MODEL BV NOZZLE VENTURI NOZZLE SYSYTEM Specification Sheets ALL STAINLESS STEEL COMPRESSED AIR NOZZLE HUMIDIFIERS With ON/OFF or Proportional Controls VENTURI ACTION DESIGN ELIMINATES WATER DROPS IN-SPACE APPLICATIONS INCLUDE: Factories Warehouses Greenhouses Food Storage Hunidity Source, LLC
FogSystem Nozzle Atomizer In-Space Applications The Fog System of humidification uses low maintenance, self cleaning stainless steel nozzles to dispense a very fine mist produced by a combination of compressed air and water. The Venturi Nozzle Venturi Nozzle Model BV The Venturi Nozzle uses com-pressed air to atomize water into a fine stream of particles which are quickly absorbed by the air. As the compressed air is ejected through the nozzle venturi, a vacuum is created which con-stantly draws water up from a reservoir located below the nozzle level. This design offers the added security in that if the compressed air fails water can-not be drawn from the reservoir making the nozzle truly drip less. Each nozzle will produce up to 20pounds of water mist per hour and can be installed in multiples for high humidity demand situations Quick Pack System Pre-assembled for quick installation, the Quick Pack consists of up to 25 Venturi Nozzles, air and water valves and a constant level water reservoir all pre-mounted on a single bar. The bar is designed to be suspended from a ceiling and needs only to be connected with plastic air and water lines from the control cabinet to be operational. Quick Pack System Control Cabinet The Fog System control cabinet regulates air and water pressure to the nozzles, turns the nozzles on or off in response to the humidistat and actuates the adjustable automatic cleaning cycle. Since nozzle water flow is regulated through air actuated valves, no water is present in the cabinet for electrical safety. Proportional control is also available. Control Cabinet
Humidity Source FogSystem Humidifiers Venturi Nozzles (BV) Quick Pack Connection Diagram Nozzles Pre-Mounted On Nozzle Bar Constant Level Water Tank Water In 1/2 Air In 1/2 Air & Water Manifold Humidistat Control Cabinet Power Humidity source, LLC
Humidity source FogSystem Humidifiers Venturi Nozzle System Diagram Model BV Venturi Nozzle Cleaning Air Air Water Constant Level Water Supply Reservoir Water In ½ Overflow Water out 3/8 Air In ½ Air to Nozzle 3/8 Air to Control Cabinet Humidistat Control Cabinet Power To Main Air Valve ¼ Cleaning Air
VENTURI NOZZLES - MODEL BV 1 3 2 4 1. MAIN AIR INLET. Main atomizing air supply to nozzle. 2. CLEANING AIR. Air connection to power cleaning needle. 3. MAIN WATER INLET. Main water supply for atomizing. 4. CLEANING NEEDLE. Cleans the nozzle atomizing orifice. OPERATION The model BV nozzle draws water by venturi action from the constant level water reservoir. This nozzle is also equipped with an automatic nozzle orifice cleaning needle, which is controlled by a timer in the control cabinet. During the cleaning cycle a piston is advanced and retracted positively by air pressure. This is unique in that there are no springs, which can weaken over time, to operate the cleaning mechanism. Piston driven air pressure powers the cleaning needle in both directions. Because of the venture action, with no water pressure applied to the nozzle, the BV is essentially drip less. This feature makes it ideal for use in printing plants, photo processing, electronics fabrication, and many other applications where water drops are not tolerable. The BV nozzles are available with wall mounting brackets as shown, or pre-mounted nozzle bars with all air and water tubing lines in place for easy installation.
BV NOZZLE QUICK PACK Pre-Assembled Venturi Type Nozzle Installation 1 4 Air & Water Lines 3 2 Nozzle Bars Can Be Suspended From Ceiling or Wall Mounted 1. Quick Pack Pre-mounted Bar 3. Humidistat 2. Control Cabinet 4. Constant Level Water Tank INSTALLATION 1. Place system components in their approximate positions. 2. Install nozzles bars as high as possible by suspending from ceiling or wall mounting. Position so mist cannot strike beams, pipes, light fixtures, conduits, etc. 3. Install constant level water tank high on wall eight to sixteen inches below the nozzle bar. See capacity chart for placement details. 4. Install air and water filters and connect compressed air and water service. 5. Install nozzle air and water manifold and connect to filters. 6. Mount control cabinet on wall and connect 230 volt, 100VA electrical power. 7. Run two 1/4" plastic tubes from control cabinet to manifold (air in & air out). 8. Run one 1/4" plastic tube from control cabinet to nozzle bar (cleaning cycle air). 9. Run one 3/8 plastic tube from manifold to nozzle bar air fitting (main air). 10. Run one 3/8 plastic tube from manifold to constant level water tank inlet fitting ( main water). 11. Connect constant water tank outlet to water fitting on nozzle bar. 12. Mount humidistat & connect to control cabinet.
The Venturi FogSystem Control Cabinets CONTROL CABINET TYPES: Proportional ON/OFF - One Zone ON/OFF Two Zone ON/OFF Three Zone Typical Connections 6 1. Power 2. Humidistat 7 2 1 3. Air In 4. Cleaning Air Out 5. Air to Main Air Valve 8 4 5 6. ON/OFF Switch 9 3 7. Green Light ON when humidifying 8. Pressure Gauge 9. Adjustment Valve Air & Water Manifold Water To Constant Level Water Tank Main Air Control From Cabinet Air Air To Nozzles
VENTURI NOZZLE CONSTANT LEVEL WATER RESERVOIR 11 13/16 13 7/16 5 1 4 Filled Weight 55 lbs. 2 26 3 6 WATER AIR 8 7 Air Regulator control 8 11/16 1 9/16 1. Over Flow 2. Water Outlet (male 3/8 ) 3. Main Water Supply (male 3/8 ) 4. Constant Level Water Tank 5. Stainless Steel Mounting Bracket 6. Main Air Supply 7. Water Regulator & Gauge 8. Air Regulator & Gauge
Nozzle Level H Water Tank Output Level 25 20 15 10 5 0 VENTURI NOZZLE (BV) CAPACITY CHART BV NOZZLE OUTPUT VS. AIR PRESSURE AND HEIGHT ABOVE CONSTANT LEVEL WATER TANK Air Pressure 90 PSI 75 PSI 60 PSI 45 PSI 90 PSI 75 PSI 60 PSI 45 PSI 1 2 4 8 12 16 20 24 28 32 Height H Inches Output lbs./hr. Water Vapor
W351A Modular Electronic On/Off Humidity Sensor/Controller With Optional Digital Display Maximum Flexibility Modular Construction On/Off, Step, or Proportional Remote Sensor Remote Display Remote Set Point The W351A Electronic Controller and Humidity Sensor is designed to be used where electronic sensitivity is desired, for close tolerance humidity control, or for installations where the display or set point adjustment must be remotely located. Sensor Controller & Power Module Digital Display (Optional) W351 Series Electronic Controllers Applications computer rooms clean rooms pharmaceutical manufacturing staged cooling & humidification schools hospitals laboratories office buildings photo processing paper storage food storage printing plants bakeries humidors W351A Electronic Humidity Control On/Off The W351A Electronic Control is an electronic on/off humidity control. The control output is a Single-Pole, Double-Throw (SPDT) relay with LED indication. It features humidification and dehumidification modes of operation and an adjustable differential. Set Point Range Differential 10 to 90% RH 2 to 10% RH Features: humidification and/or dehumidification adjustable differential and set point surface or DIN rail mounting no wiring between modules
FogSystem Humidifiers W351A Humidity Control System Wiring Diagram ON/OFF Control 24V Controller W351A Power Module Y350R Digital Display D351 COM PWR OUT Sensor COM VDC SEN Differential Potentiometer Set on 4% RH Display Window Set Point Button NC COM NO 120/240 VAC Set Point Dial Relay Modular Connector Operation Mode Jumper Positions Dehumidification Humidification Adjustments W351A 1. Remove the W351 cover by loosening the four captive cover screws. 2. Set the operation mode jumpers to the desired mode of operation (vertically for humidification). 3. Adjust the differential potentiometer to the desired setting. Clockwise increases differential. 4. Replace the cover and adjust the set point dial to the desired level. 5. If using the D351 display, press and hold the set point button while rotating the set point dial for most accurate settings. Sequence of Operation Cover Screws (Qty 4) Humidity controller (W351A) powered by transformer (Y350) senses space humidity via room the sensor. (Set point of 45% RH and differential at 4%RH) On drop in humidity to 41% RH W351A closes the contact between COM & NO to start the humidifier. As the humidity increases to 45% W351 opens the circuit and stops the humidifier. The digital display module (D351) shows continuous readout of space humidity. Cabinet Terminal Block 9 8 7 6 5 4 3 2 1 GROUND 208-240 VAC
FogSystem Humidifiers W351A Humidity Control System Wiring Diagram ON/OFF Control 24V Controller W351A Power Module Y350R Digital Display D351 COM PWR OUT Sensor COM VDC SEN Differential Potentiometer Set on 4% RH Display Window Set Point Button NC COM NO 120/240 VAC Set Point Dial Relay Modular Connector Operation Mode Jumper Positions Dehumidification Humidification Adjustments W351A 1. Remove the W351 cover by loosening the four captive cover screws. 2. Set the operation mode jumpers to the desired mode of operation (vertically for humidification). 3. Adjust the differential potentiometer to the desired setting. Clockwise increases differential. 4. Replace the cover and adjust the set point dial to the desired level. 5. If using the D351 display, press and hold the set point button while rotating the set point dial for most accurate settings. Sequence of Operation Cover Screws (Qty 4) Humidity controller (W351A) powered by transformer (Y350) senses space humidity via room the sensor. (Set point of 45% RH and differential at 4%RH) On drop in humidity to 41% RH W351A closes the contact between COM & NO to start the humidifier. As the humidity increases to 45% W351 opens the circuit and stops the humidifier. The digital display module (D351) shows continuous readout of space humidity. Cabinet Terminal Block 9 8 7 6 5 4 3 2 1 GROUND 208-240 VAC