SYSTEM. field cuttable LLED8000

Similar documents
SYSTEM. field cuttable. lipleds 8200 Series

SYSTEM FIELD CUTTABLE SERIES

SERIES. LINE OF LIGHT (No Pixelation) FLEXIBLE DIRECT VIEW LINE VOLTAGE 150 MAXIMUM RUN LOW VOLTAGE 32 MAXIMUM RUN OUTDOOR RATED

EFFICIENT LONG LIFE & ENERGY SERIES

PRELIMINARY 2000K PERFORMANCE. CRI Lumen Maintenance Binning Tolerance Warranty

OPTIONS. Mounting LUMEN OUTPUT. Flat. Round PERFORMANCE. Color Temperature. Lumen Maintenance Binning Tolerance Warranty + +

OPTIONS. Mounting LUMEN OUTPUT FLAT. 3000K lm/ft PERFORMANCE. Lumen Maintenance SERIES SHAPE COLOR VOLTAGE LENGTH CONFIGURATION

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

FLEX DC SIDE EMITTING

ACCESSORIES. Mounting LUMEN OUTPUT 2400K 1 PERFORMANCE. Lumen Maintenance. Warranty SERIES SHAPE COLOR VOLTAGE LENGTH CONFIGURATION

EcoSystem H-Series Ballasts

CRENSHAW. Board and driver LED standard systems for ceiling mounts. Crenshaw LED. Standard Ceiling Options

Performance Chart Electrical Data

Performance Chart Electrical Data

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

Fino Healthcare. Asymmetric Wall Mount Indirect LED

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

LIGHT CHANNEL TRIM 1.6

EcoSystem H-Series 347 V~ Ballast Overview

Ivalo Lumaris LED Linear Lighting

LIGHT CHANNEL 45 COMPLETE FIXTURE

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

LIGHT CHANNEL.6 MILLWORK COMPLETE FIXTURE

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Fino. Asymmetric Wall Mount Indirect LED

NOVA CEILING WALL GRAZER WITH REMOTE POWER

Grüv Flare Regressed. Recessed Linear LED

M60 LED Recessed Wet Location

Ivalo Lumaris LED Linear Lighting

12 inches to 120 inches

Grüv Flare Regressed. Recessed Linear LED

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

3.75 Gyro Shift Multiples Single Head

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

Performance Chart Electrical Data

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Ivalo Lumaris LED Linear Lighting

Classix 6" 6" Round Adjustable C3

Performance Chart Electrical Data

SECTION INTERIOR LIGHTING

CRENSHAW. LED Lamping Guide. Crenshaw LED. Farrell Hall, Wake Forest University

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

Performance Chart Electrical Data

Classix 6" 6" Round Adjustable C3M

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

Dimensions (111mm) (111mm) 3 (76mm)

Evoke Square Downlight

Linea 1.5. Linear Direct Wall Wash LED

LED Linear Design Highlights

IBLED SERIES 4' PROJECT: FEATURES AND SPECIFICATIONS LINE DRAWING

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

EcoSystem H-Series Ballasts Overview

Classix 6" 6" Round Adjustable C3

Essenza. Round Downlights

Classix 6" 6" Round Lens Wall Wash

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

Evoke Square Adjustable HP

Evoke Square Downlight

Evoke Round Adjustable C3

PRODUCT CODE DRIVER FACEPLATE FINISH WATTAGE COLOR TEMP VOLTAGE

Evoke Square Adjustable HP

OPTOTRONIC Power Supply OT96W/24V/UNV/DIM

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

Essenza. Square Downlights

LHBXD LED Linear High Bay

Evoke Square Adjustable C3M

PRODUCT CODE DRIVER FACEPLATE FINISH WATTAGE COLOR TEMP VOLTAGE

Evoke Square Downlight

Hornet HP. Square Glass Downlight

Lamp: K K K K K K

Hornet HP. Round Glass Downlight

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

JLLP DESIGN AND CONSULTING

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

Lamp: K K K K K K

VESICA LINEAR SUSPENDED VES L

Evoke 2.9" HP. 2.9" Square Downlight

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

DHL-LP-LED Low Profile LED Linear High/Low Bay

Etch 2' x 2' Recessed LED

Lamp: Average Lamp Life: 50,000 hours. 24VDC Power Supply (sold separately): PSB-4X96W VDC VAC input, 4x96 watt output

Running Magnet 2.0 Suspension Down High-tech LED lighting system for interior architecture

Claude Indirect Wall WALL

Catalog Number. Notes

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Evoke 2.9" HP. 2.9" Square Downlight

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

12 inches to 120 inches. Applications: Indoor and Wet Location - Task lighting, under/above cabinet, cove and retail. ETL listed for wet location.

LINKABLE UNDERCABINET

Hornet HP. Semi-Recessed 4-Light Square Multiple

TROFFER RETROFIT KIT (TRK)

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Transcription:

lipleds Series Specification Grade LLED8000 CRI > 90 DIMMING Forward Phase (TRA) 0-10V (TRA-E) Hi-Lume A Series (2 Wire) Hi-Lume 1% (3 Wire) EFFICACY 95 Lumens Per Watt field cuttable SYSTEM L70 LED LIFE 60,000 hrs. DRY OR WET (IP65 or IP67) LOCATION UL2108, CSA C22.2#9 UL8750, CSA250 lipleds TM Series is a field cuttable system designed with long life, energy efficient LEDs that result in low maintenance installations. lipleds TM is excellent to illuminate areas for cove lighting, accent lighting, backlighting, and other indirect lighting applications. MADE IN USA Lighting for the Professional Designer

Applications VOLTAGE Lamp Type Accent, Decorative Lighting 24VDC LEDs lipleds 8000 SERIES FEATURES lipleds Specification Grade Tape series is a 24 volt system that requires a 24VDC (secondary side) transformer. The standard primary side voltage on our transformers is 120V or 277V. Consult factory for other primary side voltages. DIMMING Length MOUNTING CRI > 90 efficacy VIEWING ANGLE L70 LED LIFE MAXIMUM RUN *1 (5 Amps) LISTING Forward Phase (TRA) 0-10V (TRA-E) Hi-Lume 1% A Series (2 Wire) Hi-Lume 1% (3 Wire) Built to Order Mounting Clips or Mounting Channel 95 Lumens per Watt 120 Degrees 60,000 hrs. 18' (6.5W) 21 (5.5W) 26 (4.5W) 33 (3.6W) 36 (1.5W, 2.5W) Dry or Wet (IP65 or IP67) Location UL2108, CSA C22.2#9 UL8750, CSA250 2 lipleds Series Specification Grade LLED8000 800.921.CALI California Accent Lighting, Inc.

PERFORMANCE Color Vector Graphic TM-30 GRAPHIC SHIFTS (%) HUE BIN Rƒ CHROMA HUE 1 79-10% 0% 2 79-8% 8% 3 70-2% 14% 4 85 2% 8% 5 90 5% 5% 6 90 6% -3% 7 84-2% -8% Polar Graph 43 32 21 11 2 8 89-6% -4% 9 85-6% 3% 10 78-6% 11% 11 77 2% 14% 12 79 6% 9% 13 88 8% -7% 14 67 4% -20% 15 84 0% -10% 16 75-7% -14% 1 Chromaticity Diagram LED NUMBER LED-2.4K LED-2.7K LED-3.0K LED-3.5K LED-4.0K LED-4.5K LED-A LED-R LED-G LED-B Description 2400K Incand. White 2700K Warm White 3000K Warm White 3500K Neutral White 4000K Neutral White 4500K Neutral White Amber Red Green Blue California Accent Lighting, Inc. calilighting.com lipleds Series Specification Grade LLED8000 3

Lens and SINGLE Light Strip LLED8000 light strip is field cuttable every 2 for easy installation without rigorous requirements. 8' Maximum extrusion and lens length (Dry Location field cuttable) Dry Location.31 Watts per Foot 1.5W, 2.5W.07 Wet (IP65 or IP67) Location *3 1.5W, 2.5W *7.52 3.6W, 4.5W *7.20.36 Lenses Clear Semi-Frosted Frosted Optics 15, 30, 45, 60 Applicable to: LLED8000-SR LLED8000-L LLED8000-UCS See individual submittal for more information..31.52 Watts per Foot 3.6W, 4.5W, 5.5W, 6.5W 5.5W, 6.5W *7.78.39.75 1.5W (Max 36'), 2.5W (Max 36').31" 3.6W (Max 33'), 4.5W (Max 26'), 5.5W (Max 21'), 6.5W (Max 18').39" Specify PRODUCT CODE Series OPTICS Watts per Foot DIMMING LAMP dry OR wet FINISH LLED8000 *8 LLED8000-RPM LED-2.4K Indoor Natural Silver Clear Lens 1.5 Watts (1.5W) Forward Phase (DRY) (NA) *2 (CL) *9 (143 Lumens/ft) (DM) LLED8000-CM *8 LLED8000-SQC LED-2.7K Polished Outdoor (PA) IP65 LLED8000-CMC LLED8000-SQL 50% Semi-Frosted Lens LED-3.0K (WET) *6 White (SF) 2.5 Watts (2.5W) 0-10V (WH) (238 Lumens/ft) (10V) Satin LLED8000-CR LLED8000-SR LED-3.5K Outdoor (SA) IP67 LLED8000-L LLED8000-SRT LED-4.0K (WET-IP67) 100% Frosted Lens 3.6 Watts (3.6W) *6 Black Hi-Lume 1% A (BK) LLED8000-LPFF LLED8000-ST (F) (342 Lumens/ft) (2 Wire) *3 LED-4.5K Green (GN) LLED8000-LPL LLED8000-UC *8 (428 Lumens/ft) (3 Wire) *4 LED-R Silver *5 (SR) LLED8000-LPG LLED8000-STL LED-A Red 4.5 Watts (4.5W) Hi-Lume 1% (RD) LLED8000-LPR LLED8000-UCS 5.5 Watts (5.5W) Leave Blank LED-G *5 Custom (523 Lumens/ft) For Powder Coat LLED8000-LR LLED8000-VR Non-dimming LED-B *5 (PC) LLED8000-OL LLED8000-RC LLED8000-RCR LLED8000-WLPR LLED8000-WMC LLED8000-WMR 6.5 Watts (6.5W) (618 Lumens/ft) LLED8000-RME EXAMPLE: LLED8000-CL-3.6W-DM-LED-3.5K-WET-WH *1 Maximum run based on 4 amps for class II applications: 14 (6.5W), 17 (5.5W), 21 (4.5W), 26 (3.6W), 36 (1.5W, 2.5W) *2 Standard finish - Natural Silver if left blank (finish does not apply to LLED8000, LLED8000-ST or LLED8000-STF) *3 40 watt max Hi-Lume Lutron A #LTEA4U1UKL-CV240 *4 40 watt max Hi-Lume Lutron 1% #L3DA4U1UKL-CV240 *5 Only available in 2.5W and 5.5W *6 Run lengths required for Wet Location and IP67 products (To ensure proper seal) *7 Wet location tube measures.52 x.20" for 4.5W for 1.5W, 2.5W, and 3.6W Tube size increases to.52 x.36 for 4.5W and increases to.78" x.75" for 5.5W and 6.5W *8 No optics available *9 Standard lens - Clear if left blank 4 lipleds Series Specification Grade LLED8000 800.921.CALI California Accent Lighting, Inc.

SURFACE MOUNT ±.015" Tolerance LLED8000 LLED8000-STL Only for 1.5W, 2.5W LLED8000-ST 1.5W, 2.5W, 3.6W, 4.5W 5.5W and 6.5W.07.31 LLED8000-UC LLED8000-L 15, 30, 45, 60 LLED8000-LPFF No Lens LLED8000-SR 15, 30, 45, 60 LLED8000-LPL LLED8000-WMC RECESS MOUNT LLED8000-LPR All Wattages LLED8000-UCS 15, 30, 45, 60 LLED8000-WLPR LLED8000-LR LLED8000-WMR LLED8000-RME LLED8000-CR LLED8000-RCR LLED8000-LPG 1.51 1.25 Walk Over CORNER MOUNT LLED8000-CM LLED8000-VR 1.13 LLED8000-CMC No Lens LLED8000-SQC PENDANT MOUNT (All pendant mount products can also be surface mounted) LLED8000-SQL LLED8000-SRT LLED8000-HC.92 2.34 LLED8000-RC 1.13 LLED8000-RPM LLED8000-OL 1.25 California Accent Lighting, Inc. calilighting.com Closet Rod lipleds Series Specification Grade LLED8000 5

LLED8000.26.12.94.12 1.0.78.94 #LLED8000-MCS (Dry Location) #LLED8000-MCS (Wet Location) LLED8000-UC.56.56 No Lens LLED8000-SR 0.79 0.53 0.82.56 0.56 0.94 1.0 Specify Length X X = Custom Length 0.94 LLED8000-L 0.70 1.75 0.70 0.93 0.93 0.55 0.36 0.90 0.84 #LLED8000-XX-MC #LLED8000-XX-MC-1 0.55 0.55 1.50 0.90 #LLED8000-XX-MC-2 LLED8000-STL 0.90 #LLED8000-XX-MC-3 (Adjustable) #LLED8000-XX-MC-4-X (Specify Length Maximum 2') LLED8000-ST 8 8 1.0 7.5.78 #LLED8000-STL-MC 1.42.78 #LLED8000-STL-uc (Mounting Channel) #LLED8000-ST-uc (Mounting Channel) 1.0 #LLED8000-ST-MC-1 LLED8000-LPL Minimum Bend Diameter: 24 Note: Flexible channel only bends vertically Flexible Aluminum Channel (#LLED8000-LPL) #LLED8000-LPL-MC-1 LLED8000-LPFF LLED8000-WMC #LLED8000-XXXX-MC RECESS MOUNT Mounting Options LLED8000-LPR LLED8000-LR LLED8000-UCS Embedded Channel LLED8000-WMR Embedded Channel #LLED8000-SPR-MC LLED8000-RME LLED8000-CR Dropped Ceiling Recessed Channel Toe Kick Concrete or Wood Floor LLED8000-RCR LLED8000-LPG.25.29 Glass (thickness 3/16" ~ 1/4").80.29.59 4.00 LLED8000-WLPR.80.80 #LLED8000-RCR-MC 6 lipleds Series Specification Grade LLED8000.26.55 Glass Mount #LLED8000-RCR-MC-H 800.921.CALI California Accent Lighting, Inc. ACCESSORIES SURFACE MOUNT Mounting Options

CORNER MOUNT Mounting Options LLED8000-CM.61.69 #LLED8000-CM-MC-1 1.0.50 1.05.90 #LLED8000-CM-MC-2.61 1.50 1.78 #LLED8000-CM-MC-3 (Adjustable) 1.05.50 Specify Length X X = Custom Length.90 #LLED8000-CM-MC-4-X (Specify Length Maximum 2') ACCESSORIES.98 LLED8000-CMC.56 Specify Length X=Length.98 1.41.50 1.52 1.41.50.96 #LLED8000-CMC-MC-1.96 #LLED8000-CMC-MC-2 1.50 #LLED8000-CMC-MC-3 (Adjustable).96 #LLED8000-CMC-MC-4-X (Specify Length Maximum 2') LLED8000-VR.70.78 #LLED8000-XX-MC-1 LLED8000-SQC.83.83.75 #LLED8000-SQC-MC PENDANT MOUNT Mounting Options (All pendant mount products can also be surface mounted) LLED8000-SQL LLED8000-HC LLED8000-OL.92 X 2.34 LLED8000-SRT LLED8000-RC 1.13 1.25 5.0 #LLED8000-XXX-CN-XX (XX=Finish) #LLED8000-XXX-PM-X (X=Specify Length) LLED8000-RPM Closet Rod #LLED8000-MB POWER CONNECTORS - SINGLE ROW CONTINUOUS CONNECTORS - SINGLE ROW.67.07.56.33.43 Power Connector (#LLED8000-PC) 3 Continuous Connector (#LLED8000-CC) Power Connector White Jacket (#LLED8000-PC-w) Continuous Connector White Jacket (#LLED8000-CC-W) Power Connector Black Jacket (#LLED8000-PC-B) Continuous Connector Black Jacket (#LLED8000-CC-B) California Accent Lighting, Inc. calilighting.com lipleds Series Specification Grade LLED8000 7

transformer Electronic: 0-10V Dimming Transformer (Indoor or Outdoor Rated) Product Code Max. Watts Input Output Input AC Current Power Factor Width (W) Height (H) Depth (D) TRA16-E TRA16-E-UNV-24VDC-10V 16 120V-277V 24VDC.2A / 277VAC or.4a / 120VAC.92 12.7 3.43 2.66 TRA25-E TRA25-E-UNV-24VDC-10V 25 120V-277V 24VDC.2A / 277VAC or.4a / 120VAC.92 12.7 3.43 2.66 TRA40-E TRA40-E-UNV-24VDC-10V 40 120V-277V 24VDC.25A / 277VAC or.6a / 120VAC.92 12.7 3.43 2.66 TRA60-E TRA60-E-UNV-24VDC-10V 60 120V-277V 24VDC.3A / 277VAC or.64a / 120VAC.92 12.7 3.43 2.66 TRA80-E TRA80-E-UNV-24VDC-10V 80 120V-277V 24VDC.4A / 277VAC or.85a / 120VAC.94 12.7 3.43 2.66 TRA90-E TRA90-E-UNV-24VDC-10V 90 120V-277V 24VDC.4A / 277VA or.85a / 120VAC.95 12.7 3.43 2.66 TRA100-E TRA100-E-UNV-24VDC-10V 100 120V-277V 24VDC.5A / 277VAC or 1.2A / 120VAC.93 15.7 4.42 2.92 TRA120-E TRA120-E-UNV-24VDC-10V 120 120V-277V 24VDC.55A / 277VAC or 1.4A / 120VAC.93 15.7 4.42 2.92 TRA150-E TRA150-E-UNV-24VDC-10V 150 120V-277V 24VDC.7A / 277VAC or 1.7A / 120VAC.92 15.7 4.42 2.92 TRA185-E TRA185-E-UNV-24VDC-10V 185 120V-277V 24VDC.8A / 277VAC or 2.1A / 120VAC.92 15.7 4.42 2.92 TRA240-E TRA240-E-UNV-24VDC-10V 240 120V-277V 24VDC 2A / 277VAC or 4A / 120VAC.95 15.7 4.42 2.92 TRA320-E TRA320-E-UNV-24VDC-10V 320 120V-277V 24VDC 1.45A / 277VAC or 3.5A / 120VAC.94 15.7 4.42 2.92 ** Class II 24VDC TRA16-E, TRA25-E, TRA40-E, TRA60-E, TRA-80E, TRA90-E Dimming Protocol (0-10V) TRA-E Compatible Dimmers Technical Requirements For Control Equipment (0-10V Protocol) The output current level of the dimmable driver is controlled by DC voltage (0-10V) applied to the control terminals (blue and white). The light output of LEDs is controlled by the amount of output current from the dimmable driver. The control device must be capable of sinking a DC current flow from the driver. The maximum amount under any condition is 500 microamps (ua) per driver. The control terminals of the dimmable driver are isolated from the power lines and are suitable for use as Class 2 wiring. Multiple drivers are desired for use with same control device, the control terminals may be connected in parallel in a bus configuration. Since the control bus is Class 2 wiring, all control devices that are connected to the power line must have proper isolation between the power line and the control terminals/bus. The control device, which intends to control more than one dimmable driver, must be capable of sinking the total current supplied to control bus by the drivers. If the control terminals/bus is shorted in any case, the current on the control terminals/bus will be 500 microamps (ua) per driver maximum. If the control terminals are opened, the voltage on the control terminals will then be 10V ± 0.5 volt. As a result, dimmable driver supplies maximum output current to LEDs under this condition. The driver is intended for use with control voltages between 0 and 10 VDC. The control equipment must not impose a voltage greater than 11 V peak maximum on the driver control terminals. 120V-277V TRAXXX-E-UNV-24VDC-10V Brown (Hot) Blue (Neutral) Transformer enclosure Red (+) Black (-) TRAXXX-E-UNV-24VDC-10V 24VDC to Lighting White (-) Blue (+) Dimmer (Supplied by others) 0-10V Line 8 lipleds Series Specification Grade LLED8000 800.921.CALI California Accent Lighting, Inc.

transformer Magnetic: Forward Phase Dimming Transformer (Indoor or Outdoor Rated NEMA 3R) - Primary Fusing Included Product Code Max. Watts Input Output Input Current No Load-Full Load Power Factor Width (W) Height (H) Depth (D) TRA5 TRA5-120V-24VDC 5 120V 24VDC.4-1.4 Amps 0.961 1.975 6 1.43 TRA5-277V-24VDC 5 277V 24VDC 0.2-0.6 Amps 0.961 1.975 6 1.43 TRA10 TRA10-120V-24VDC 10 120V 24VDC 0.3-2.2 Amps 0.964 1.975 6 1.43 TRA10-277V-24VDC 10 277V 24VDC 0.12-0.8 Amps 0.964 1.975 6 1.43 TRA20 TRA20-120V-24VDC 20 120V 24VDC 0.3-2.6 Amps 0.979 1.975 6 1.43 TRA20-277V-24VDC 20 277V 24VDC 0.12-1.2 Amps 0.979 1.975 6 1.43 TRA35 TRA35-120V-24VDC 35 120V 24VDC 0.4-4.3 Amps 0.973 1.975 6 1.43 TRA35-277V-24VDC 35 277V 24VDC 0.15-1.8 Amps 0.973 1.975 6 1.43 TRA40 TRA40-120V-24VDC 40 120V 24VDC 0.8-5.3 Amps 0.978 1.975 6 1.43 TRA40-277V-24VDC 40 277V 24VDC 0.3-2.3 Amps 0.978 1.975 6 1.43 TRA50 TRA50-120V-24VDC 50 120V 24VDC 0.8-5.3 Amps 0.978 1.975 6 1.43 TRA50-277V-24VDC 50 277V 24VDC 0.3-2.3 Amps 0.978 1.975 6 1.43 TRA60 TRA60-120V-24VDC 60 120V 24VDC.4-1.4 Amps 0.961 3.00 7.50 2.75 TRA60-277V-24VDC 60 277V 24VDC 0.2-0.6 Amps 0.961 3.00 7.50 2.75 TRA75 TRA75-120V-24VDC 75 120V 24VDC.4-1.4 Amps 0.961 3.00 7.50 2.75 TRA75-277V-24VDC 75 277V 24VDC 0.2-0.6 Amps 0.961 3.00 7.50 2.75 TRA90 TRA90-120V-24VDC 75 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA90-277V-24VDC 75 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA100 TRA100-120V-24VDC 100 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA100-277V-24VDC 100 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA150 TRA150-120V-24VDC 150 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA150-277V-24VDC 150 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA200 TRA200-120V-24VDC 200 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA200-277V-24VDC 200 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA250 TRA250-120V-24VDC 250 120V 24VDC 0.3-2.2 Amps 0.964 4.1875 8 3.25 TRA250-277V-24VDC 250 277V 24VDC 0.12-0.8 Amps 0.964 4.1875 8 3.25 TRA300 TRA300-120V-24VDC 300 120V 24VDC 0.3-2.6 Amps 0.979 4.1875 8 3.25 TRA300-277V-24VDC 300 277V 24VDC 0.12-1.2 Amps 0.979 4.1875 8 3.25 * Class II 24VDC TRA5, TRA10, TRA20, TRA35, TRA40, TRA50, TRA60, TRA75, TRA90 Dimming Protocol (Forward Phase Dimming) TRA Compatible Dimmers Technical Requirements For Control Equipment Magnetic Low Voltage (MLV) - Magnetic (core and coil, toroidal) transformer-supplied low voltage lighting Electrical Characteristics - Inductive Special Requirements - Symmetric cycles (VDC 2), smooth turn off (positive and negative periods are equal for safe MLV transformer operation) TRAXXX-120V-24VDC TRAXXX-277V-24VDC Transformer enclosure Transformer enclosure Red (+) Red (+) Blue (-) Green (Ground) Blue (-) Green (Ground) 24VDC to Lighting 24VDC to Lighting Optional Dimmer (not included) Optional Dimmer (not included) White (Neutral) White (Neutral) Black Dimmed (Hot) Orange (277V) Primary Voltage Line Primary Voltage Line 120VAC 277VAC Forward Phase Dimming Forward Phase Dimming California Accent Lighting, Inc. calilighting.com lipleds Series Specification Grade LLED8000 9

transformer Lutron: Hi-Lume A Series Lutron: Hi-Lume 1% Transformer (Indoor) Product Code Max. Watts Input Output Input Current No Load-Full Load Power Factor Width (W) Height (H) Depth (D) TRA40-E-1%-2 TRA40-E-UNV-24VDC-FP-1%-2WIRE 40 120V-277V 24VDC 0.37A / 120VAC or 0.17 / 277 VAC 0.9 4" 2.62" 4" TRA40-E-1%-3 TRA40-E-UNV-24VDC-FP-1%-3WIRE 40 120V-277V 24VDC 0.37A / 120VAC or 0.17 / 277 VAC 0.9 4" 2.62" 4" DIMMING PROTOCOL (2 Wire - 40 Watt Max Hi-Lume A Series Lutron #LTEA4U1UKL-CV240) Compatible with Energi Savr Node unit with EcoSystem, GRAFIK Eye QS control unit, PowPak dimming module with EcoSystem, and Quantum systems, allowing for integration into a planned or existing EcoSystem lighting control solution. Meets ANSI C62.41 category A surge protection standards up to and including 4 kv. FCC Part 15 compliant for commercial applications at 120 V~ or 277 V~ Dimming Range: 100% to 1%. Operating Voltage: 120 277 V~ at 50/60 Hz. Lifetime: 50,000 hours @: tc = 149 F (65 C)1 for 40 W drivers. For rated warranty, tc not to exceed the maximum rated temperatures listed here. Patented thermal foldback protection. LEDs turn on to any dimmed level without going to full brightness. Non-volatile memory restores all driver settings after power failure. Power Factor: > 0.90 for loads greater than 25 W Standby Power Consumption: < 1.0 W Total Harmonic Distortion (THD): < 20% for loads greater than 25 W. Inrush Current: < 2 A. Inrush Current Limiting Circuitry: eliminates circuit breaker tripping, switch arcing and relay failure. Open circuit protected. Short circuit protected. Turn-on time: 1.5 seconds.2 PWM Dimming Frequency: 550 Hz. DIMMING PROTOCOL (3 Wire - 40 Watt Max Hi-Lume 1% Lutron #L3DA4U1UKL-CV240 Compatible with Energi Savr Node unit with EcoSystem, GRAFIK Eye QS control unit, PowPak dimming module with EcoSystem, and Quantum systems, allowing for integration into a planned or existing EcoSystem lighting control solution. Meets ANSI C62.41 category A surge protection standards up to and including 4 kv. FCC Part 15 compliant for commercial applications at 120 V~ or 277 V~ Dimming Range: 100% to 1%. Operating Voltage: 120 277 V~ at 50/60 Hz. Lifetime: 50,000 hours @: tc = 149 F (65 C)1 for 40 W drivers. For rated warranty, tc not to exceed the maximum rated temperatures listed here. Patented thermal foldback protection. LEDs turn on to any dimmed level without going to full brightness. Non-volatile memory restores all driver settings after power failure. Power Factor: > 0.90 for loads greater than 25 W Standby Power Consumption: < 1.0 W Total Harmonic Distortion (THD): < 20% for loads greater than 25 W. Inrush Current: < 2 A. Case type KL Inrush Current Limiting Circuitry: eliminates circuit breaker tripping, switch arcing and relay failure. Open circuit protected. Short circuit protected. Turn-on time: 1.5 seconds.2 PWM Dimming Frequency: 550 Hz. 10 lipleds Series Specification Grade LLED8000 800.921.CALI California Accent Lighting, Inc.

Tom Colicchio's Heritage Steak, Mirage Hotel Las Vegas, NV

Design Guidelines No exposed wiring or cords required between fixtures. Seamless installation with no potential dark spots. Option A - Straight Runs Detail A Power Connector (#LLED8000-PC) 33" 1.5" Option B - Rectangular Runs Detail A Power Connector (#LLED8000-PC) Detail A 33" 1.5" 33" 1.5" Power Connector (#LLED8000-PC) 36" total length Detail B Detail B Continuous Connector (LLED8000-CC) 3" Continuous Connector (#LLED8000-CC) Option C - Runs with Custom Continuous Connector XX" Length Detail B Continuous Connector (#LLED8000-CC-XX) (XX - Specify Length) 12 lipleds Series Specification Grade LLED8000 800.921.CALI California Accent Lighting, Inc.

Tom Colicchio's Heritage Steak, Mirage Hotel Las Vegas, NV

APPLICATIONS Accent Lighting LLED8000-UC LLED8000-CM LLED8000-L Cove Lighting Wall Grazing Mirror Lighting Direct View Lighting LLED8000-LPL LLED8000-SR-30D LLED8000-STF LLED8000-LPL LLED8000-SR-15D LLED8000-L-F LLED8000 LLED8000-SR-45D LLED8000-SR-60D LLED8000-SR-F LLED8000-OL-F Recessed to wall Recess to Ceiling Pendant Mount LLED8000-RCR-F LLED8000-RCR-F LLED8000-SR-F 14 lipleds Series Specification Grade LLED8000 LLED8000-LPL Pendant Mount LLED8000-RC-F 800.921.CALI California Accent Lighting, Inc. Field Curveable Lighting

APPLICATIONS Accent Lighting Back Lighting LLED8000-UC LLED8000-UC LLED8000-UC Panel Lighting Side View Front View Cornice Lighting LLED8000-L Toe Kick Lighting LLED8000-ST-F Underbench Lighting LLED8000-LPL Step Lighting LLED8000-STL Undercounter Lighting LLED8000-CMC-F LLED8000-SR-F LLED8000-CMC-F Bartop Lighting LLED8000-STL Back Bartop Lighting LLED8000-SR-F California Accent Lighting, Inc. calilighting.com lipleds Series Specification Grade LLED8000 15

Irvine Spectrum, Irvine, CA. Designed by LPA, Inc. California Accent Lighting, Inc. 2034 E. Lincoln Ave. #431, Anaheim, CA 92806 ph. 800.921.CALI or 714.535-7900 fx. 714.535.7902 info@calilighting.com calilighting.com CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice. MADE IN USA 800.921.CALI California Accent Lighting, Inc.