INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

Similar documents
HEAT HEAT HEAT COOL COOL

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

7-Day. Digital Thermostat. residential. & 2-cool

Installation Instructions HEAT COOL FAN POWER

5+2 Day. up to HEAT COOL

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03

Installation Instructions

asy Single Day up to 2-heat & 2-cool Stat

Small Digital Thermostat Controller Temperature Control

Installation Instructions

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCNB001 TSTATBBNB001 P Digital Thermostat

HEAT HEAT PUMP TOTALINE. Installation Instructions DIGITAL THERMOSTAT MODEL P FM. I2:00 Mo COOL

OWNER S MANUAL Venstar Inc. 08/07

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00

OWNER S MANUAL Venstar Inc. 08/07

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

HEAT HEAT HEAT COOL COOL

Installation Instructions

P/N TSTAT0713K 1 For All Programmable Temperature & Humidity AUTO 70 COOL. 2 HEAT - 2 COOL Meets Residential California Title 24

OWNER S MANUAL Venstar Inc. 08/07

Owner s Manual. Digital Thermostat

Non-Programmable Digital Thermostat

OWNER'S MANUAL T0140. Contents Page #

HEAT COOL. Meets Commercial California Title 24

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

2 - Wire Programmable Digital Thermostat

Owner s Manual. Digital Thermostat. Non-Programmable

Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand.

Installation Instructions

Programmable 5-2 Day Digital Thermostat

DIGITAL THERMOSTAT Up To 2 Heat & 2 Cool Stages with Humidity Control

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

LOW VOLTAGE CONTROL CIRCUIT WIRING

HEAT COOL HEAT PUMP MULTI-STAGE SINGLEDAYPROGRAMMABLE TSTATCCPB101 TSTATBBPB101 P Digital Thermostat

Note the wire colors and letter designations of the existing thermostat to assist in identifying the correct wiring connections to the TS200.

2 HEAT - 1 COOL Meets Residential California Title 24

INSTALLATION INSTRUCTIONS

Auto-Changeover: Cool Setpoint: Deadband: Differential: Heat Setpoint: Icon: Mode: Non-Programmable Thermostat: Programmable Thermostat:

Installation Instructions

P/N TSTAT0709 DIGITAL THERMOSTAT. Installation Instructions HEAT COOL. Warmer HEAT PUMP. International Comfort Products 2003

Owner s Manual. Premier Series Digital Thermostat. and Installation Instructions. Non-Programmable with Humidity Control COMMERCIAL

TH8320U and TH8321U Touch Screen Programmable Thermostats

7-Day. Digital Thermostat. residential. & 2-cool

XFlat Blade. Installation Instructions DIGITAL THERMOSTAT 53DFS250-SL. CoolingOnly,Heat Cool,and Heat Pump MULTI-STAGE SEVEN DAY PROGRAMMABLE

INSTALLATION INSTRUCTIONS

Wiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel.

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

COMMERCIAL. model SFTHCP742WFC. Premier Series Digital Thermostat. Programmable. Owner s Manual. and Installation Instructions

EWT-955WH. Wireless Type Selection. Installation Manual. Installation Tips. Installation Tips

Product Instructions. Viega Programmable Heat/Cool Thermostat. Technical data

5+2 Day. up to HEAT COOL

CTS Series. Owner s Manual. Full Color Touch Screen Display. and Installation Instructions. High Resolution Digital Thermostat

TP-S-855i MENU AUTO HEAT. Installation Tips. Installation Manual. Installation Tips. Installation Tips. Hardwire - 24 VAC Common Wire

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

CP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables.

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

5+2 DAY INSTALLATION. Digital Thermostat. residential. & 1-cool. up to. 1-heat PROGRAMMABLE HEAT COOL HEAT PUMP THERMOSTAT. Venstar Inc.

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

CAUTION. FCC Compliance Statement

Programmable Thermostat

Operator: Save these instructions for future use!

FAST-STAT Black. Red. Gray. Purple. Orange. Orange. Black. Black. Compressor Stage 1 Heat Control. Transformer Transformer L1 L2

Safety & Installation Instructions

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEU22P7S RESIDENTIAL. Model HVAC SERVICE PARTS

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Safety & Installation Instructions

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

Safety & Installation Instructions

Digital Thermostat. Owner s Manual and Installation Instructions. Optional accessories available, including Wi-Fi

TP-S-855C. Installation Tips. Installation Manual. Installation Tips. Installation Tips

INSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page.

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

INSTALLATION MANUAL. Need Help? This manual covers the following models: T705. Power Type. Thermostat Applications Guide. Page.

T855S 5:23. Installation Manual. Installation Tips. Installation Tips. Installation Tips

Installation, Start-Up, and Operating Instructions

COMMERCIAL MODEL DIGITAL THERMOSTAT Up To 4 Heat & 2 Cool Stages with Humidity Control Perfect for the classroom T4900SCH

INSTALLATION MANUAL. Need Help? This manual covers the following models: T805. Power Type. Thermostat Applications Guide. Page.

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J

CAUTION. FCC Compliance Statement

1 For All Programmable Digital Thermostat

LOW VOLTAGE CONTROL CIRCUIT WIRING

Humidity Module OWNER S MANUAL. Complete Control from

SC Installation, Operation & Application Guide

EL-TSTAT-8820 Safety & Installation Instructions

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Commercial Thermostat Submittal Data

Integration Note OVERVIEW AND SUPPORTED FEATURES. Minimum Core Module Version: g! Document Revision Date: 2/14/2013

Safety & Installation Instructions

NP100 Non-Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

Safety & Installation Instructions

CAUTION. FCC Compliance Statement

Siemens Thermostats. RDY2000BN Thermostat

T8400C Electronic Thermostat

Transcription:

Digital Thermostat residential THEMOSTAT T1 800 7-DAY POAMMABLE up to 3-heat & 2-cool PUMP ontrol up to 3 Heat & 2 ool Stages 3 onfigurable Outputs Adjustable 2nd & 3rd Stage Timers & Deadbands Backlit Display & Button Legends Aux Heat Indicator Outdoor Sensor eady with High/Low eadouts for the Day Accepts Optional Humidity Module: ontrols Humidification and Dehumidification Accepts EZ Programmer Accepts Optional I emote ontrol Accepts omfort all Phone ontrol Accessory Use with most Air onditioning & Heating Systems including: 1 or 2 Stage Electric ooling & 3 Stage as Heating, Heat Pump, Electric or Hydronic Heat. INSTALLATION INSTUTIONS Venstar Inc. 08/07

AUTION Follow the Installation Instructions before proceeding. Set the thermostat mode to OFF prior to changing settings in setup or restoring Factory Defaults. AUTION NEVE PUT MOE THAN ONE JUMPE ON THE SAME MIS JUMPE BLOK! THIS MAY DAMAE YOU THEMOSTAT AND VOID YOU WAANTY. OK NOTE: Due to variations in environmental conditions, it is not always possible to achieve the desired humidification or dehumidification setpoint. This device complies with Part 15 of the F ules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 4Z95 Thermostat Fc T1800 Tested to omply with F Standards FO HOME O OFFIE USE Page i

Table of ontents Preparation emove & eplace the Old Thermostat onfiguring the MIS Outputs Wire onnections Wiring Diagrams Test Operation alibrating the Thermostat Sensors TroubleShooting 1 2 3 4 5 6 7 8 Page iii

SETION 1 Preparation 1 Proper installation of the thermostat will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. Assemble tools Flat Blade Screwdriver Wire cutter & Stripper Make sure your Heater/Air onditioner is working properly before beginning installation of the thermostat. arefully unpack the thermostat. Save the screws, bracket, and instructions. Turn off the power to the Heating/Air onditioning system at the main fuse panel. Most residential systems have a separate breaker for disconnecting power to the furnace. Page 1.1

SETION 2 emove & eplace the Old Thermostat emove the cover of the old thermostat. If it does not come off easily check for screws. 2 Loosen the screws holding the thermostat base or subbase to the wall, and lift away. Disconnect the wires from the old thermostat. Tape the ends of the wires as you disconnect them, and mark them with the letter of the terminal for easy reconnection to the new thermostat. Keep the old thermostat for reference purposes, until your new thermostat is functioning properly. Page 2.1

SETION 3 onfiguring the MIS Outputs 3 Section 3 ontents: onfiguring the Jumpers...3.2 Explanation of Jumper Settings...3.3 Page 3.1

W3 DE ONLY) 2 1 4 3 6 5 8 7 X 1 9 Z Y ELE HP B O onfiguring the Jumpers For additional flexibility, your thermostat has three configurable outputs. These outputs are designed to have different functions depending on how the jumpers are set (below). Each output, labeled,, and may be set for one of the five choices available. In the diagram below, the jumper has been set for * (humidification) operation, the jumper has been set for DE* (dehumidification) operation, and the jumper has been set for W3 (3rd stage of heat) operation. 3 (FAN) W3 W1 Y2 ( NO INSTALL IDITY MODULE WITH SENSIN ELEMENT OUTWAD S2 S+5 s1 SND DE Y2 ( ONLY) *The Humidity Module (sold separately) must be installed to operate a humidification and/or dehumidification system. AUTION NEVE PUT MOE THAN ONE JUMPE ON THE SAME MIS JUMPE BLOK! DOIN SO MAY DAMAE YOU THEMOSTAT AND VOID THE WAANTY. Page 3.2 OK

Explanation of Jumper Settings 3 W3 JUMPE SETTIN If the jumper for,, or is set to W3, the corresponding MIS screw terminal on the backplate will control a third stage of heat. W3 MULTI-STAE OPEATION EXPLAINED - SETION 13 of the Owner s Manual The 3rd Stage of Heat is turned on when: (A) The 1st and 2nd stages have been on for the time required (steps #22 And and #23, page 13.6). It is adjustable from 0-60 minutes and the default is two minutes. (B) The temperature from the setpoint is equal to or greater than: the setpoint plus the 1st stage deadband (step #19, 13.5), plus the 2nd stage deadband (step #20, 13.5) plus the 3rd stage deadband (step #21, 13.5). This 3rd stage deadband is adjustable from 0-10 degrees and the default is two degrees. Deadband Heating ooling Deadband Deadband Deadband Deadband db 3 db 2 db 1 db 1 db 2 (adj. 0-10 ) (adj. 0-10 ) (adj. 1-6 ) (adj. 1-6 ) (adj. 0-10 ) 3rd Stage turn on 2nd Stage turn on 1st Stage turn on Heat Setpoint ool Setpoint 1st Stage turn on 2nd Stage turn on DEEASE TEMPEATUE INEASE JUMPE SETTIN If the jumper for,, or is set to, the corresponding MIS screw terminal on the backplate will control a humidification system. IDIFIATION OPEATION - SETION 9 of the Owner s Manual If your HVA unit is equipped with a humidification system and the Humidity Module (sold separately) has been installed, the thermostat will provide power to the,, or terminal of the thermostat when the humidity in the home falls below the humidity setpoint you have chosen. The value for this setpoint ranges from 0% to 60%. If no humidity is desired or if a humidification system has not been installed, set the value to OFF. Page 3.3

Explanation of Jumper Settings (continued) DE JUMPE SETTIN If the jumper for,, or is set to DE, the corresponding MIS screw terminal on the backplate will be connected to the dehumidification terminal of a furnace board. NOTE: Not all furnaces have a dehumidification terminal. DEIDIFIATION OPEATION - SETION 10 of the Owner s Manual If your HVA unit is equipped with a dehumidification system the thermostat will operate in one of two ways. 1) Normally losed (N): The thermostat will de-energize the,, or terminal of the thermostat (this MIS terminal is connected to the DE terminal on your furnace) to allow the fan to run in low speed when the humidity in the home is above the dehumidify setpoint you have chosen and there is a call for 1st stage cooling. 2) Normally Open (NO): The thermostat will energize the,, or terminal of the thermostat (this MIS terminal is connected to the DE terminal on your furnace) to allow the fan to run in low speed when the humidity in the home is above the dehumidify setpoint you have chosen and there is a call for 1st stage cooling. 3 Page 3.4

Explanation of Jumper Settings (continued) 3 Y2 JUMPE SETTIN If the jumper for is set to Y2 the second stage of cooling. Y2 OPEATION - SETION 13 of the Owner s Manual screw terminal on the backplate will control a ontrol up to two ool stages. The 2nd Stage of heat or cool is turned on when: (A) The 1st Stage has been on for the time required (step #22, page 13.6). It is adjustable from 0-60 minutes and the default is two minutes. And (B) The temperature spread from the setpoint is equal to or greater than: the setpoint plus the deadband (step #20, page 13.5), plus the 2nd deadband (step #20, page 13.5). This 2nd deadband is adjustable from 0-10 degrees and the default is two degrees. ooling Deadband Deadband db 1 db 2 (adj. 1-6 ) (adj. 0-10 ) ool Setpoint TEMPEATUE 1st Stage turn on INEASE 2nd Stage turn on Page 3.5

SETION 4 Wire onnections If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below, or the wiring diagrams 4 that follow. Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked or F Fan, Y or ooling W1, W or H Heating W1/O/B h,, M, Vr, A Power O/B ommon ev. Valve W1/O/B* 2nd Stage Heat onfigurable Output #1 onfigurable Output #2 onfigurable Output #3 S+5 emote Sensor +5vdc S1 emote Sensor Signal SND emote Sensor round S2 emote Sensor Signal #2 S+5** S1** SND** S2** * O/B is used if your system is a Heat Pump. ** For instructions on connecting these terminals see page 14.2 of the Owner s Manual. Page 4.1

SETION 5 Sample Wiring Diagrams Section 5 ontents: 5 HVA Equipment Wiring...5.2,, and Wiring...5.6 Page 5.1

W3 DE W1 Y2 ( ONLY) INSTALL IDITY MODULE WITH SENSIN ELEMENT OUTWAD ELE HP B O S2 S+5 S1 SND 6 Wire, 1 Stage ooling, 1 Stage Heat esidential & ommercial 1 Stage ooling, with 1st stage as Heat O ommercial Heat Pump 1 Stage ooling with 2 Stage Heat 5 ELE (FAN) S2 S+5 S1 SND W1/O/B HP B O NO (FAN) 6 onductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac common 24 vac return fan relay compressor relay 1st stage heat circuit 2nd stage heat circuit W1 Page 5.2

W3 DE W1 Y2 ( ONLY) INSTALL IDITY MODULE WITH SENSIN ELEMENT OUTWAD ELE HP B O S2 S+5 S1 SND 6 Wire, 1 Stage ooling, 1 Stage Heat esidential & ommercial 1 Stage ooling, with 1st stage Electric Heat 5 ELE (FAN) S2 S+5 S1 SND W1/O/B HP B O NO (FAN) 6 onductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac common 24 vac return fan relay compressor relay 1st stage heat circuit 2nd stage heat circuit W1 Page 5.3

W3 DE W1 Y2 ( ONLY) INSTALL IDITY MODULE WITH SENSIN ELEMENT OUTWAD ELE HP B O S2 S+5 S1 SND 6 Wire, 1 Stage ooling, 2 Stage Heat esidential Heat Pump with O eversing Valve 1 Stage ooling, with 2 stage Heat 5 ELE (FAN) S2 S+5 S1 SND W1/O/B HP B O NO (FAN) 6 onductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac common 24 vac return Fan elay ompressor elay eversing Valve 2nd stage heat circuit O Page 5.4

W3 DE W1 Y2 ( ONLY) INSTALL IDITY MODULE WITH SENSIN ELEMENT OUTWAD ELE HP B O S2 S+5 S1 SND 6 Wire, 1 Stage ooling, 2 Stage Heat esidential Heat Pump with b eversing Valve 1 Stage ooling, with 2 stage Heat 5 ELE (FAN) S2 S+5 S1 SND W1/O/B HP B O NO (FAN) 6 onductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac common 24 vac return Fan elay ompressor elay eversing Valve 2nd stage heat circuit b Page 5.5

W3 DE W1 Y2 ( ONLY) INSTALL IDITY MODULE WITH SENSIN ELEMENT OUTWAD ELE HP B O S2 S+5 S1 SND Adding a 2nd Stage of ooling () and 3rd Stage of Heating () 5 S2 S+5 S1 SND W1/O/B W3 (FAN) DE NO Y2 ( ONLY) 3rd Stage Heat 2nd Stage ooling Y2 W3 Page 5.6

W3 PO DE W1 Y2 ( ONLY) 2 4 6 8 X Z 1 INSTALL IDITY MODULE WITH SENSIN ELEMENT OUTWAD 1 3 5 7 9 Y ELE HP B O S2 S+5 S1 SND 2 1 4 3 6 5 8 7 X 1 9 Z Y Adding a Humidification System () and Dehumidification System ()*. 5 S2 S+5 S1 SND W1/O/B W3 DE NO (FAN) NO Y2 ( ONLY) Humidity Module (Sold Separately) Dehumidification System Humidification System * equires Humidity Module. Page 5.7

SETION 6 Test Operation Turn the power on to the Heating/Air onditioning system. Press the MODE button repeatedly until the icon appears on the display. Press the 6 Up or Down buttons until the set temperature is 10 degrees above room temperature. The furnace should turn on. Press the MODE button repeatedly until the icon appears on the display. Press the Up or Down buttons until the set temperature is 10 degrees below room temperature. The air conditioner should turn on. NOTE: Most equipment has a time delay of 5 minutes between cool cycles. This feature is defeatable on the thermostat. onsult the Owner's Manual under Setup, cycles per hour. Press the UP button until the setpoint is equal to the room temperature. Press the FAN button to Fan On. The fan should turn on and run continuously. Page 6.1

SETION 7 alibrating the Thermostat Sensors Under normal circumstances it will not be necessary to adjust the calibration of the temperature and humidity sensors. If calibration is required, please contact a trained HVA technician to correctly perform the following procedure. 7 MODE MODE FAN Place the thermostat in the OFF mode. Press and hold the MODE button. While holding the MODE button, press and hold the FAN button for 5 seconds. All icons will appear on the display. I2:00 Su OFF I8:88 Am Pm HI88 Program Pm StartStop SuMoTuWeThFrSa DeHumidify Service Filter Outside OFFON Vacation Morning AUX DayNight LO Evening FanOnI88Setup 88 PESS TWIE THEMOSTAT SENSO Press the UP and DOWN buttons at the same time twice. The thermostat temperature will be displayed and may be calibrated using the UP or DOWN buttons. ALIBATE EMOTE SENSO MODE Press the MODE button once. The remote sensor temperature will be displayed and may be calibrated using the UP or DOWN buttons. If a remote sensor is not installed, only dashes will appear. Outside ALIBATE IDITY SENSO MODE Press the MODE button once. The relative humidity at the thermostat will be displayed and may be calibrated using the UP or DOWN buttons. ALIBATE After calibration is complete, press the MODE button once to return to normal operation. Page 7.1

SETION 8 TroubleShooting SYMPTOM: The air conditioning does not attempt to turn on. AUSE: The compressor timer lockout may prevent the air conditioner from turning on, for a period of time. EMEDY: onsult the Owner's Manual in the Setup section to defeat the cycles per hour and compressor timeguard. SYMPTOM: The display is blank. AUSE: Lack of proper power. EMEDY: Make sure power is turned on to the furnace and that you have 24vac between & W. If is used, 24vac between &. SYMPTOM: The air conditioning does not attempt to turn on. AUSE: The cooling setpoint is set too high. EMEDY: onsult the Owner's Manual in the Setup section to lower the cooling setpoint limit. SYMPTOM: The heating does not attempt to turn on. AUSE: The heating setpoint is set too low. EMEDY: onsult the Owner's Manual in the Setup section to raise the heating setpoint limit. 8 Page 8.1

TroubleShooting SYMPTOM: When controlling a residential heat pump, and asking for cooling, the heat comes on. AUSE: The thermostat reversing valve jumper is set for b. EMEDY: Set the reversing valve jumper for O. See pages 5.4 and 5.5. 8 SYMPTOM: When calling for cooling, both the heat and cool come on. AUSE: The thermostat equipment jumper is configured for HP and the HVA unit is a as/electric. EMEDY: Set the equipment jumper for as. See pages 5.2 and 5.3. Page 8.2 P/N 88-598 ev. 1