VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

Similar documents
FCC Fan-Coil Units High-Performance, Vertical

RT-OA TM Rooftop Outdoor-Air (DOAS)

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

THE ULTIMATE ROOFTOP SOLUTION

catalog CDV Fan-Coil Units High-Performance, Vertical

CE311 Fall 2016 Mid-Term Exam 1

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Chilled Water DOAS Fan Powered Terminal Units

Fundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

Standards and Guidelines. Presented by: Aric Murray December 12, 2014

Humidity Control Design Tips. R. Mark Nunnelly, PE, CxA, LEED AP President

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

DIVISION 15 MECHANICAL

TDSHS Air Change Requirements and the Basics of Psychrometrics. Presented by: Aric Murray December 06, 2013

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Humidity Control & Psychrometrics

Field Test of Combined Desiccant-Evaporator Cycle Providing Lower Dew Points and Enhanced Dehumidification

Energy Recovery with Cooling and Heating

Air Conditioning Clinic

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Psychrometrics: The Science of Moisture in Air. Presented by Tom Peterson, CEO and Founder. Climate by Design International

RAV Engineering Guide

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

A/C Cooling Load calculation and measurement

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

Temperature. In the HVAC area, we talk about two kinds of temperatures.

Dehumidification for Industrial Coating Applications. By: Jay Kranker Munters MCS

PhEn-602 Pharmaceutical Facility Design. Notes #7 J. Manfredi

Modular Active. Chilled. Beams

Dehumidification: Energy Efficiency Comparisons

Pharmaceutical Facility Design

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Managing HVAC in High Performance Buildings

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

IAQ Building Education and Assessment Model (I-BEAM)

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

APPLICATION GUIDE BEAMS

BOOK 2 SPECIFICATIONS

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

PACKAGE AIR CONDITIONER

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

4. OVERVIEW OF MECHANICAL SYSTEM

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Submittal Data Performance Data Electrical Data

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

RoofPak Applied Rooftop Systems

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Urbana Free Library HVAC Analysis. Prepared for the Urbana Free Library. Prepared by Paul Boland, P.E., and Nathan Alderman, E.I.T.

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

VariCool VAV Engineering Guide

FAARM-Underground Facility. Conceptual Design Review. Mechanical Systems. Dunham Associates, Inc.

FAN POWERED VAV TERMINALS

Optimisation of cooling coil performance during operation stage for improved humidity control

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Displacement Ventilation

Appendices. Included in this section are

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Designing Energy Efficient Outdoor Air Systems

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

1.1 This section applies to air handling units for HVAC Systems.

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

NON-REVERSING, 100% OUTSIDE AIR HEAT PUMP FOR HEATING AND COOLING

SKYPAK II, 3 Ton Series, gives you a

Dehumidifying with Dedicated Outdoor Air

TYPICAL CPA SPECIFICATIONS

Multi-Path RTU-TYPE 2

The Basics - B Practical Psychrometrics. Jerry Cohen President Jacco & Assoc.

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

HVAC Optimization with Cold Air Distribution

Mammoth Water Source Heat Pumps

Trane CDQ Desiccant Dehumidification

100% Outdoor Air Dehumidification Methods

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Residential HVAC System Design

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

Advance Release September 2009

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Transcription:

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Unit with Enhanced Humidity Control Motorized Bypass Damper Temperature and Humidity Controller Reheat Control Elastomeric Foam Insulation High Efficiency, Deep Loading, Synthetic Media Filtration Easily Removable s

The ENVIRO-TEC hi-rise fan coil unit with enhanced humidity control changes the way the industry builds hi-rise hotels and residences in humid climates! ENVIRO-TEC leads the fan coil industry again, with the introduction of the ENVIRO-STAC VH hi-rise fan coil with enhanced humidity control. The unique options of the VH with enhanced humidity control help prevent mold growth in hotel and residential spaces in humid climates when used as a part of a program to control mold. The ENVIRO-STAC unit mitigates conditions that contribute to mold and mildew growth when applied in a building with an adequate vapor barrier, preconditioned outside air and positive building pressurization. Mold spores grow only in the presence of moisture and organic food materials. Mold growth is mitigated by reducing the spore count, moisture and organic dust that sustains their growth. In humid climates, the greatest challenge is reducing relative humidity at part load. The major causes of mold growth in high rise hotel and residential buildings are inadequate building envelope vapor barriers, lack of pretreatment of outside air, negative building pressurization and oversizing of room air conditioning units. And traditional fan coils are oversized at part load conditions! The ENVIRO-STAC unit with enhanced humidity control includes the following innovations: Motorized coil bypass damper in conjunction with fan speed control increases dehumidification at part load and more closely matches cooling capacity to the room load during off peak operation. Temperature and humidity controller improves part load relative humidity control. Reheat control for dehumidification in extreme climates. Elastomeric foam insulation inhibits moisture absorption and organic dust adhesion. The insulation itself will not sustain mold growth. Deep loading, synthetic media filtration protects both the coil and the coil bypass air from airborne contaminants. Filter media will not support mold growth. s and piping packages are removable in minutes for periodic cleaning outside of the unit through the standard front panel with a nut driver and a pair of wrenches. Stainless steel drain pans and coil casings are available and recommended for hotels or residences on the salty sea coast. REMOVABLE ENVIRO-STAC fan coil units with enhanced humidity control are available with electric or hot water heating. Risers are not shown. Reducing space relative humidity reduces risk of mold growth while enhancing comfort The ENVIRO-STAC unit enhances part load dehumidification by combining fan speed control and cooling coil air bypass at part load conditions as the space temperature approaches room set point. Reducing coil air flow at a constant chilled water GPM depresses the dry bulb and wet bulb temperatures and the humidity ratio of the air leaving the coil. The result is lower room relative humidity than is achievable with standard fan coil controls and unit configurations. bypass and fan speed control reduce space relative humidity The ENVIRO-STAC size 04 unit of Figure 1 features a four row cooling coil, a motorized bypass damper, three-speed fan, and a DDC temperature and humidity controller.

The unit operates at Maximum CFM and GPM when the space temperature is well above set point. As the room temperature approaches set FIGURE 1 Two Way Valve Control, Speed Control and Bypass on Low Speed VHC Size 04. EWT= F. 4 row coil. 10 ENTHALPY - BTU PER POUND OF DRY AIR 30 Entering Air Air Flow Water RH Humidity Dew Leaving Air Sensible Ratio Point Dry Wet Flow Dry Wet 1bs Water / % SHR % F SMBH TMBH Bulb F Bulb F CFM GPM Bulb F Bulb F 1000 lbs Air Turndown Room Design Condition 62.5 -- -- -- -- 49.9 9..1 -- -- -- High Speed, Bypass Closed, 62.5 4 2.79 52.5 51.3 92.4 7.71.4 10.7 14 100 0.76 Low Speed, Bypass Closed, ENTHALPY Dh 62.5 2 2.79 49.3 48.6 95.3 7.11 48 7.5 HUMIDITY RATIO DW 10.4 % 0.72 Low Speed, 30 % Bypass, 62.5 189 2.79 47.5 47 96.5 6.72 46.6 5.6 8 52% 0. Mixed Air Temperature, Supply Air Temperature -- -- -- --.8 52.2 79.1 7.48 49.4 -- -- -- -- SATURATION TEMPERATURE - F Two Way Control Valve, Speed Control and Bypass on Low Speed High Speed, Air Leaving Low Speed, Air Leaving ASHRAE PSYCHROMETRIC CHART Mixed NO.1 Air, Supply Air Temperature 30% Air Bypass NORMAL at Low TEMPERATURE Speed, Air Leaving BAROMETRIC PRESSURE: 29.921 INCHES OF MERCURY R R Copyright 1992 AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS, INC. 12.5 : 12.5 ENTHALPY HUMIDITY RATIO 13 Dh DW % % % % % % 30% % 10% RELATIVE HUMIDITY 13.5 Room Design Condition FIGURE 2 Modulating Fan Speed, Constant GPM. EWT= F. 4 row coil. 10 ENTHALPY - BTU PER POUND OF DRY AIR SEA LEVEL SENSIBLE HEAT TOTAL HEAT 30 SATURATION TEMPERATURE - F 100% of Max CFM, Max GPM % of Max CFM, Max GPM % of Max CFM, Max GPM % of Max CFM, Max GPM Entering Air 13 Qs Qt : % % % Modulating Fan Speed, Constant GPM % % % 30% % 13.5 10% RELATIVE HUMIDITY Air Flow Water RH Humidity Dew Leaving Air Ratio Point Flow Dry Wet 1bs Water / % CFM GPM Bulb F Bulb F 1000 lbs Air : Room Design Condition Sensible Dry Wet % F SMBH TMBH Bulb F Bulb F Turndown Room Condition 62.5 -- -- -- -- 49.9 9..1 -- -- -- -- 100% of Max CFM, Max GPM 62.5 4 2.79 52.5 51.3 92.4 7.71.4 10.7 14 100 0.76 % of Max CFM, Max GPM 62.5 330 2.79.6 79.7 94.1 7.74 49 8.7 11.9 81% 0.73 % of Max CFM, Max GPM 62.5 2 2.79 48.2 47.6 95.9 7.78 47.1 6.4 9 % 0.71 % of Max CFM, Max GPM 62.5 4 2.79 46.7 46.4 97.9 7.81 46.1 4.7 6.7 54% 0. Compared to Figure 1, this arrangement results in less desirable humidity conditions. SHR point, the fan speed is reduced and, just above the set point, the bypass damper is opened. The state conditions and psychrometric chart in Figure 1 show that the humidity ratio (W) of the air leaving the coil operating at low speed with 30% bypass is reduced by 13% over that of the air leaving the coil on high speed. The mixed air temperature of.8 F DB is above the room dew point of.1 F, which will prevent sweating of the supply grille. 14 VOLUME - CU.FT. PER LB. DRY AIR 95 Air motion is very important to perceived comfort. The bypass damper provides excellent part load dehumidification and maintains a higher air flow and better air motion than can be achieved by fan modulation alone. The fan horsepower is reduced by % from high speed to low speed, saving power and reducing the fan and air noise from maximum cooling operation. 14 VOLUME - CU.FT. PER LB. DRY AIR Fan speed modulation alone may cause grille sweating and cold supply air complaints ENVIRO-TEC has applied variable speed fan motor technologies to fan coils, air handlers and VAV terminals, but this technology alone was not selected for the ENVIRO- STAC unit with enhanced humidity control. This is because the deterioration of room air motion and the depressed supply air temperatures 95 100 14.5 100 WET BULB TEMPERATURE - F Modulating control damper opens as space humidity rises to increase latent cooling and to mix leaving and return air, raising the supply air temperature. 14.5 105 105 DRY BULB TEMPERATURE - F 110 1 ENTHALPY - BTU PER POUND O DRY BULB TEMPERATURE - F 110 1 HUMIDITY RATIO - POUNDS MOISTURE PER POUND DRY AIR ENTHALPY - BTU PER POUND OF DRY

12.5 10 Entering Air Air Flow Water RH Humidity Dew Leaving Air Sensible Ratio Point Dry Wet Flow Dry Wet 1bs Water / % SHR % F SMBH TMBH Bulb F Bulb F CFM GPM Bulb F Bulb F 1000 lbs Air Turndown Room Condition 62.5 -- -- -- -- 49.9 9..1 -- -- -- -- 100% of GPM, Max CFM, 62.5 4 2.79 52.5 51.3 92.4 7.71.4 10.7 14 100 0.76 % of GPM, Max CFM, 62.5 4 29 53.7 52.5 92.6 8.14 54.6 10.1 12.6 100 0. % of GPM, Max CFM, 62.5 4 1.39.4 54.1 92.2 8.63 53.2 9.3 10.7 92% 0.87 % of GPM, Max CFM, 62.5 4 0.7 59.3 56.8 86.2 9.29.2 7.5 7.5 74% 10 caused supply grille sweating at low airflows. The psychrometric chart in Figure 2 and accompanying state points show the problems created by fan modulation alone. With a room dew point at design of.1 F, the supply air temperature at % of design air flow (48.2 F) presents supply grille condensate and cold supply air draft difficulties. Others in the industry are promoting modulating chilled water control valves on fan coils to reduce part load GPM and create pumping cost savings. This is a suitable strategy for dry climates where room sensible heat ratios are 0. or greater at all conditions. In humid climates, modulating chilled water valve control should be avoided. The Figure 3 psychrometric chart and state points demonstrate the 30 FIGURE 3 Modulating Control Valve, Fan at Constant High Speed. EWT = F. 4 row coil. ENTHALPY - BTU PER POUND OF DR SATURATION TEMPERATURE - F Modulating Control Valve, Fan at Constant High Speed % % of GPM, Max CFM % of GPM, Max CFM % of GPM, Max CFM 100% of GPM, Max CFM 13 % % % % % 30% % 10% RELATIVE HUMIDITY problem that results from modulating valve control and giving the room occupant the ability to select high fan speed. Dehumidification is always worse at part load than at full load. Once the water flow is % of design or lower, dehumidification is not performed at all. Reheat may be necessary in extremely humid environments The ENVIRO-STAC has the capability for reheat for those situations where low room sensible heat ratios will be experienced for extended periods. If a room SHR of less than 0. is expected, reheat should be considered. If hot water reheat is to be used, hot water supply temperature reset from outside air temperature should be considered to avoid excessive leaving air temperatures. Electric Room Design Condition Compared to Figure 1, this arrangement results in less desirable humidity conditions. 13.5 heaters should be carefully sized to avoid excessive leaving air temperatures. 14 VOLUME - CU.FT. PER LB. DRY AIR Closed cell foam insulation will not harbor moisture, dust or mold The elastomeric closed cell foam insulation used in the ENVIRO- STAC unit has a smooth, sealed surface. Moisture and organic material will not readily adhere to and cannot penetrate the surface of the insulation. The insulation itself will not sustain mold growth. If the insulation surface becomes dusty over time, it can be easily cleaned without damaging the insulation. The elastomeric foam meets NFPA A flame, smoke spread and melting point limits. Some less expensive polyethylene foam products do not meet the melting point limit and should be avoided. Mitigate mold spore population and organic dust food sources The deep loading, two stage filter media with edge sealing is % efficient at 1.5 microns (MERV 6), removing many mold spores that are typically 1 to 100 microns in size. The filter also removes much of the organic dust from the air stream that might serve as a food source for the growing mold. Easy cleaning and maintenance Periodic coil cleaning is necessary over the building life. The cooling coil and piping package can be removed in just a few minutes using a pair of wrenches and a nut driver. Another ENVIRO-TEC innovation for the vertical hi-rise fan coil stainless steel braided hoses with swivel connections on both ends permit the isolation of the unit from the risers, removal of the hoses and draining of the 95 100 105 110 DRY BULB TEMPERATURE - F ENTHALPY - BTU P

connections to the coil over the unit drain pan. After removing the pop top valve actuators, the coil and piping package assembly lifts out through the return air grille and access panel. A spare coil and piping package assembly can be installed and put back in operation in 10 to minutes, keeping the room in use, while the dirty coil is cleaned and inspected at a remote location before being returned to service in another unit. Riser slot knock outs on rear and sides of unit allow field reconfiguration. configured in the field with a pair of snips to open grille duct collars and riser access after the unit arrives on the job. Supply air openings are lined with closed cell foam insulation ENVIRO-TEC offers flexible, stainless steel reinforced Kevlar hose kits as a standard feature. Stainless steel braided hoses and knockouts increase unit flexibility and reduce costs of installation and field changes ENVIRO-TEC has the leading technology in the fan coil industry with the application of stainless steel hose kits on stack fan coils and with riser kits that are built, pressure tested with their shut off valves, and insulated. Riser kits are boxed by unit, tagged with floor, riser and room numbers and shipped well in advance of the fan coil units. This enables the builder to install risers quickly and early in the construction cycle as the floors are poured. Completed risers can be pressure tested and flushed before the units ever arrive on the site. This permits delaying the setting of the fan coil units until after the building is enclosed and able to protect the fan coils from rain and construction dust keeping the units clean, dry and less likely to support biological growth. In addition, this process can help meet LEED credit EQ credit 3.1: Construction IAQ Management Plan During Construction. Another innovation in stack fan coils from ENVIRO- TEC are standard knock outs for supply grilles all four sides and the top of the units and in the back and both sides for riser connections. The units can be If field changes are necessary to a factory configured unit, they can easily be made. Expensive change orders and costly delays are eliminated. Not opening the supply grille until the unit is installed keeps the unit supply plenum clean and dry during shipping and staging at the jobsite, helping to prevent mold development. Insulated drain pan with factory installed pre-formed p-trap. Removable drain pan The optional removable drain pan is an exclusive ENVIRO-TEC innovation. The drain pan can be removed, cleaned, and quickly replaced. Contact your ENVIRO-TEC representative for assistance with our browser based selection program, Web-Select. The program corrects for elevation and prints fan curves, coil selections, and electrical data.

ENVIRO-STAC Fan With Enhanced Humidity Control SUGGESTED GUIDE SPECIFICATION MOTORIZED COIL BYPASS DAMPER Provide a motorized two-position coil bypass damper. Damper shall be sized such that when it is opened, 30% of the fan airflow capacity will be drawn through the damper opening, bypassing the cooling coil. INSULATION Provide elastomeric foam insulation. Insulation density shall be a minimum of 3 pounds per cubic foot. Insulation shall meet all requirements of NFPA -A flame and smoke spread, and melting point. Polyethylene insulation is not acceptable. FILTERS Provide 1 inch self-gasketing filter consisting entirely of synthetic media and frames. Filter shall be tight fitting to prevent air bypass. Filter shall be easily removable from the return air opening with the front panel removed. Filter efficiency shall be % at 1.5 microns (MERV 6). UNIT HANDLING AT JOB SITE Provide factory fabricated risers with isolation valves, factory pressure tested under water, shipped separate from the fan coil unit. Risers shall be installed, pressure tested, filled and flushed, and floor slab shall be fire safed prior to the fan coil units being delivered to the job site. Fan coil units should be installed as late as possible in the construction phase to help protect the units from construction dust. NON-MODULATING CONTROL VALVES Provide a standard factory assembled valve piping package to consist of a 2 or 3 way, on/off, motorized electric control valve and two ball isolation valves. DRAIN PAN Provide an insulated drain pan with factory installed pre-formed p-trap. Option: Provide a removable drain pain to allow for proper cleaning. Option: Drain pan should be constructed of stainless steel or a non-ferrous material. STAINLESS STEEL COIL CASING Option: Provide stainless steel coil tube sheets. UNIT KNOCK OUTS Provide fan coil units with standard knock outs for supply grills on all four sides and the top of the units, along with knock outs for riser connections in the back and both sides of the unit to allow for field configuration and to help in keeping the units clean. Visit www.enviro-tec.com for catalog, guide specifications, submittal drawings, and Web-Select online selection program. ENVIRO-TEC is a registered trademark of Johnson Controls, Inc. in the United States of America and other countries. Other trademarks used herein may be trademarks or registered trademarks of other companies. Catalog: PUBL-58 (7) Supersedes PUBL-58 (1108) Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 531 Printed in USA www.enviro-tec.com