Model Series Series

Similar documents
Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

Models Series Series

Models Series Series

PumpAgents.com - Click here for Pricing/Ordering PAR MAX3 Models Series 3.4GPM/12.8LPM

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

SHURFLO BLASTER II MARINE WASHDOWN PUMP PRODUCT TECHNICAL DATA SHEET

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

Automatic Water System Pump SERIES

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

Welcome! Today s topic: Small Home Repairs. November 14, 2015

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

Model: Series. PumpAgents.com - buy pumps and parts online. DESIGNER STYLED MARINE TOILET With Integral Bowl Rinse Water/Waste Evacuation Pump

LC Series - Light Commercial Pump Station Installation and Operation Manual

OWNERS GUIDE TO INSTALLATION AND OPERATION

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET CONVERSION FEATURES. Model Series INSTALLATION

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

How to Fix a Leaky Toilet:

Model Series QUIET - FLUSH ELECTRIC TOILET CONVERSION FEATURES. Model Series INSTALLATION SPECIFICATIONS VARIATIONS AVAILABLE OPERATION

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

IMAGE V. Parts and Service Manual

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

Model Series. Model Series QUIET - FLUSH ELECTRIC TOILET CONVERSION FEATURES SPECIFICATIONS OPERATION

Operation & Maintenance Manual for

Model 53 Macerator Pump Installation, Operation, Repair Manual

HEATING AND VENTILATION

APW PSI PRESSURE WASHER

CHAMPION PUMP OWNER S MANUAL

INSTRUCTION AND REPAIR MANUAL

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

WS1 Greensand Installation & Start Up Guide

BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA

SMF PUMP OWNER S MANUAL

Elite Primer Baldor Series External Pond Pump

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Model Series. PumpAgents.com - buy pumps and parts online. DESIGNER STYLED MARINE TOILET With Quiet-Flush System. Model: Series FEATURES

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

FLANGE-MOUNT CENTRIFUGAL PUMPS

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

ENCLOSED UNIT TECHNICAL MANUAL Items # &

Model LF-310 Air Operated

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

Installation Instructions

PULSE JET DE-ICER OPERATING MANUAL SETUP OPERATION MODEL PJDX-C (REV B) Mode Adjustment Knob WATER SERVICE LINE THAWER FLOW MODE PULSE MODE

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

TABLE 1 Electrical Specifications

04 Toilet Systems INTRODUCTION

Installation Manual CARBONATOR With Plain-Water Booster

Patriot. Automatic Pool Vacuum Cleaner. Patent No. 5,794,293. Owner's Guide. Model *Recommended for 3/4 HP and above

Item # Modular Blast CaBinEt instructions

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

KD-27A SERIES DISHWASHERS

BEFORE OPERATING THE MACHINE: WARNING

TABLE 1 Electrical Specifications. Phase

Niles Steel Tank Hot Water Generator Installation and Operation Manual

Installation Instructions for. OmniFount

Installation Instructions

Operation and Maintenance Manual 120V/60HZ

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

FOR PRODUCT/WARRANTY REGISTRATION Go to Click on SUPPORT at the top of homepage Click on PRODUCT REGISTRATION

Lite Flush Electric Toilets

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

CIRRUS AIRPLANE MAINTENANCE MANUAL

* * * * * Deluxe Flush Electric Toilets. NEW! Touch Pad Controller. Deluxe Flush Series FEATURES RINSE OPTIONS MODEL RANGE

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Removing shipping locks

Installation Instructions EFS Hand Washing Station

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

Instruction Manual for Electric Marine Toilets LT-0E and LT-1E

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

Operation & Maintenance Manual for

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Please read the following installation instructions first after purchasing this product or transporting it to another location.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

TUB AND SHOWER FAUCET

42 X 24 FT 48 X 24 FT

INSTALLATION INSTRUCTIONS

Eccotemp L5 and L10 Comprehensive Troubleshooting Guide

User Manual Box Exhaust Fan Series (Belt Drive)

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

INSTANT-FLOW C-MICRO WATER HEATER

Installation & Service Guide

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

2000 PSI Electric Pressure Washer

568X, 587X, 588X Series

Transcription:

PumpAgents.com - Click here for Pricing/Ordering Model 36800-Series 36900-Series ELECTRIC WATER SYSTEM PUMPS Automatic Multi-Outlet FEATURES Self-Priming Diaphragm Design Allows Dry Running Built-in Discharge Check Valve Quiet Operation Built-in Hydraulic Pulsation Dampener Large Vibration Absorbing Pads Ports Available with Barb or Threads Meets USCG Electrical Standards SPECIFICATIONS Open Flow: U.S. GPM Litres/min Imp. GPM 36800-Series: 3.3 12.5 2.75 36900-Series: 4.2 15.9 3.5 Cut-in Pressure (Nominal): 20 psi (1.4 bar) Cut-off Pressure (Nominal): 40 psi (2.7 bar) Vert. Dry Suction Life: 5 Feet (1.52 m) Ports: Slip on 1/2" to 5/8" ID hose Approx. Ship. Weight 36800-Series: 11 lb (5.0 kg) 36900-Series: 12 lb (5.4 kg) APPLICATIONS Jabsco automatic water system pumps are designed for self contained recreational vehicles and pleasure boats with multiple outlet water systems. The systems are automatic when a faucet is opened, the pump instantly begins operation to provide a constant flow from tank to faucet. Closing the faucet automatically discontinues pump operation. Model 36800 is suited for up to five outlet distribution systems. Model 36900 is recommended for large distribution systems where duty requires simultaneous operation for multiple faucets. DIMENSIONAL DRAWING 36800- Series 36900- Series 8-3/8" (213 mm) 10-1/8" (257 mm) 6-1/2" (165 mm) 6-1/2" (165 mm) 9-7/8" (251 mm) 9-7/8" (251 mm) STANDARD MODELS 36800-Series Automatic Water System Nom. Presssure AMP Cut-in Cut-out Fuse/Breaker * Model Voltage Draw psi (bar) psi (bar) 36800-1000 12 Vdc 6.0 20 (1.4) 40 (2.7) 8 amp 36800-0200 12 Vdc 6.0 10 (0.7) 20 (1.4) 8 amp 36800-1010 24 Vdc 3.0 20 (1.4) 40 (2.7) 4 amp 36800-0210 24 Vdc 3.0 10 (0.7) 20 (1.4) 4 amp 36900-Series Automatic Water System Nom. Presssure AMP Cut-in Cut-out Fuse/Breaker * Model Voltage Draw psi (bar) psi (bar) 36900-1000 12 Vdc 7.5 20 (1.4) 40 (2.7) 15 amp 36900-0200 12 Vdc 7.5 10 (0.7) 20 (1.4) 15 amp 36900-1010 24 Vdc 3.8 20 (1.4) 40 (2.7) 5 amp 36900-0210 24 Vdc 3.8 10 (0.7) 20 (1.4) 5 amp * Customer supplied, not included with pump. INSTALLATION MOUNTING Jabsco diaphragm pumps are self-priming. They may be located above or below the fresh water tank. The pump is equipped with vibration pads which are most effective when the pump is mounted upright on a solid surface. Selection of a cool, dry ventilated location will generally extend pump life. PLUMBING To minimize water pressure drop, the size of water supply line should not be less than sizes shown in table below. Valves, elbows, etc. used should be the same size as pipe or tubing. Use gate valves only. Fresh water tank must be vented. MINIMUM PIPING SIZE Supply Line Length Tubing ID Pipe Size Less than 48" 1/2" 3/8" 48" or more 5/8" 1/2" Model 36800-Series, 36900-Series

PLUMBING WIRING PRESSURE REGULATOR It is recommended that systems having a connection for a city water entry be equipped with a pressure regulating check valve set at approximately 35 psi. This valve automatically regulates the incoming water pressure to avoid damage to pump and plumbing from excessive pressures. Models 44410-Series (Permanent Flush Mount) and 44410-1010 (in-line Hose Type) pressure regulating valves are recommended for this purpose. CHECK VALVES A built-in port check valve protects the pump from the unregulated high pressure sometimes encountered in city water hookups. However, an additional check valve may be installed at the cold water inlet of the water heater to minimize heat transfer to the cold water line and protect the system in case of water heater relief valve failure. Jabsco offers qualified in-line check valves, Models 34344-0000, 35027-0000 and 35195-0000. SUCTION STRAINER A Pumpgard No. 36400-0000 (strainer/filter) is recommended, installed between the pump and fresh water tank. It helps prevent valve clogging caused by foreign material entering the pump. WATER PURIFIER Many water purifiers cause excessive restriction to flow, especially when element is in use for some time. When used at the main distribution line, it causes the pump to cycle on and off rapidly. To minimize cycling, use an accumulator tank between pump and purifier, or install purifier to feed a single outlet for drinking-water only. ACCUMULATOR TANK The use of an accumulator tank (Jabsco Model 30573-0000, 12573-2000 or 18810-0000), although not required, is recommended for a more effective water distribution system. It eliminates "water hammer," stores pressures to allow a limited use of water without restarting pump (desirable at night-time), assures a constant, even stream of water at faucets farthest from pump and prolongs pump life by cutting down rapid start/stop operation. WIRING Pump should be wired in a circuit independent of all other accessories according to the wiring diagram. WIRE SIZE CHART (A.W.G. - COPPER) Voltage Up to 80' 80' to 100' 100' to 150' 12 Volts Two Wire 14 12 10 24 Volts Two Wire 16 14 14 MOTOR PROTECTION The pump wiring must include a fuse/ breaker in the positive lead to protect against overcurrent draw. See specification table for proper fuse rating. SWITCHES An on-off switch should be installed in the circuit to turn off pump when vehicle or boat is unattended, stored, or in transit, or hooked up to city water. Use Red and White Label included as a reminder to shut down water pressure system and open faucet to relieve pressure when unattended. AC-DC POWER CONVERTERS AC-DC converter/ charger packs should be wired to operate pump directly from the battery at all times. If the battery is bypassed and converter is used to service the pump directly, be sure the total electric loads do not exceed the converter amp rating. Overloading the converter could result in low-voltage condition at the pump. VOLTAGE CHECK After installation, check the voltage at the pump motor. Voltage should be checked when pump is operating along with all the inside electrical fixtures. Full voltage must be available at the pump motor at all times. OPERATION Check level of water in tank. Be sure valves are open and strainers and aerators are clean. Open all faucets, hot and cold. Turn on power to pump. Close each faucet when it starts to deliver a steady stream of water (close cold water first). Observe the pump. Check to be sure pump stops soon after all faucets are closed. Pump is now ready for automatic operation. It will start when a faucet is opened and stop when the faucet is closed. Turn off power to pump and open faucet to relieve system pressure prior to city water or dockside hook-up and when unattended. MAINTENANCE WINTER STORAGE Jabsco pumps, with their unique pulsation dampener, will withstand frozen water without damage provided the system is not under pressure prior to freezing. To prevent accidental damage, the entire water system should be protected from freezing during winter storage. This requires complete draining, using the following directions and/or vehicle manufacturer's instructions:

1. Open all faucets and drains and allow pump to empty water tanks and intake line. Run the pump dry for 1 to 2 minutes before turning off. 2. With all drains open, blow air through city water entry. Allow time for water heater to empty. 3. Disconnect discharge and intake hoses from the pump. Start the pump and allow to run until all water is expelled from unit. (Running dry will not harm the pump). 4. Reconnect the hoses, close the drains and leave faucets open. The water distribution system is now dry and ready for winter storage. An alternate method is to use potable water system anti-freeze solution. Follow directions of anti-freeze manufacturer. DO NOT USE AUTOMOTIVE TYPE ANTI-FREEZE. IT IS POISONOUS. USE OF THIS TYPE OF ANTI-FREEZE WILL CAUSE SERIOUS INTERNAL INJURY OR DEATH. SERVICE TROUBLESHOOTING Problem Pump operates but no water flows through faucet. Pump cycles on and off when faucets are closed. Pump operates roughly and has excessive noise and vibration. Pump fails to start when faucet is opened. Pump fails to stop when faucets are closed. Cause Low water level in tank. Water lines are clogged. Kink in water hose. Air leak suction. Dirty or hard-to-open in-line check valve. Defective pump valve Water leak in plumbing. Defective toilet flush valve. Internal leak in output valve. Intake line is restricted, kink in suction hose or fittings too small. Pump mounted on flimsy board. Deformed or ruptured pulsation dampener in pump. Loosened screws at pulleys and connecting rod. Worn connecting rod bearing. Clogged piping. No voltage to pump. Defective pressure switch. Empty water tank. Insufficient voltage to pump motor. Defective pressure switch. DIAPHRAGM & CONNECTING ROD REPLACEMENT 1. Remove motor and four jack shaft assembly tie down screws, then lift jack shaft and attached diaphragm assembly from pump base. 2. Expose diaphragm by removing two diaphragm retainer screws and detaching retainer. 3. Remove diaphragm screw to separate diaphragm, plates and washer/spacer from connecting rod. Inspect diaphragm for cuts and ruptures. 4. Remove locking nut to separate connecting rod from jack shaft. 5. When reassembling, be sure to align diaphragm and connecting rod so that rod slips straight onto jack shaft and diaphragm rests squarely on diaphragm retainer. 6. Replace motor, do not overtighten belt. PULSATION DAMPENERS REPLACEMENT 1. Remove nine screws from bottom plate and three screws from small bottom plate. Mark bottom of small plate for proper reassembly. 2. Pull out rubber pulsation dampeners from base. Inspect for excessive deformation, ruptures and cuts. 3. When installing new large pulsation dampener, check that its metal screw sleeve-guide is positioned between center hole and screw-way in the base. Make sure that flanges of both pulsation dampeners are well-seated to effect a proper water and air seal. SWITCH REPLACEMENT PROCEDURE A Direct replacement of switch with threaded stem directly into pump body. 1. Disconnect power leads from switch and remove switch from pump. 2. Moisten rubber side of washer with water. Thread washer onto switch threads with metallic side of washer facing switch. Apply a thin film of sealing compound to the replacement switch threads. Keep compound clear of passage-way hole. 3. Screw replacement switch into pump base/body until snug. 4. Reconnect switch power leads. MOTOR REPLACEMENT 1. Remove two motor nuts to separate motor. 2. Loosen set screw to remove small pulley from motor shaft. 3. When reassembling, adjust belt tension so belt between pulleys can be depressed 1/4" after motor nuts are tightened. Do not overtighten belt. NOTE 1 Low Pressure Switch 10(0.7) to 20(1.4) psi NOTICE: Before servicing pump, turn off power and open faucets to relieve pressure in water distribution system. Failure to do so could cause water to spray in cabin. VALVES ASSEMBLY REPLACEMENT 1. Remove motor and four jack shaft assembly tie down screws. Lift jack shaft assembly to expose valves. 2. Lift valves from pockets. Clean all foreign materials from valves and seats. Inspect rubber flappers for cuts. 3. Reinstall valves into same pockets, being sure rubber valve with small hole is UP on intake and rubber valve without the small hole is DOWN on discharge. NOTE: Do not use valve with small hole in rubber on discharge side of pump or pump will operate incorrectly. 4. Replace motor, do not overtighten belt. NOTE 2 Includes Switch and Conversion Kit to Mount New Style Switch Onto Older Style-J and -0000 Pumps. NOTE 3 Replacement Switch only for -1000 Series Pumps. Meets USCG Electrical Standards. NOTE 4 1/2" Threaded Outlet Port 37050-0001 1/2" Threaded Inlet Port 37050-0000 NOTE 5 Jack shaft assembly kit, with part number ending in -0001 includes new style connecting rod (37173-0001) with a 5/16" diameter hole and two (2) locknuts. Previous model pumps use a connecting rod (37173-000) with a 1/4"diameter hole and a bolt.

36800-SERIES EXPLODED VIEW Indicates items included in Hardware Kit (Key 21). 36900-SERIES EXPLODED VIEW Indicates items included in Hardware Kit (Key 21). PARTS LIST 36800-SERIES PARTS LIST 36900-SERIES Key Part Description Part Number Qty 1 Motor Kit 12 Vdc. 30200-0000 1 1 Motor Kit 24 Vdc 30200-0010 1 Motor Kit 32 Vdc 30200-0020 2 Motor Mount 34628-0000 1 3 Small Pulley 37169-0000 1 4 Large Pulley 37170-0001 1 5 Belt 30021-0000* 1 6 Jack Shaft Assembly 35506-0001 See Note 5 1 7 Connecting Rod Assembly 37173-0001 See Note 5 1 8 Diaphragm Plate 35503-0000 2 9 Diaphragm 30015-0000* 1 10 Retainer 35497-0000 1 11 Valve Set (Inlet & Outlet) 30004-0000* 1 Set 12 Base Assembly 35625-1100 1 13 Pressure Switch 37121-0010 See Note 3 37121-0000 See Note 2 44814-1000 See Note 1 1 14 Micro Switch only 18753-0141 1 15 Ports (Inlet & Outlet) Barb 37176-0000 See Note 4 1 Set 16 Small Pulsation Dampener 37177-0000* 1 17 Pulsation Dampener 37178-0000* 1 18 Small Bottom Plate 35628-0000 1 19 Bottom Plate 35623-0000 1 20 Vibration Pad Kit 37180-0000 1 Set 21 Hardware Kit 37165-0001 1 Set Service Kit * 30122-0000 Key Part Description Part Number Qty 1 Motor Kit 12 Vdc 30200-0000 1 1 Motor Kit 24 Vdc 30200-0010 1 Motor Kit 32 Vdc 30200-0020 2 Motor Mount 34628-0000 1 2A Brace (Left) 35256-0010 1 2B Brace (right) 35256-0020 1 3 Small Pulley 37169-0000 1 4 Large Pulley 37170-0001 1 5 Belt 30021-0000* 1 6 Jack Shaft Assembly 35690-0001 See Note 5 1 7 Connecting Rod Assembly 37173-0001 See Note 5 1 8 Diaphragm Plate 35212-0000 2 9 Diaphragm 30016-0000* 1 10 Retainer 35173-0000 1 11 Valve Set (Inlet & Outlet) 30004-0000* 1 Set 12 Base Assembly 35625-1100 1 13 Pressure Switch 37121-0010 See Note 3 37121-0000 See Note 2 44814-1000 See Note 1 1 14 Micro Switch only 18753-0141 1 15 Ports (Inlet & Outlet) Barb 37176-0000 See Note 4 1 Set 16 Small Pulsation Dampener 37177-0000* 1 17 Pulsation Dampener 37178-0000* 1 18 Small Bottom Plate 35628-0000 1 19 Bottom Plate 35623-0000 1 20 Vibration Pad Kit 37180-0000 1 Set 21 Hardware Kit 37165-0001 1 Set Service Kit * 30121-0000 * Indicates Parts Contained in Service Kit. Indicates Parts Supplied with Base Assembly. THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE JABSCO ONE YEAR LIMITED WARRANTY, WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST.

For technical advice or service please take your pump into your local pump service center. To order pump or parts or for pricing please go to the following links : Jabsco Pumps Home >> Jabsco Pumps stock list >>