CO2Sensor Basic / ES 999

Similar documents
WM3000 WIRELESS MODULES

Exit Stopper. STI-6400 Series

ACL TC 200 TEMPERATURE CONTROLLER

Power Supply Display Module PSDM. Installation and Operation Manual

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

PTE0705 Electric Fence Monitor

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

Honeywell ENERGY SAVINGS KIT

Exit Stopper. STI-6400 Series

Operating Instructions. For. Alarm Control Module. Model SSR 500

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Addendum for STI-6406 with Dual Access Control

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Installation guide for J4 Junction Box for R4 AIS Transponder System

Model 4001 Series Single Channel Controller

Interface Modules for SENTRI

Owner's Manual AURATON 3013 для программного обеспечения вер. F0F

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

HTC-915-CONT. Heat-Trace Control system

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

ETN24-P/PD-FC-SUPER2. Owner's Manual - Installation and Operating Instructions

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

Duct and Rough Service Carbon Monoxide Sensor

N M AirControl AHU. Control manual

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

AIS750 Series Alarm Annunciator

Engineering Guideline. pac- Carriers Type Universal

KM300 Carbon Monoxide Detection System Installation Manual

CR Series Command Relays

Refrigerant Leak Detector Manual

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

ORION-PL Poultry computer for cage houses

English. Series. Installation and Use Manual

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

ACS-30-EU-EMDR- 10-MOD

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

PolyGard 2-channel Gas Controller MGC-03

OVEN INDUSTRIES, INC.

Door Release Power Supply

HARDwired Installation/ Owner s Manual

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

Carbon Monoxide (CO) detection system

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Ammonia Leak Detector Manual

Natural Ventilation Controller with 24vDC drive NVC-1204

Networkable Fan Coil Controller Specification and Installation Instructions

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Gas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

E340 BOILER CONTROL INSTALLATION MANUAL

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Oxygen (O2) Single-Point Gas Detection System

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

T7984 A,B,C Electronic Modulating Control Thermostats

Carbon Monoxide CO Transmitter ADT-X3-1110

Kædemotorer. Accessories

OPERATION AND ALARM PANELS

/8 DIN Level Indicator

1. Product description

Dissolved Oxygen Measurement liquisys M COM 223 / 253

ACCESSOIRES ELECTRICAL ACCESSORIES

APPLICATION DATA SHEET

Model A1600 Series Annunciator

Natural Ventilation Controller with 24vDC drive NVC-1204

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

KT-100 Door Controller

Plug-in Base, Long Range Sensor E3B2

RAM3 Remote Alarm Module

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

WIO 200B and WIOI200B Water in oil sensor

Allure EC-Smart-Air Series Communicating sensors

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

Sensor Interface Module Installation/Operation Instructions

Water Detection Controllers

HOME AUTOMATION GUIDE TO THE HOME AUTOMATION SYSTEM

DESCRIPTION. 42 mm. 125 mm

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

INTREPID Perimeter Intrusion Detection System

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

User manual. KNXgal. version

Control equipment. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax.

Transcription:

CO2Sensor Basic / ES 999 CO2 sensor Sensor for ventilation plant for increased comfort Optional accessories: External power supply with set-point relay MultiController E -1% MultiController E Regulate

Properties: ES 999 is to be used as sensor for controlling ventilation according to CO2 level in single rooms or in more complicated ventilation systems. ES 999 is provided with a -1V proportional output based on the current CO2 level,which is used as input for a regulator or ventilation plant. Both design and ease-of-use have been prioritised: Easy mounting and installation. Maintenance free. Discreet sensor ideal for mounting in households and office environments. Input signal for controlling ventilation plant based on CO2 level. To be used only as CO2 measurer. Functionality: ES 999 measures the CO2 level in the room and translates the measurement to a proportional -1V output. ES 999 can also be used as ON/OFF controller in combination with external -1V set-point relay. Power supply ES 963 is designet for use with the CO2 sensor and has a built-in set-point relay. CO2 proportional output: The voltage varies proportionally with the CO2 level between and 1V corresponding to and 2 ppm. Mounting / installation: Supply: Supply is connected to the clamps marked og for DC or og for AC. CO2 level: The output signal is polarized and should therefore be connected correctly as shown on the drawing and on the marking on the clamps terminal. T Page 2

Connection diagram Front Rear Output 4 5 6 Co2 level -1V T T DC AC 2 { } Supply 1 3 Page 3

Connection diagram for regulator and modulating damper: ES 999 CO2 sensor Jumper 13 14 15 16 17 18 19 2 21 SD Card 9 1 11 12 RTS 8 RX 7 TX 6 5-1V in 4 3-1V in 2-1V out 1-1V out ES 874 MultiController E Regulate 24 23 22 } Power 6 NTC2 NTC 1 5-1V 4 RS 485A { 3 RS 485B Output 2 V out V in Supply 1 Modulating damper 24V AC/DC _l Important: The unit is intended for mounting in the supplied base. Alternative mounting may influence the function of the CO2 sensor. To be connected in accordance with the current low voltage directive. The suggested regulator is also available for 23V AC supply (ES 974), please consult the appropriate instructions for mounting. Page 4

Connection diagram for on/off damper: ES 999 Set-pointt 24VDC -1V input Max Supply Output { JP 1 NC COM CO2 sensor } Min ES 963 Power supply with set-point relay NO -1V 1VDC out -1Vi input T1.6A On-off damper L N 23V AC { On/off Supply External supply Important: The unit is intended for mounting in the supplied base. Alternative mounting may influence the function of the CO2 sensor. To be connected in accordance with the current low voltage directive. Page 5

Accessories for ES 999: ES 963 External Power supply with set-point relay. Complete power supply for ES 999 which is capable of supplying one sensor. For connection to 23V AC with 24V DC 3VA output voltage. The design matches the ES 999 elegant style of enclosure. In addtion the ES 963 has a built in set-point relay which provides the possibilty of an on/off function. Page 6

Notes:

Technical data: Supply: DC: 24V ±1% 3VA AC: 24V ±1% 6,4VA Operating temperature: 1-5 C Measuring range CO2 sensor: Accuracy CO2 sensor: - 2ppm ±5ppm ved 5ppm CO2 proportional output: - 1V 15mA Maintenance free when used in households and office environments. Enclosure: Dimensions (HxBxD): IP 21 85 x 85 x 35 mm WEEE Electrical and electronic equipment contains material which may be hazardous to human health and environment if it is not handled correctly at disposal. Electrical and electronic equipment is marked with a crossed-out wheelie bin logo. This logo symbolises that electrical and electronic equipment should not be disposed of together with normal household waste but must be collected separately. Contact your local suthorities for further information on disposal of equipment under the WEEE directive The product complies with the following standard EN 673-1 Date: 13-2-213 Drawing: 95-25654_CO2SensorBasic_ES999_EN Drawn by: FF-DF Rev.: 1. Manufactured by: LS Control A/S lsc@lscontrol.dk tel. 45 555 555 fax 45 555 2265 www.lscontrol.com