SOLAR HEATING AND COOLING FOR THE SOLAR CITY GLEISDORF

Similar documents
New Steps towards Compact Solar Combisystems in Scandinavia

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

SOLAR COOLING TECHNOLOGIES

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

QUANTUM 340 LITRE TITAN HEAT PUMP WATER HEATERS AND THE APPLICATIONS

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

PERFORMANCE MONITORING OF A HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMP WITH INJECTION CYCLE INSTALLED IN A LOW-INSULATED SINGLE-FAMILY HOUSE IN BELGIUM

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

The Ed Roberts Campus Berkeley, CA

Solar Air-Conditioning and Refrigeration - Introduction

Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb

2 Technical overview of active techniques

K.F. Fong *, C.K. Lee, T.T. Chow

Recent Advances in Energy, Environment and Economic Development

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Solar Heating and Cooling Systems

Performance evaluation of a liquid desiccant solar air conditioning system

DESIGN AND SIMULATION OF A SOLAR ASSISTED DESICCANT-BASED AIR HANDLING UNIT

Preliminary Findings on the Performance of a New Residential Solar Desiccant Air-Conditioner

Potential and Simulation of Open-Cycle Solar-Assisted Climatisation-Plants in Single-Family-Houses

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

Performance of Solar Water Heating Systems in the United States

Performance of non-cfc refrigerator driven by chilled water from 35 kw LiBr/H2O solar absorption cooling system

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Des Places Residence Hall

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

EXHAUST AIR HEAT PUMPS EVALUATED FOR NORDIC CIRCUMSTANCES

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Analysis of System Reports of Task 26 for Sensitivity of Parameters

Draft COMMUNICATION FROM THE COMMISSION

Appendix 8: Generic System #15: Two Stratifiers in a Space Heating Storage Tank with an External Load-Side Heat Exchanger for DHW

Solar Liquid Desiccant Air- Conditioning

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

PASSIVE HEAT EXCHANGER ANTI-FOULING FOR SOLAR DHW SYSTEMS

Experimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump

Technical Data Sheet

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Desiccant Cooling with Solar Energy

Development of a Sorption Assisted Air Conditioning System Driven by a Solar Air Collector

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.

Air-conditioning and climate-control technology

Effects of Latent/Sensible Heat Separation Air-Conditioning and Natural Ventilation on Indoor Thermal Environment in Environment-Friendly Office

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

CHP INTEGRATION (OR IES): MAXIMIZING THE EFFICIENCY OF DISTRIBUTED GENERATION WITH WASTE HEAT RECOVERY

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

nzeb office building

Temperature. In the HVAC area, we talk about two kinds of temperatures.

SIMULATION STUDY ON A NET-ZERO ENERGY HOUSE WITH SOLAR AIR COLLECTORS

Thermal Environment in a Space with Capillary Mats Large-Area Cooling and Heating

SOLAR COMBISYSTEMS IN DENMARK - THE MOST COMMON SYSTEM DESIGNS

Systems engineering Slide 1

SOLAR THERMAL HEATING: ALIVE AND WELL

Adsorption Chillers Energysmart Green Cooling

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016

Experimental Efficiency Investigation on Heat Recovery System Used in a Solar-Powered Desalination Process

Available online at ScienceDirect. Energy Procedia 70 (2015 ) Yanjun Dai*, Xian Li, Ruzhu Wang

Design and Optimization of Domestic Solar Dryer

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Storing excess daytime solar energy to heat greenhouse at night!

Desiccant Evaporative Cooling

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

ClimateWell package solution description

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Heating with facade integrated heat pumps results of the Austrian project SaLüH!

System Using Exhaust Heat from Residential GHPs

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

ERGON EQUIPMENT SA PRESENTATION

A study of radiant cooling for a room with daytime application in tropical climate

Experimental Study and Analysis of Flat Plate Solar Water Heater with Different Flow Rates using of Circulating Pump

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

Available online Journal of Scientific and Engineering Research, 2017, 4(12): Research Article

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

ENERGY EFFICIENCY BRIEF REPORT

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Solar water heaters proposed for the British University in Egypt Bathrooms VS. Traditional electrical water

ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN

Energy Efficiency Potential of Heat Pump Water Heaters in Commercial Buildings

Storage and hot and cold water in a thermocline for Space heating/cooling and domestic hot water

MINIMISING THE RISK OF WATER HAMMER AND OTHER PROBLEMS AT THE BEGINNING OF STAGNATION OF SOLAR THERMAL PLANTS- A THEORETICAL APPROACH

Binoe E. ABUAN, Menandro S. BERANA, Ruben A. BONGAT. University of the Philippines Diliman, Quezon City, Philippines

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Transcription:

JOURNAL OF SUSTENABLE ENERGY, VOL. 1, NO. 2, JUNE, 21 SOLAR HEATING AND COOLING FOR THE SOLAR CITY GLEISDORF THÜR A., VUKITS M. AEE Institute for Sustainable Technologies - AEE INTEC; Feldgasse 19, A-82 Gleisdorf, Austria; email: a.thuer@aee.at Abstract: The Solar City Gleisdorf decided to realize an innovative energy concept when renovating the old town hall and building a new Service Centre. In co-operation with the EU project HighCombi a system for Solar Heating and Cooling was designed and finally constructed in 28. In the new built Service Centre the technical room is situated to supply both buildings with domestic hot water, space heating energy and cold water for cooling. Cold water is produced by an absorption chiller which is powered by a solar thermal collector and a natural gas boiler. Additionally the new built Service Centre is equipped with a Desiccant Evaporative Cooling (DEC) system in combination with the air ventilation system. The main key figures of the solar heating and cooling system are: Collector area: 34 m 2 (new developed high temperature collectors) Heat store: 46 Litre Absorption chiller: 35 kw DEC - Air flow rate: 625 m 3 /h; ca. 35 kw nominal cooling power A detailed monitoring concept is integrated into the controller which allows to evaluate all heat flows, electricity flows, water consumption and of course all temperatures and relative humidity in the system and the building. First year of monitoring shows good results of the solar heating part with electrical SPF el (seasonal performance factor) of up to 82 kwh therm /kwh el, heat losses of the heat store between 4 and 25% and acceptable results of the single components like the absorption chiller and the DEC system during steady state conditions. Quite big potentials for improvements exist in optimizing the overall control strategy of the building in cooperation with the heat/cold delivery system and reduction of parasitic electricity consumption, especially for water treatment. Keywords: Solar Cooling, Solar Heating, Absorption Chiller, DEC System 1. INTRODUCTION The Solar City Gleisdorf decided to renovate the old Town hall and to build a new Service Centre (Fig. ) as a light house project demonstrating the implementation of renewable energy sources by means of solar thermal driven heating and cooling technologies. This project finally was realized as part of the EC project HighCombi. Both buildings are supplied with heat and cold for space heating, domestic hot water and cooling from a central technical room placed in the ground floor of the Service Centre. Additionally a Desiccant Evaporative Cooling (DEC) system in combination with the air ventilation system was installed for the Service Centre. In fig.2 the energy concept is shown. Fig. 1. Photo and section drawing of the old renovated Town Hall and the new built Service Centre I.S.S.N. 267-5538 21 JSE

JOURNAL OF SUSTENABLE ENERGY, VOL. 1, NO. 2, JUNE, 21 SOLAR Heating 34 m² 2 kw, 8-95 C Hot Tank, 46 l 29/35 C, 1 kw Wet Cooling Tower Cold Tank, 8 C; 1 l Natural Gas District Heating 9 C, 5 kw 35 kw 8/12 C 8/12 C Fan Coils Old Town Hall 38 kw ABSORPTION CHILLER (ABC) 1x WFC1, 35 kw 65 kw/85 C Ceiling Cooling/Heating 16/19 C, 35 kw Service Centre Humidifier Ambient Air 32 C/12 g/kg 26 C, 12 g/kg 18 C/ 11g/kg Service Centre DESICCANT EVAPORATIVE COOLING 625 m³/h (35kW) Fig. 2. Energy flow scheme of the entire system Table 1. Key data of this project: Town Hall: Service Centre: Space: 1.321 m 2 1.212 m 2 Volume: 4.599 m 3 3.562 m 3 Persons: ca. 25 ca. 25 Heating load: 94 kw 31 kw Heating demand: 19. kwh/a 33. kwh/a Cooling load: 38 kw 24 kw Cooling demand: 29. kwh/a 42. kwh/a Air ventilation: windows air handling unit (heat recovery=8%) Table 2. Main components are dimensioned as following: Collector area: 34 m 2 (gross collector area) Stores: 46 Litre (hot) and 1 Litre (cold) Absorption chiller: 35 kw nominal cooling power (Yazaki WFC-SC1) Cooling tower: Baltimore FXT 27, wet cooling tower; 1 kw nominal power Air flow rate: 625 m 3 /h; ca. 35 kw nominal cooling power The collectors installed on the roof of the Service Centre are 134 m 2 (Tilt angle: 2, Azimuth: 3 W) of special high temperature flat plate collectors with integrated teflon foils. The remaining collectors were installed in August 29 on extra designed Solar Trees (Tilt angle: 3, Azimuth: 3 E), see fig.3. Due to the different orientation (3 E and 3 W) solar energy can be gained more equal during the day and in combination with an advanced control concept the quite small hot storage tank (4.6 m 3 ) hopefully will not be overheated. The entire project (except the solar trees) was set in operation in July 28. During summer 28 the control system was adapted and the monitoring equipment was installed. Since October 28 monitoring data are available, even though it was necessary to adapt and finetune the monitoring equipment until end of the year 28. I.S.S.N. 267-5538 21 JSE

JOURNAL OF SUSTENABLE ENERGY, VOL. 1, NO. 2, JUNE, 21 Fig. 3. The entire project with solar thermal collectors mounted on solar trees in front of the service center facing east and solar thermal collectors mounted on the roof facing west 2. SOLAR HEATING SYSTEM The first part of the solar heating system with the special high temperature collectors could be evaluated during winter and summer operation as well. In fig.2 a typical winter day (February 2 nd, 29) is shown. At 13:2 solar irradiation was about 69 W/m 2, ambient temperature was 9 C, average collector temperature was 62 C (11 K temperature difference between flow (T_Solar_primär_VL) and return (T_Solar_primär_RL) flow) and the measured power was 47 kw (at secondary side in the water circuit). This results in an efficiency of about 53% of the complete solar thermal primary loop including all pipe losses and heat exchanger losses. According to the data sheet the collector efficiency itself at this operating point is 58%. Solaranlage 8 T_Puffer_oben T_Puffer T_Puffer_unten T_Solar_sek_VL T_Solar_sek_RL T_Kollektor_Solarbäume T_Kollektor_Dach T_Solar_primär_VL T_Solar_primär_RL p_solar_primär P_EL_Solar P_Solar_sek 8 7 6 7 6 Temperatur [ C] 5 4 3 2 5 4 3 2 Leistung [W] 1 1 11.2.9 : 11.2.9 2:24 11.2.9 4:48 11.2.9 7:12 11.2.9 9:36 11.2.9 12: 11.2.9 14:24 11.2.9 16:48 11.2.9 19:12 11.2.9 21:36 12.2.9 : Fig. 4. Temperature and heat capacity (P_Solar_sek) of the solar thermal system on Feb 11th, 29 In fig.5 an operating point on June 19th, 29 at 13: (maximum irradiation) is evaluated. Solar irradiation was 95 W/m 2, ambient temperature was 32 C, average collector temperature was 8 C (15 K temperature difference between flow (T_Solar_primär_VL) and return (T_Solar_primär_RL) flow) and the measured power was 72 kw (at secondary side in the water circuit). This results in an efficiency of about 59% of the complete solar thermal primary loop including all pipe losses and heat exchanger losses. According to the data sheet the collector efficiency itself at this operating point is 65%. For the electrical SPF el of the solar circuit including the 2 pumps during the months October 28 until September 29 monthly values of 56, 36, 25, 29, 52, 62, 63, 71, 74, 82, 76 and 74 kwh th /kwh el and for the full year 67 were measured. The efficiency of the heat store within the same period was calculated based on the energy balance and resulted in monthly values between 75% and 96%, in average 91% for the full 12 month period. I.S.S.N. 267-5538 21 JSE

JOURNAL OF SUSTENABLE ENERGY, VOL. 1, NO. 2, JUNE, 21 solar thermal system Temperature [ C] 1 9 8 7 6 5 4 3 2 1 T_Puffer_2o [ C] T_Puffer_17 [ C] T_Puffer 15u [ C] T_Solar_sek_VL [ C] T_Solar_sek_RL [ C] T_Kollektor_Dach2 [ C] T_Kollektor_Dach1 [ C] T_Solar_primär_VL [ C] T_Solar_primär_RL [ C] p_solar_primär [bar] T_Aussen [ C] P_Einstr [W/m²] P_EL_Solar [W] 12 1 8 6 4 2 Power [W] 19.6.9 : 19.6.9 2:24 19.6.9 4:48 19.6.9 7:12 19.6.9 9:36 19.6.9 12: 19.6.9 14:24 19.6.9 16:48 19.6.9 19:12 19.6.9 21:36 2.6.9 : Fig. 5. Temperature and solar irradiation (P_Einstr) of the solar thermal system on June 19th, 29 3. INTEGRATION OF AUXILIARY HEATER The auxiliary heater in this project consists of three natural gas boilers, which are situated in a third building just beside the town hall. These boilers are connected to the heat storage with a short district heating network. One of those three boilers is a condensing natural gas boiler which should receive as low as possible return temperatures to be able to condensate. The auxiliary heater is able to charge the top 2 Litre of the heat store. Fig.6 shows the return temperature (T_FW_RL_prim) in the primary circuit of the auxiliary heater which is fluctuating at around 6 C, even though the temperature in the heat store below the height of the return pipe (T_Puffer and T_Puffer_unten) most of the time is around 45 to 5 C. A more advanced control strategy should be able to hand over this low temperature in the tank to the condensing natural gas boiler in order to allow condensation for which return temperatures far below 55 C are necessary. Fernwärme T_Puffer_oben T_Puffer T_Puffer_unten T_FWsek_VL T_FWsek_RL T_FW_VL_prim T_FW_RL_prim P_FW_prim Temperatur [ C] 9 8 7 6 5 4 3 2 1 18 16 14 12 1 8 6 4 2 Leistung [kw] 11.2.9 : 11.2.9 2:24 11.2.9 4:48 11.2.9 7:12 11.2.9 9:36 11.2.9 12: 11.2.9 14:24 11.2.9 16:48 11.2.9 19:12 11.2.9 21:36 12.2.9 : Fig. 6. Temperatures and heat capacity (P_FW_prim) of the hot store and the auxiliary heater on February 11th, 29 4. HEAT DISTRIBUTION In fig.7 the temperatures in the heat distribution net is shown. The ceiling heating elements (T_DHzg_VL/RL) have quite low return temperatures in the range of 35 C which is fine for solar thermal heating. Return temperatures of the radiators in the old Town Hall (T_Hzg_RH_RL) and of the radiators in the new Service Centre (T_HK_RL) are at a temperature level of acceptable 4 to 5 C. In the new built Service Centre unfortunately some additional high temperature heating elements were installed directly below the windows in order to avoid condensation at the windows. These heating elements (T_Fenstertr_RL/VL) are operated at a temperature level between 5 and 6 C, which is much too high for efficient solar heating. Most likely this is caused by too I.S.S.N. 267-5538 21 JSE

JOURNAL OF SUSTENABLE ENERGY, VOL. 1, NO. 2, JUNE, 21 low inlet air temperature of the air ventilation system and these window heating elements are used for compensation. Wärmeverteilung und Abgabe T_Hzg_RH_VL [ C] T_Hzg_RH_RL [ C] T_DHzg_RL [ C] T_DHzg_VL [ C] T_Torls_RL [ C] T_Torls_VL [ C] T_HK_RL [ C] T_HK_VL [ C] T_Fenstertr_RL [ C] T_Fenstertr_VL [ C] 7 65 6 Temperatur [ C] 55 5 45 4 35 3 25 2 11.2.9 : 11.2.9 2:24 11.2.9 4:48 11.2.9 7:12 11.2.9 9:36 11.2.9 12: 11.2.9 14:24 11.2.9 16:48 11.2.9 19:12 11.2.9 21:36 12.2.9 : Fig. 7. Temperatures of the heat distribution system on February 11th, 29 5. ABSORPTION CHILLER In fig.8 a screenshot of the absorption chiller is shown during typical steady state operating conditions. Generator heating circuit is operated with relative low flow rate resulting in a temperature difference of about 9K (5K is recommended) but with the advantage of reduced electricity consumption for the pump. According to the Yazaki datasheet 6% of the nominal flow rate causes only a reduction of 1 to 15% of cooling power. Cooling water from the cooling tower is mixed up to about 29 C in order to avoid crystallization of the liquid lithium-chloride. Temperature difference in the cold water circuit is about 6K, which is according to the design data. As it can be seen in the screenshot all pumps are operated with fixed flow rates, just the fan of the wet cooling tower is speed controlled. In fig.9 and fig.1 the evolution of temperatures, heat capacities, electricity consumption and water consumption of the absorption chiller is shown for June 18th, 29. Most of the time the chiller is operating in a quite unstable stop and go mode. The reason for that is that if the minimum cold water temperature of 6.5 C is reached, the chiller itself is internally switching of for a while in order to avoid freezing of the water. After increasing of cold water temperature to more than 11 C, the chiller starts cooling again. At about 14: the chiller is switching off because the minimum generator temperature of 79 C (T_Hzg_VL_55) is not available anymore. After about 3 minutes the available temperature increased and the chiller started again. Fig. 8. Screenshot of the absorption chiller and wet cooling tower on July 3 th, 29 I.S.S.N. 267-5538 21 JSE

JOURNAL OF SUSTENABLE ENERGY, VOL. 1, NO. 2, JUNE, 21 Steady state operation in fig.1 shows between 17: and 18: constant cooling power of the chiller (P_AKM_Kälte) of about 23 kw powered with about 5 kw (P_AKM_Austr) resulting in a thermal COP therm (coefficient of performance) of about.46. According to the data sheet and the operating curves of this chiller the power under these operating conditions (generator: 84/74 C; back cooling: 29/32 C; cold water: 8/13 C; generator flow rate about 5% of nominal flow rate) should be about 25 to 27 kw. This shows that the chiller is working as it should, but the overall control strategy seems to have quite some potential for improvements. Further analyzing the steady state operation at about 18: shows that the consumed electricity power of the absorption chiller including generator and cold water pump is about.72 kw (P_EL_AKM) and of the wet cooling tower including fan and pump is about 2.35 kw (P_EL_Kühlturm), in total 3.5 kw. This results in an electrical COP el of 7.5 (=23/3.5) only for operating the chiller and producing cold water. The pumps of the primary and secondary solar circuits are consuming about.53 kw (not shown in fig.1) electricity. Including this electricity consumption results in an electrical COP el of 6.4 (=23/3.58) for solar autonomous cooling in steady state operating conditions. Absorption chiller 1 9 8 T_Hzg_VL_55 [ C] T_AKM_AustreiberVL [ C] T_AKM_Kaltw asservl [ C] T_Kühlturm_RL [ C] T_AKM_Kondensator_VL [ C] T_AKM_Puffer-AustreiberVL [ C] T_AKM_AustreiberRL [ C] T_AKM_Kaltw asserrl [ C] T_AKM_Kondensator_RL_bzw _T_Kühlturm_VL [ C] Temperature [ C] 7 6 5 4 3 2 1 : 2:24 4:48 7:12 9:36 12: 14:24 16:48 19:12 21:36 19.6.9 : Fig. 9. Temperatures around the absorption chiller on June 18th,29 Power and water consumption absorption chiller 7 P_AKM_Austr [W] P_AKM_Kälte [W] P_Einstr [W] P_EL_Kühlturm [W] P_EL_AKM [W] P_EL_Wasseraufber [W] P_EL_Wannenheizung [W] V_Kühlturm [Liter] 7 6 6 Power [W] 5 4 3 2 5 4 3 2 water consumption [l] 1 1 : 2:24 4:48 7:12 9:36 12: 14:24 16:48 19:12 21:36 19.6.9 : Fig. 1. Heat capacity and electrical consumption around the absorption chiller on June 18th, 29 On long term for the period of the three months May, June and July 29 the following average SPF s (seasonal performance factor) could be determined: SPF therm =.41, SPF el = 4.2 for chiller and cooling tower including the three pumps and SPF el = 3.9, if additionally the solar circuit pumps are included. In this electrical SPF el the electricity consumption of the auxiliary natural gas boiler and the two pumps, which are in operation to heat the hot tank, is not included. As it can be observed the chiller is operating in an extremely stop and go mode which does not support high values for SPF th and SPF el. The reason for that was found in a mistake in the control program of the building itself. This mistake resulted in almost closed control valves of the chilled ceilings most of the time which naturally reduced dramatically the cold water flow and therefore only very reduced cooling of the office rooms was possible. If the cooling load is artificially reduced that much then of I.S.S.N. 267-5538 21 JSE

JOURNAL OF SUSTENABLE ENERGY, VOL. 1, NO. 2, JUNE, 21 course there is no need for cold production of the chiller leading to this stop and go behavior. In Fig. 11 the average position of all control valves (Mittelwert Ventilstellungen) is shown. Since % means the valve is closed, it can be observed that most of the time the valves are in average in quite closed positions between 1% and peak values up to 6% for very short times. For the summer 21 the control unit of the office building was reprogrammed and much better performance of the system and much higher comfort in the office rooms is expected. Ventilstellung [%] und Temperatur [ C]. Mittelwert Ventilstellungen [%] P_Einstr [W] T_Außen [ C] Polynomisch (Mittelwert Ventilstellungen [%]) Mittelwert T_Raum [ C] 7 65 6 55 5 45 4 35 3 25 2 15 1 5 9.8. 1.8. 11.8. 12.8. 13.8. 14.8. 15.8. 16.8. 17.8. 18.8. 19.8. 2.8. 21.8. 22.8. Fig. 11. Average control valve positions (Mittelwert Ventilstellungen) in relation to ambient temperature (T_Außen), solar irradiation (P_Einstr) and average of the 23 office room temperatures (Mittelwert T_Raum) 14 12 1 8 6 4 2 Einstrahlung [W] 6. DESSICANT EVAPORATIVE COOLING UNIT In fig.12 a screen shot of the air ventilation unit with Dessicant Evaporative Cooling (DEC) is shown. Accidentally this is a day with design ambient conditions for cooling in Austrian climate: 32 C ambient temperature and almost 4% relative humidity. Inlet conditions are 31.5 C and 38% relative humidity and supply air conditions, which are produced by the DEC system, are 19.1 C and 78% relative humidity. Outlet air of the building has 26.8 C and 48% relative humidity and exhaust air has 49.5 C and 2% relative humidity. Based on these data it can be stated that the DEC system is operating quite well in steady state conditions. Fig. 12. Screenshot of the desiccant ventilation unit on June 19th, 29 Temperatures and relative humidities are shown for June 18th, 29 for the supply air stream in fig.13 and for the exhaust air stream in fig.14. At about 5: in the morning the air ventilation system starts exchanging air I.S.S.N. 267-5538 21 JSE

JOURNAL OF SUSTENABLE ENERGY, VOL. 1, NO. 2, JUNE, 21 by sucking in ambient air and blowing it into the building. No heat recovery and no cooling is active. Due to several heat transfer effects (heat losses of motor of the fan and technical room temperature above 3 C) at about 5:3 the supply temperature (T_DEC_ZUL) finally is about 9K higher (around 19 C) than the ambient air temperature (T_Aussen) which is around 1 C at that time. For cooling down the building mass in order to keep lower room temperatures during the day it would be advantageous to flush the building with the ambient air directly. Therefore it would be a potential of optimization to switch off the supply ventilator and only to run the exhaust ventilator and to open the windows of the office rooms, what is possible since all windows are equipped with automatic actuators. Additionally the electricity consumption (about 2.7 kw nominal power) of the inlet air ventilation could be avoided. At about 9:3 the DEC system starts active cooling and is active until 17:. Supply air is cooled to around 19 C (T_DEC_ZUL) with relative humidity of about 78% (rh_dec_zul). For drying the sorption wheel the water/air heat exchanger is supplied from the tank with hot water at around 8 to 85 C with heating power of about 45 kw. At about 16:3 the sorption wheel is able to dry the air from 3 C/4% rh (T_DEC_AUL / rh_dec_aul) to 44 C/14% rh (T_DEC_ZUL_nach SR / rh_dec_zul_nach SR) which means a reduction of about 3g/kg absolute water content (from 1.6 g/kg to 7.6 g/kg) Supply air - desiccant evaporative cooling device 1 9 8 Temperature [ C] 7 6 5 4 3 2 1 1 9 8 7 6 5 4 3 2 1 relative humidity [%] T_Hzg_VL_55 [ C] T_Aussen [ C] T_DEC_AUL [ C] T_DEC_NachheizregRL [ C] v_dec_zul [m/s] T_DEC_ZUL [ C] T_DEC_ZUL_nach SR [ C] T_DEC_ZUL_nach WRG [ C] rh_dec_aul [% rh] rh_dec_zul [% rh] : 2:24 4:48 7:12 9:36 12: 14:24 16:48 19:12 21:36 19.6.9 : rh_dec_zul_nach SR [% rh] rh_dec_zul_nach WRG [% rh] Fig. 13. DEC supply air stream on June 18th, 29 Exhaust air - desiccant evaporative cooling device 1 Temperatur [ C] 9 8 7 6 5 4 3 2 1 : 2:24 4:48 7:12 9:36 12: 14:24 16:48 19:12 21:36 1 9 8 7 6 5 4 3 2 1 19.6.9 : Fig. 14. DEC exhaust air stream on June 18th, 29 relative humidity [%] v_dec_abl [m/s] T_DEC_ABL [ C] T_DEC_ABL_nach WRG [ C] T_DEC_FOL [ C] T_DEC_AustreiberRL [ C] T_Hzg_VL_55 [ C] T_DEC_Austr_VL [ C] T_DEC_Austr_RL [ C] T_Büro_Raum1 [ C] T_Büro_Raum2 [ C] T_Büro_Raum3 [ C] T_Archiv_ZUL [ C] T_Büro_ZUL [ C] T_Museumsd_ZUL [ C] rh_dec_abl [% rh] rh_dec_abl_nach WRG [% rh] rh_dec_fol [% rh] A quite big electricity consumer for this DEC system is the water treatment equipment with nominal power of about.8 kw stationary consumption for a circulation pump and the UV-lamp for disinfection and further.8 kw occasionally for the osmosis filter when fresh water is filled into the system. In June and July 29 this resulted in average to electricity consumption just for water treatment of about 25 kwh per day, whereas running the DEC system itself consumed about 18 kwh per day. For comparison: thermal energy used for regeneration of the sorption wheel in average was 176 kwh per day in the two months June and July. Even in winter time the water treatment unit was in operation despite the fact that no water was needed because the humidification unit in the air handling unit was switched off. This resulted during the period December 8 to February 9 in water consumption of about 81 m 3 and electricity consumption of about I.S.S.N. 267-5538 21 JSE

169 kwh. On November 2 th, 29 the controller of the water treatment unit was reprogrammed to minimum necessary activities, just to keep the components maintained as needed as shown in Fig. 15. Before the changes the electricity consumption was constant at around 8 W for running the UV-Lamp and the circulation pump for that. When the UV-Lamp got too warm the system cooled down by flushing the water to the drainage and refilling with fresh and cold water which V_DEC_Befeuchter [l/5min] 1 9 8 7 6 5 4 3 2 1 19.11.9 : 19.11.9 6: 19.11.9 12: JOURNAL OF SUSTENABLE ENERGY, VOL. 1, NO. 2, JUNE, 21 19.11.9 18: 2.11.9 : 2.11.9 6: 2.11.9 12: caused the activity of the osmose filter with the intergrated high pressure pump resulting in a total power of up to about 16 W electricity consumption. After reprogramming in the months December 9 to February 21 the water consumption reduced to about 6 m 3 and electricity consumption to about 41 kwh. This means a reduction of 93% water consumption and 98% electricity consumption. 2.11.9 18: V_DEC_Befeuchter [Liter] 21.11.9 : 21.11.9 6: P_EL_Wasseraufber [W] 21.11.9 12: 21.11.9 18: 3 25 2 15 1 5 22.11.9 : Fig. 15. Electricity consumption (P_EL_Wasseraufber) and water consumption (V_DEC_Befeuchter) of water treatment unit before and after reprogramming P_EL_Wasseraufbereitung [W] 7. CONCLUSIONS For the solar heating and cooling plant of the town hall in Gleisdorf a detailed monitoring campaign is realized which allows to evaluate all heat flows, electricity flows, water consumption and of course all temperatures and relative humidity in the system and the building. First year of monitoring shows good results of the solar heating part with annual electrical SPF el of 67 kwh therm /kwh el and up to 82 kwh therm /kwh el as monthly peak values. Heat losses of the heat store are between 4 and 25% with in average 9% for a 12 month period. Acceptable results of the single components like the absorption chiller (COP el of 7.5) and the DEC system (19 C supply air at 32 C ambient air temperature) during steady state conditions could be presented. When comparing COP`s and SPF`s (COP el of 7.5 decreases to a SPF el of 4.2), this shows that quite big potentials for improvements exist in optimizing the overall control strategy of the building in cooperation with the heat/cold delivery system and reduction of parasitic electricity consumption, especially for water treatment. REFERENCES [1] HighCombi project homepage: www.highcombi.eu [2] SOLAIR homepage for general information on solar cooling: www.solair-project.eu [3] IEA SHC Task38 homepage for detailed information on solar cooling: www.iea-shc.org/task38 [4] Thür A., et.al., Solar Heating and Cooling Town Hall Gleisdorf, 3rd International Conference Solar Air-Conditioning, Palermo, Italien, 29 [5] Thür A., et.al., Solar Heating and Cooling for the Solar City Gleisdorf, ISES Solar World Congress 29, Johannesburg, Südafrika, 29 I.S.S.N. 267-5538 21 JSE