Customized MCPs for Analytical Instruments. An MCP for every application

Similar documents
Instrumental technique (MCP detectors) - Kamalesh ( )

Diamond Windows & MCP Detectors for Synchrotron Applications

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Physics Requirements for the CXI Detector Stage

Surface Concept Product Catalog 2014

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Doc. No. SP R0. CXI Detector stage. Prepared by: Signature Date Jean-Charles Castagna Design Engineer

Unique Solutions for Your Research. Introduction to Velocitas VMI. Contents.

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

Variable Temperature Microprobe Systems

LCLS Instruments. Jerry Hastings June 20, 2008 LCLS

Experimental Particle Physics PHYS6011 Joel Goldstein, RAL

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

Electron detectors. The most used signals in a scanning electron microscope in standard conditions are the electrons and in particular the SE.

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

ADVANCED SILICON DETECTORS FOR ELECTRON IMAGING & COUNTING

Spot on Fraunhofer IAF

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

Industrial presentation. Philippe Marchais - July 3rd, NDIP Tours

Variable Temperature Options for Optical Experiments

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

MOXTEK MULTI-LAYER OPTICS AND X-RAY TECHNOLOGY

XEUS mirror calibration:

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

An FT-NIR Primer. NR800-A-006

More Precision. Innovative Sensor Technologies. Displacement Distance Position. Dimension Temperature Colour

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

Gaseous detectors. 1

LECTURE 11. Dr. Teresa D. Golden University of North Texas Department of Chemistry

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Spectrum Detector, Inc.

RAMAN SPECTROSCOPY See more, faster than ever before

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

SUNSTAR 传感与控制 TEL: FAX: DATASHEET Lightingg Solutions 1100 Series High Stabi

Recent Advances in Large Area Micro-channel Plates and LAPPD TM

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

Model S FT-IR SPECTROMETER

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

More Precision. thicknesssensor // The sensor for precise thickness measurements

BGA Rework Station Pro-660

DART-Thermo LTQ/Orbitrap Interface Manual

Beam Loss Position Monitoring with Optical Fibres at DELTA

CCD and CID solid-state detectors

- Basic information of Laser Scan detector

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Measuring Couch Motion Accuracy with X-ray Beam Fluence

High Throughput Large Area Silicon Drift Detectors

TESCAN MIRA FESEM Presentation Global Supplier of Scanning Electron Microscopes

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

LHCb Rich Detectors Control and High Voltage Systems

Ultra-Thin Flexible Heaters

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

R&D Fast and lightweight EIC integrated tracking system Barrel MicroMegas & Forward Triple-GEM

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

FLIM/FFS and Nanoimaging Upgrade of Olympus confocal microscopes

SICK AG WHITEPAPER. safehddm TM THE NEW SCANNING TECHNOLOGY FOR SAFETY LASER SCANNERS

Demands on Electro-optical Cameras for Sensing and Mapping

WHAT IS LASER ULTRASONIC TESTING?

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Doc. No. SP R0. CXI Reference Laser. Prepared by: Jean-Charles Castagna Signature Date Design Engineer

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

Sensor solutions for the graphics industry

Micromegas in a Bulk

The Art and Science of Being Cool

Model : LPSA-40A Please read this manual carefully before using the instrument Labnics Equipment

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

An Introduction to Mass Spectrometry

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Status and perspectives of the Virgo detector

scale analysis to micro scale imaging-ftir. State of the art and future perspectives.

CALIBRATION HOW IT WORKS

LASER SAFETY BARRIER

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Technologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System

Advanced Electron Detector and Acquisition System

Advantages / Characteristics

for Microelectronics Packaging Dave Vallett PeakSource Analytical, LLC Fairfax, Vermont, USA

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

NON-DESTRUCTIVE 2-D BEAM PROFILE MONITOR USING GAS SHEET IN J-PARC LINAC -overview & hardware construction-

Antoine Drouart DSM/DAPNIA/SPhN. Köln, 5 th of December,

The SLAC Detector R&D Program

Optical Techniques for Industrial Inspection

CALIBRATION HOW IT WORKS

gray Laser Power Detectors For fast and accurate measurements

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

2008 JINST 3 S The CMS experiment at the CERN LHC THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS.

OPEN PATH DETECTION OF ACROLEIN LEAKS

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

ESTB Proposal from the Stony Brook University: Test of a RICH-Prototype Based on CsI-GEMs

Thermo-Finnigan LCQ Interface Manual

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

CCTV, HOW DOES IT WORK?

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Transcription:

Customized MCPs for Analytical Instruments An MCP for every application

What are Microchannel Plates? (MCPs) Microchannel plates (MCPs) are solid state detectors consisting of parallel arrays of tiny single channel electron multipliers, fused together in a parallel array. Channel densities are typically 1 10 million channels per cm 2 MCPs can be made in a wide range of shapes and sizes to fill specific application needs MCPs can be used to detect ions, electrons, UV Photons and both soft and hard X Rays Photomicrograph of a 2 micron pore MCP.

Electron Multiplication An input event (ion, electron or photon) impinging on the focal plane will trigger an avalanche of electrons resulting in an amplification factor of up to 100,000 The cascading effects of a second or third array can result in an amplification factor of up to 100,000,000 with less than 1 count/second/cm of added noise The multiplication process shows a single electron cascading into secondary or tertiary electrons for increased amplification in each single channel. LEARN MORE

Photonis LongLife TM Microchannel Plates TruFlite TM MCPs have been specially manufactured to be ultra flat to +5µm Ideally suited for Time of Flight applications to reduce time jitter variance by up to 15%. MountingPad TM MCPs are patented rimless MCPs that have rigid areas to attach to a housing without damaging pores The rimless MCP prevents cracking and warping due to temperature and humidity The rigid areas provide a gap between the active channels and mounting hardware to allow gas to vent, eliminating noise Air stable All Photonis LongLife TM MCPs are specially designed to provide longer lifetime with superior detection capability with pore sizes as small as 2µm. All Photonis MCPs can be ordered with an exclusive Extended Dynamic Range option that increases detection up to ten times versus traditional MCPs. TruFlite TM MCP MountingPad TM MCP Download the Brochure

Wide Range of Shapes and Sizes MCPs can be manufactured in a wide range of shapes and sizes to fit a specific application or instrument Sizes range from 2mm to 160mm plates Round Square or rectangle Center hole or ring Trapezoidal Arc segments Cylindrically curved to match a focal plane PHOTONIS footer content here 26 Jan 17 Page 5

Applications for MCPs PHOTONIS CONFIDENTIAL PHOTONIS footer content here 26 Jan 17 Page 6

Mass Spectrometers Photonis MCPs are ideal for a wide range of analytical instruments, including mass spectrometers. Photonis is the leading supplier of MCPs to manufacturers of mass spectrometers across the globe. MCPs can be provided in complete electrooptic housings to facilitate assembly and service of the instrument Sizes from 4mm to 120mm Fastest TOF Detectors, including BiPolar Photonis is the world s largest manufacturer of custom MCPs Learn more about complete MCP assemblies

Scanning Electron Microscopes and Focused Ion Beams Center hole MCPs are ideal for use in Scanning Electron Microscopes (SEM) and Focused Ion Beam (FIB) applications. MCPs can use low 200v beam energy Accurate measurement and edge detection In SEM applications, Photonis detectors assist in the output of high resolution imaging through non destructive testing. In FIB systems, our detectors are used to amplify the ions and produce a large enough sample to analyze. Read more on FIB and SEM applications using MCPs

Linear Reflectron Time of Flight Mass Spectrometer Center hole MCPs are used in Linear Reflectron Time of Flight Mass Spectrometry. The laser is pulsed through the MCP s center hole, while the outer edges capture the reflected ions for measurement. MCPs can be made ultra flat (+5 micron) for up to 15% reduction in time jitter error 2 micron pore sizes increase mass resolution up to 10% US Patent number 7,141,787B2 Learn more about Time of Flight Detectors

Magnetic Sector Mass Spectrometry Rectangular MCPs can be used in Magnetic Sector Mass Spectrometry. MCPs can be made to the specification of the particular instrument to achieve the superior mass resolution. Complete plug can play assemblies can also be provided. See our array of Magnetic Sector MS products

Ion or Electron Energy Analyzers Arc shaped MCPs are ideal for ion or electron energy analyzers Detects both high and low energy ions Radius and size can be custom specified High speed and superior resolution provide accurate results for researchers and instrument designers Download our brochure on Analytical Instruments

Hemispherical Energy Analyzers Annular Ring Shaped MCPs can be used in Hemispherical Energy Analyzers The MCP can be manufactured to the size required by the instrument to most effectively capture electrons or ions MCPs can be specified to pitch and pore sizes for the most effective detection.

VUV Spectroscopy MCPs can be made to curve spherically or cylindrically to match the focal plane of an instrument Ideally suited for Vacuum Ultraviolet Spectroscopy The MCP curve can be made to match the Roland Circle Learn more about our Spectroscopy products

Large Mosaic Detectors Trapezoidal MCPs are ideal for tiling together to form a large mosaic detector. Specific angles and pitch/pore sizes can be ordered to capture the specific phenomena over a small or large area MCPs can be ordered with specific phosphor coatings or other finishing options.

ION BEAM IMAGING Ion Beam Imaging MCPs can be used to image ion beams Ideally suited for instrument designers to validate the ion path s focus and alignment within an instrument Ion beam imaging can also be used in physics research MCPs can also be mounted into electrooptic housing assemblies for plug and play operation. FIBER OPTIC PHOSPHOR SCREEN Watch our video on how ion beam imaging can improve your analytical instrument CAMERA

High Speed Sequential Imaging Stripline Microchannel Plates are used to capture extremely high speed sequential images through the use of an electrode strip manufactured on the back of each MCP. Ideal for diagnostic imaging in high speed physics research Each image can be captured as fast as the electrical charge can travel within the MCP Learn more about Stripline MCPs

Custom MCPs from Photonis Photonis is the world s largest supplier of custom Microchannel Plates Geometries, coatings, pitch/pore sizes, shapes and sizes Laser milling enables custom shapes and sizes such as arc segments, wedges or center hole Spherical or cylindrical curves can match the focal plane of a Roland circle. Sizes 2mm to 160mm Pore sizes 2µm to 25µm Photonis MCPs can be ordered with TruFlight TM ultra flat for TOF Mounting Pad TM rigid, inactive areas for mounting without cracking or bowing Extended Dynamic Range increases detection limits by a factor of ten Rimmed or Rimless With Electro Optic housings for plug and play operation Endspoiling Enhancement OAR Enhancement Enhancement Coatings: ESI KBR CUI Gold MgFe

For more information, or to consult with an applications engineer to discuss your exact requirements, please contact Photonis: PHOTONIS USA, Inc. 660 Main Street Sturbridge, MA 01566 United States of America Email: science@photonis.com Telephone: +1 508 347 4000 T +1 508 347 4000 F +1 508 347 3849 www.photonis.com