Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Similar documents
Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48PGD/E/F/L/M/N PG20-28

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

62DA,DB,DC,DD,DE,DF07-38

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Product Data RELIABILITY FEATURES

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

50TC Single Package Rooftop Cooling Only Vertical Air Flow Unit with Puron

50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29)

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

RGE 13 A T - 1 A

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons. (Unit shown with economizer and power exhaust.

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

DCG Commercial. Submittal Data Form

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Advanced Product Data

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Input Cap. (Btuh) Stage 2

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Product Data 50TC. Cooling Only/Electric Heat Packaged Rooftop Vertical Models Nominal Tons 15, 17.5, 20, 25, 27.5 Model Sizes 17, 20, 24, 28, 30

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Ruud Commercial Achiever Series Package Gas Electric Unit

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Submittal Data Performance Data Electrical Data

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop Vertical Models Nominal Tons 15, 17.5, 20, 25, 27.5 Model Sizes 17, 20, 24, 28, 30

GUIDE SPECIFICATIONS 48LC**14-26

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

RHEEM PACKAGE GAS/ELECTRIC

Product Data. Fig. 1 - Unit 50VR -A

13 GEP A L P - 1 A

Input Cap. (Btuh) Stage 2

Advanced Product Data

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

GUIDE SPECIFICATIONS - 48LC*004-06

PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE

PAR5. Product Specifications

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

Product Data. 48LC Ultra High Efficiency Gas Heat/Electric Cooling Packaged Rooftop 3to5NominalTons. Carrier s Most Efficient Commercial Rooftop Ever!

50KCQ Packaged Heat Pump 14 SEER 3to5NominalTons. Product Data C08613

48KC Gas Heat/Electric Cooling Single Packaged Rooftop 14 SEER 3to5NominalTons. Product Data C08613

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

PERFORMANCE, INNOVATION, RELIABILITY

GUIDE SPECIFICATIONS - 48TC**04-14

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Product Data. Fig. 1 - Unit 50VG -A

THE RIGHT SPEC. RIGHT NOW.

Product Data. Features/Benefits

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Product Data. Fig. 1 - Unit 50EZ -A

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

RHX. Product Specifications

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

Submittal Summary Page

Product Data KUWAIT SERIES

Product Data WeatherMaker Single Package Rooftop Heat Pump Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

GUIDE SPECIFICATIONS - 48HC*D17-28

PAJ3. Product Specifications

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

GUIDE SPECIFICATIONS - 50TC**18-29

4YCC3048A3096A /3/ /

Roof Top Packaged Unit (RTU-1) Specification

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

50TJM 60Hz Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

PERFORMANCE, INNOVATION, RELIABILITY

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Transcription:

Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Copyright 2012 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 02/12 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: ---16SB Replaces: ---12SB

Job Data: Location: Buyer: Buyer P.O.#: Carrier: Unit Number: Model Number: Unit Designation: Performance Data Certified By: Certified to ISO 9001 Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. DESCRIPTION units are single -packaged electric cooling, gas heating units that are pre-wired and pre-charged with PuronR (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. STANDARD FEATURES Base Unit S Puron (R-410A) HFC refrigerant S Two-stage cooling capacity control on all models S EER s up to 10.8 S IEER s: up to 12.0 with standard motor up to 12.7 with 2 speed/vfd indoor fan motor S Designed in accordance with Underwriters Laboratories Standard 1995 S Listed by ETL S ASHRAE 90.1 energy compliant S Rated in accordance with AHRI Standard 340/360 S Non-corrosive composite sloping design; side or center drain condensate pan. Meets ASHRAE Standard 62 S Standard cooling operating range from 30_F upto 115_F (-1_C upto46_c) S Dedicated vertical and horizontal airflow models available as factory option. No special field kits required. S Two-inch disposable return air filters on slide out track S Provisions for thru-the-bottom power entry capability as standard in an environmentally protected area S Single point gas and electric connections S 24-volt control circuit protected with resettable circuit breaker and 75-VA transformer S Permanently lubricated evaporator-fan motor S Blower bearing extend lubrication line on all sizes S Totally enclosed condenser motors with permanently lubricated bearings S Low-pressure and high-pressure switch protection S Full perimeter base rail with built-in rigging adapters and fork truck slots S New central terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement S High performance belt drive motor with variable pitch pulleys, quick adjust belt system and fan belt protection Cabinet S Access panels with easy grip handles S Innovative, easy starting, no-strip screw feature on unit access panels S Pre -painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection S Fully insulated cabinet Refrigerant System S Acutrolt refrigerant metering system S Liquid line filter drier on each circuit S Scroll compressors with internal line-break overload protection S Copper tube, aluminum fin evaporator coil S Round Tube/Plate Fin (RTPF) condenser coils on all model sizes or NOVATIONt all aluminum condenser coils available on 17-28 sizes. Gas Heat S Gas efficiencies up to 81% S Induced draft combustion design S Redundant gas valve, with up to 2 stages of heating S Solid-state electronic direct spark ignition system S Exclusive IGC anti-cycle protection for gas heat operation S Flame roll-out safety protector 2

STANDARD FEATURES (cont.) Standard Warranty S 10-year gas heat exchanger parts - Aluminized S 15-year gas heat exchanger parts - Stainless Steel S 5-year compressor parts S 3-year Novation condenser coil parts S 1-year parts PERFORMANCE DATA Unit Operating Weight lb Cooling Gross Total Capacity: Btuh at Condenser Air Temperature _F Gross Sensible Capacity: Btuh Compressor Power Input: kw Indoor Entering db _F wb _F Airflow CFM External Static Pressure in.wg Indoor Fan Motor Size Hp Exhaust Fan Motor Size Hp Curb Weight Heating Heating Capacity: Stage 1 Stage 2 Heating Capacity Total Stage 1 Stage 2 Heating Capacity Total lb Btuh Btuh Btuh kw kw kw ELECTRICAL DATA Power Supply to Unit Volts Phase Hz Minimum Circuit Amps Maximum Overcurrent Protection Job Name Architect Engineer Contractor Unit Designation SUBMITTAL DATA 3

OPTIONS AND ACCESSORIES FACTORY -INSTALLED OPTIONS (FIOPs) j Staged Air Volume (SAV) system utilizes a Variable Frequency Drive (VFD) to automatically adjust the indoor fan motor for 2 speed indoor fan motor control. Conforms to ASHRAE 90.1 2010 Standard section 6.4.3.10.b. Not available with Humidi-MiZer R option. j Vertical air flow duct configuration models j Horizontal air flow duct configuration models j RTU Open protocol controller communicates to. LON, MODBUS, BACNET and Johnson N2 protocols. j CCN Direct Digital Control (DDC) - PremierLink j Through the base connectors for gas and electric conduit/piping j Stainless steel gas heat exchanger (includes tubes, vestibule plate and collector box) j Standard Economizer with dry bulb sensing and barometric relief j Standard Economizer with enthalpy sensing and barometric relief j Ultra Low Leak economizer with maximum leakage rate equal or less than 4.0 cfm/sq. ft. at 1.0 in. w.g. Available on models with Staged Air Volume (SAV) 2 speed indoor fan motor only. j 2 position motorized outdoor air damper j 25% Manual outdoor air damper j Humidi-MiZer adaptive dehumidification system available for sizes 17-28. Unit must be equipped with RTPF condenser coils. j Non-fused disconnect j Powered 115-volt convenience outlet j Non-powered 115-volt convenience outlet j Medium and High static motor options j Return Air smoke detector j Supply Air smoke detector j CO 2 sensor j Condenser hail guard - louvered style j Special coating protection for evaporator and condenser coils OPTIONAL WARRANTIES j Complete Unit Parts only up to 5 years j Complete Unit Parts and Labor up to 5 years Many other optional warranties are available. See the Commercial Start -Up and Optional Extended Warranty Price price pages for further information. FIELD INSTALLED ACCESSORIES j EconoMi$ertX Ultra Low Leak electromechanical, gear driven with Honeywell W7220 digital controller. Used with 2 speed Staged Air Volume (SAV) systems only. j Display Kit for Variable Frequency Drive (VFD), Staged Air Volume System. Allows additional set up and diagnostics of the unit VFD controller. Can be unit mounted or used with any other VFD model as a reusable device. j EconoMi$ert IV-electromechanical, gear driven with Belimo actuator (2-10v DC signal) and controller j EconoMi$ert2-compatible with DDC controls; gear driven with Belimo actuator (4-20mA) signal and no controller j Power exhaust - centrifugal fan design j Two-position motorized outdoor air damper j 25% Manual outside air damper j Roofcurb - 14 inch (356mm) tall j Roofcurb - 24 inch (610mm) tall j Adapter Curb (for sizes 17-28 only) - Adapts to Carrier DP/DR, TJ, HJ, TM, PG roofcurbs j Condenser hail guard - louvered style j Flue discharge deflector j Liquid propane (LP) conversion kit j High altitude conversion kit j Phase monitor (loss of phase/phase reversal) j Winter start kit, down to 25_F (-4_C) j Low ambient head pressure controller, down to -20_F (-29_C) j Time Guard II compressor anti -cycle protection j Four inch filter tracks j Return Air smoke detector j Supply Air smoke detector j Thermostats and Sensors Economizer Sensors j Single Dry bulb control j Differential Dry bulb control j Single enthalpy control j Differential enthalpy control j CO 2 - wall mounted j CO 2 - duct mounted j CO 2 - unit mounted 4

CERTIFIED DIMENSION **17, 20 C101233 5

CERTIFIED DIMENSION **17, 20 C101234 6

CERTIFIED DIMENSION **24, 28 C101235 7

CERTIFIED DIMENSION **24, 28 C101236 8

CERTIFIED DIMENSION **30 C11236 9

CERTIFIED DIMENSION **30 C11237 10

ROOF CURB DETAILS - 17 & 20 SIZE UNITS C09052 11

ROOF CURB DETAILS - 24 & 28 SIZE UNITS C09100 12

ROOF CURB DETAILS - 30 SIZE UNIT C11224 13

14