AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Similar documents
Double Skin Casing Air Handling Units

AIR HANDLER SPECIFICATION

Centeral Station Air Handling Unit

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Series 2 FS 100 HM Q S AH D on innovative. a full green. meeting. line features. Page No Introduction a high unit is. Air Handling Units

TYPICAL CPA SPECIFICATIONS

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Double Skin Air Handling Units

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

1.1 This section applies to air handling units for HVAC Systems.

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

SECTION AIR HANDLING UNIT

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

XeteX, Inc. All Rights Reserved.

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

AIR HANDLING UNITS. Revision AG 16-07

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Double Skin Air Handling Units

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

Indoor Air Quality. For assured. Double Skin Air Handling Units

EHH SERIES DRAW THROUGH FAN COILS CFM

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

39G Air Handling Unit

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Direct Fired Heater Model AD Specification

DIVISION 15 MECHANICAL

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Modular Supply Make-Up Air Unit

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

AIR HANDLING UNIT AWAL GULF AIR CONDITIONING & REFRIGERATION PVT. LTD.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

ALL PRODUCTS BROCHURE

TECAM S.A. Environmental Technology

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

Cultivator & Hybrid Cultivator

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Central Station Air Handlers

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

ENGINEERING & SERVICE

Chilled Water DOAS Fan Powered Terminal Units

KIC Air Curtains. Technical Guide

62DA,DB,DC,DD,DE,DF07-38

THE ULTIMATE ROOFTOP SOLUTION

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Modular Air Handling Unit

SSL & SBS Engineering Guide

MLR SERIES MODULAR AIR HANDLING UNITS

YMA Custom Air Handling Units

Air Handling Units. T F E.

Modular Heating & Ventilating Unit Model IGX-HV

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Energy Recovery with Cooling and Heating

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

RGE 13 A T - 1 A

Indirect Gas-Fired Make-Up Air

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

3.0 Factory packaged or modular constructed AHUs, when approved for use, shall conform to the following criteria:

A. Codes and Standards that are Standard at the University:

Double Skin Air Handling Units

Air Handling Units. Real HVACR people who understand your needs.

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Contents INDEX. TDM Series Indirect Fired Heaters

Product Specifications. Vertical Floor Consoles By First Co.

SECTION AIR COILS

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

University of Delaware

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

PRODUCT CATALOG BLOWER COILS.

Classic Series AIR HANDLING UNIT. Range 1000 CFM to CFM 472 L/s to 9440 L/s

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

AIR HANDLING UNITS MANDÍK

R22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

We make air handling technology. Better.

SECTION CUSTOM FAN WALL AIR HANDLING UNITS

Submittal Transmittal

Tulsa, OK Longview, TX

DIVISION 23 - HVAC HVAC Air Distribution

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Advance Release September 2009

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

SECTION CENTRAL HVAC EQUIPMENT

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

MERIT Series R-410A - Upflow / Horizontal

American.

Transcription:

AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT)

CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory Sections 6. RT Roof Mounted Air Handlers 7. Selection Program Electronic Catalog (SPEC 7) 8. Air Handlers for Special Applications

1. CS3 AL Frame AHU : Unit Types Available casing thickness: nominal 1 & 2 1. Horizontal Wide range of sizes 1 Casing: Nom. CFM 1,200 24,000 2 Casing: Nom. CFM 1,200 52,000 2. Vertical Small footprint for maximum space utilization 1 Casing: Nom. CFM 1,200 15,000 2 Casing: Nom. CFM 1,200 24,000 3. Multi-Zone Blow Through Dampers blend hot- and cold-deck temperatures to produce a desired temperature for individual zone 1 Casing: Nom. CFM 2,200 15,000 2 Casing: Nom. CFM 2,200 24,000

1. CS3 AL Frame AHU : Certification The CS3 range is : AHRI 430 certified for 50Hz & 60Hz models ETL listed for 60Hz models

2. Casing Structure Manufactured from extruded aluminium profile with strong nylon corners Double skin sandwich panel injected with polyurethane foam (PU) of 40kg/m 3 density, giving smooth inner surfaces for easy cleaning. Internal joints are insulated with rigid PVC strip and PE foam to provide air-tight casing and minimize cold bridging. External panels are coated with powder paint to provide excellent finish and corrosion resistance Aluminium frame results in lighter Unit Casing Weight. Rigid PVC Strip

2. Casing Structure Modular Design Total MODULAR design casing gives complete unit arrangement flexibility Shipping options available of single-piece shipment or shipment in sections Can also be separated to knock-down form (CKD) for shipment Sample Unit, AHD64: (Mixing Box+ Flat & Bag Filter Sections) (Coil + Fan Sections) Module length 1 = 3+3 = 6 Module length 2 = 4+5 = 9

2. Casing Structure Modular Design Total MODULAR design, 1M = 200mm Sample calculation of unit size Unit height = (5 x 200)+ 50 + 100 = 1150mm (includes unit base) Unit width = (10 x 200)+ 50 = 2050mm Unit length 1 = (6 x 200)+ 50 = 1250mm Unit length 2 = (9 x 200)+ 50 = 1850mm

2. Casing Structure - Access Access panels are easily removable by air tight screwed compression latch. Lift-up type and hinged-type access doors are also available Hinge Air tight screwed compression latch

2. Casing Structure Section Joining Site Assembly All modular sections are supplied with joining brackets Easy alignment at site and locked together with factory supplied bolts and nuts GASKET SECTION SECTION

3. Blowers and Drives Two types of DIDW centrifugal fans available which are AMCA certified Forward Curved Fan Airfoil Fan Choice for Class I/II blowers to meet required conditions Forward Curved Fan Suitable for low to medium pressure airhandling applications Advantages: low cost, low speed Airfoil Fan Suitable for higher static pressure applications Advantages: high efficiency, stronger structure

3. Blowers and Drives - Assembly Complete assembly of fan, motor and drive is mounted on a common base with internally mounted vibration isolators (rubber or spring according to model size) Standard TEFC motors with class F insulation (IEC or Nema) Fire retardant flexible duct connector is provided to minimize transmission of vibration to unit casing Rigid shipping brackets installed to prevent damage during shipping Flexible connection All blowers are statically and dynamically balanced. After complete assembly the wheel is balanced to the lower vibration Shipping bracket Rubber of Spring isolators

4. Coils Corrugated fins and staggered tube configuration Full collar aluminum fins bonded to seamless copper tubes by mechanical expansion Fin material options: Aluminium, Copper or Hydrophilic type Counter flow arrangement Coils(5/8 tube dia, Type 5) are certified in accordance with AHRI Standard 410

4. Coils - Construction Galvanized steel casing Steel pipe header, optional copper header MBSP threaded connection, optional MNPT Plugged vent on each header Suitable for 250 psig working pressure. Tested under water with 350 psig air pressure. Other coil options, DX coils Steam coils

4. Coils Drain Pan galvanized steel sheet with powder painted V-shaped designed to provide positive pitch toward drain outlet and will not retain condensate within the pan. Minimize mold and bacteria growth Drain pipe of 1-1/2 MBSP as standard, optional for MNPT Stainless steel drain pan as optional

5. Options and Accessory Sections AHU may consist of a number of factory fabricated sections assembled in a variety of arrangements Mixing Box Section Flat & Bag Filter Section Coil Section Blower Section

5. Options and Accessory Sections Mixing Box Designed for efficient mixing of outside and return air by means of inter-connected dampers, motorized actuator as options Standard aluminium airfoil low leak dampers

5. Options and Accessory Sections - Filters Required for the removal of contaminants from the outside as well as the recirculated air Sections in flat, angle, bag filter arrangements Various filtration types. Different efficiency range to accommodate for different applications Disposable prefilter Rigid secondary filter Bag filter HEPA filter

5.4 Moisture Eliminator 5. Options and Accessory Sections Moisture Eliminator Normally installed downstream of a humidifier or cooling coil To remove droplets of water which might be entrained in the air stream due to high coil face velocity (>550 FPM)

5.5 Silencer 5. Options and Accessory Sections Silencer Slide 19 Installed at either upstream or downstream of blower section Consist multiple silencer splitters containing perforated metal baffles filled with sound absorbing material Provided to reduce noise transmission

6. RT Roof Mounted Air Handlers Designed specifically for rooftop installation Single piece modular design with model sizes handling 2,000 28,800CFM Features Top pitched roofing design Weatherproof cabinet construction Unit base rail construction for roof curb installation

6. RT Roof Mounted Air Handlers - Certification The RT range is : AHRI 430 certified ETL listed

6. RT Roof Mounted Air Handlers Top Pitched Roofing Raised flanges with gasketing to protect seams between roof panels Sealer strip Raised flanges Sealer strips pull roof flanges together Pitched both way to cabinet sides for rain water runoff 1 ½ roof overhang for rainwater flowing from unit top will not drip onto the door tops. Roof overhang

6. RT Roof Mounted Air Handlers Weatherproof Cabinet Construction Cabinet made of galvanized steel and powder coated to provide excellent weatherability and corrosion resistance passing 1000 hrs salt spray test Cabinet made to remain water tight construction Weather hood with moisture eliminator for outside air intakes Double access door frames with gasket design with heavy duty latches to form the seal Outer Door Frame with gasket Inner Door Frame

6. RT Roof Mounted Air Handlers 6. RT Roof Mounted Air Handlers Internal built-in pipe chase and piping vestibule for routing of coil piping inside the cabinet

6. RT Roof Mounted Air Handlers Unit Base Rail Factory designed unit base rail permits adaptation to roof curb site installation by others Typical Roof Curb (by others)

7. Selection Program Electronic Catalog (SPEC 7) For the ease of various unit sections and equipments selection, computer selection software is available for prompt and accurate equipment sizing.

7. Selection Program Electronic Catalog (SPEC 7) Sample Print-Out

8. Air Handlers for Special Applications ENERGY RECOVERY UNIT : Heatwheel Application AHU with built-in Heat Recovery Wheel to accomplish precool of fresh air to reduce cooling capacity EXHAUST AIR RETURN AIR FRESH AIR SUPPLY AIR

STACKED CONFIGURATION

Plate heat exchanger

8. Air Handlers for Special Applications ENERGY RECOVERY UNIT : Heatpipe Application AHU with built-in Heatpipe to accomplish reheat while also reducing cooling capacity (precool) WARM & HUMID PRE- COOLED OVER COOLED DRY & COMFORTABLE

8. Air Handlers for Special Applications UNIT WITH PLENUM FAN Space limitations Need for discharge flexibility Duct configurations might change in the future

8. Air Handlers for Special Applications All stainless steel casing unit

8. Air Handlers for Special Applications Unit with VFD application. Unit with UV light application. Return fan, economiser, etc. Switch Board with starter, disconnect switch, etc.

Thank you Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT)