Ultrasonic Reflective Sensor

Similar documents
Ultrasonic Reflective Sensor

Ultrasonic Proximity Sensor

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Model Number Structure

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

onlinecomponents.com

Scale 0: 10 k Scale 50: 10 k (see note 2)

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Ultrasonic Proximity Sensor

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Original instructions Sense7-series Non-contact coded safety switch

Original instructions JSNY7 Magnetic switch

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

E3M-V. Mark Sensor. Applications

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

E3FA PHOTOELECTRIC SENSORS

K7L-U/K7L-UD. Liquid Leakage Sensor Amplifiers for Long-distance Wiring. Enables longdistance. up to 400 m.

E3FA PHOTOELECTRIC SENSORS

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

Annuciator Logic Controllers

Current monitoring relay, overcurrent, undercurrent and current window. MCU024R2, MCU230R2

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

TEMPERATURE CONTROLLER

E3FA PHOTOELECTRIC SENSORS

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Model Number Structure

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

MODEL 834M1 ACCELEROMETER

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

MICRO SWITCH NT Series

CD6102 / CD6102 OC / CD6102-2

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

MICRO SWITCH NT Series

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Model Number Structure. Floatless Level Switch (Basic Type)

Active Infrared Multi Beam Sensors. R Series

SKORPION Process Air Heater

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Duct Humidity/Temp Sensor

AUTO SPEED BLENDER INSTRUCTION MANUAL MODEL: BLCLMB1

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

MODEL 4000A & 4001A ACCELEROMETER

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

R-GAGE QT50R-AFS Sensor

Operations Manual. Motion Detector Module Model ZS10

Active Infrared Multi Beam Sensors

Instruction Leaflet. Read instructions before operating. Retain for future reference.

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

MINI-BEAM Expert Series

MN908 No. 282C Replaces 282B LB7013

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

EQUIPMENT Operation Manual

UFM-T100H US ES CA Power Alarm Test TM

Compact, Photoelectric Sensor with Built-in Amplifier and Teaching Function. Mark Sensor with Stainless Steel Housing

E5CN-FR Limit Controller USER S MANUAL

FEATURES AND BENEFITS

User s Manual and Operating Instructions

3M Benchtop Air Ionizer 963E. User s Guide

Instruction Leaflet. Read instructions before operating. Retain for future reference.

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018

XT Series Thermostats

Instruction Leaflet. Read instructions before operating. Retain for future reference.

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Warranty Registration

Duct Mount. Installation Instructions

1022 R/T Remote Monitor

KILOVAC K1K High-Voltage Contactor

HIH-4602-L Series Humidity Sensors

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

IMPORTANT SAFETY INFORMATION:

USER MANUAL SAVE THESE INSTRUCTIONS

Room Humidity/Temp Sensor

SONANCE PROFESSIONAL SERIES

HOA6480 Series Barcode Sensor Infrared Products

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

MBCE-110/230UV Flame Sensor Module

WITH OMRON E5CC CONTROL

SONANCE PROFESSIONAL SERIES

User s Manual and Operating Instructions

Specification Status: Released

Operation Manual Vortex mixer unitexer 1

Transcription:

Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable operation check function allows easy adjustment to a proper mounting direction. Mono-block construction with a sensor, power supply, and terminals ensures easy wiring. Incorporates synchronous selector and reference pulse I/O terminals ideal for parallel-operation use without mutual interference. Ordering Information Sensing method Reflective Model for AC for DC DC12-24 Application Examples Detection of cellophane, glass, and photosensitive paper Detection of objects on conveyors or discrimination of object heights 1

Specifications Ratings/Characteristics Supply voltage Power consumption Note: Models operating at 12 to 24 VDC are available. Specify the supply voltage when ordering. and Dead Ranges 100, 110, 200, and 220 VAC ± 10% at 50/60 Hz (see note) Approx. 2.5 VA Adjustable between 0.3 and 3 m (selectable ranges of 0.3 and 2 m or 1.3 and 3 m) Standard sensing object Minimum sensing object Ultrasonic oscillation frequency 100-mm dia., 1.5-m-long metal or plastic round pipe 50 x 50 mm flat plate Approx. 40 khz Directional angle Half-value angle: 25 Response time Operate time: 0.25 s; release time: 0.5 s Control output Contact output: SPDT 3 A at 220 VAC, cos dia.=1 or 3 A at 24 VDC, cos dia.=1 Ambient temperature : 20 C to 55 C (with no icing) Ambient humidity : 45% to 85% Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 1,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 25 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions Shock resistance Destruction: 500 m/s 2 (approx. 50G) 3 times each in ±X, ±Y, and ±Z directions Life expectancy Mechanical 20,000,000 operations min. (output relay) Electrical 100,000 operations min. Enclosure rating IEC IP60 Weight Approx. 500 g without Mounting Bracket Approx. 600 g with Mounting Bracket 1. Distance Selector Set to a Range Between 0.3 and 2 m 2. Distance Selector Set to a Range Between 1.3 and 3 m Reference level If the sensing distance (A) is set to 2 m, the sensing zone (B) is 1.5 to 2 m. If the sensing distance (A) is set to 0.3 m, the sensing zone (B) is 0 to 0.3 m. Reference level If the sensing distance (A) is set to 3 m, the sensing zone (B) is 1.5 to 3 m. If the sensing distance (A) is set to 1.3 m, the sensing zone (B) is 0 to 1.3 m. A: The sensing distance (A) is adjustable with the distance selector to a range between 0.3 and 2 m. B: Sensing zone Dead range A: Dead range The sensing distance (A) is adjustable with the distance selector to a range between 1.3 and 3 m. B: Sensing zone range: 0.5 m range: 1.5 m The distance from the reference level to the operating range (detection zone). The distance from the reference level to the operating range (detection zone). An object may be detected due to multiple reflection if the object is in the dead range, in which case however, the detection of the object will not be stable. Therefore, do not attempt to use the to detect an object in the dead range by making use of multiple reflection. Note: Multiple reflection is a phenomenon caused by an ultrasonic beam reflected several times repeatedly between the sensing object and the or nearby objects such as the ceiling. 2

Engineering Data Zone (Typical Examples) The operating zone is the sensing range of the at the sensing distance with the sensing object moved vertically towards the ultrasonic beam. The operating zone varies with the sensing distance and sensing object. Distance (cm) Distance (cm) Distance (cm) Sensing object : 100 dia. x 1,000 (mm) Sensing object: 200 x 200 (mm) flat plate Sensing object : 25 dia. x 100 (mm) Ultrasonic Ultrasonic Ultrasonic Reference Each of the following illustrations indicates the operating zone with the mounted to the ceiling for the purpose of detecting the human body. In either case, make sure that the lower limit of the sensing range is approximately 0.5 m above the floor so that the floor will not be detected. Typical Example If more than one Unit is used within a maximum distance of 8 m, be sure to wire the Units so that the Units will be in synchronous operation. Refer to External Connections for details. Distance selector set to a range between 1.3 and 3 m. 8 m max. (operating zone) = Approx. 1.5 m Approx. 0.5 m 2 m (operating zone) = Approx. 1.5 m 3 m If there is a door between two Units located for different operating zones as shown in the following illustration, be sure to wire the Units so that the Units will be in synchronous operation. Approx. 0.5 m 550 mm 750 mm 450 mm 600 mm Door 3

Dimensions Note: All units are in millimeters unless otherwise indicated. Mounting Dimensions Two, 6.5 dia. 6.6 dia. 24 dia. Rubber cap Indicator Installation External Connections Example of Connections of the in Asynchronous Operation Example of Connections of the in Synchronous Operation 100/110 VAC 200/220 VAC 100/110 VAC 200/220 VAC 100/110 VAC 200/220 VAC Contact output Contact output Contact output Note: 1. If the synchronous operation of the is not required, set the reference pulse selector to ON. Keep terminals 7 and 8 open. 2. Use a cable with an external diameter of 10 mm max. for wiring. Note: 1. If the synchronous operation of the is required, set the reference pulse selector of only one Unit to ON. Then connect terminal 7 of all the Units together and do the same for terminal 8. 2. A maximum of 50 Units can be connected in synchronous operation. 3. Do not wire the lines for synchronous operation use (i.e., wires connecting to terminals 7 and 8) alongside power lines in the same conduit. 4. Use a shielded cable with an external diameter of 10 mm max. for wiring. 5. Make sure that all the Units in synchronous operation are turned on, otherwise none of the Units will operate. 4

Adjustments Reference Pulse Selector Position If more than one Unit is used at one location, the Units will need to be in synchronous operation to prevent mutual interference. In that case, set the reference pulse selector of only one Unit to ON. Set the reference pulse selector of each Unit to ON if the Units are in asynchronous operation. Refer to External Connections for details. Sensing side Operation indicator adjuster Distance selector d range l 0.1 d min. 0.1 d min. Reference pulse selector Sensing Distance Adjustments Before adjusting the sensing distance, remove the rubber cap from the top of the. Be sure to put on the rubber cap after the sensing distance is adjusted. 1. Apply a flat-blade screwdriver to the groove of the distance selector to set the distance selector to either a range between 0.3 and 2 m or a range between 1.3 and 3 m according to the desired sensing distance and operating range. 2. To set the sensing distance, first locate a flat plate as a sensing object that is approximately 20-by-20 cm at the desired sensing distance. Then gradually turn the sensing distance adjuster clockwise (i.e., in the direction increasing the sensing distance) until the relay operates. The operation indicator will be lit when the relay operates. Standard Sensing Distance Settings If the sensing object is moving vertically towards the ultrasonic beam (i.e., the is in normal sensing operation), set the sensing distance so that the sensing side of the object passes through the center of the operating range as shown in the following illustration. d range l Sensing side From the above, the minimum height (h) of the sensing object is expressed by 0.2d. If the sensing object is comparatively low in height or if the is used for the delicate height discrimination of objects, it will be necessary to set the sensing distance to a small value. If the sensing object is moving parallel to the ultrasonic beam for level or height detection, the sensing distance will be the distance required for the sensing object to move. d range Operation Check After adjusting the sensing distance, check that the operates properly by locating the sensing object within the operating range. Then remove the sensing object and check that the operation indicator is not lit. The operating indicator may be still be lit or flashing after the sensing object is removed. In that case, the may be malfunctioning due to beam reflection from objects outside the operating range or affected by ambient wind or temperature, in which case, eliminate the cause or change the mounting position or direction of the. If the mounting position or direction of the is changed, be sure to check the sensing distance and the operation of the E4A- 3K. Operation indicator flashing Operation indicator not lit If there is an object, such as a floor, wall, or conveyor, located behind the sensing object, make sure that the distance between the set sensing distance (d) and the background object is 0.1d min. Furthermore, make sure that the set sensing distance (d) is at least 0.1d closer to the from the maximum limit of the operating range as shown in the following illustration. 5

Precautions Correct Use Mounting Angle If the is in level control or distance control of sensing objects, the stability of signal detection will depend on the sensing surface condition of the objects. Considering the repose angle of the objects, mount the so that the ultrasonic beam and the sensing surface of each object meet at right angles to each other. Surrounding Objects Make sure that the is free from surrounding objects that reflect the ultrasonic beam diffusion, otherwise the may malfunction. In particular, pay the utmost attention so that no side lobe of the ultrasonic beam will be reflected by such objects. Mounting Securely mount the by using the nuts provided with the or the mounting holes of the. Refer to Dimensions for details. Do not strike the with any hammer or other object, otherwise the will no longer be water-resistant. If the is not mounted securely, the may be damaged by vibration or may not detect sensing objects accurately due to a possible change in the mounting position. Environmental Conditions Do not use the at a temperature exceeding the rated range or outdoors, otherwise the reliability and life of the will decrease. The Ultrasonic Reflective utilizes the air as a beam transmission media. Do not use the in places with radical convection or extreme local temperature changes. For example, if there is a hot air curtain that causes turbulence within the sensing area, the may malfunction. Turbulence Air curtain The jetting sound of air nozzles includes noise of a wide frequency range, which will affect the operation of the. Do not use an air nozzle near the. The sensing distance of the will decrease if there is any water drops on the surface of the emitter or receiver. The reflective model may not detect any objects if there is any object absorbing sound, such as powder and cotton, on the surface of the emitter or receiver. 6

7

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. CSM DS_E_3_1 D064-E1 OMRON Corporation Industrial Automation Company Sensing Devices Division H.Q. Application s Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7068/Fax: (81)75-344-7107 In the interest of product improvement, specifications are subject to change without notice.

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2011.9 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2011 All Right Reserved.

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: AC120/240 DC12/24