Operation of electrical installations -- Part 1: General requirements

Similar documents
Founding - Magnetic particle testing

High-voltage switchgear and controlgear -- Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kv (IEC :2011 (EQV))

Paper and board - Determination of grammage (ISO 536:2012)

Office furniture - Office work chair - Part 2: Safety requirements

Hexagon regular nuts (style 1) - Product grades A and B (ISO 4032:2012)

Cylindrical helical springs made from round wire and bar - Calculation and design - Part 1 : Compression springs

Medical gloves for single use - Part 2: Requirements and testing for physical properties

Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO :2011)

Furniture - Children's cots and folding cots for domestic use - Part 2: Test methods

Bitumen and bituminous binders - Determination of the paraffin wax content - Part 1: Method by distillation

Quality Management Systems - Audit Requirements for Aviation, Space, and Defence Organizations

Gas meters - Additional functionalities

Railway applications - Communication, signalling and processing systems - Safety-related communication in transmission systems

Resilient, textile and laminate floor coverings - Classification (ISO 10874:2009)

Aerospace series - Quality systems - First article inspection requirements

Water-tube boilers and auxiliary installations - Part 3: Design and calculation for pressure parts of the boiler

Camping tents (ISO 5912:2011)

Irish Standard Recommendation S.R. CEN/TS 115-4:2015

OVERHEAD ELECTRICAL LINES EXCEEDING

Radiological protection - Sealed radioactive sources - General requirements and classification (ISO 2919:2012)

Metallic materials - Calibration of forceproving instruments used for the verification of uniaxial testing machines (ISO 376:2011)

Irish Standard I.S. EN :2009

Paints and varnishes - Corrosion protection by protective paint systems - Assessment of porosity in a dry film (ISO 29601:2011)

Foodstuffs - Determination of vitamin C by HPLC

Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kv - Part 1: General requirements

Bitumen and bituminous binders - Specifications for paving grade bitumens

Earthing of power installations exceeding 1 kv a.c.

ELECTRICAL AND INSTRUMENTATION LOOP CHECK (IEC 62382:2006 (EQV)) IRISH STANDARD I.S. EN 62382:2007. Price Code

Plastic containers for intravenous injections (ISO 15747:2010)

Irish Standard I.S. EN :2011

General requirements for establishing anthropometric databases (ISO 15535:2012)

Permanently installed outdoor fitness equipment - Safety requirements and test methods

Temporary structure - Tents - Safety

Stationary training equipment - Part 1: General safety requirements and test methods (ISO :2013)

PHOTOVOLTAIC DEVICES -- PART 2:

Plastics piping systems for renovation of underground water supply networks - Part 3: Lining with close-fit pipes (ISO :2010)

Petroleum, petrochemical and natural gas industries - Hairpin-type heat exchangers (ISO 12212:2012)

Quality management systems - Fundamentals and vocabulary (ISO 9000:2015)

HEXALOBULAR INTERNAL DRIVING FEATURE FOR BOLTS AND SCREWS (ISO 10664:2005) IRISH STANDARD I.S. EN ISO 10664:2005. Price Code

Sterilization of health care products - Moist heat - Part 2: Guidance on the application of ISO (ISO :2009)

Irish Standard I.S. EN ISO :2013

CONVENTIONS CONCERNING ELECTRIC AND MAGNETIC CIRCUITS (IEC 60375:2003) IRISH STANDARD I.S. EN 60375:2003. Price Code

ALARM SYSTEMS - INTRUSION AND

Personal protective equipment - Safety footwear (ISO 20345:2011)

Energy management systems - Requirements with guidance for use (ISO 50001:2011)

Needle-based injection systems for medical use - Requirements and test methods - Part 2: Needles (ISO :2012)

REFRIGERATING SYSTEMS AND HEAT

BIOLOGICAL EVALUATION OF MEDICAL

ILNAS-EN ISO 23640:2015

CONFORMITY ASSESSMENT - SUPPLIER'S

Fasteners - Hexagon head screws - Product

Irish Standard I.S. EN 378-1:2008+A2:2012

SECONDARY CELLS AND BATTERIES

Irish Standard I.S. EN :2011&A1:2014

Sýnishorn Maintenance - Qualification of maintenance personnel

LABORATORY GLASSWARE - GRADUATED MEASURING CYLINDERS (ISO 4788:2005) IRISH STANDARD I.S. EN ISO 4788:2005. Price Code

Safety of toys - Part 2: Flammability

CLEAR LIQUIDS - ESTIMATION OF COLOUR BY THE GARDNER COLOUR SCALE - PART 1: VISUAL METHOD (ISO :2004) IRISH STANDARD I.S. EN ISO :2005

COMMUNICATION SYSTEMS FOR AND REMOTE READING OF METERS - PART 2: PHYSICAL AND LINK LAYER IRISH STANDARD I.S. EN :

Personal protective equipment - Test methods for footwear (ISO 20344:2011)

Safety of woodworking machines - Circular sawing machines - Part 12: Pendulum cross-cut sawing machines

PAPER - DETERMINATION OF BURSTING STRENGTH (ISO 2758:2001) IRISH STANDARD I.S. EN ISO 2758:2003. Price Code

Eurocode 2 - Design of concrete structures - Part 3: Liquid retaining and containment structures

STEEL TUBES AND FITTINGS FOR ON SHORE AND OFFSHORE PIPELINES - INTERNAL LINING WITH CEMENT MORTAR IRISH STANDARD I.S. EN 10298:2005.

PACKAGING - REQUIREMENTS FOR PACKAGING RECOVERABLE BY MATERIAL RECYCLING STANDARD I.S. EN 13430:2004. Price Code

DECORATIVE WALLCOVERINGS - ROLL AND PANEL FORM PRODUCTS IRISH STANDARD I.S. EN 15102:2007. Price Code. Údarás um Chaighdeáin Náisiúnta na héireann

Irish Standard I.S. EN :2011+A1:2014

Sýnishorn Power installations exceeding 1 kv a.c. - Part 1: Common rules

Water meters for cold potable water and hot water - Part 4: Non-metrological :2014)

Road lighting - Part 2: Performance requirements

Dentistry - Powered scaler (ISO 18397:2016)

ÍST EN :2013. Gildistaka ICS: 75.2

RAILWAY APPLICATIONS - ELECTROTECHNICAL EQUIPMENT FOR ROLLING STOCK PART 5: ELECTROTECHNICAL COMPONENTS RULES FOR HV FUSES (IEC :2003)

SOUTH AFRICAN NATIONAL STANDARD

Health Informatics - Harmonized data types for information interchange (ISO 21090:2011)

Dentistry - Powered polymerization activators (ISO 10650:2015)

Framework for a specification on the avoidance of a damaging Alkali-Silica Reaction (ASR) in concrete

Solar energy - Solar thermal collectors - Test methods (ISO 9806:2013)

REFRIGERATING SYSTEMS AND HEAT

Packaging - Distribution packaging - Graphical symbols for handling and storage of packages (ISO 780:2015)

Desktop and notebook computers - Measurement of energy consumption (IEC 62623:2012 (EQV))

Environmental management systems - Requirements with guidance for use (ISO 14001:2015)

Water quality - Determination of ph (ISO 10523:2008)

ILNAS-EN 62560:2012/A1:2015

ILNAS-EN 61882:2016. Hazard and operability studies (HAZOP studies) - Application guide

Quality management systems - Requirements (ISO 9001:2015)

EXECUTION OF SPECIAL GEOTECHNICAL WORKS - MICROPILES IRISH STANDARD I.S. EN 14199:2005. Price Code. Údarás um Chaighdeáin Náisiúnta na héireann 93.

HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY PART 2-13: PARTICULAR REQUIREMENTS FOR DEEP FAT FRYERS, FRYING PANS AND SIMILAR

SOUTH AFRICAN NATIONAL STANDARD

Application of equipotential bonding and earthing in buildings with information technology equipment

Irish Standard I.S. EN :2016

Environmental management systems - General guidelines on principles, systems and support techniques (ISO 14004:2004)

NATURAL GAS - CALCULATION OF

Irish Standard I.S. EN ISO :2009&A1:2014. CEN 2014 No copying without NSAI permission except as permitted by copyright law.

Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989 (EQV))

NATURAL STONE PRODUCTS - MODULAR TILES - REQUIREMENTS IRISH STANDARD I.S. EN 12057:2004. Price Code. Údarás um Chaighdeáin Náisiúnta na héireann

Automatic test systems for battery powered emergency escape lighting (IEC 62034:2012 (EQV))

Medical devices - Application of risk management to medical devices (ISO 14971:2007, Corrected version )

Irish Standard I.S. EN ISO 13791:2012

Cosmetics - Good Manufacturing Practices (GMP) - Guidelines on Good Manufacturing Practices (ISO 22716:2007, Corrected version )

Transcription:

Irish Standard I.S. EN 50110-1:2013 Operation of electrical installations -- Part 1: General requirements CENELEC 2013 No copying without NSAI permission except as permitted by copyright law.

I.S. xxx: Irish Standard national specification based on the consensus of an expert panel and subject to public consultation. S.R. xxx: Standard Recommendation - recommendation based on the consensus of an expert panel and subject to public consultation. SWiFT xxx: A rapidly developed recommendatory document based on the consensus of the participants of an NSAI workshop. 25 March, 2013 EN 50110-1:2004 19 January, 2005 25 March, 2013 EN 50110-1:2013 EN 50110-1:2004 This document was published under the authority of the NSAI and comes into effect on: 15 March, 2013 30 November, 2004 ICS number: 29.240.01 1 Swift Square, Northwood, Santry Dublin 9 T +353 1 807 3800 F +353 1 807 3838 E standards@nsai.ie W T +353 1 857 6730 F +353 1 857 6729 W standards.ie Údarás um Chaighdeáin Náisiúnta na héireann

EUROPEAN STANDARD EN 50110-1 NORME EUROPÉENNE EUROPÄISCHE NORM March 2013 ICS 29.240.01 Supersedes EN 50110-1:2004 English version Operation of electrical installations - Part 1: General requirements Exploitation des installations électriques - Partie 1: Exigences générales Betrieb von elektrischen Anlagen - Teil 1: Allgemeine Anforderungen This European Standard was approved by CENELEC on 2013-02-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50110-1:2013 E

EN 50110-1:2013 2 Contents Page Foreword... 4 Introduction... 5 1 Scope... 6 2 Normative references... 6 3 Terms and definitions... 7 3.1 General... 7 3.2 Personnel, organisation and communication... 8 3.3 Working zone... 9 3.4 Working... 9 3.5 Protective devices... 10 3.6 Nominal voltages... 11 4 Basic principles... 11 4.1 Safe operation... 11 4.2 Personnel... 12 4.3 Organisation... 12 4.4 Communication (transmission of information)... 13 4.5 Work location... 14 4.6 Tools, equipment and devices... 14 4.7 Drawings and records... 15 4.8 Signs... 15 4.9 Emergency arrangements... 15 5 Operational procedures... 15 5.1 General... 15 5.2 Operating activities... 15 5.3 Functional checks... 16 6 Working procedures... 18 6.1 General... 18 6.2 Dead working... 19 6.3 Live working... 22 6.4 Working in the vicinity of live parts... 26 7 Maintenance procedures... 28 7.1 General... 28 7.2 Personnel... 28 7.3 Repair work... 29 7.4 Replacement work... 29 7.5 Temporary interruption... 30 7.6 End of maintenance work... 30 Annex A (informative) Guidance for distances in air for working procedures... 32 A.1 General... 32 A.2 Live working... 32 A.3 Work in the vicinity... 32 Annex B (informative) Additional information for safe working... 34 B.1 Example for responsibility levels... 34 B.2 Example of application of live working... 35 B.3 Atmospheric conditions that are part of environmental conditions to be assessed... 36 B.4 Fire protection Fire fighting... 36 B.5 Work location presenting explosion risks... 37

3 EN 50110-1:2013 B.6 Arc hazard... 37 B.7 Emergency arrangements... 38 Bibliography... 40 Figure 1 Distances in air and zones for working procedures... 31 Figure 2 Limitation of the live working zone by the use of an insulating protective device... 31 Figure B.1 Responsibility levels... 34 Table A.1 Guidance for distances D L and D V... 33

EN 50110-1:2013 4 Foreword This document (EN 50110-1:2013) has been prepared by CLC/BTTF 62-3 "Operation of electrical installations". The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-02-11 latest date by which the national standards conflicting with this document have to be withdrawn This document supersedes EN 50110-1:2004. (dow) 2016-02-11 EN 50110-1:2013 includes the following significant technical changes with respect to EN 50110-1:2004: improvement of the definitions of persons responsible and level of responsibility; addition of a clause on emergency arrangements; addition of example of level of responsibility in Annex B; addition of a clause on arc hazard in Annex B; addition of a clause on emergency arrangements in Annex B; update of the normative references and of the Bibliography. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights.

5 EN 50110-1:2013 Introduction There are many national laws, standards and internal rules dealing with the matters coming within the scope of EN 50110 and these practices have been taken as a basis for this work. EN 50110 consists of two parts: Part 1 of EN 50110 contains minimum requirements valid for all CENELEC countries and some additional informative annexes dealing with safe working on, with, or near electrical installations; Part 2 of EN 50110 consists of a set of normative annexes (one per country) which either specify the present safety requirements or give the national supplements to these minimum requirements. This concept is still believed to be a decisive step to the gradual alignment in Europe of the safety levels associated with the operation of, work activity on, with, or near electrical installations. This document acknowledges the present different national requirements for safety. The intention is, over the course of time, to create a common level of safety. Even the best rules and procedures are of no value unless all persons working on, with, or near electrical installations are thoroughly conversant with them and with all legal requirements and comply strictly with them.

EN 50110-1:2013 6 1 Scope This European Standard is applicable to all operation of and work activity on, with, or near electrical installations. These are electrical installations operating at voltage levels from and including extra-low voltage up to and including high voltage. This latter term includes those levels referred to as medium and extra-high voltage. These electrical installations are designed for the generation, transmission, conversion, distribution and use of electrical power. Some of these electrical installations are permanent and fixed, such as a distribution installation in a factory or office complex, others are temporary, such as on construction sites and others are mobile or capable of being moved either whilst energised or whilst not energised nor charged. Examples are electrically driven excavating machines in quarries or open-cast coal sites. This European Standard sets out the requirements for the safe operation of and work activity on, with, or near these electrical installations. The requirements apply to all operational, working and maintenance procedures. They apply to all non-electrical work activities such as building work near to overhead lines or underground cables as well as electrical work activities, when there is a risk of electrical danger. This European Standard does not apply to ordinary persons when using installations and equipment, provided that the installations and equipment comply with relevant standards and are designed and installed for use by ordinary persons. This European Standard has not been developed specifically to apply to the electrical installations listed below. However, if there are no other rules or procedures, the principles of this European Standard could be applied to them on any aircraft and hovercraft moving under its own power, (these are subject to International Aviation laws which take precedence over national laws in these situations); on any sea going ship moving under its own power, or under the direction of the master, (these are subject to International Marine laws which take precedence over national laws in these situations); electronic telecommunications and information systems; electronic instrumentation, control and automation systems; at coal or other mines; on off-shore installations subject to International Marine laws; on vehicles; on electric traction systems; on experimental electrical research work. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50191, Erection and operation of electrical test equipment EN 61219, Live working Earthing or earthing and short-circuiting equipment using lances as shortcircuiting device Lance earthing (IEC 61219) EN 61230, Live working Portable equipment for earthing or earthing and short-circuiting (IEC 61230) EN 61243 (all parts), Live working Voltage detectors (IEC 61243, all parts) EN 61472, Live working - Minimum approach distances for a.c. systems in the voltage range 72,5 kv to 800 kv A method of calculation (IEC 61472)

This is a free preview. Purchase the entire publication at the link below: I.S. EN 50110-1:2013 - PDF his is a free 8 page sample. Access the full version online. Looking for additional Standards? Visit SAI Global Infostore Learn about LexConnect, All Jurisdictions, Standards referenced in Australian legislation Need to speak with a Customer Service Representative - Contact Us