OMA-300 Process Analyzer

Similar documents
APPLIED. OMA-406R Rackmount Process Analyzer

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Features and Benefits

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

An FT-NIR Primer. NR800-A-006

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Enraf Servo Gauge 854 ATG

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Specifications Wavelength Range: 190 nm to 800 nm continuous

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Features and Benefits

PUV, PIR and PFO Series BROCHURE

detectors UltiMate 3000 Variable Wavelength Detectors

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Enraf Servo Gauge 854 XTG

The SharpEye 40/40I (IR3) Flame Detection

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Dräger Polytron 8720 IR Detection of carbon dioxide

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Dräger Polytron 8100 EC Detection of toxic gases and vapors

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Eliminating False Alarms in Toxic Gas Detection. Jason Schexnayder Sales Manager - Americas

Ronan Model X96S Series Weighing System

Technical Information OUSAF12

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Dräger Polytron 8700 IR Detection of flammable gases and vapors

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

WASTEWATER Online UV%Transmission Analyzer

The SharpEye 40/40M (Multi IR) Flame Detection

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Dräger PointGard 2100 Detection of toxic gases and vapours

Technical Information OUSAF21

Dräger Polytron 8310 Stationary gas detector (DSIR)

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Technical Information OUSAF22

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Dräger Polytron 5720 IR Toxic Gas Detection

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Dräger Polytron 5100 EC Detection of toxic gases and vapors

The SharpEye 40/40I (IR3) Flame Detection

Technical Information OUSAF44

Dräger Polytron 5720 IR Detection of carbon dioxide

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Ronan Model X96S Series Density System

APPLICATION DATA SHEET

for Drinking Water Systems

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger REGARD 3900 Series Control System

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger GS01 (wireless) Detection of flammable gases and vapours

Autocalibration Systems for In Situ Oxygen Analyzers

Rosemount 3490 Series

Dräger Polytron 8000 Stationary gas detector (EC)

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

The SharpEye 40/40R (IR) Flame Detection

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Dräger Polytron Pulsar 2 Open Path Gas Detector

Technical Information OUSTF10

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

InfraSpec NR800. FT-NIR Analyzer. Bulletin12Y03A03-01E

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Dräger Polytron 8200 Stationary gas detector (CatEx)

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Effluent Monitoring. Solutions

Flame Monitors BROCHURE

FM Approved Fire & Gas Detection System

Flame Detection Jon Sarfas

APPLICATION DATA SHEET

SPECTRAL INSTRUMENTATION

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Turbimax CUE21 / CUE22

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Technical Information OUSTF10

Zircomat Oxygen Analyzers

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

IR 3000 WBPi Online Moisture Measurement with Infrared Technology

Series 5000 Hydrazine Analyzer Model 60002

Industrial Grade Gas Detection

SUNSTAR 传感与控制 TEL: FAX: DATASHEET Lightingg Solutions 1100 Series High Stabi

Rosemount 2051T In-Line Pressure Transmitter

A New Standard of Excellence

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Transcription:

A window into your process since 1994. The OMA Process Analyzer continuously measures chemical concentrations and physical properties that can be correlated from the 200-1100 nm (UV-Vis / SW-NIR) absorbance spectrum. Model OMA-300 deploys the OMA design in the standard wall-mounted enclosure format. Features Continuously measures up to 5 chemicals concentrations in a liquid or gas process stream Totally solid state build with no moving parts modern design for low maintenance Ultra-safe fiber optic design with dedicated sample flow cell no sample fluid in analyzer enclosure Decades of field-proven performance in the world s harshest industrial environments [1]

Optical Assembly & Principle of Operation light source holographic grating fiber optic cables flow cell diode array o-ring collimator The OMA measurement cycle is virtually instantaneous, but it can be helpful to visualize it in stages: (1) The white light signal originates in the pulsed Xe lamp that functions as the light source. (2) The signal travels via fiber optic cable to the flow cell. A collimator narrows the light beam. (3) The signal travels directly across the flow cell, interacting with the continuously drawn process sample. (4) The signal exits the flow cell through a collimator, now containing the distinct absorbance imprint of the current chemical composition of the sample. (5) The signal travels via fiber optic cable to the spectrophotometer. (6) The signal is dispersed by the holographic grating. Each differentiated wavelength is focused onto a designated photodiode within the diode array. (7) The absorbance spectrum is measured by plotting the lost light intensity at each wavelength: Normalized Light Intensity Spectrum Visualized Absorbance Spectrum (1% H 2 S) light intensity Thru N 2 Thru 1% H 2 S >> absorbance (AU) 1.4 1.0 0.6 0.2 215 225 235 245 255 wavelength (nm) 215 225 235 245 255 wavelength (nm) [2]

OMA Internal Components human machine interface (HMI) I/O board power supplies nova II spectrophotometer circuit breakers ECLIPSE Software User Interface Normal Runtime: Real-time concentration data is displayed on the home screen. Auto Zero: Runs on custom schedule to normalize the spectrophotometer readings on zero-absorbance fluid. [3]

OMA-300 Technical Drawing [4]

All performance specifications are subject to the assumption that the sample conditioning system and unit installation are approved by Applied Analytics. For any other arrangement, please inquire directly with Sales. Subject to modifications. Specified product characteristics and technical data do not serve as guarantee declarations. Technical Data General Measurement Principle Detector Spectral Range Light Source Dispersive UV-Vis / SW-NIR absorbance spectrophotometry nova II Spectrophotometer Data sheet: http://aai.solutions/documents/aa_ds201a_novaii.pdf 200-800 nm (UV-Vis model) or 400-1100 nm (SW-NIR model) Standard: pulsed xenon lamp with average 5 year lifespan (dependent on application) Fiber Optic Cables Standard: 600 μm core 1.8 meter fiber optic cables (qty = 2) Data sheet: http://aai.solutions/documents/aa_ds206a_fiberoptics.pdf Sample Medium Gas or liquid Sample Introduction Standard: stainless steel 316L flow cell with application-dependent path length Options in data sheet: http://aai.solutions/documents/aa_ds207x_flowcell_all.pdf Sample Conditioning Custom design if necessary Analyzer Calibration If possible, analyzer is factory calibrated with certified calibration fluids; no re-calibration required after initial calibration; measurement normalized by Auto Zero Reading Verification Simple verification with samples and self-check diagnostic Human Machine Interface Applied Analytics standard HMI: industrial controller with touch-screen LCD display Data sheet: http://aai.solutions/documents/aa_ds202a_hmi.pdf User Interface ECLIPSE Runtime Software Data sheet: http://aai.solutions/documents/aa_ds203a_eclipse.pdf Data Storage Data Storage Solid State Drive Data sheet: http://aai.solutions/documents/aa_ds203a_eclipse.pdf Enclosure Standard: wall-mounted, carbon steel NEMA 4 enclosure Options in data sheet: http://aai.solutions/documents/aa_ds401x_enclosures.pdf Available Certifications Standard: General Purpose Available Options: ATEX, IECEx, EAC Please inquire with your sales representative for additional certifications (CSA, FM etc.). Measuring Parameters Photometric Accuracy ±0.004 AU at 220 nm Response Time 1-5 seconds Sensitivity ±0.1 % full scale Sample Conditions Sample Temperature Standard: -20 to 70 C (-4 to 158 F) Optional: up to 150 C (302 F) with cooling extensions Contact AAI for temperatures above 150 C (302 F) Sample Pressure (max) Using immersion probe: 100 bar (1470 psig) Using standard flow cell: 206 bar (3000 psi) [5]

Revised 06 July 2017 Ambient Conditions Analyzer Environment Indoor/Outdoor (no shelter required) Ambient Temperature Standard: 0 to 35 C (32 to 95 F) Optional: -20 to 55 C (-4 to 131 F) To avoid radiational heating, use of a sunshade is recommended for systems installed in direct sunlight. Physical Specifications Dimensions Analyzer: 24 H x 20 W x 8 D (610mm H x 508mm W x 203mm D) SCS (if included): custom size Weight Analyzer: 32 lbs. (15 kg) SCS (if included): variable depending on custom build Wetted Materials Standard: K7 glass, Viton, stainless steel 316L Various custom materials available please inquire. Utility Requirements Electrical Requirements 85 to 264 VAC 47 to 63 Hz Power Consumption 45 watts Outputs/Communication Outputs 1x galvanically isolated 4-20mA analog output per measured analyte 2x digital outputs for fault and SCS control Optional: Modbus TCP/IP; RS-232; RS-485; Fieldbus; Profibus; HART; more I/O Electronics Voltage/Current Interface Module (i.e. I/O Board) Data sheet: http://aai.solutions/documents/aa_ds205a_vcim.pdf is a registered trademark of Applied Analytics, Inc. www.aai.solutions Headquarters Applied Analytics, Inc. Burlington, MA sales@aai.solutions North America Sales Applied Analytics North America, Ltd. Houston, TX sales@appliedanalytics.us Asia Pacific Sales Applied Analytics Asia Pte. Ltd. Singapore sales@appliedanalytics.com.sg Middle East Sales Applied Analytics Oil & Gas Operations, L.L.C. Abu Dhabi, UAE sales@appliedanalytics.ae India Sales Applied Analytics (India) Pte. Ltd. Mumbai, India sales@appliedanalytics.in Europe Sales Applied Analytics Europe, AG Genève, Switzerland sales@appliedanalytics.eu Brazil Sales Applied Analytics do Brasil Rio de Janeiro, Brazil vendas@aadbl.com.br 2017 Applied Analytics, Inc. Products or references stated may be trademarks or registered trademarks of their respective owners. All rights reserved. We reserve the right to make technical changes or modify this document without prior notice. Regarding purchase orders, agreed-upon details shall prevail. [6]