Space Saver. New Easy Guide. Connecting your Space Saver to a central heating system BEFORE AFTER

Similar documents
Space Saver. New easy guide. Connecting your Space Saver to a central heating system. Issue 001 February 2018 ENGLISH UK IRL SmithsEP.co.

Hydroflame. Flame-effect fan convectors Installation and User Guide Elite and Classic Models. Contents

Signature, Sovereign, Sentry, Sentinel, Staccato Fan-Assisted Radiator. Installation & User Guide

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Sargasso Range. Installation manual. Sargasso S. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

Sargasso Range. Installation manual. Sargasso A. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

VD 3401 Chauffage central Installation, Operating, Maintenance and After Sales Manual

INSTALLATION & TECHNICAL MANUAL

Bar valve with fixed and adjustable shower heads. Installation guide. Midas Plus installation instructions Page 1

AQ150:Midas 10/9/15 14:50 Page 1 AQ150. Thermostatic bar mixer valve with adjustable head. Installation guide

SEALED THERMAL STORE

INSTALLATION & TECHNICAL MANUAL

Sargasso Range. A new range of radiant panels for heating commercial applications

ADVANCE ECB ELECTRIC COMBINATION BOILER

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

Aegean Range. A new range of fan coils for heating and cooling commercial applications

Turboboost SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Enzo Concealed Shower Mixing Valve

Thermostatic bar mixer valve with adjustable head Installation guide

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

Assessment Schedule - TS.6

Kiko Concealed Shower Mixing Valve KK80010CP

INTA ION MODERN BAR / BATH SHOWER MIXER CP

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

KICKSPACE 500, 600, V & 800

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

ferroli Boiler Replacement Maxima 35C- Modena HE

Hydroflame Patented. 1 of 5. Domestic Applications. Inset Elite Brass. Freestanding Classic Brass. Freestanding Elite Brass

Kiko Bath Shower Mixing Valve KK90015CP

MEGAFLO HE Iss 1

Inta City Shower Mixing Valve CT20010CP

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

INSTALLATION AND QUICK COMMISSIONING INSTRUCTIONS EWC WARM WATER TIME CLOCK WATER SOFTENERS

Installation Instructions Flute Tap Range

Deluge Shower Mixing Valve 10045CP

Puro Mini Dual Control Shower Mixer PU90010CP

How to keep your home safe and dry. Start here

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

Alpha CombiMax 350 and 600

MBSY110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Enzo Safe Touch Thermostatic Shower EZ20011CP & EZ20012CP

Plus Bath Shower Mixing Valve CP and PL30020CP

INTADUO THERMOSTATIC BATH/SHOWER MIXER

Mio Concealed Shower Mixing Valve MI40010CP

METRO BATH FILLER MOUNTED CHR

warm water underfloor heating installation manual v4b-aug 08 Nu-Heat design innovation expertise service

PERFORMANCE SHOWER PRODUCTS

Inta City Concealed Shower Mixing Valve CT80010CP

Deluge Concealed Shower Mixing Valve DL40010CP

Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation

Fusion 200, 300 & 500

CPC-150-ABIAB. Important Installation Notes.

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Greenstar System Filter

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

METRO BASIN MONO MIXER CHR

Telo Shower Mixing Valve TL10016CP

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

Beautifully Traditional

Underfloor Heating Installation Guide

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted

Manual and Thermostatic Power Shower Units

Your Central Heating System

Infra Red Thermostatic Wall Mixer

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

Link-Up. Solid Fuel Association Guide to Central Heating.

WHISPA III 5000, 7000 & Installation, Operating, Maintenance and After Sales Manual. Tested to UL & CSA Standards. Part Number: Issue 1

Please take time to carefully read through these guidelines before using your Kamco pump.

Surface Temperature Tests on an LST Fan Convector

Bosch Group. 24CDi OF WALL MOUNTED COMBINATION BOILER FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

HEAVY DUTY BRASS SHOWER PUMPS

Jetflush 4 Instruction Manual

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Kamco. Issue: March 2008 Section C FAQ about Power Flushing Page C.1 SECTION C FREQUENTLY ASKED QUESTIONS ABOUT POWER FLUSHING

CalMag Heating Pack Installation Instructions

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

Grohtherm Wireless! Installation Instructions Pumped High Pressure

T550i power shower pump Installation and operating instructions

HW3 Handwash Installation and Operating Instructions

Combi Konverter Solar System

Understand and apply domestic central heating system installation and maintenance techniques

Transcription:

Space Saver Connecting your Space Saver to a central heating system BEFORE New Easy Guide AFTER

Space Saver Introduction This document is intended as an easy step-by-step guide to connecting your Smith's Space Saver plinth heater to your central heating system. It is aimed at those who are typically replacing a panel radiator or connecting to an existing central heating system. We hope it offers an invaluable resource to both professional installers and competent DIY'ers alike. It will show you what heating systems are suitable for Space Saver, how to connect your unit to your existing system and help you get the best performance from your heater. This guide is intended to be read in conjunction with the Installation and User Guide provided with the product. We would stress that should you have any doubts regarding connection of our product to the central heating system you should consult a professional. Details of a local qualified installer can be found by contacting the Institute of Plumbing and Heating Engineering on 01708 472791 or visit their Website on www.iphe.org.uk How Does It Work? Space Saver is connected to your existing central heating system pipework. Hot water passes through the unit and transfers the heat to aluminium fins. Cooler air is drawn in by an electric fan and heated as it passes through the aluminium fins, and then is gently blown back into the room via a low level grille. This not only gives a more even temperature spread, but will heat the room up in less than half the time of a traditional panel radiator. Space Saver Dual models have an additional electric heating element to allow the unit to produce heat when the central heating system is switched off. Only models designated 12V are suitable for use in bathrooms and other high humidity areas. Space Saver grille - available in a large range of finishes Heat exchanger 2

Is Your Central Heating System Suitable? Nearly all central heating systems, including micro-bore, are suitable for the installation of a Space Saver heater. The only exception is a onepipe system (see diagram below), which has been little used since the sixties and early seventies. Please note, adding micro-bore pipework to an existing small bore (15mm) system is not suitable. The diagrams below will help you identify your central heating system. ONE PIPE OPEN VENTED Gravity fed hot water pumped heating TWO PIPE OPEN VENTED Gravity fed hot water pumped heating TWO PIPE OPEN VENTED FULLY PUMPED TWO PIPE SEALED SYSTEM 3

Space Saver COMBINATION BOILER Combination boiler control panel If you have a sealed system or combination boiler it's best to locate the pressure gauge and filling loop which are usually located next to each other. You will also need the manufacturer's recommended system pressure information for when you come to refill the system. If you are replacing a radiator within a micro-bore system, you can connect to the existing pipework. If you are adding to the system, the flow and return pipes should only be connected to spare outlets on the manifold. OPEN VENTED MICROBORE SEALED MICROBORE 4

Connecting your Space Saver to the Central Heating System Read this guide in conjunction with the Installation & User Guide provided with the product. Copies are available from the download centre on www.smiths-env.com or by calling us on 01245 324560. Before beginning please ensure you read all the safety and guidance notes within the Installation & User Guide. You should now have identified your heating system and whether it is suitable to incorporate a Space Saver heater. Your next step is to drain the system of water (see page 6) to enable you to cut into the pipe work at the proposed location of the Space Saver unit. A B Positioning Space Saver Space Saver is primarily designed for installation in the space beneath kitchen/utility room units, behind the plinth. However, Spacer Saver can also be installed in other locations such as stair risers and built-in furniture. Only 12 volt models can be used in bathrooms and other high humidity areas. Space Saver can be fitted directly onto the floor (diag A) or raised in a plinth (diag B). If raised, the product should be placed on a stable level platform. Cut the plinth as described in the Installation & User Guide. Positioning the Fused Spur Now is a good time to work out the best position for the electrical fused spur. Safety regulations require that the fused spur must not be positioned directly above the heater and be easily accessible once installation is complete. Be careful, when placing inside a cupboard, that objects can't hit the switch accidentally. Positioning the Pipework The heater connects to your existing heating system's flow and return pipes. If you are unsure what these pipes are, or of the system you have, then refer to the system diagrams on pages 3 of this guide. System flow and return pipes to the heater must, where possible, be at the same level or below the heater's own flow and return pipes. This will reduce the risk of air traps. If this cannot be avoided, ensure that a finger vent is fitted allowing any air traps to be vented. 5

Space Saver Draining the System 1.Turn off the electric isolation switch normally adjacent to the boiler. 2.If you have an open vented system turn off the mains water supply to the feed and expansion tank. The stopcock valve is normally located near the tank. If there is no stopcock valve tie the ball cock (float arm) in the up position using a batten to keep the valve closed. 3.Attach a length of hose to the main draincock, usually located on the return pipe near the boiler. Place the other end of the hose to a suitable drain. Open the draincock with a key or adjustable spanner and the system will start to drain. 4.Water may be held in the radiators due to the vacuum that is created. To release the water, work from the highest radiator down and open the bleed valves on each radiator to release the trapped air. 5.Close the bleed valves and the water will continue to drain from the system. 6.Lastly drain any inverted pipe loops. Pipes are often run through ceiling voids and drop down walls to individual radiators. This is called an inverted pipe loop. Each loop should have its own draincock. It is only necessary to drain the inverted loop you are working on. Connecting the Space Saver 1.Cut and prepare the pipework and connect the heater as detailed in the Installation & User Guide. Refilling the Heating System Important We recommend the use of central heating protectors as these provide long term protection of domestic central heating systems against internal corrosion. If your system has been treated with a central heating protector you should refer to the manufacturer s instructions for topping up and refilling your heating system. Information regarding previous treatment may be with your heating system installation and user guides, on a label near the boiler or if fitted, on a label near the feed and expansion tank. Untreated systems must be thoroughly cleansed and flushed before treating as existing debris can damage the installation. If in doubt seek professional advice. 1.First check that you have closed all the draincocks and radiator bleed valves. 2.Turn on the supply to your system. If you have an open vented system turn on the valve to the expansion tanks or untie the ballcock. If you have a sealed system your system feed will most likely be located at the boiler. 6

3.In an open vented system the water will stop filling the expansion tank when the system is full. In a sealed system the system is full when you reach the required pressure as recommended by your boiler manufacturer. 4.As the system fills up air will be trapped in the top of the radiators. You will have to bleed each one, this time starting from the lowest level radiator and working upward. You may also have to bleed the circulating pump. 5.As you bleed the air out of the radiators it will need to be replaced by water. In an open vented system this will be fed automatically, but in a sealed system you will have to let more water in to keep the pressure at the correct level. It's a good idea to have two people during this procedure, one bleeding the radiators and one topping up the water. 6.Check all draincocks and bleed valves for signs of leakage and tighten if necessary. Completing the Installation 1.Refer to the Installation and User Guide to complete the commissioning of your Space Saver. Balancing the Central Heating System The balancing of the system should be carried out by a qualified person; the following notes are for guidance only. The balance of your central heating should not be affected by installing a Space Saver as part of the system. If however you get little or no heat output from the Space Saver heater it may be that the balance of the system was not correct prior to the installation. Prior to balancing, you should: a. Check the power supply is switched ON. b. If fitted, ensure the room thermostat is calling for heat. c. Increase the boiler water temperature. Lockshield! valve The purpose of balancing is to achieve equal heat distribution and heat output across all heat emitters (radiators, etc) on your central heating system. Generally, upstairs radiators get hotter quickest because hot water is lighter than cold water and so naturally rises. Consequently, radiators that are farthest from the boiler, and those at the lowest level, will need a larger volume of hot water. To achieve the correct balance, it is necessary to restrict the flow of water through each radiator by adjusting the lockshield valve. For best results, the temperature of water leaving the radiator should be 10% lower than that of the water entering the radiator. This will ensure maximum efficiency and give a longer life to the boiler. The Space Saver within your system does not need balancing but you should ensure the isolating valves supplied are fully open. Thermostatic! or wheelhead! valve 7

Smith s Environmental Products Ltd, Blackall Industrial Estate, South Woodham Ferrers, Chelmsford, Essex, CM3 5UW Tel: 01245 324900 Fax: 01245 324422 Sales E-mail: sales@smiths-env.com General Information E-mail: info@smiths-env.com Web: www: smiths-env.com For the Republic of Ireland, contact MT Agencies (Ireland) Ltd on Tel: 01 864 3363 As part of the policy of continuous product improvement, Smith s Environmental Products Ltd reserves the right to alter specification without prior notice.