Vacuum Plumbing Layout Recommendations

Similar documents
Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE

Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e

Installation & Operation

PRE-INSTALLATION GUIDE

PowerVac G Single to Twin Conversion Kit [ ]

PRE-INSTALLATION GUIDE for MODELS

PRE-INSTALLATION GUIDE

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

PRE-INSTALLATION GUIDE for MODELS

USER MANUAL/Installation Instructions LRV-4

STERI-VAC CENTRAL SUCTION SYSTEM

INTELLIGENT SUCTION. Upgrade-AtoB

VetPro Solo Installation

Read Only Document Not For Distribution

Special Requirements For Health Care Facilities

DENTAL VACUUM SYSTEM Part Numbers: VS2O, VS40, VS50, VS50H, VS80 and VS80H RECOMMEND DAILY USE OF MONARCH CLEANSTREAM USER S MANUAL

Residential Piping and Long Line Guideline

Performer Cuspidor. Installation Instructions. (For Performer III Chair & International Performer I Chair) You Will Need. About This Install

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

Introduction to Supermarket Vacuum Condensate Drainage Systems by AcornVac, Inc.

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

Install Configurations

Freestanding Treatment Console Installation

V A CUUMS M A K E S Y O U R P R A C T I C E P E R F E C T

Utility Room Accessories. Take your equipment s performance to the next level.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

BIG BOOT COMBUSTION AIR KIT Model: CAS-2BB, CAS-2CB, CAS-2B375

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation th Terrace North Clearwater, Florida 33762

Classic Twelve O clock Cabinet Installation Instructions

EXAIR's compressed air operated Reversible Drum Vac System attaches

User s and Installation Manual

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS


4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

Mojave. Superior Performance. Energy Efficiency. All In A Singular Dry Vacuum.

Installation Instructions. Revision Date: 05/16/12

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

COMBUSTION AIR SYSTEM Model: CAS-3

Procenter Delivery Systems. [Includes: Delivery Units and Assistant s Units (All Styles)] (no serial numbers on Assistant s Units)

MATERIALS Traps TRAPS. No. IPC IRC Description

Va c S t a r V a c S t a r N e o. More Performance. Less Water. Less Energy.

Installation Guide & Owner s Manual

Model LF-310 Air Operated

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98

A. P. E. CORP. EX-675 PNUEMATIC DESOLDER STATION

COMBUSTION AIR SYSTEM

Artizan Ortho-Pedo Bench Installation / User Manual

Sidekick Pro Rinse Assist Installation and Operation Guide

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

Unlimited Mobility. The Mobile Dental Units From. B-Productions

Modular Panel System for Radiant Floor Heating.

Cattani Catalogue. Suction Compressors Plant solutions Suction system care Amalgam Retention CONTENTS

Commercial Water Heating System (CWHS)

CPX RIGID PENDANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

Reve rsib le D rum Vac. Pump 55 gallons in 90 seconds! Two-way pumping action!

Single Wet Vacuum Pump

Ocean Breeze Split System. General Installation Manual. Ocean Breeze 2951 SE Dominica Terrace Stuart, Florida Tel:

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

Installation Instructions

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

24 VAC SYSTEM CONTROL KIT

CLASSIC. SIDE CABINET Installation Instructions

HOT WATER BOILER ( MBH)

3200 SERIES VACUUM CONVEYOR Special Capabilities Specification Sheet

SPEAKMAN SAFETY PRODUCTS Installation Instructions SEF-TW

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

Whirlpool Spa PARTS CATALOG MODEL #F ISSUE DATE: 6/95 CATALOG #G766000

Potable Piping System

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

FT1000S ENERGY RECOVERY STEAM Flight-Type Dishwashing Machine FT SERIES FT1000S ENERGY RECOVERY STEAM STANDARD FEATURES SPECIFIER STATEMENT

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00

Installation Instructions

CHAPTER 9 VENTS SECTION

DISHWASHER INSTALLATION INSTRUCTIONS

English Piping Guide Vacuum Piping Guide, Building :04

C1210ES Tankless Water Heater

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

APPENDIX J ILLUSTRATIONS

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

Appendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan.

FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine FT SERIES FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER

Essential Utilities. Your practice depends on dental compressed air and vacuum. AirStar. STS. VacStar. Steadfast reliability for your peace of mind.

347002K/177002K/34900

Ray Ralph. President R.E Morrison Equipment Manufacturer of BaseVac Dental Suction Systems

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

COBRA -300H EXTRACTOR

DISCARD DECANTER IF: FAILURE TO COMPLY RISKS INJURY FUNNEL CONTENTS ARE HOT ILLUSTRATED PARTS CATALOG

Commercial Spotter Model number PS35

Transcription:

Vacuum Plumbing Layout Recommendations Intended Use To provide general dental vacuum plumbing layout recommendations per industry standards. Installation should be conducted by qualified dental/plumbing professionals. Applies to Models: Power Vac G Power Vac (Std) Classic Series Wet Ring Power Max Special Tools: none Language of origin: English Limitations of Recommendations This Midmark document is designed to provide general vacuum plumbing recommendations commonly used in the dental industry. Midmark does not have expertise in building construction or detailed information about a specific buildings construction. Therefore, Midmark is unable to provide recommendations for specific pipe and fitting locations. Equipment Alert Vacuum systems must be installed per local plumbing and electrical codes. 2015 Midmark Corp. 60 Vista Drive Versailles, OH 45380 USA 1-800-643-6275 1-937-526-3662 004-1130-00 Rev. A (11/24/16) 1

Vacuum Plumbing Specifications Power Vac G Intake (Suction) Line Single Models G3, G5, G7 Twin Models G6, G10, G14 Type Line Size PVC Sch 40 Pipe Recommended - for Main Trunk and Branch Lines Refer to: "Site Requirement Layout", located in this document. Pump Termination 2 Power Vac std Intake (Suction) Line Single Models P3, P5, P7 Twin Models P6, P10, P14 Type Line Size PVC Sch 40 Pipe Recommended - for Main Trunk and Branch Lines Refer to: "Site Requirement Layout", located in this document. Pump Termination 2 Wet-ring Intake (Suction) Line Single Models CV3, CV5 Twin Models CV6, CV10 Type PVC Sch 40 Pipe Recommended - for Main Trunk and Branch Lines Line Size 1 Hose hose Pump Termination NPT connection 1 1/4 NPT connection Power Max Intake (Suction) Line Model PM2 Model PM3 Model PM4 Type Operatory Termination Type K or L Copper Tubing - *Note: Do Not use compression fittings for vacuum lines. Line Size 5/8 OD copper * Device/Conditions User Rating High-volume Ecavuation (HVE) 1 Saliva Ejector 1/2 Hand Wash Station 1 Nitrous Oxide Scavenger 1/2 Main Vacuum line 50 ft. (15m) 1 Branch Vacuum Line 50ft. (15m) beyond 1 main line * NOTE: The number of devices and/or plumbing conditons will add to the total number of users. Number of Users (See Note) Vacuum line pipe size (inches) 1 3/4 2 3/4 3 1 4 1 5 1 1/4 6 1 1/4 7 1 1/2 8 1 1/2 9 1 1/2 10 2 11 2 12 2 2015 Midmark Corp. 60 Vista Drive Versailles, OH 45380 USA 1-800-643-6275 1-937-526-3662 004-1130-00 Rev. A (11/24/16) 2

Below floor or at floor level plumbing General Recommendations Vacuum Piping to be Type M Copper or Schedule 40 PVC per product specs and local code. Main trunk lines must have a minimum slope of 1/4 inch per 10 feet towards the pump. Use drain,waste and vent (DWV), or 45 deg. elbows. Down size the main trunk line after every few junction boxes or branches in order to maintain sufficient suction in operatoires farthest from the vacuum. Every 50 feet of main trunk line should be considered a user. Attempts should be made to limit branch lines, orient main trunk lines below junction boxes or cabinets. Some applications may require the main trunk line to be split, attempts should be made to equalize flow in both directions. Always stagger branch lines from main trunk, do NOT use 4-way cross fittings. Large applications may require multiple vacuums and dividing the operatoires into zones in order to maintain sufficient suction. Power Vac ( G / STD ) specific recommendations 6 feet maximum height from main trunk line to the pump. When using in an oral surgery environment we recommend using the surgical operatory recovery room packages to collect everything and prevent build up/clogs in the lines and vacuum tank. Wet-ring specific recommendations 4 feet maximum height from main trunk line to the pump. 3

Below Floor - Sample Plumbing Layout Line Termination at Vacuum Pump To Junction Box / Inlet (Branch Plumbing) To Vacuum Pump Inlet Riser Pipe - 24 Max. / 10 Min. 45 Elbows Floor Level Centerline Of Floor Level Piping Main Line From Operatories Low Restriction Trap (6 Max.) Main Line Reducer Bushing PVC Equipment Room Main Trunk Line 12 Branch Line Typical 6 12 AA2252 Equipment Alert When performing positive pressure leak tests to validate plumbing installation, verify vacuum systems are not connected to office piping. 4

Below Floor - Sample Plumbing Layout (Split Trunk Line) Additional Recommendations In certain situations it is necessary to split the main trunk line in different directions. When doing this take into consideration the potential volume on each line and size them accordingly. Use 45 deg. fittings flowing back towards the vacuum. Branch Line Typical 2 2 2 Main Trunk Line Equipment Room 5

Below Floor - Large Application, Multiple Pump, Multiple Zones ZONE 1 All Branch Lines Typical ZONE 2 ZONE 3 Main Trunk Line Equipment Room 2 2 Main Trunk Line Additional Recommendations Large applications may require multiple vacuums and dividing the operatoires into zones in order to maintain sufficient suction. Attempts should be made to equalize flow in both directions and size plumbing according to potential volume. 6

At Floor Level - Sample Plumbing Layout (Split Trunk Line) Additional Recommendations In certain situations it is necessary to run the main trunk line at floor level along the wall. When doing this follow the recommendation for plumbing below floor level. Avoid running lines through doorways and other traffic areas. Main Trunk Line Branch Line Typical Equipment Room 7

Overhead Plumbing General Recommendations Vacuum Piping to be Type M Copper or Schedule 40 PVC per product specs and local code. Main trunk lines must have a minimum slope of 1/4 inch per 10 feet towards the pump. Use drain,waste and vent (DWV), or 45 deg. elbows. Down size the main trunk line after every few junction boxes or branches in order to maintain sufficient suction. Every 50 feet of main trunk line should be considered a user. Attempts should be made to limit branch lines, orient main trunk lines in close proximity to the vertical vacuum lines Some applications may require the main trunk line to be split, attempts should be make to equalize flow in both directions. Micro Mini Muffler / Vacuum Relief Valve (VRV) to be Installed at top of vent line in each operatory. Each Micro Mini Muffler / Vacuum Relief Valve VRV is considered 1/2 of a user. Maximum height of riser to the main trunk line trap is 10 feet. (A loss of hg per 18 of rise limits height of trunk line.) It may be necessary to upgrade to the next size vacuum for systems with over head plumbing depending on the office size and usage. All risers need to be plumbed into the top of the main trunk line through a trap. We do not recommend combining overhead pluming with below floor plumbing due to the different performance characteristics. When using in a oral surgery environment we recommend using the surgical operatory recovery room packages to collect everything and prevent build up/clogs in the lines and vacuum tank. Operation efficiencies must be considered I.E.: holding vacuum tips open longer in operatory s to allow flow up walls to help prevent gurgling in plumbing 8

Overhead plumbing - Sample Plumbing Layout All Vertical Vent Lines are 1/2 Installed with VRV Above Inverted P-Trap. Allows Air Into System to Minimize Gurgling in Vacuum Lines 77005027 Micro Mini Muffler / VRV to be Installed at Top of Vent Line in Each Operatory to Keep Air Flow Pushing Liquids Up the Wet Line After HVE or SE is Closed Inverted P-Trap Use 45 0 Y s and elbows only Scavengers Should be Installed on the Vent Line to Prevent Backflow of Fluids Into Scavenger Equipment Alert Subfloor plumbing is preferred. Operatory utilization to be modified to allow flow up walls. Up size pump as per number of operatories. At least 1/2 user per VRV and 8 ft. riser. More than 8 ft. riser requires more pump capacity. VRV is 1/8 MPT a 1/8 FPT fitting will need to be soldered to the top of the 1/2 vent line. 1 1/2 1/2 Trunk Lines: Follow Sizing Guide Under Floor Installation and Add One User All Vertical Wet lines are 1/2 Vacuum Piping to be Type M or Schedule 40 PVC Maintain a 1/4 Slope per 10 feet of Piping (toward pump). Always Stagger Branch Lines From Main Trunk, Do Not Use 4-way Cross Fittings. 9

Overhead plumbing - Sample Plumbing Layout (Split Trunk Line) 77005027 Micro Mini Muffler / VRV to be Installed at Top of Vent Line in Each Operatory to Keep Air Flow Pushing Liquids Up the Wet Line After HVE or SE is Closed 1 Scavengers Should be Installed on the Vent Line to Prevent Backflow of Fluids into Scavenger All Vertical Vent Lines are 1/2 Installed with VRV Above Inverted P-Trap. Allows Air Into System to Minimize Gurgling in Vacuum Lines 1 Use 45 0 Y s and elbows only Equipment Alert Subfloor plumbing is preferred. Operatory utilization to be modified to allow flow up walls. Up size pump as per number of operatories. At least 1/2 user per VRV and 8 ft. riser. More than 8 ft. riser requires more pump capacity. Inverted P-Trap 1/2 1/2 All Vertical Wet lines are 1/2 Trunk Lines: Follow Sizing Guide Under Floor Installation and Add One User 1/2 Vacuum Piping to be Type M or Schedule 40 PVC Maintain a 1/4 Slope per 10 feet of Piping (toward pump). Always Stagger Branch Lines From Main Trunk, Do Not Use 4-way Cross Fittings. 10

Oral Surgery Plumbing Recommendations General Recommendations (Power Max) Vacuum Piping to be Type M Copper or Schedule 40 PVC per product specs and local code. A Surgical Operatory Recovery Package is required for all Power Max applications. All liquids and solids should be collected in the Surgical Canister and disposed of per local codes prior to reaching the vacuum lines. Down size the main trunk line after every few junction boxes or branches in order to maintain sufficient suction. Every 50 feet of main trunk line should be considered a user. Attempts should be made to limit branch lines, orient main trunk lines close junction boxes or cabinets. Some applications may require the main trunk line to be split, attempts should be make to equalize flow in both directions. There is no loss of suction when overhead pluming is used in conjunction with the Surgical Operatory Recovery Package due to no liquids or solids moving through the vacuum lines. Power Vac ( G / std ) specific recommendations When using in a oral surgery environment we highly recommend using the surgical operatory recovery room packages to collect everything and prevent build up/clogs in the lines and vacuum tank. When electing not to use the Surgical Operatory Recovery Package and collecting waste in the Power Vac collection canister, thorough line cleaning should be done after every procedure and the end of the day. The collection tank will also need rinsed periodically. When using the Power Vac style vacuum in this application the lines will have to be constructed with drain,waste and vent (DWV), or 45 deg. elbows (follow Overhead or Through the Floor specifications previously stated in this guide). 11

Oral Surgery - Sample Plumbing Layout (Split Trunk Line) Equipment Alert Subfloor plumbing is preferred. Operatory utilization to be modified to allow flow up walls. Upsize pump as per number of operatories. At least 1/2 user per VRV and 8 ft. riser. More than 8 ft. riser requires more pump capacity. Equipment Room Main Trunk Line At Each Termination Surgical Operatory Recovery Package 1 5/8 Branch Line Typical AA206600 Vacuum Piping to be Type M or Schedule 40 PVC Maintain a 1/4 Slope per 10 feet of Piping (toward pump). Always Stagger Branch Lines From Main Trunk, Do Not Use 4-way Cross Fittings. 12

13