TREATMENT ROOM DATA SHEETS

Similar documents
TREATMENT ROOM DATA SHEETS

TREATMENT ROOM DATA SHEETS

TREATMENT ROOM DATA SHEETS

TREATMENT ROOM DATA SHEETS

Bath Planning Worksheet

Interior & Exterior Finishes & Specifications for The Bradford & Weston Style Homes

2017 Beaver Run Refurbishment Department Flip Packet for Homeowners

Scope of Work - Single Family, Oceanside, CA

2018 Beaver Run Refurbishment Department Flip Packet for Homeowners

Library stacks and records storage 150 LB/SF live load

UNIT TYPES: B (1 beds) C (2 beds) D (3 beds) E & F (Penthouse)

Scope of Work Single Family, San Diego, CA

Scope of Work - Single Family, San Diego, CA

SUNSET RIDGE. We measure our success. by the size of your smile! San Jacinto Division

Estimate Form for Kitchen Design and Installation

KINGS CROWN CONDOS.

room data sheet TAMURA HOUSE 396 POWELL STREET, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Modern Exteriors Stylish Kitchens Designer Bathrooms Comtemporary Living Fixtures & Finishes Schedule Inclusions Brochure

Single Family, National City, CA

LIVE WORK SHOP PLAY WESTGATE AT THE GLEN

PALM HAVEN. We measure our success. by the size of your smile! San Jacinto Division

SPACE TYPE: JUDICIAL CHAMBER

FENG SHUI SAVVY. Penthouse & Sub-penthouse suite finishes

Scope of Work -Single Family Home, San Diego, CA

Bathroom remodeling Dictionary

Multi Family, New Haven, CT

Scope of Work - Single Family, San Diego, CA

Platinum Features - Multi Section

Outdoor Kitchen Design By Carol Lamkins, CMKBD, CID

Scope Of Work: Single Family, La Mesa, CA

AMBER COVE. We measure our success. San Jacinto Division. By the size of your smile!

28', 32' AND 42' SERIES FLOOR PLANS

Proudly made in. Canada. to Canadian Standards. The Columbia Series. 14 Wide Single Section Homes

Scope of Work - Single Family, Escondido, CA

Luckdrops. Technical Spec Sheet. Studio+ Modular Home

Proudly made in. Canada. to Canadian Standards. The Columbia Series. 14 Wide Single Section Homes

Scope of Work - Single Family, San Diego, CA

Cabinet & Countertop Planning Guide

Astro Ranch Homes. Homes Worth Looking Into!

Tortolita Preserve - Home Site 8

PRESIDENTIAL SERIES 1

room data sheet GASTOWN HOTEL 110 WATER STREET, VANCOUVER, BC 1/11 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

About This Model. Series: Timberland Ranch Model: TL815A. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: Notes:

22576 INSPIRATION POINT INTERIOR FEATURES BY ROOM

Nims Village New Home Features

Scope of Work Condominium, Carlsbad, CA

room data sheet CORDOVA RESIDENCE 1/11 54 EAST CORDOVA STREET, VANCOUVER, BC RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Bradford 20 Wide Series

24'-0" RAILING W/H CUBBIES 6' PORCH OPT. BOOK CASE. BUNK BEDS 33x74 OPT. REFER 3608 WDWS. TWO. QUEEN BED 60x80 HITCH LOCATION SHELF RAILING

CABINETRY. KITCHEN Style Source West Wall Upper Cabinets. Flat Panel Framed Frosted Glass or Flat Panel. Flat Panel

Single Family, Hamden, CT

Pharmette Medicine Centers

CEILING DESIGN: WHAT is it? and what DOES IT DO?

Plot # R019A ± 74' ± 74' ± 65' Plot # R019A LEASE OUTLINE DRAWING GROSS LEASABLE AREA ± 4,631 S.F. DEMISING FRONT WIDTH DEPTH ± 13' ± 32' Lease Line

About This Model. Series: Blue Ridge MAX Model: B Grandview Max. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: 1638.

Astro Ranch Homes. Homes Worth Looking Into!

McLean Overlake New Home Features

USER MANUAL. Warming Drawer _ Earthlite, All Rights Reserved

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST

LUXURY HOME BED 3 BATH

Food Service Plan Review Information

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

room data sheet MARR HOTEL 401 POWELL STREET, VANCOUVER, BC 1/9 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Newberry. Foundation Framing

Elevations. Nova at the Vale

McLean Overlake New Home Features

Universal Design Checklist

MULTI-SECTION HIGHLAND ESTATES SERIES

Elevation of twelve-home building

BATHROOM AC-01 AC-02 AC-03 AC-04 AC-05

Closing Checklist. Mstr Hall/Clo. Mstr Bath. Guest Bath 1/2 Bath Kitchen Nook. Guest Hall. Utility Rm Garage Yard. Right Side Left Side Rear

SECTION 7 ~ PATHOLOGY GROSSING STATIONS

Walnut Park. residence E. Quality Features. 4 Bedroom, 2-1/2 Bath Approx. 1,934 SQ.FT.

You can choose one or all of the items from the Installation Service Menu.

Astro Ranch Homes. Homes Worth Looking Into!

Landscape Includes sprinkler system Irrigation, system maintenance, and landscape upkeep are all included in H.O.A. dues

Scope of Work - Single Family, Escondido, CA

BATH PLANNING GUIDE CONTRACTOR MY CONTACT INFORMATION PROJECT TYPE PLANNING YOUR VISIT BUDGET INITIAL CONSULTATION

YOUR KIND OF PLACE PRELIMINARY

27 Sanctuary Trail Missouri City, TX FEATURES

Scope of Work - Single Family, Carlsbad, CA

Seniors Home Program

CLINICAL SERVICES ADMINISTRATION (214)

Master Bath Gets a Complete Makeover

2011 Veterinary Stainless Steel Catalog

PRELIMINARY A NEIGHBORHOOD BY TRI POINTE HOMES

Different Budgets for Different Bathrooms

LARGE CAPACITY Even tall enough for two-liter bottles and large enough for serving trays, in both drawers.

11 HUMBERCREST BOULEVARD

Food Service Establishment Plan Review Form

8483D 3 BED- 2 BATH 944 SQ.FT.

Medikal Ürün Kataloğu Medical Products Catalogue. The Preference of Professionals

WORK DESCRIPTION HOUSING REHABILITATION PROGRAM HOUSING DEVELOPMENT DIVISION CITY OF COLORADO SPRINGS

Patriot Home Inspections

CENTRAL GREAT PLAINS SERIES

PATIENT CARE Single Wardrobe, Open Single Wardrobe, Door Double Wardrobe, Open. Double Wardrobe, Doors (shown) 5232 (reversed)

Scope of Work - Single Family, El Cajon, CA

SAMPLE PUNCH LIST. Room Trade Item Work needed Completed? KITCHEN

About This Model. Series: Pennwest 2-Story Modular Model: HA402A Pennwest Ultra 5. Style: 2-Story / Bedrooms: 3 / Bathrooms: 3 / Square Feet: 2579

MODEL WALL MOUNT AUTOPSY STATION DOUBLE SINK

Transcription:

MULTI PURPOSE ROOM Total Room Area: 12.3 m² / 132 ft² Basics Multi-purpose treatment rooms are set up to allow for the maximum variety of treatments - massage, simple body treatments or aesthetics. Each room is equipped with a mandatory brand signature table that is multipurpose, hydraulic, four-legged and padded. Three feet of space [914mm] must be allowed around the table to allow effective treatments that are ergonomically healthy for therapists. All rooms must have sinks and counters equipped with locked cupboards, wall mounted towel warmers (or warming drawers). Hot towel cabinets are be built in to the millwork. Each room is individually adjustable for lighting (all dimmable); temperature and music. Air-flow is away from the treatment table. All equipment (facial trolleys, steamers, hot stones) needs to have hidden storage cupboard to be out of sight of guests The following illustrations depict a standard layout for this treatment room including the following data: standard layout, typical equipment to brand specifications, typical locations for electrical outlets and control switches and minimum space requirements. For details on equipment, refer to Equipment Specifications Book or www.swissotelspastandards.com. Swissôtel Pürovel Spa Multi Purpose Rooms: Page 1 of 7

Swissôtel Pürovel Spa Multi Purpose Rooms: Page 2 of 7

EQUIPMENT SPECIFICATIONS - MULTI PURPOSE ROOM Equip. # Image Description Electrical Outlet Plumbing Item # Installed By c NFX-5 Pürovel Spa Signature Multi purpose Treatment Table Electrichydraulic lift with four-legs and signature padded top. Package includes all accessories. or 110V as 50 Hz, 10 Amps Quad outlet recessed under table SESWSTP- NFX-11 Hot Stone Trolley provides storage and convenient access to hot stone warmer and hot towel cabinet. or 110V as 15 Amps to unit LEDTF- NFX-16 NFX-30 This medium sized cabinet is designed to keep pre-moistened towels at a temperature of 158-176 F (70-80 C). 13 liter capacity holds approximately 18 face cloths. Technician Stool with height adjustable from 17"-23" with backrest, lumbar support, black base with 5 casters. Standard fabric color is Soft White. or 110V as 200 Watts, specify plug type to unit TJHC12UV- ST13358 NFX-20 Medical-grade oil warmer allows for countertop use or wall mount. Voltage as 7 Watts, 50/60Hz Euro-plug to Unit PL82-01-20-230V NFX-33 Hot Stone Heater designed for massage stone. Easy to lift off heating base for relocation of heater or to pour out water at the end of service. Voltage as 1425 Watts, 50HZ Euro Plug to unit EACSH -220 FX-20 Wall mount, high quality chrome complete with all hardware. Includes Wire kit.. Voltage as, 100 Rated Watts Hard wired, Built-in GFCI MYTEO130- 's Contractor Swissôtel Pürovel Spa Multi Purpose Rooms: Page 3 of 7

A. GENERAL Dimensions: Minimum 12 ft (3658) X 11 ft. (3353) or 132 sq. ft. or 12.3 sq. m. Allow at least 3 ft. [ 1 m] of space on all sides of the treatment table Sound Separation: Sound proofing between rooms, water pipes, drains and doors. Sound separation STC 54 minimum for all walls. Doors: Solid core Silent closing devices Window: Locate on wall opposite from entry door where possible Sound proof Window Treatment: Obscure/covered (black-out) Wall: Standard dry wall construction Where possible, all finishes should be rated Green ; made from environmentally friendly materials. Semi-gloss or satin finish preferred in dry areas Flooring: Wood or carpet is acceptable, but must be easily cleaned and textures or color ranges should hide any minor spills. Ceiling: Fully enclosed (no drop ceilings) Swissôtel Pürovel Spa Multi Purpose Rooms: Page 4 of 7

MILLWORK: (refer to Spa & Fitness Typical Millwork/Joinery Drawings shown below) Cabinets are lockable mastered (see room layouts) to store clean linen and supplies. Countertops are standard 35-36 [89-90 cm] high and have at least 5 linear feet [152 cm] of surface space. The surface is to be stain resistant, have a smooth surface and be easily cleaned. Hot towel cabinets should be placed on an open shelf in the upper cabinet. This space needs to be minimum of 2 6 wide (762), 1 3 high (381) and 1 2 deep (356) to fit the specified equipment. Must have electrical at shelf height. Custom trolley to match the millwork included All equipment (facial trolleys, steamers, hot stones) needs to have hidden storage cupboard to be out of sight of guests and equipment is able to be rolled into the cupboards. Swissôtel Pürovel Spa Multi Purpose Rooms: Page 5 of 7

B. EQUIPMENT (FIXED ONLY) Hand sink at counter is flush to countertop, with either lever handles or one handle temperature controls. Faucet is goose neck style at least 8 [20.32cm] height above sink top and should not splash or make noise when water is on. E.g. Stillness deck mount faucet K-956 from Kohler Towel warmer is hard wired hot towel warmer is required positioned on wall near door side or as positioned in drawings. Option to provide heated drawers in millwork for towels. C. MECHANICAL ELECTRICAL PLUMPING (MEP) HVAC: Each room must have independently controlled HVAC unit with full temperature range. Supply grills and airflow are directed away from the tables. Slot vents are preferred and all intakes are hidden. Access panels are discretely placed - above the door or out the line of sight when guests enter. All heating and air conditioning vents must be silent and placed to avoid blowing on clients. Humidity Level: Low PLUMBING Drain: Sink waste Fire Suppression: Per Code ELECTRICAL Power Electrical Outlets: Two 110v/220v 15 amps GFCI outlet at counter One 110v/220v 15 amps, GFCI, outlet recessed in floor under the center of the treatment table. If monument outlet is required, must be no higher than 2 (50.8mm.) Two wall locations of 110v/220v 15 amps 12 AFF on wall opposite wall of counter and side wall away from door Swissôtel Pürovel Spa Multi Purpose Rooms: Page 6 of 7

110v/220v 15 amps GFCI outlet located behind the Hot Cabinet (either to far right or left side to allow or plug). See locations on sample layout. Lighting: All lights are dimmable and indirect. Two wall sconces minimum are provided One attractive ceiling mounted light over the table or cove lighting around the room One task light under cabinet over countertop. Place control for this light at countertop location. All controls are to be low tech and simple to operate adjacent to other controls at the door entry. Music: Control for selection of music of minimum of 8 channels from a central system with a volume control Speakers are of high quality, recessed in the ceiling. For sound system requirements refer to Section P of Design Standards Telephone: Not required D. OTHER Fixtures: Robe hook (number to match number of tables) located behind arrival door Signage: Small number beside each door outside room (names are optional to add) Small dowel/hook under the number for hanging in use/not in use symbol Local Code: Take into consideration all spa licensing requirements as well as zoning, building codes and permits, labor unions, fire safety codes, water, sewage, electrical code and ADA requirements as they relate to your area. Check all Local Department of Health, State Board and health and safety regulations. Swissôtel Pürovel Spa Multi Purpose Rooms: Page 7 of 7