Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

Similar documents
Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

VENTS КАМ. Series CHIMNEY CENTRIFUGAL FANS

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Series VENTS VUT R WH ЕС

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Catalogue section. Contents Quick fan selection Quick selection of air handling units About us Ventilation in our life...

CENTRIFUGAL FANS user's manual. model VENTS VK.

KOMFORT EC DB Suspended heat recovery air handling units

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Turbo. Service Instructions

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

USER S MANUAL. VKP Series INLINE FAN

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Duct electric heater with temperature controller

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Duct electric heater with heating. capacity from 0.6 kw up to 2.4 kw and an integrated. temperature controller

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Description of components and operating logic of the unit MICRA Ventilation system arrangement example based on the unit MICRA 60...

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

(57.7) X. March 2006 PRODUCTS. ... the complete solution

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Centrifugal inline fans

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

Wind. Service instruction

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Mini fans MiniVent M1/100

Light, air, sound, In every space, It s how you embrace those things.

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

SMOKE CONTROL - NEW DIRECTIONS

SINGLE-ROOM VENTILATION. for schools and public spaces

HEAT RECOVERY VENTILATOR

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

BATHROOM EXTRACT FANS SILENT-100 Series

Caution: The fans must not be used in bath or shower enclosures.

SAX. Window & Wall Fans

ATC Heating Devices. P. 1 ATC Heating Devices

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

Small Room Heat Recovery Ventilation

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

RAPID RESPONSE. Quiet Operation. Powerful Performance. Header Box Exhaust Fan

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

INTELLIGENT AXIAL FAN user's manual

Domestic & Commercial Fans

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

CASSETTE UNIT. Comfort Circle

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

UNIJET CAR PARK VENTILATION SYSTEM

The Straight Way K Sileo Series

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

42AM. Air heaters PRODUCT SELECTION DATA

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

TopVent Design Handbook

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

CENTRIFUGAL CEILING EXTRACT FAN

AXIAL FANS USER S MANUAL

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Ceiling air diffuser INDULTHERM INDULTHERM-e

COMMERCIAL VENTILATION

Outside Air Requirements... SOLVED!

AC Backward Curved Motorized Impellers

Gas-fired unit heaters for indoor installation

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

JM Aerofoil Fans Bulletin JMA60-05

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER

Heat recovery unit RDKS

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Fan heater SWT Ceiling mounted fan heater with water heat

Centeral Station Air Handling Unit

TECHNICAL SPECIFICATION

Systemair product news - Fans NEWS

Transcription:

Offices Conference halls Kindergartens Libraries Restaurants Schools Sport halls Shops 2 VENTS. SOUND-INSULATED VENTILATION TT SILENT-M 5-213

WWW.VENTILATION-SYSTEM.COM «NOISY LIFE» Our life is daily filled with millions of various words, voices and sounds. We are surrounded by all kinds of sounds in the office, outside and even at home. Loud natural sounds are rare and do not last long. However, the voice of nature is hardly audible in the modern urbanized world as is often lost in industrial noises. This sound pollution has become an unwanted integral alpartofourlives our lives. Numerous investigations prove the negative effects of noise pressure on human health. Lasting exposure to acoustic waves is not only unfavourable for auditory organs, but may provoke decrease of auditory sensitivity, heart disorders, high pressure, headaches, rapid fatigability, nervous stress and other unpleasant symptoms that may lead to severe complications. We perceive sound in different ways depending on age, health state, mood and ambient conditions. As most daily time we spend at work, the labour conditions influence our acoustic apparatus most of all. The many sources of noise irritants include loud human voices, working Natural air circulation created by open windows and doors is always combined with unhealthy draughts, various smells, dust, allergens that come to the premise. But even more preferable mechanical ventilation is also associated with increased acoustic discomfort because of sounds generated by working equipment. 2-3 db is the natural noise level that is harmless for the human health and makes the natural noise background in our life. DO YOU NEED EFFICIENT SILENT VENTILATION IN YOUR ROOM? WE HAVE A SOLUTION! The latest developments in ventilation industry resulted in the invention of a totally sound-insulated casing that provides an absolutely silent fan operation. The noise level generated by the operating fan with minimum air flow does not exceed 29 db(a) and 4 db(a) at maximum air flow respectively. The noise produced by the fan is commeasurable with the natural comfortable sound level. equipment, telephone rings, outside noise that comes through open windows, etc. Comfortable job climate means not only admissible indoor noise level but also fresh permanently circulating air. Integration of sound-insulated fans into air handling units is the best solution for various premises requiring low noise ventilation, such as banks, archives, museums, kindergartens, education facilities, libraries, theatres, public institutions, record studios, etc. VENTS. SOUND-INSULATED VENTILATION TT SILENT-M 5-213 3

SOUND-INSULATED FANS Серия ВЕНТС ТТ Cайлент-М The new TT Silent-M fan is covered by a specially designed heat- and sound-insulated casing that provides low-noise operation. The fans combine wide capabilities and high performance characteristics of both axial and centrifugal fans, thus providing powerful air stream and high pressure. The fan is recommended for efficient supply and exhaust ventilation of various commercial and industrial premises with high requirements to noise level, i.e. in libraries, conference halls, educational institutions, kindergartens, etc. The fan is compatible with round air ducts from Ø up to 315 mm and produce maximum air flow 195 m 3 /h. Casing the outer casing is made of black polymer coated steel; heat and sound insulation with 5 mm mineral wool layer; the inner casing perforation let sound waves pass through the holes and fall at a specific angle to the sound-absorbing layer thus providing sound attenuation in a broad frequency band; the inner casing and the impeller are made of high-quality durable ABS plastic; the conic impeller with special blade profiling, the diffuser and the directing vanes at the casing outlet increase air flow speed and provide higher pressure and air capacity as compared to standard axial fans; power supply though the external airtight terminal box on the fan casing; the fan connecting pipes are rubber sealed for airtight connection to the air ducts. Motor single-phase energy efficient doublespeed motor with low energy demand; thermal switches ensure the motor overheating protection; extended motor service life up to 4 hrs. due to ball bearings; IPX4 ingress protection rating. Mounting mounting at any place and at any angle within the ductwork system; several fans in one system: parallel mounting to attain higher air capacity, mounting in series to boost operating pressure; fixing brackets for fastening the fan to the floor, wall or ceiling. Accessories Silencer SR (round) Panel filters FB FB 315 FBV FBV 315 Bag filters FBK FBK 315 Electric heaters NK NK 315 Water heaters NKV NKV 315 Back valves KOM KOM 315 4 VENTS. SOUND-INSULATED VENTILATION TT SILENT-M 5-213

WWW.VENTILATION-SYSTEM.COM Speed control The double-speed motors are controlled with a built-in switch («V» option) or an external switch for multi-speed fans (available upon separate order); TT Silent-M fan with a three-position speed switch A built-in speed controller («P» option), an external TRIAC or autotransformer speed controller (available upon separate order) enable smooth motor speed control when connected to the maximum speed terminal; TT Silent-M fan with a built-in speed controller «T» option models are equipped with an adjustable turn-off delay timer, adjustable from 2 to 3 minutes. The fan with electronic module of the tem perature sensor and speed controller («U» option) The front panel of the electronic module has the following controls: speed control knob for setting the motor speed; thermostat control knob for setting the tem perature set point; thermostat indicator light. TT Silent-M U fan with the electronic temperature and speed control module provides automatic control of the motor speed (air capacity) depending on the air temperature in the air duct or in the room. TT Silent-M U is available in two modifications: with a temperature sensor integrated inside the fan air duct («U/U1» option); with an external temperature sensor fixed on the cable, 4 m long («Un/U1n» option). TT Silent-M U with a with a temperature sensor integrated inside the fan air duct («U/U1» option); TT Silent-M Uwith an external temperature sensor fixed on the cable, 4 m long («Un/U1n» option). Control logic of the fan with the electronic temperature and speed control module («U» option): Set the desired air temperature (set point of the thermostat) with the thermostat control knob; Set the required minimum impeller speed (air flow) with the speed control knob; The motor switches to maximum speed (maximum air flow) as air temperature reaches and exceeds the set temperature set point. The motor switches to the pre-set lower speed as air temperature drops down below the set temperature point. To avoid the frequent motor speed changes, e.g. when the temperature in the supply air duct is equal to the threshold value, the switching delay time is activated: option 1. The temperature sensor-based switch delay («U/U1» option): the motor switches to higher speed as air temperature exceeds 2 C above the set thermostat set point. The motor revers to the pre-set lower speed as air temperature drops down below the thermostat set point. This control logic is used to keep air temperature to within 2 C. In this case the motor speed switches are rare. option 2. The timer-based switch delay (Un / U1n option): as air temperature exceeds the set thermostat set point, the motor switches to higher speed and the switch delay timer is activated for 5 min. The motor reverts to lower speed as the air temperature drops down below the thermostat set point and only after the delay timer countdown. This pattern is used for exact air temperature control. The speed switches for the fan with U1 option are more frequent as compared to the fan with U option, however the minimum operating cycle at one speed is 5 minutes. Air shutters KRA KRA 315 Clamps C C 315 CZ CZ 315 CZK CZK 315 Temperature controllers RTS-1-4 RTSD-1-4 Speed switches P2-5, Speed switches P2-1-3 Sensor speed switch SP3-1 VENTS. SOUND-INSULATED VENTILATION TT SILENT-M 5-213 5

SOUND-INSULATED FANS Technical data: TT Silent-M TT Silent-M 125 TT Silent-M 15 Speed min max min max min max Voltage [V / 5/6 Hz] 1~ 23 1~ 23 1~ 23 Power [W] 24 26 25 3 45 52 Current [A],1,11,11,13,2,23 Maximum air flow [m 3 /h] 17 24 23 34 45 555 RPM [min -1 ] 23 263 165 231 197 2645 Noise level at 3 m [dba] 24 29 23 28 26 33 Maximum operating temperature [ о C] 6 6 6 Protection rating IP X4 IP X4 IP X4 16 14 12 TT Silent-M 16 14 12 TT Silent-M 125 8 8 6 6 4 4 2 2 5 15 2 25 5 15 2 25 3 35 Hz Gen 63 125 25 5 2 4 8 L wa to inlet dba 42 19 18 29 35 39 39 31 24 LwA to outlet dba 45 2 19 3 38 42 35 35 23 L wa to environment dba 34 15 14 17 25 29 21 22 14 Hz Gen 63 125 25 5 2 4 8 L wa to inlet dba 47 19 21 35 38 42 41 35 28 LwA to outlet dba 46 21 24 35 39 41 43 37 29 L wa to environment dba 35 17 2 23 27 28 22 21 15 25 2 TT Silent-M 15 35 3 25 TT Silent-M 2 15 2 15 5 5 2 3 4 5 6 2 4 6 8 Hz Gen 63 125 25 5 2 4 8 LwA to inlet dba 61 25 33 49 55 53 55 53 39 L wa to outlet dba 59 35 36 51 55 55 55 5 42 L wa to environment dba 39 19 22 39 35 36 33 24 21 Hz Gen 63 125 25 5 2 4 8 LwA to inlet dba 62 26 38 54 57 58 55 52 48 L wa to outlet dba 65 28 42 48 62 6 62 5 44 L wa to environment dba 45 22 3 31 38 41 42 29 22 6 VENTS. SOUND-INSULATED VENTILATION TT SILENT-M 5-213

WWW.VENTILATION-SYSTEM.COM Technical data: TT Silent-M 2 TT Silent-M 25 TT Silent-M 315 Speed min max min max min max Voltage [V / 5/6 Hz] 1~ 23 1~ 23 1~ 23 Power [W] 78 11 127 178 213 313 Current [A],35,49,52,79,93 1,41 Maximum air flow [m 3 /h] 81 12 15 133 153 195 RPM [min -1 ] 215 2445 1965 2495 1975 2545 Noise level at 3 m [dba] 31 36 34 38 36 4 Maximum operating temperature [ о C] 6 6 6 Protection rating IP X4 IP X4 IP X4 5 4 TT Silent-M 25 7 6 5 TT Silent-M 315 3 4 3 2 2 2 4 6 8 12 14 5 15 2 Hz Gen 63 125 25 5 2 4 8 L wa to inlet dba 65 29 41 57 6 61 58 55 51 LwA to outlet dba 75 31 45 58 65 73 65 53 47 L wa to environment dba 55 25 33 48 41 53 49 41 29 Hz Gen 63 125 25 5 2 4 8 L wa to inlet dba 69 35 47 62 61 64 67 58 55 LwA to outlet dba 75 4 53 69 69 7 65 55 51 L wa to environment dba 58 25 32 41 51 55 52 49 37 Fan overall dimensions: Type Dimensions [mm] D B B1 L H Mass [kg] Figure no. TT Silent-M 98 215 243 55 237 4,6 1 TT Silent-M 125 123 215 243 474 237 4,6 1 TT Silent-M 15 147 247 274 58 26 6,1 1 TT Silent-M 2 198 293 386 55 295 8, 2 TT Silent-M 25 248 358 445 658 36 15, 2 TT Silent-M 315 313 432 52 78 434 25, 2 Fig.1 Fig.2 VENTS. SOUND-INSULATED VENTILATION TT SILENT-M 5-213 7

SOUND-INSULATED VENTS TT SILENT-M FAN VENTS reserves the rights to modify any of its products features, designs, components and specifications at any time and without notice to maintain the development and quality of manufactured goods. 5/213