TM LANDING CRAFT, UTILITY (LCU) BASIC CRAFT UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL MAINTENANCE INSTRUCTIONS

Similar documents
HEADQUARTERS, DEPARTMENT OF THE ARMY AND THE AIR FORCE 5 AUGUST 1988

TM NOVEMBER 1986 HEATER, SPACE, MULTIFUEL WITH BLOWER, 60,000 BTU/HR, 120 V UH-68G ( )

TECHNICAL MANUAL UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

OPERATING INSTRUCTIONS 2-1 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) 2-5 OPERATOR TROUBLESHOOTING 3-1

*TM Operator s, Unit, Direct Support, and General Support Maintenance Manual TECHNICAL MANUAL

AIR CONDITIONER, HORIZONTAL, 9,000 BTU/HR

AIR CONDITIONER, HORIZONTAL, COMPACT, BTUH

HEATER, DUCT TYPE, PORTABLE, TRAILER MOUNTED, 400,000 BTU/HR FlESTA MODEL FC OPERATOR S, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT

Operator's, Unit, Direct Support and General Support Maintenance Manual

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

TECHNICAL MANUAL OPERATOR S MANUAL FOR MULTIPLE INTEGRATED LASER ENGAGEMENT SYSTEM (MILES) SIMULATOR SYSTEM, FIRING, LASER: M78 NSN

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT MAINTENANCE MANUAL

TECHNICAL MANUAL OPERATOR, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) FOR

HEADQUARTERS, DEPARTMENT OF THE ARMY 25 FEBRUARY 1982

DEPARTMENT OF THE ARMY TECHNICAL MANUAL TECHNICAL MANUAL

TECHNICAL MANUAL OPERATOR S, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL IINCLUDING REPAIR PARTS AND SPECIAL TOOLS LISTI FOR

CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) MODEL B NSN

DEPARTMENT OF THE ARMY TECHNICAL MANUAL (FSN ) This copy is a reprint which includes current pages from Changes 1 through 3.

UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE REPAIR PARTS AND SPECIAL TOOLS LIST

DEPARTMENT OF THE ARMY TECHNICAL MANUAL TECHNICAL MANUAL OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

TM TO 34W

MODIFICATION WORK ORDER

TM REFRIGERATION UNIT, MECHANICAL, 9K BTU, ELECTRIC MODEL F9000RE ( ) MODEL F9000REA ( ) TECHNICAL MANUAL

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

LAUNDRY UNIT, TRAILER MOUNTED MODEL: M NSN EIC: (2LF) MODEL: M NSN EIC: (2LG)

DEPARTMENT OF THE ARMY TECHNICAL MANUAL

HEADQUARTERS, DEPARTMENT OF ARMY

TECHNICAL MANUAL OPERATOR S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL FOR

DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.

OPERATING INSTRUCTIONS 2-1 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) 2-5 OPERATOR TROUBLESHOOTING 3-1

AIR CONDITIONER, VERTICAL, COMPACT

CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) MODEL B NSN

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) FOR

TECHNICAL MANUAL UNIT MAINTENANCE MANUAL FOR CARRIER, PERSONNEL, FULL TRACKED, ARMORED, M113A2 NSN

TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

ARMY TM &P AIR FORCE TO 11H2-17-1

TECHNICAL MANUAL OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

TECHNICAL MANUAL OPERATOR S, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

TECHNICAL MANUAL. Approved for public release; Distribution is unlimited. INTRODUCTION 1-1 OPERATING INSTRUCTIONS 2-1

MSC Guidelines for Vital System Automation Procedure Number: E2-01 Revision Date: 11/10/2011

Operating Guide Safe Torque Off

TECHNICAL MANUAL OPERATOR'S MANUAL MONITOR, RADIO FREQUENCY R-2176/FRN (NSN )

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

ARM 10.2 MAINTENANCE OF CRITICAL SYSTEMS

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

Feature Summary. I. System

MIL-STD-1407B 17 December 1985 SUPERSEDING MIL-STD-1407A 16 July 1975 MILITARY STANDARD HEATERS, VEHICULAR COMPARTMENT; HEATERS, COOLANT, ENGINE;

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT MAINTENANCE MANUAL

LIQUEFIED GAS TANK BARGES WITH REMOTE CONTROL AND MONITORING OF ESSENTIAL SYSTEMS

Australian Standard. Fire protection for mobile and transportable equipment AS AS

Operating Guide Safe Torque Off

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Huckins CORINTHIAN KINGFISHER

PCD/PEM Power Conversion Department - Equipment Lockout Procedure

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

HEATER, DUCT TYPE, PORTABLE, TRAILER MOUNTED, 400,000 BTU/HR FlESTA MODEL FC OPERATOR S, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT

ELECTRIC FIRE PUMP CONTROLLER

TM DEPARTMENT OF THE ARMY TECHNICAL MANUAL OPERATOR S, ORGANIZATIONAL, DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE MANUAL

E-16 Main Engine Remote Control System

Operational Overview and Controls Guide

CONTENTS AUTOMATIC TRANSFER SWITCHES

Flopurge TS. Operation Manual

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

21-light Remote Annunciator. Owner s Manual

ABS RULES FOR BUILDING AND CLASSING OFFSHORE SUPPORT VESSELS FOR VESSELS CERTIFICATED FOR INTERNATIONAL VOYAGES

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

SHOP EQUIPMENT ELECTRONIC REPAIR SEMI-TRAILER MOUNTED (NSN )

Distributed Generation (greater than 10kW) Connecting to Vector s electricity network

OPERATOR S, UNIT AND DIRECT SUPPORT OPERATION AND MAINTENANCE MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOLS LIST) FOR CONTAINERIZED KITCHEN NSN

Spectron LSN (Life Safety Network) Suggested Specifications

B. Section Transfer Switches: Automatic transfer switch.

ALARM DEVICES FOR MAN OVER BOARD AND RESCUE ACTIONS (DAHMAS)

TrueAlert Addressable Notification

Engine Order Telegraph System (EOT) A067

TM &P TECHNICAL MANUAL OPERATOR AND FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST (RPSTL) FOR

Broom 370. Location Solent, United Kingdom. Dimensions

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

MILITARY TACTICAL HEATER 35,000 BTU SELF- POWERED, (MTH35SP)

TM &P HEADQUARTERS, DEPARTMENT OF THE ARMY TECHNICAL MANUAL

SPACE HEATER ARCTIC (NSN )

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

DELOMATIC 400, DM-400 HYDRO

Change Made by (Signature)

Architectural and Engineering Specification for a. Flash / Flare

MSC Guidelines for General Emergency Alarm & Public Address Systems

SEALED BID FORM M.V. CISCO

IPC CODE AND COMMENTARY

CONNECTION, ENERGISING, COMMISSIONING AND PERMANENT DISCONNECTION OF HIGH VOLTAGE APPARATUS

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Flostop TS D7E and A8E. Operation Manual

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

SECTION AUTOMATIC TRANSFER SWITCHES

FOR SERVICE TECHNICIAN S USE ONLY

MODEL MW200 MODEL MW600 AIR DRYER

Installation, Operation and Maintenance Manual for the Potable Water System Model: PWS-01 (380 VAC Suppy x 24 VDC Controls)

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

Transcription:

TECHNICAL MANUAL UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL SUPPORT MAINTENANCE INSTRUCTIONS LANDING CRAFT, UTILITY (LCU) NSN 1905-01-154-1191 BASIC CRAFT (PART I) This, copy is a reprint which includes current pages from changes 1-3. Approved for public release; distribution is unlimited HEADQUARTERS, DEPARTMENT OF THE ARMY 17JANUARY 1989

TECHNICAL MANUAL NO. 55-1905-223-24-18 HEADQUARTERS DEPARTMENT OF THE ARMY WASHINGTON D.C. 17 January 1989 UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL SUPPORT MAINTENANCE INSTRUCTIONS FOR THE LANDING CRAFT, UTILITY (LCU) BASIC CRAFT (PART 1) NSN: 1905-01-154-1191 REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS You can help improve this publication. If you find any mistakes or if you know of a way to improve the procedures, please let us know. Submit your DA Form 2028 (Recommended Changes to Publications and Blank Forms), through the Internet, on the Army Electronic Product Support (AEPS) website. The Intemet address is http://aeps.ria.army.mil. If you need a password, scroll down and click on "ACCESS REQUEST FORM". The DA Form 2028 is located in the ONLINE FORMS PROCESSING section of the AEPS. Fill out the form and click on SUBMIT. Using this form on the AEPS will enable us to respond quicker to your comments and better manage the DA Form 2028 program. You may also mail, fax or email your letter, or DA Form 2028 direct to: AMSTA-LC- CI/TECH PUBS, TACOM-RI, 1 Rock Island Arsenal, Rock Island, IL 61299-7630. The email address is TACOM- TECH-PUBS@ria.army.mil. The fax number is DSN 793-0726 or Commercial (309) 782-0726. Distribution Statement A: Approved for public release; Distribution is unlimited. TABLE OF CONTENTS PAGE PART I CHAPTER 1 INTRODUCTION... 1-1 Section I General Information... 1-1 Section II Equipment Data... 1-2 Section III Principles of Operation... 1-3 CHAPTER 2 UNIT MAINTENANCE INSTRUCTIONS... 2-1 Section I Repair Parts, Special Tools; Test, Measurement, and Diagnostic Equipment (TMDE); and Support Equipment... 2-1 Section II Service Upon Receipt... 2-1 Section III Unit Preventive Maintenance Checks and Services (PMCS)... 2-4 Section IV Unit Maintenance Troubleshooting... 2-96 Section V Unit Maintenance Procedures... 2-183 Section VI Preparation for Storage or Shipment... 2-1074 PART II CHAPTER 3 INTERMEDIATE DIRECT SUPPORT MAINTENANCE INSTRUCTIONS... 3-1 Section I Repair Parts, Special Tools; Test, Measurement and Diagnostic Equipment (TMDE); and Support Equipment... 3-1 Section II Service Upon Receipt... 3-1 Change 4 i

TABLE OF CONTENTS - cont PAGE Section III Intermediate Direct Support Preventive Maintenance Checks and Services (PMCS)... 3-2 Section IV Intermediate Direct Support Troubleshooting... 3-18 Section V Intermediate Direct Support Maintenance Procedures... 3-41 Section VI Preparation for Storage or Shipment... 3-750 CHAPTER 4 INTERMEDIATE GENERAL SUPPORT MAINTENANCE INSTRUCTIONS... 4-1 Section I Repair Parts, Special Tools; Test. Measurement, and Diagnostic Equipment (TMDE); and Support Equipment... 4-1 Section II Service Upon Receipt... 4-1 Section III Intermediate General Support Preventive Maintenance Checks and Services (PMCS)... 4-2 Section IV Intermediate General Support Troubleshooting Procedures... 4-2 Section V Intermediate General Support Maintenance Procedures... 4-4 Section VI Preparation for Storage or Shipment... 4-62 APPENDIX A REFERENCES... A-1 APPENDIX B MAINTENANCE ALLOCATION CHART... B-1 APPENDIX C EXPENDABLE/DURABLE SUPPLIES AND MATERIALS LIST... C-1 APPENDIX D TORQUE VALUES... D-1 GLOSSARY ABBREVIATIONS AND DEFINITIONS... Glossary 1 ALPHABETICAL INDEX... Index 1 POWER DISTRIBUTION... FP 1 ii

CHAPTER1 INTRODUCTION Page Section I. General Information...................... 1-1 Section II. Equipment Data........................ 1-2 Section III. Principles of Operation.................... 1-3 Section I. GENERAL INFORMATION 1-1. Scope. The scope of this manual is as follows: a. Type of Manual. Unit, intermediate direct support, and intermediate general support maintenance manual. b. Model Number and Equipment Name. Refer to the individual subsystems of this TM. c. Purpose of Equipment. Refer to the individual subsystems of this TM and Operator's Manual TM 55-1905-223-10. 1-2. Maintenance Forms, Records, and Reports. Department of the Army forms and procedures used for equipment maintenance are prescribed by DA Pam 738-750, the Army Maintenance Management System. 1-3. Destruction of Army Materiel. Refer to TM 750-244-3 for instructions covering the destruction of Army materiel to prevent enemy use. 1-4. Reporting Equipment Improvement Recommendations. If your equipment needs improvement, let us know. Send us an EIR. You, the user, are the only one who can tell us what you don't like about your equipment. Let us know why you don't the design. Put it on an SF 368 (Quality Deficiency Report). Mail it to Commander, U.S. Army Troop Support Command; ATTN: AMSTR-QX; 4300 Goodfellow Blvd.; St. Louis, Missouri 63120-1798. We'll send you a reply. 1-5. Preparation for Storage or Shipment. Administrative storage of equipment issued to and used by Army activities will have preventive maintenance performed in accordance with the Preventive Maintenance Checks and Services (PMCS) charts before storing. When removing the equipment from administrative storage, the PMCS should be performed to assure operational readiness. Preparation of equipment for shipment or short term storage is covered in paragraph 2-9. 1-6. Characteristics, Capabilities, and Features. A very broad view of the Basic Craft Manual (TM 55-1905-223-24-18-1/2) components is covered in the Operator's Manual (TM 55-1905-223-10). 1-7. Location and Description of Major Components. Refer to Section II. Description of Operator's Manual (TM 55-1905-223-10). Equipment 1-1

Section II. EQUIPMENT DATA 1-8. Equipment Data. Refer to the equipment data given in the Operator's Manual (TM 55-1905-223-10). 1-9. Safety, Care, and Handling. Safety precautions must be observed at all times while performing maintenance. General WARNINGS and first-aid data appear in the front of this manual. Review all safety information before starting any task. Carefully read through an entire maintenance procedure before performing any maintenance function. Make sure the task can be done safely. All WARNINGS, CAUTIONS, and NOTES are of great importance to your safety and the safety of the equipment. 1-2

Section III. PRINCIPLES OF OPERATION 1-10. General. The following paragraphs provide principles of operation of the LCU systems. 1-11. Power Generation System. The power generation system provides the LCU with primary (240 Vac, 3-phase, 60Hz, 250kW) and emergency (240 Vac, 3-phase, 60Hz, 40kW) electrical power (FIGURE 1-1). Primary power is generated by one of two ship's service diesel generator (SSDG) sets, which supply the main switchboard and the emergency switchboard through a bus tie from the main switchboard. Emergency power is generated by an emergency diesel generator set, which supplies the emergency switchboard for continued operation of vital systems and equipment during loss of primary power. In port, the LCU is capable of receiving shore power (480/240 Vac) through a shore power cable terminating at a two-connection shore power box. If available shore power is 480 Vac, the power is selected at the main switchboard through a circuit breaker and stepped down to 240 Vac by three shore power transformers, prior to main switchboard entry. Shore power of 240 Vac is selected at the main switchboard by circuit breaker, and bypasses the 480 Vac transformers. Automatic bus transfer equipment, located in the emergency switchboard, isolates the emergency switchboard from the main switchboard upon loss of primary power and allows emergency power to be supplied through the emergency switchboard. a. Ship Service Diesel Generator Engine. Two diesel generator set engines power individual ship service diesel generators, which provide primary electrical power throughout the LCU. The port ship service diesel generator engine (No. 2) is air started; the starboard ship service diesel generator engine (No. 1) is electrically started. Engine control and monitoring are provided from the engine room console and at the individual engine control panel. b. Shin's Service Generator. Two 250 kw brushless exciter generators provide 240 Vac, three-phase, 60 Hz primary ship's service power. Each generator is capable of providing 110 percent of the necessary at sea load for the propulsion and safety of the ship under normal conditions. The generators may be operated in parallel; however, normal operation has one generator on line and the other in reserve. C. Main Switchboard. The main switchboard (FIGURE 1-2), located in the engine room operating station, provides generator selection, shore power selection, and power distribution for ship's service 240 Vac and 120 Vac power. Distribution of 120 Vac is accomplished by ship's service 120 Vac transformers located in the engine room operating station. The emergency switchboard bus tie provides 240 Vac to the emergency switchboard. Power selection is provided by closing circuit breakers on the switchboard. Power monitoring is provided by ammeters, voltmeters, frequency meters, and synchronization meters. Controls are provided for manual and automatic generator voltage regulation and generator engine speed regulation, The switchboard bus tie also serves as an emergency 240 Vac power feedback source for the main switchboard from the emergency switchboard, to power selected equipment systems during emergency power conditions. An interlock system is incorporated into the switchboard to prevent shore power from being applied to the switchboard while generator power is applied. The interlock system also prevents the emergency switchboard emergency generator circuit breaker from being closed. d. Emergencv Switchboard. The emergency switchboard (FIGURE 1-3), located in the emergency generator room, normally receives 240 Vac primary power from the main 1-3

1-4

FIGURE 1-2. Main Switchboard. 1-5

FIGURE 1-3. Emergency Switchboard. 1-6

switchboard through the bus tie. Upon loss of ship's service power from the main switchboard, automatic bus transfer equipment within the emergency switchboard isolates the emergency switchboard and provides for automatic or manual starting of the emergency generator. Power monitoring of the emergency generator is provided by a voltmeter, ammeter, wattmeter, and frequency meter. A voltage adjustment control for the emergency generator output is also provided. A main switchboard bus tie circuit breaker and bus tie bypass switch permit distribution of emergency power (240 Vac) to the main switchboard. The emergency generator circuit breaker is prevented from being closed by an interlock system when primary power is being provided through the bus tie. Power distribution is accomplished through circuit breakers on the switchboard 240 Vac, 120 Vac, and 24 Vdc distribution panels. A step-down transformer provides 120 Vac back to the switchboard, and a 24 Vdc battery charger and switchboard batteries provide 24 Vdc back to the switchboard for distribution. e. Shore Power Box. The shore power box is located on the 01 level, aft exterior bulkhead. The two-connection shore power box provides a cable connection for shore power and another cable connection for providing shore power to another vessel in tandem. 1-12. Control and Monitoring System. The control and monitoring system provides for the centralization of control and monitoring functions for the main propulsion power train, selected pumps, ship's service diesel generators, and vital alarms. Pilothouse and engine room propulsion control is possible without intervention of engine room personnel. Primary control is from the pilothouse console with one soldier at the engine room console. The system permits constant automatic monitoring of vital machinery operating conditions and initiation of many functions from the engine room console. The control and monitoring system consists of the following: engine room console, pilothouse console, machinery plant monitoring and alarm system, engine order telegraph, steering control panel, dual station throttle control system, bowthruster and auxiliary fire pump control, fire detection, and bow ramp control. a. Engine Room Console (ERC). The ERC provides a centralized engine room location for: controlling propulsion shafts direction and speed; monitoring machinery alarm conditions; acknowledging engine orders; alerting engineering personnel of assistance needed and acknowledging the dead man alarm notification from the bridge. These functions are provided to the ERC via interfaces with the machinery plant monitoring system, engine order telegraph, and dual station throttle control system. b. Pilothouse Console (PHC). The PHC provides control and monitoring of the main propulsion power train speed and direction during usual ship operating and maneuvering conditions without intervention of engine room personnel. The PHC also provides for: machinery plant monitoring; autopilot operation; steering system selection and monitoring; bowthruster/auxiliary fire pump engine control; bowthruster control; communicating desired propulsion shaft direction and speed to the ERC; operation of blinker lights; operation of bow ramp; operation of ship's intercommunications system; and activation of ship's general alarm system. These functions are provided to the PHC via interface with the machinery plant monitoring system; autopilot; steering control panel, helm (wheel) and rudder angle indicator; dual station throttle control system, port and starboard main propulsion engine shaft tachometers; bowthruster engine shaft tachometer; bowthruster control panel; engine order telegraph; blinker light key; ship's intercommunications panel; and the general alarm contactor. 1-7