integrity. Basin water tight tested. Coil shipped charged with air to ensure integrity. Basin water tight tested. Coil shipped charged with air to ensure integrity. Basin water tight tested. Factory Testing Standard Unit. Easy Pan to Coil Section Mounting Standard Unit. Coil and Pan Shipped Assembled, Easy Pan Section Mounting. Containerized version for export shipment Standard Unit. Coil and Pan Shipped Assembled, Easy Pan Section Mounting Ease of Assembly

CONDENSERS ECOSS Stainless Steel Evaporative Condenser Induced draft, stainless steel evaporative condenser with EC motor axial fan assembly is built to withstand the tests of time. ECOSS FEATURES Overview ECOSS stainless steel models are induced draft evaporative condensers with axial fans. A single ECOSS unit has a capacity range of 200-625 ammonia tons, and can be configured in dual or quad arrangements. Units have exceptional resistance to white rust and corrosive elements. With reduced annual operating costs and an effective life span that is double that of conventional evaporative condensers, ECOSS can deliver up to 70% savings in total life-cycle costs. Standard Features Induced draft Electronically commutated (EC) motors with built-in variable fan speed control (no VFD required) Efficient direct drive axial fans 304L stainless steel coil (316L SS first pass) frame and basin Modular frame design Motor control panel Hinged fan panels Standard Available Options Basin heaters Electric water level control Remote sump Unit Specific Options 5-year warranty Coil, powertrain, basin corrosion protection system UV resistant, corrosion resistant, inlet louvers Access package: Ladder with safety cage, external walkway and perimeter railing Motor davit(s) Internal walkway High static stability and 50% less* operating weight Factory on-site support for rigging and startup ASME U stamp 316L stainless steel construction Pre-assembled platform (Top-access) Wiring to terminal box * 50% lighter construction when compared to an equivalent G-235 galvanized condenser ECOSS BENEFITS Low Operating Cost Energy Savings via: Direct drive fans Avoids the power losses of belt drive EC fan motors with built-in variable speed control No additional power losses compared to a NEMA motor with VFD. No resonance speeds to avoid. Low scaling propensity of stainless steel minimizes heat transfer penalties. Water Savings Operation at higher cycles of concentration minimizes blowdown, make-up water requirements, chemical treatments and environmental impact. Lower Maintenance Cost No Routine Passivation Stainless steel is self-passivating, therefore reducing labor, water treatment requirements, and environmental impact associated with galvanized steel construction. Direct Drive Fans eliminate a number of routine maintenance requirements associated with belt drive systems: NO belt adjustments or belt replacements NO greasing of bearings or replacement of bearings NO belt sheaves to align or replace NO replacement of drive shafts Lower Installed Cost Lower Weight - 304L stainless steel construction weighs 50% less than G-235 galvanized, requiring less support structure and a smaller crane to assemble. Building block seam connection - Of the upper and lower coil-fan/basin sections eliminates the use of drift pins, sealer tape, screw tappers, chain come-alongs and associated labor for field assembly. Fan Wiring - Direct drive fans are wired to a common power terminal junction box, reducing associated field wiring. Motor Management Controller - Control fan speed and system setpoint, eliminating material and labor costs associated with VFDs.

ECOSS BENEFITS (Cont.) Long Service Life Self-Passivating Stainless Steel provides a minimum product life of two times that of G-235. Welded Stainless Steel Basin - All factory seams in the basin are fully welded to ensure watertight assembly and are fully warranted against leaks. ASME Certified Serpentine Coil - Constructed and fabricated with ANSI rated materials, in compliance with ASME Section VIII, BPV Code. Fabrication to this stringent standard translates into higher reliability overall. EC Fan 10+ Year MTBF - With a stainless steel shaft and bearings and an epoxy coated body, this design provides variable speed operation, soft start, and low motor heat, with a Mean Time Between Failures of 10 or more years. ECOSS CONSTRUCTION DETAILS Heavy Duty Construction Full 304L stainless steel construction Water Distribution System Schedule 40 PVC spray branches Large orifice, low pressure, clog-resistant nozzles Branch piping is removable for easier maintenance Close-coupled, bronze impeller, fitted centrifugal recirculating spray pump Totally enclosed fan cooled (TEFC) spray pump motor Stainless steel strainer Coil Fully welded 304L stainless steel tubing Pressure tested under water to 494 psig Sloped tubes for free drainage of fluid ASME code compliant A CRN is available upon request for orders shipping into Canada Drift Eliminators Polyvinyl chloride (PVC) Impervious to rot, decay, and biological attack Removable for nozzle access Direct Drive, Axial Fan System Motor Management Controller for controlling fan speed and system setpoint (pressure or temperature) Electronically commutated (EC) motors F4-2 motor moisture protection; corrosion resistant Energy efficient and quiet operation Easy Access Internal walkway beneath the fan panels Hinged fan panels provide quick access to drift eliminators and spray nozzles Vertical alignment of inlet louvers for easy basin access

CONDENSERS IDCF Induced Draft Evaporative Condenser The IDCF is a counterflow, induced draft, axial fan evaporative condenser with patented coil/fill technology. IDCF FEATURES Overview IDCF models are the only counterflow, induced draft evaporative condensers with axial fans which use a patterned coil/ fill technology to maximize heat rejection. Incorporating the same robust construction and features found in the IDC3, the use of a secondary heat transfer media in the IDCF delivers less energy consumption, reduced refrigerant charge, significant (50%) coil scale reduction and hence better retain the original unit thermal performance, lighter unit weight, when compared to all the other traditional coil only evaporative condensers on the market. The IDCF has a capacity range of 45 2810 ammonia tons in a single unit. Standard Features Robust Structure - Frame around the coil casing NEW! Assures squareness during shipping and rigging, and eliminates the need for a shipping skid. Rigging pins NEW! Align coil casing and basin in less than 15 minutes Blank-off panels (Multi-cell) NEW! PVC fill bundles providing secondary heat rejection NEW! Induced draft Premium efficient VFD Axial fan motors HDGAF coil assembly International Building Removable louvers Code (IBC) compliant Independent drive system Standard Available Options Basin sweeper system Basin heaters Electric water level control Remote sump 304 stainless steel coil ASME U stamp Equipment starters and controls Coil circuiting TripleGuard 5-year warranty basin corrosion protection system Unit Specific Options Wiring to terminal box Heavy gauge coil Extended surface coil Stainless steel construction with welded basin Vibration cutout switch Pre-assembled external platforms, ladder & safety cages Variety of access options meeting OSHA requirements Structure Upgrade: Certified to withstand up to an S DS of 3.75g and wind loads up to 200 psf Redundant fan option on 12 x18 units IDCF BENEFITS Low Energy Consumption Minimizes the energy consumption of the entire system. Owners save money while conserving natural resources and reducing environmental impact. High efficiency, low energy axial fans Premium, efficient, VFD duty-ready motors Efficient fan drive system (Independent direct-drive or belt drive) Easy Maintenance Water Distribution Branch removal system requires no tools. Hygienic Cold Water Basin Sloped toward pump suction to eliminate stagnant water and reduce biological growth. Additionally, the suction strainer with removable antivortex hood is easily accessible from the louver face to simplify maintenance. Mechanical Section Fan motors are easily accessed via inward swinging doors. Easy bearing lubrication due to externally mounted lube line access points. Lower Installed Cost Significantly reduced rigging time through the use of factory supplied rigging pins and robust structural frame ensuring squareness. Pre-assembled IBC and OSHA approved platform packages reduce installation time (optional). Long Service Life Superior corrosion protection through the use of optional TripleGuard protection or construction materials such as stainless steel. Bearings Minimum L 10 bearing life of 100,000 hours delivers years of trouble free service.

Maximizes thermal efficiency, reduces coil scale and refrigerant charge, while incorporating the same robust construction and features found in the IDC3. IDCF CONSTRUCTION DETAILS Heavy Duty Construction G-235 (Z700 metric) mill galvanized steel panels Robust structural frame ensures squareness Water Distribution System Schedule 40 PVC spray branches Large orifice, 360 nonclog spray nozzles Toolless removal of spray branches Nozzles in spray branches use grommet design, snapping in/out for easy maintenance Interstitial Coil/Fill Continuous serpentine, steel tubing Hot-dip galvanized after fabrication (HDGAF) Max. allowable working pressure is 300 psig Sloped tubes for free drainage of fluid Fabricated per ASME B31.5 standards Orders shipping into Canada are supplied with a CRN (Canadian Registration Number) High efficiency, non-clog polyvinyl chloride (PVC) fill Fill enhances heat transfer, reducing scale in the coil section to enhance coil life and better retain unit thermal performance Drift Eliminators Polyvinyl chloride (PVC) Impervious to rot, decay, and biological attack Flame spread rating of 5 per ASTM E84 Assembled in easy to handle sections Fan Drive System Premium quality, solid-backed, multigroove belt Heavy-duty bearings L 10 100,000 hours Extended lubrication lines Premium efficiency/vfd duty fan motors are standard 5-year motor and drive warranty Low Horsepower Axial Fan(s) Corrosion resistant aluminum for high efficiency, quiet operation Recirculating Spray Pump Close-coupled, bronze impeller, fitted centrifugal pump Totally enclosed fan cooled (TEFC) motor Bleed line with metering valve installed from pump discharge to overflow Basin Suction strainer with removable anti-vortex hood accessible from the louver face Sloped for easy cleaning Rigging pins to simplify alignment Access Basin access is made simple through easily removed louver sections. Inward swinging door(s) allow easy access to water distribution and mechanical (fan-motor) components.

CONDENSERS IDC3 Induced Draft Evaporative Condenser The IDC3 induced draft, axial fan, evaporative condenser improves on the successful previous generation the IDC2. IDC3 FEATURES Overview By incorporating new features designed to reduce installation time, the IDC3 induced draft, axial fan, evaporative condenser delivers savings to both owners and contractors and is the ideal choice for new or replacement projects. The IDC3 has a capacity range of 41-2,734 ammonia tons in a single unit. Standard Features Robust Structure - Frame around the coil casing NEW! Assures squareness during shipping and rigging, and eliminates the need for a shipping skid. Rigging pins NEW! Align coil casing and basin in less than 15 minutes Blank-off panels (Multi-cell) NEW! Hot-dip galvanized after fabrication (HDGAF) coil assembly in accordance to ASME B31.5 standards Independent direct-drive motors (4 x6 & 4 x12 units only) Optimized water distribution system reduces pump horsepower by up to 60% Induced draft Axial fan Premium efficiency VFDduty motors Standard Available Options Basin sweeper system Basin heaters Electric water level control Remote sump 304 stainless steel coil ASME U stamp Equipment starters and controls Coil circuiting TripleGuard 5-year warranty basin corrosion protection system Unit Specific Options Wiring to terminal box Heavy gauge coil Extended surface coil Meets wind and seismic requirements of the International Building Code Removable louvers Stainless steel construction with welded basin Vibration cutout switch Pre-assembled external platforms, ladder & safety cages Variety of access options meeting OSHA requirements Structure Upgrade: Certified to withstand up to an S DS of 3.10g and wind loads up to 140 psf Redundant fan option on 12 x18 units IDC3 BENEFITS Low Energy Consumption Minimizes the energy consumption of the entire system. Owners save money while conserving natural resources and reducing environmental impact. High efficiency, low energy axial fans Premium, efficient, VFD duty-ready motors Efficient fan drive system (Independent direct-drive or belt drive) Easy Maintenance Water Distribution Branch removal system requires no tools. Hygienic Cold Water Basin Sloped toward pump suction to eliminate stagnant water and reduce biological growth. Additionally, the suction strainer with removable antivortex hood is easily accessible from the louver face to simplify maintenance. Mechanical Section Fan motors are easily accessed via inward swinging doors. Easy bearing lubrication due to externally mounted lube line access points. Lower Installed Cost Significantly reduced rigging time through the use of factory supplied rigging pins and robust structural frame ensuring squareness. Pre-assembled IBC and OSHA approved platform packages reduce installation time (optional). Long Service Life Superior corrosion protection through the use of optional TripleGuard protection or construction materials such as stainless steel. Bearings Minimum L 10 bearing life of 100,000 hours delivers years of trouble free service.

IDC3 CONSTRUCTION DETAILS Heavy Duty Construction G-235 (Z700 metric) mill galvanized steel panels Robust structural frame ensures squareness Water Distribution System Schedule 40 PVC spray branches Large orifice, 360 nonclog spray nozzles Toolless removal of spray branches Nozzles in spray branches use grommet design, snapping in/out for easy maintenance Interstitial Coil Continuous serpentine, steel tubing Hot-dip galvanized after fabrication (HDGAF) Max. allowable working pressure is 300 psig Sloped tubes for free drainage of fluid Fabricated per ASME B31.5 standards Orders shipping into Canada are supplied with a CRN Drift Eliminators Polyvinyl chloride (PVC) Impervious to rot, decay, and biological attack Flame spread rating of 5 per ASTM E84 Assembled in easy to handle sections Fan Drive System Premium quality, solid-backed, multigroove belt Heavy-duty bearings L 10 100,000 hours Extended lubrication lines Premium efficiency/vfd duty fan motors are standard 5-year motor and drive warranty Low Horsepower Axial Fan(s) Corrosion resistant aluminum for high efficiency, quiet operation Recirculating Spray Pump Close-coupled, bronze impeller, fitted centrifugal pump Totally enclosed fan cooled (TEFC) motor Bleed line with metering valve installed from pump discharge to overflow Basin Suction strainer with removable anti-vortex hood accessible from the louver face Sloped for easy cleaning Rigging pins to simplify alignment Access Basin access is made simple through easily removed louver sections. Inward swinging door(s) allow easy access to water distribution and mechanical (fan-motor) components.

CONDENSERS XLP2 Forced Draft Evaporative Condenser Forced draft evaporative condenser with axial fans designed for energy efficiency, reliability, maintainability, and easy field assembly. XLP2 FEATURES Overview XLP2 models are forced draft evaporative condensers with axial fans to minimize energy consumption. Units are designed to address the energy efficiency, reliability, maintainability, and field assembly needs of the market. These benefits provide the end user with long service life, and ease of installation and commissioning for the contractor. The XLP2 has a capacity range of 87-1,443 ammonia tons in a single unit. Standard Features Forced draft Corrosion resistant axial fan Hot-dip galvanized after fabrication (HDGAF) coil assembly in accordance to ASME B31.5 standards Full-size hinged access doors Premium efficiency VFD-duty motors Independent fan drives provide redundancy and options for capacity control International Building Code (IBC) compliant; shake table tested up to S DS of 1.60g Superior corrosion protection Mechanical water level control Easy assembly Standard Available Options Basin sweeper system Basin heaters Electric water level control Redundant pumps Remote sump 304 stainless steel coil ASME U stamp Coil circuiting Vibration cutout switch Equipment starters and controls Unit Specific Options Wiring to terminal box Subcooling coil Extended surface coil Pre-assembled external platforms, ladder & safety cages TripleGuard 5-year warranty basin corrosion protection system Stainless steel construction with welded basin Variety of access options meeting OSHA requirements XLP2 BENEFITS Low Energy Consumption High efficiency, low horsepower axial fans Premium efficiency VFD-duty motors (Standard) Variable Frequency Drives (Optional) Multiple fan models allow for capacity staging Easy Maintenance Access Doors Two 30 x 44 access doors are standard on side blow units and one on end blow units. This allows the interior of the unit to be easily accessed for adjusting the float valve, cleaning the strainer or flushing the basin. A large hinged internal partition door and an external door step are standard on all units. Hygienic Cold Water Basin The cold water basin is sloped toward the pump suction to eliminate stagnant water zones and reduce biological growth. Additionally, the suction strainer is easily removed to simplify maintenance. Entire drive system is located outside of the discharge air stream, at the base of the unit for easy, unrestricted access to the motors, bearings, and fans. This also protects the drive system from moisture, condensation and icing.

XLP2 CONSTRUCTION DETAILS Heavy Duty Construction G-235 (Z700 metric) mill galvanized steel panels Water Distribution System Schedule 40 PVC spray branches Large orifice, 360 nonclog spray nozzles Nozzles in spray branches use grommet design, snapping in/out for easy maintenance Coil Continuous serpentine, steel tubing Hot-dip galvanized after fabrication (HDGAF) Max. allowable working pressure is 300 psig Sloped tubes for free drainage of fluid Fabricated per ASME B31.5 standards Orders shipping into Canada are supplied with a CRN Drift Eliminators Recyclable polyvinyl chloride (PVC) Impervious to rot, decay, and biological attack Flame spread rating of 5 per ASTM E84 Assembled in easy to handle sections Independent Fan Drive System Premium quality, solid-backed, multigroove belt Heavy-duty bearings L 10 94,000 hours Extended lubrication lines Premium efficiency/vfd duty fan motors are standard 5-year motor and drive warranty Low Horsepower Axial Fan(s) Corrosion resistant Recirculating Spray Pump Close-coupled, bronze impeller, fitted centrifugal pump Totally enclosed fan cooled (TEFC) motor Bleed line with metering valve installed from pump discharge to overflow Access Door Interior of unit is easily accessible: Two 30 x 44 access doors Standard on side blow units One 30 x 44 access door Standard on end blow units Strainer Anti-vortexing design to prevent air entrainment

CONDENSERS ECC Centrifugal Evaporative Condenser Forced draft evaporative condenser with centrifugal fans designed for both indoor or outdoor applications where external ductwork or other sources of static pressure exist. ECC FEATURES Overview ECC models are evaporative condensers with centrifugal fans and are suited to applications where external ductwork or other sources of external static pressure exist. The ECC has a capacity range of 7-1,140 ammonia tons in a single unit. Standard Features Forced draft Low sound centrifugal fan Hot-dip galvanized after fabrication (HDGAF) coil assembly in accordance to ASME B31.5 standards Premium efficiency VFD-duty motors Indoor or outdoor applications Standard Available Options Basin sweeper system Basin heaters Electric water level controls Redundant pump Remote sump 304 stainless steel coil TripleGuard 5-year warranty basin corrosion protection system ASME U stamp Equipment starters and controls Coil circuiting Stainless steel construction with welded basin Vibration cutout switch ECC BENEFITS Low Energy Consumption Premium efficiency VFD-duty motors (Standard) Variable Frequency Drives (Optional) Easy Maintenance 360 spray nozzles are non-clogging, reducing maintenance costs, and ensuring efficient equipment operation All moving parts are located near the base of the unit, within easy reach for cleaning, lubrication, or adjustments Fans, motors, and drive system are located outside of the moist discharge airstream, protecting them from moisture, condensation and icing. Quiet Operation Centrifugal fans have inherently low sound characteristics Factory designed sound attenuation is available for both the air intake and discharge Particularly sound sensitive areas can be accommodated by facing the blankoff panel to the sound sensitive direction Unit Specific Options Wiring to terminal box Heavy gauge coil Extended surface coil Desuperheating coil Subcooling coil Air intake and discharge sound attenuation

ECC CONSTRUCTION DETAILS Heavy Duty Construction G-235 (Z700 metric) mill galvanized steel panels Water Distribution System Schedule 40 PVC spray branches Large orifice, 360 nonclog spray nozzles Nozzles in spray branches use grommet design, snapping in/out for easy maintenance Coil Continuous serpentine, steel tubing Hot-dip galvanized after fabrication (HDGAF) Max. allowable working pressure is 300 psig Sloped tubes for free drainage of fluid Fabricated per ASME B31.5 standards Orders shipping into Canada are supplied with a CRN Drift Eliminators Recyclable polyvinyl chloride (PVC) Impervious to rot, decay, and biological attack Flame spread rating of 5 per ASTM E84 Assembled in easy to handle sections Fan Drive System V-belt drive Heavy-duty bearings L 10 40,000 hours Premium efficiency VFD duty fan motors are standard 5-year motor and drive warranty Low Sound Centrifugal Fan(s) Quiet operation Overcome static pressure Recirculating Spray Pump Close-coupled, bronze impeller, fitted centrifugal pump Totally Enclosed Fan Cooled (TEFC) motor Bleed line with metering valve installed from pump discharge to overflow Strainer Anti-vortexing design to prevent air entrainment Access Door Round access door(s) allow for easy service of the strainer and water makeup assembly.

CONDENSERS ECL Low Profile Centrifugal Evaporative Condenser Forced draft evaporative condenser with centrifugal fan(s) designed for low profile to fit into mechanical room with low ceilings or are easily hidden outdoors. ECL FEATURES Overview ECL models are centrifugal fan evaporative condensers that are specifically designed with a low profile. These units fit well into mechanical equipment rooms with low ceilings and are easily hidden behind louvered walls on buildings. Low profile models are available in heights from 5 2¼ to 8 4¾. The ECL has a capacity range of 11-210 ammonia tons in a single unit. Standard Features Forced draft Low sound centrifugal fan Hot-dip galvanized after fabrication (HDGAF) coil assembly in accordance to ASME B31.5 standards Premium efficiency VFD-duty motors Indoor or outdoor applications Standard Available Options Basin sweeper system Basin heaters Electric water level controls Redundant pump Remote sump 304 stainless steel coil TripleGuard 5-year warranty basin corrosion protection system ASME U stamp Equipment starters and controls Coil circuiting Stainless steel construction with welded basin Vibration cutout switch ECL BENEFITS Low Energy Consumption Premium efficiency VFD-duty motors (Standard) Variable Frequency Drives (Optional) Easy Maintenance 360 spray nozzles are non-clogging, reducing maintenance costs, and ensuring efficient equipment operation All moving parts are located near the base of the unit, within easy reach for cleaning, lubrication, or adjustments Fans, motors, and drive system are located outside of the moist discharge airstream, protecting them from moisture, condensation and icing. Quiet Operation Centrifugal fans have inherently low sound characteristics Factory designed sound attenuation is available for both the air intake and discharge Particularly sound sensitive areas can be accommodated by facing the blankoff panel to the sound sensitive direction Flexible Installation Low profile design fits well into mechanical equipment rooms with low ceilings and are easily hidden behind louvered walls on buildings Ships completely assembled Unit Specific Options Wiring to terminal box Heavy gauge coil Extended surface coil Desuperheating coil Subcooling coil Air intake and discharge sound attenuation

ECL CONSTRUCTION DETAILS Heavy Duty Construction G-235 (Z700 metric) mill galvanized steel panels Water Distribution System Schedule 40 PVC spray branches Large orifice, 360 nonclog spray nozzles Nozzles in spray branches use grommet design, snapping in/out for easy maintenance Coil Continuous serpentine, steel tubing Hot-dip galvanized after fabrication (HDGAF) Max. allowable working pressure is 300 psig Sloped tubes for free drainage of fluid Fabricated per ASME B31.5 standards Orders shipping into Canada are supplied with a CRN Drift Eliminators Recyclable polyvinyl chloride (PVC) Impervious to rot, decay, and biological attack Flame spread rating of 5 per ASTM E84 Assembled in easy to handle sections Fan Drive System V-belt drive Heavy-duty bearings L 10 40,000 hours Premium efficiency VFD duty fan motors are standard 5-year motor and drive warranty Low Sound Centrifugal Fan(s) Quiet operation Overcome static pressure Recirculating Spray Pump Close-coupled, bronze impeller, fitted centrifugal pump Totally Enclosed Fan Cooled (TEFC) motor Bleed line with metering valve installed from pump discharge to overflow Strainer Anti-vortexing design to prevent air entrainment Access Door Round access door(s) allow for easy service of the strainer and water makeup assembly.

Evaporative Condenser Models Frick Evaporative Condensers for Industrial Refrigeration. Manufacturing a broad product line to ensure your project needs are met. Designed to Meet Your Application Needs Evaporative condensers are used to provide lower condensing temperatures and compressor horsepower savings of up to 15 percent when compared with traditional systems. They provide heat rejection for many types of systems, and the specific application will largely determine which Frick Evaporative Condenser is best suited for a project. The information contained within this brochure is geared towards the use of evaporative condensers in the industrial refrigeration market. For technical support with a refrigeration application, contact your local Frick Sales Representative. ECOSS Induced Draft, Stainless Steel The full 304L stainless steel construction is self-passivating. Equipped with direct drive EC fans, ECOSS units lower operating and maintenance costs, and increase the overall life of the product. XLP2 Forced Draft A traditional forced draft evaporative condenser with axial fans. Designed for energy efficiency, reliability, maintainability, and easy field assembly. IDCF Induced Draft Incorporating the same robust construction as the IDC3, the IDCF utilizes a secondary heat transfer media to reduce weight and horsepower required. ECC Forced Draft, Centrifugal Traditional forced draft evaporative condenser with centrifugal blowers. Designed for applications where external ductwork or other sources of static pressure exist. IDC3 Induced Draft This durable and easy-to-install condenser is a counterflow, induced draft, axial fan unit. The heavy-duty construction is resilient, and designed to meet IBC wind and seismic requirements. ECL Forced Draft, Low Profile Centrifugal Traditional forced draft evaporative condenser with centrifugal blower. The low-profile design fits into mechanical rooms with low ceilings or it can be hidden more easily outdoors. Form 140.000-SG1 (2016-09) Supersedes: 140.000-SG1 (2009-10) Subject to change without notice Printed in USA 09/16 PDF 2016 Johnson Controls, Inc. ALL RIGHTS RESERVED JOHNSON CONTROLS 100 CV Avenue Waynesboro, PA 17268 USA Phone: 717-762-2121 Fax: 717-762-8624 www.johnsoncontrols.com/frick