Model TWBS.SHE Tempered Water Blending System

Similar documents
Model 9201EFE Tempered Water Blending System

Model 9201EW Tempered Water Blending System

Model 7656WCC Eye/face Wash

Model TWBS.EW.H Tempered Water Blending System

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash

Model 8356WCC Pull-Down Shower Eye/Face Wash

Model 9001, Alarm

Model Combination Shower Eye/Face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model 9001, Alarm

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Model 1011/1011HPS Drinking Fountain

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 7500EB Portable Eyewash with Heater

Model 1900 Retrofit Bottle Filler

INSTALLATION & TESTING MANUAL

Model 7603BL/7603BL240 Heated Blanket for 7603 Portable Eyewash

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

Model 7611 Eye/Face Wash

3121FR Pedestal Mounted Drinking Fountain

Model H1011.8/H1011.8HPS Water Cooler

INSTALLATION & TESTING MANUAL

Model 7603/7603T/7603T240 Portable Eyewash / Portable Eyewash with Heater

Model 1920/1920HPS/1920W Bottle Filler

H Barrier-Free Wall Mounted Electric Drinking Fountain

H Barrier-Free Wall Mounted Electric Drinking Fountain

H1011.8HPS Barrier-Free Wall Mounted Electric Drinking Fountain

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

8317CTFP AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER Freeze Resistant

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

model1117l with1920 ADA Compliant Dual Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

AN AXION TM EYEWASH...

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

OUTLET HOT INLET COLD INLET INSTALLATION

Comfort Series Instant Hot Water System

TITAN FLOW CONTROL, INC.

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

ADA Compliant Wall-Mount Fountain and Bottle Filler

TOP 15 :: EMERGENCY EQUIPMENT

Inline Heater for Solvent or Gas. Installation and Operation Manual

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

TECHNICAL INSTRUCTIONS

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

Model SFMV Series. Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves

INSTALLATION, OPERATION AND MAINTENANCE

This Product MasterSpec Section is licensed by AVITRU, LLC to Haws Corporation ("Licensee").

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

PROOF BOX (All SD,DD, and TD 99 Models)

Ace Heaters LLC INSTALLATION and MAINTENANCE INSTRUCTIONS for ACE STORAGE TANKS INSTALLATION AND HOOKUP

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

TORRID MARINE YACHT QUALITY Since Owner s Manual

installation, operation & Maintenance manual Floor-mounted Induction units

INSTALLATION ADJUSTMENT SERVICE

Ace Heating Solutions, LLC INSTALLATION and MAINTENANCE INSTRUCTIONS for ACE STORAGE TANKS INSTALLATION AND HOOKUP

Expanded Backup Control Installation & Operator s Instruction Manual

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

Heater Installation Kit

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Duct Mount. Installation Instructions

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Installation Instructions / Warranty. PuraVida 15775XX1

OPERATION & INSTALLATION MANUAL

MEGATRON MODEL 2, 3, 4, and 5

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

LiqTec, V GRUNDFOS INSTRUCTIONS

EMERGENCY DRENCH SHOWER

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Flat Line Spray Systems Kits

Thermostatic Mixing Valves

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model TWBS.SHE Tempered Water Blending System No. 2080226 (5) NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of three years from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The thermostatic mixing valve manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose, which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions HAWS cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL, OR REQUIRE REPLACEMENT PARTS, PLEASE CALL: TECHNICAL SUPPORT: 1-800-766-5612 FOR CUSTOMER SERVICE: 1-888-640-4297 01/14 TWBS.SHE Page 1 of 6

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Valve operating principle: The Haws Corporation TWBS.SHE Emergency Valve thermostatically mixes hot and cold water to provide a safe fluid supply for emergency showers and eyewash equipment. The TWBS.SHE valve contains a secondary high temperature limit valve to provide additional protection to the user in the event of main tempering valve malfunction. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss, or main valve thermostat malfunction. Valve features: Paraffin filled thermostats with industry leading response time. Tempered water: Temperature is factory set to 85 F (29 C). Tempered water: High temperature limit is factory set to 85 F (29 C). The over temperature valve is calibrated to shut off the hot water inlet flow when the outlet temperature exceeds 95 F (35 C). Cold water by-pass valve opens if hot water fails. Actively suspends hot water flow when cold water supply is lost to protect against scalding. Cold water by-pass valves are closed during normal operation, regardless of flow rate. Valve sizing: The flow capacity table shown below contains discharge flow rates @ 85 F (29 C) outlet temperature with the valve tested under the conditions described by ASSE 1071. Flow Capacity Model No. Min flow Pressure drop across valve Cold water TWBS.SHE 1.0* 5 PSI 10 PSI 20 PSI 30 PSI 40 PSI 45 PSI By-pass @ 30 PSI 30 43 60 * Denotes minimum flow rate without re-circulation. 74 85 91 50 Valve specifications: Maximum operating pressure: 125 PSI Minimum / Maximum hot water temperature: 120 F / 180 F (49 C / 82 C). Tempered water temperature adjustment range: 60 F 85 F (15 C - 29 C) Compliance/Listings: ASSE 1071, NSF 61, California Lead Plumbing Law and applicable sections of CSA B125.3. IMPORTANT To ensure the proper operation of the TWBS.SHE valve it is essential to: Properly size the valve for each application. Keep the outlet temperature set between 60 F and 85 F (15 C - 29 C). Haws recommends a weekly testing and recording of the outlet water temperature. Failure to comply with installation and/or maintenance instructions could result in valve failure. 01/14 Model TWBS.SHE Page 2 of 6

Valve operation: INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Hot and cold water flows into the valve through two ports, marked C for cold and H for hot. The inlet water passes through check valves and valve seats into a mixing chamber, where the main thermostat is located. The temperature setting is controlled via the tempered water temperature adjustment screw which is located at the front of the valve. (See Installation Drawing). If the inlet temperature fluctuates or the pressure changes, the main thermostat moves an internal plunger which corrects outlet temperature back to the initial setting. In the event of cold water failure, the main thermostat completely closes the hot seat. Additionally, the cold water by-pass valves provide adequate cold water flow if the hot inlet fails. For additional safety, a second high temperature limit thermostat is located in the outlet stream. This thermostat shuts off at 95 F or higher temperatures, closing the hot inlet. Valve installation instructions: Installation and field adjustment of this device are the responsibility of the installer and shall be carried out in accordance with the following instructions: 1. This valve must be accessible for testing, adjustment and/or maintenance in its installed position. 2. If shutoff valves are installed for maintenance purposes, provisions shall be made to prevent unauthorized shutoff. 3. Flush the hot and cold supply lines prior to installation. 4. Connect the hot and cold supplies to the marked inlets. 5. Connect the outlet to the tempered water supply line. 6. Pressurize the emergency tempering valve and check all connections for leaks. Installation test procedure: 1. Confirm the discharge temperature at the eyewash station or drench shower. Reset the outlet temperature, if necessary, based on medical/safety authorities guidelines. (This establishes the preset level). Note: Turning the temperature adjusting screw counterclockwise will increase the temperature. 2. Close the hot water supply: The cold water by-pass must open and provide significant flow. 3. Open the hot water supply: The outlet temperature should return to the pre-set level. 4. Close the cold water supply (Do not use the check valve.): The flow rate must comply with the maximum cold shut off flow allowed by ASSE 1071 for this valve size. 5. Open the cold water supply: The outlet temperature should return to the pre-set level. Recommended valve testing procedure: 1. Open the eyewash and/or drench shower stations: Confirm and record the outlet temperature. Close the hot water inlet: The cold water by-pass valve must open. 2. Open the hot water inlet: The outlet temperature should return to the pre-set level. 3. Close the cold water supply (Do not use the check valve.): The flow rate must comply with the maximum cold shut off flow allowed by ASSE 1071 for this valve size. 4. Open the cold water supply: The outlet temperature should return to the pre-set level. 01/14 Model TWBS.SHE Page 3 of 6

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS TROUBLESHOOTING PROCEDURE PROBLEM CONDITION REPAIR CHECKLIST 1. Cold flow only. a. Confirm the hot water inlet pressure; it must be within +/- 10% of the cold inlet pressure. b. c. Confirm the hot water check-stop and/or upstream valve is fully open. Confirm the hot inlet check-stop screen is free of debris. Clean if necessary. 2. Flow rate is too low. a. Confirm all upstream inlet valves are fully open. b. Confirm the downstream valve is fully open. c. d. Confirm the hot and cold inlet pressures; both supplies must be 30 PSI, minimum. Confirm both the check-stops are free of debris. Clean if necessary. 3. No flow. a. Confirm all upstream inlet valves are fully open. b. Confirm the downstream valve is fully open. c. d. Confirm the hot and cold inlet pressures; both supplies must be 30 PSI, minimum. Confirm both the check-stops are free of debris. Clean if necessary. 4. Significantly lower outlet temperature. a. Confirm the hot water inlet pressure; it must be within +/- 10% of the cold inlet pressure. b. Confirm the cold water bypass valve is free of debris. Clean if necessary. 01/14 Model TWBS.SHE Page 4 of 6

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS WEEK NO. (1 THRU 26) WEEKLY TEST RESULTS (ONE YEAR)* OUTLET BY- TEMP PASS ( F) OPEN? (Y/N) WATER FAILURE? (PASS/FAIL) WEEK NO. (27 THRU 52) 1 27 2 28 3 29 4 30 5 31 6 32 7 33 8 34 9 35 10 36 11 37 12 38 13 39 14 40 15 41 16 42 17 43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25 51 26 52 OUTLET TEMP ( F) BY- PASS OPEN? (Y/N) WATER FAILURE? (PASS/FAIL) *Notice to testing personnel: This sheet should be used as a template for capturing the test results of this valve for one year. Please make a copy of this sheet for future testing prior to writing on this one. 2014 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 01/14 Model TWBS.SHE Page 5 of 6

PAGE 6 OF 6 THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. 7 1/4 HOT WATER INLET 1 1/4" NPT(F) 3 5/8 TEMPERED WATER OUTLET 1 1/4" NPT(F) 1" 5" 9 5/8 WATER INLET 1 1/4" NPT(F) TEMPERED WATER TEMPERATURE ADJUSTMENT SCREW 4 3/4 HIGH TEMPERATURE VALVE HOT WATER CHECK STOP (REMOVE CAP TO ACCESS SCREEN) 11" WATER CHECK STOP (REMOVE CAP TO ACCESS SCREEN) MAIN TEMPERING VALVE C 2014 ECN NO. REVISED PER BY: 4396 ECN: 4887 HM DRAWN: DATE: CHK'D.: VWC 8/13/10 APPROVED: DATE: MODEL(S) TWBS.SHE 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (755) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM PART NUMBER DRAWING NO. SCALE: 1:4 DRAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 1 R Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080226.D REV 15965A 5