W43A Humidistat. Features and Benefits

Similar documents
System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Powers TM Controls ET 134 Line Voltage Room Thermostats

A19, A28 Series Thermostats for Agricultural Buildings

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

T500 Series Non-Programmable Thermostats

MR3CCUHV Temperature/Defrost Control

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

FS80-C Flow Switch. Features and Benefits. Allows user select the setting according the needs of system

TK-1001, 1101, 1201, 1301, 1601

T4398A,B Precision Electric Heating Thermostat

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

TM-3100 Series Room Temperature Sensor

TP970 Series CONVERTASTAT Kits

Location Requirements

A99B Series Temperature Sensors

TK-1801, TK-1811 TK-1801, TKR-1811

TEC210x-2 Series Networked Thermostats

TEC2100 Series Networked Thermostats

RLD-H10P Refrigerant Leak Detector

RLD-H10G Refrigerant Leak Detectors

TC-5231 Series, TC-5232, & TC-5241 Series

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

A11 Series Low Temperature Cutout Controls

T874 Multistage Thermostat and Q674 Subbase

The T6140A,B Remote Bulb Temperature Controller

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Powers Controls ET 134 Low Temperature Detection Thermostat

Series A28 Two stage Thermostats. Feature and Benefits

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

A99B Series Temperature Sensor

T4098A,B Deluxe Electric Heat Thermostats

V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

ACT2-CS Convenience Store Controller

P266 Series Single-Phase Condenser Fan Speed Control

CP CP

Two-Position Electric Duplex Room Thermostats

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

T7079A,B Solid State Remote Temperature Controllers

T4398A,B High Performance Electric Heat Thermostats

Model Smart Digital Humidistat

Installation Instructions

ELECTRONIC HUMIDISTAT: H200

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

Safety, Installation, and Operation Manual

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

Commercial/Industrial Combustion Control Level Three Announcement

Powers Controls Low Temperature Detection Thermostat

! WARNING. Before using product, read and understand instructions.

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

VENTURI NOZZLE SYSYTEM Specification Sheets ALL STAINLESS STEEL COMPRESSED AIR NOZZLE HUMIDIFIERS. With ON/OFF or Proportional Controls

Wiring Instructions. High-Capacity Steam Humidifiers

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

L62GB BASO Safety Shutoff Device

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

System 350 W351P Electronic Proportional Plus Integral Humidity Control

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

ELECTRONIC HUMIDISTAT: H270

A-4400 Series Refrigerated Air Dryers for Pneumatic Control Systems

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

1F98EZ-1421, Easy Install

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

INSTALLATION & USER MANUAL

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Tools Required Small, flat-head screwdriver Phillips screwdriver (for mounting hardware) Wire stripper and cutter

! WARNING. Before using product, read and understand instructions.

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

T834C Heating-Cooling Thermostat

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Safety & Installation Instructions

Schneider Electric Erie T155 Series

TECHNICAL BULLETIN. Model Smart Digital Humidistat. Installation and Owner's Manual. General Description

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

! WARNING. Before using product, read and understand instructions.

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Safety & Installation Instructions

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

T6984F,G Electronic Floating Control Thermostats

Thermostat KPU. Data sheet

H1008A,D Automatic Humidity Controls

Install Guide 3M-10 ENGLISH

TEC1100 Series Thermostats

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

5SLR52XXD-B Series Fan UL Model No. : 5SLR52. Owner s Guide and Installation Manual

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

MICRO SWITCH BAF/DTF Series

ONX908FCT-4B/220V/RC FAN COIL THERMOSTAT

Model 1750A/ 1770A Dehumidifier Installation Instructions

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Transcription:

Master Catalog 125 Humidity Controls Section W Product/Technical Bulletin W43A Issue Date 1095 W43A The W43A controls humidifying and/or dehumidifying equipment. Typical uses include the control of humidity by ventilation, air conditioning, humidifiers, and dehumidifiers in residential, commercial, and industrial installations. The W43A has Single-Pole/Double-Throw (SPDT) snap-acting contacts rated to switch 1/4 hp motors. It has a wide setpoint range of 0 to 70% Relative Humidity (RH), as well as off dial positions for humidification and dehumidification. The differential of the W43A is fixed at approximately 6% RH. Figure 1: W43A with Vertical Faceplate Features and Benefits Human Hair Sensing Element 1/4 hp (6A) Rated Contacts High/ow Adjustable Knob Range Stops Enclosed Pennswitch Mounting Plate Provides stable, accurate measurement Permits direct operation of many fans in commercial applications Allows adjustments within a desired range Provides dust protection for contacts Allows easy mounting and wiring without removing the cover 1995 Johnson Controls, Inc. 1 Part No. 24-8466-1, Rev. Code No. IT-125715

I ntroduction IMPORTANT: The W43A is designed for use only as an operating control. Where an operating control failure would result in personal injury and/or loss of property, it is the responsibility of the installer to add devices (safety, limit controls) or systems (alarm, supervisory systems) that protect against, or warn of, control failure. The W43A provides SPDT control for use on low or line voltage applications. It has a thermoplastic cover with Allen-head locking screw to discourage unauthorized tampering. The sensing element consists of carefully selected and processed human hair. An adjusting knob and easy-to-read dial allow quick selection of the desired setpoint. The humidistat is supplied with the faceplate installed for vertical mounting and knob adjustment. However, a horizontal faceplate is enclosed for horizontal mounting and knob adjustment if desired. Humidity Settings The humidistat has a setpoint range of 0 to 70% RH, as well as humidification off (HUM OFF) and dehumidification off (DEH OFF) positions. At the HUM OFF position, the C to terminal circuit is open and the C to H terminal circuit is closed. At the DEH OFF position, the C to H terminal circuit is open and the C to terminal controls the humidification equipment. At any given setpoint, the C to circuit closes on a decrease in relative humidity, and the C to H circuit closes on an increase in relative humidity. The usual setting in winter is 30 to 40% RH. ower settings may be necessary in extremely cold weather to prevent condensation on windows, doors, etc. The same setting should be used where reduction of humidity by means of exhaust fans is provided in wellconstructed homes. Summer settings on air conditioning or dehumidifying equipment will usually be near 50% RH. The suggested indoor humidity at 70 F (21 C) for residential applications on humidifying or dehumidifying equipment in winter is shown in Table 1. Table 1: Humidity Settings Outside Temperature -20 F (-29 C) and Below -10 F (-23 C) Suggested Humidity Setting 15% RH 20% RH 0 F (-18 C) 25% RH 10 F (-12 C) 30% RH 20 F (-7 C) 35% RH Above 20 F (-7 C) I nstallation Supplies Needed 40% RH or Higher as Desired 2 x 4 in. (51 x 102 mm) wall box (field supplied) 3-wire cable (field supplied) screwdriver (slotted standard) marking pencil wire strippers ocation Considerations ocate the W43A as follows: on an inside wall away from ranges, sinks, bathrooms, or other areas of extreme moisture and temperature where natural air circulation is unrestricted where lamps, sunlight, fireplaces, heat registers, radiators, concealed air ducts or pipes, or room occupants will not affect its operation 2 W43A Product/Technical Bulletin

Dimensions 1.59 40 6-32 Mounting Screws (2 Places) 1.20 30 0.69 18 4.71 120 2.34 59 3.22 82 0.80 20 2.96 75 1.27 32 0.25 6 1.28 33 1.41 36 Figure 2: W43A Dimensions (in./mm) Mounting and Wiring Mounting Plate ocking Screw Grounding Screw Adjustment Knob Mounting Plate Wall Box Optional Concealed Adjustment Faceplate Vertical Faceplate Cover ocking Screw Figure 3: W43A W43A Product/Technical Bulletin 3

IMPORTANT: Do not remove the humidistat cover during installation. The sensing element must be carefully protected against accidental damage. All wiring and mounting can be completed without removing the cover.! CAUTION: Shock hazard. Disconnect power supply before wiring connections are made to prevent electrical shock or possible damage to the equipment. To mount the W43A : 1. Select the proper mounting location (refer to the ocation Considerations section) and install a vertical or horizontal wall box 4 to 5 feet (1.2 to 1.5 m) above the floor. 2. Run conduit or cable, as required by national and/or local electric codes, from the wall box to the equipment to be controlled. eave approximately 6 in. (152 mm) of wire for connection to the humidistat terminals. 3. Remove the humidistat mounting plate by loosening the mounting plate locking screw (see Figure 3), and lifting and removing the plate from the base. 4. Pull wires through the mounting plate and fasten the plate, grounding screw end up, to the wall box with the screws provided. 5. Strip the wires and connect to the proper terminals on the back of the humidistat. See Wiring Diagrams section. Note: Use the terminal screws furnished (8-32 x 1/4 in. binder head). Substitution of other screws may cause problems in making proper connections. 6. Connect the grounding provision of the humidistat to the branch circuit ground. 7. Hook the two slots in the humidistat base over the projections on the mounting plate and swing the humidistat into place. Push the wires back flush into the wall box. 8. Securely tighten the mounting plate locking screw. Optional Horizontal Faceplate Installation 1. Mount and wire the humidistat according to the steps outlined in the Installation section. 2. Pull the adjustment knob off the humidistat cover. 3. Peel off the backing of the horizontal faceplate. 4. Position the horizontal faceplate over the factoryinstalled vertical faceplate. Be sure to position the plate straight and even over the existing plate. 5. Firmly press the horizontal faceplate onto the humidistat cover. 6. Replace the adjustment knob. Wiring Diagrams Manual Fan Switch Exhaust Fan 120 VAC N Range Relay Kitchen H C Dining Area or Hall Figure 4: Typical Wiring Diagram of a W43A Used to Reduce Excessive Humidity in a Well-Constructed Building by Manual or Automatic Control of Exhaust Fan 120 VAC N H C Dehumidifier Figure 5: Dehumidification Control Wiring Diagram 4 W43A Product/Technical Bulletin

120 VAC 120 VAC N H C Humidifier Figure 6: Humidification Control Wiring Diagram N H C Manual Changeover Switch Humidifier Dehumidifier Figure 7: Schematic Wiring Diagram of a W43A Automatically Operating a Humidifier or Dehumidifier as Selected by Manual Changeover Switch 120 VAC N H C Fan Speed Selector with Manual "On/Off" Switch Exhaust Fan Motor Figure 8: Schematic Wiring Diagram of a W43A Automatically Operating an Exhaust Fan at Full Speed to Control Excessive Humidity; a Combination Speed Control and On/Off Switch Permits Manual Operation of Exhaust Fan at Selected Speeds Range Stops High and low range stops of the humidistat can be field adjusted as desired. Use the following procedures to set the high and low range stops. High Range Stop 1. Set the adjustment knob to the maximum desired RH setting. 2. Pull the adjustment knob off the humidistat cover. 3. oosen the bottom cover screw and remove the humidistat cover.! CAUTION: Equipment damage hazard. Avoid contact with human hair sensing element. Contact with hair element can affect control accuracy and/or product life. 4. While holding the dial firmly in place, keeping the setting in line with the calibrating mark, depress the tab A (see Figure 9) and rotate it counterclockwise until it is against the stop pin C. 5. Release the tab making sure it fits into the nearest notch. 6. Replace the humidistat cover, tighten the bottom cover screw, and replace the adjustment knob. 7. Rotate adjustment knob to desired normal operating setpoint. ow Range Stop 1. Set the adjustment knob to the minimum desired RH setting. 2. Pull the adjustment knob off the humidistat cover. 3. oosen the bottom cover screw and remove the humidistat cover. W43A Product/Technical Bulletin 5

! CAUTION: Equipment damage hazard. Avoid contact with human hair sensing element. Contact with hair element can affect control accuracy and/or product life. 4. While holding the dial firmly in place, keeping the setting in line with the calibrating mark, depress the tab B (see Figure 9) and rotate it clockwise until it is against the stop pin C. 5. Release the tab making sure it fits into the nearest notch. 6. Replace the humidistat cover, tighten the bottom cover screw, and replace the adjustment knob. 7. Rotate adjustment knob to desired normal operating setpoint. Calibrating Mark Sensing Element 70 50 40 30 20 DEH OFF 10 HUM OFF Stop Pin "C" High Range Stop Tab "A" ow Range Stop Tab "B" Figure 9: W43A Range Tabs and Stop Dial ock The high range stop and low range stop can be set to keep the adjustment knob from rotating. To lock the dial: 1. Set the adjustment knob to the desired RH setting. 2. Pull the adjustment knob off the humidistat cover. 3. oosen the bottom cover screw and remove the humidistat cover.! CAUTION: Equipment damage hazard. Avoid contact with human hair sensing element. Contact with hair element can affect control accuracy and/or product life. 4. While holding the dial firmly in place, keeping the setting in line with the calibrating mark, depress the tab A and rotate it counterclockwise until it is against the stop C. Depress the tab B and rotate it clockwise until it is against the stop pin C. See Figure 9. 5. Make sure each tab fits into the notch closest to the stop. 6. Replace the humidistat cover, tighten the bottom cover screw, and replace the adjustment knob. Checkout Procedure Before applying power, make sure installation and wiring connections are according to job specifications. After all necessary adjustments and electrical connections have been made, put the system into operation and observe at least three complete operating cycles before leaving the installation. Repairs and Replacement Field repairs must not be made except for replacement of the adjustment knob or mounting plate. Refer to Table 4: Replacement Parts for replacement part ordering information. For a replacement W43A, contact the nearest Johnson Controls representative. 6 W43A Product/Technical Bulletin

O rdering Information Table 2: Ordering Information Item Product Code Number W43A-14C Accessories Brand Name Faceplates Brand name faceplates are available on quantity orders. Contact Customer Service. Guards Plastic, wire, or cast aluminum guards are available at extra cost. See the GRD Series in the Johnson Controls HVAC/Refrigeration Controls Catalog. Concealed Adjustment Faceplates Concealed adjustment faceplates are available on factory order at no extra cost. For field changeover, use the concealed faceplate kit and install directly over the faceplate on the cover. See Table 3 for ordering information. Table 3: Optional Accessories Item Concealed Adjustment Faceplate, Vertical Mounting Concealed Adjustment Faceplate, Horizontal Mounting Product Code Number PT333-12R PT333-9R Replacement Parts Table 4: Replacement Parts Item Thermoplastic Push On Adjustment Knob Mounting Plate Product Code Number KNB26A-600R PT51A-602R W43A Product/Technical Bulletin 7

Specifications Product W43A-14C Contact Ratings 120 VAC 208 VAC 240 VAC Full oad Ampere 6.0 3.5 3.0 ocked Rotor Ampere 36.0 21.0 18.0 Pilot Duty 125 VA at 24/277 VAC Measurement Range Differential Contact Action Switch Sensing Element 0 to 70% RH Fixed at approximately 6% RH SPDT Snap-acting Contacts in a Dust-protected Enclosure Selected Human Hair Material Base: 0.050 in (1.27 mm) Cold Rolled Steel Cover: Beige Thermoplastic Finish Base: Zinc Plate Dichromate Dipped Cover: Brown Markings on Gold Anodized Aluminum Mounting Wiring Terminals Minimum Ambient Temperature Maximum Ambient Temperature Agency istings Dimensions (H x W x D) Shipping Weight Vertical or Horizontal 2 x 4 in. (51 x 102 mm) Wall Box arge 8-32 x 1/4 in. Binder Head Screws 40 (4.4 C) 100 F (38 C) U Guide No. XAPX; File E6688 CSA Class No. 4813 02: File R948 4.71 x 2.96 x 2.94 in. (120 x 75 x 75 mm) 0.9 lb (0.4 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53201 Printed in U.S.A. 8 W43A Product/Technical Bulletin