CONDENSATE MANAGEMENT SYSTEMS

Similar documents
CONDENSATE MANAGEMENT SYSTEMS

Safe-T-Switch 13 EZ Trap 17 AquaGuard 20 Condensate Pans & Risers 29. Acid-Detector 40 Acid-Detector for POE 40 Oil-ID 40 Turbo-Kleen 41

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

Model 1820 Dehumidifier

LIFTAIRE II ELEVATOR AIR CONDITIONER

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

HVAC-R Product Catalog

Safety and Installation Instructions Model 1700

Wolff Bros. Supply, Inc. Services

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

PRO Installation. Thermostat Wi-Fi

LEAKSTOPPER 1 Single zone water leak detection system

PRO Installation. Touch Wi-Fi Thermostat

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

WE VE MADE OUR 90% FURNACES 100% EASIER. (Our 90% furnaces now make you more efficient, too.)

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

Rheem Ingenuity. Innovation And Then Some. New Prestige Series High Efficiency Water Heaters

LEAKSTOPPER RANGE Multizone water leak detection systems

Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe

PRO Installation. Touch Wi-Fi Thermostat

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

RHEEM 90%+ GAS FURNACES

Consumer Products Catalog

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

EVAPORATIVE COOLER PUMPS

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

Installation, Safety & Maintenance Manual Model 1750A/1770A

Smoke Alarm User s Manual

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

15 Minute Training Module

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

Water Leak Detector. Installation and Troubleshooting. Overview

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

TECHNICAL SPECIFICATIONS

Hi-Tech, Low Cost Stanley Solutions. Product Brochure

MicroRay IR-100 NEW. Inspection MicroRay IR-100

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

CHECKFIRE 210 Detection and Actuation System

Operating Instructions. For. Alarm Control Module. Model SSR 500

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

Heat Pump Water Heater. Table of Contents

CU1526, CU2026, CU3030 Service Parts

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Product Catalog. Condensate Removal Ice Machine Replacement Evaporative Cooler Accessories. Engineered Products HVAC. Industrial

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

I/O ZONE 560/583 AND OPERATION MANUAL

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

Nexus FS Filtration Installation Guide. September 19, 2011

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Addendum for STI-6406 with Dual Access Control

SpeedClean. Work Smarter NEW! Innovative cleaning products for maximum HVAC system efficiency. Innovative Maintenance Tools.

Safety, Installation, and Operation Manual

WARNING Important Safety Information

Model 1850F Dehumidifier Installation and Operating Manual

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Gobi II. English. Condensate Pump Instruction manual Gobi II

Model 1870F Dehumidifier Installation and Operating Manual

Installation Instructions

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.


Columbia Boat Alarms, Inc.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Oil Heating. Low Profile Highboy Furnaces OH6, OD6, OH8 Series. Built Tough for Lifetime Comfort

HE120, HE160 Humidifier Installation Kit

Digital Marine Exhaust Temperature Alarm

RCS MODEL ZC2S 2 ZONE HVAC CONTROL UNIT INSTALLATION AND OPERATION MANUAL DCN /25/03

Models Product Information. Important Safety Instructions REV

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

ALARMED EXIT HARDWARE

AND WORRY-FREE PERFORMANCE

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

Scotsman Technical Training. CU50 Cube Ice Machine

INSTALLER S GUIDE ART COOL SERIES FLOOR STANDING SERIES DUCT-FREE SPLIT AIR CONDITIONING SYSTEMS

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

We ve Got Panels Under Control.

Safety & Installation Instructions

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

THERMOSTATS. 100-Series. 200-Series. 300-Series. 400-Series. 500-Series. Model Number Identification UHC TST 101 GE MS

product guide The most complete range of ancillary essentials designed specifically for the HVAC/R industry

Using the DewTrak II Dew Point/ Humidity Transmitter

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Transcription:

CONDENSATE MANAGEMENT SYSTEMS

AG-1100+ Magnetic Float Switch System for Metal Secondary Drain Pans The AG-1100+ is incredibly easy to install. It can be mounted to the drain pan in 10 seconds or less. Installation does not require any pre-drilling for screws. The AG-1100+ incorporates a protective cover to keep out insulation and debris that could prevent the float from rising. Features: High Capacity 5 Amp, 24Volt AC Magnetic Float Switch Easy, Drill-Free Installation Residential and Commercial Applications Pull Up Test Knob Protective Housing Keeps Out Insulation, Pests, and Debris Normally Open 3rd Wire for Optional External Alarm, Digital Controller, or Energy Management System US Patent 7,710,283 75MF Just pull the knob up to test. Product Code 96100 AG-1200+ Magnetic Float Switch For Metal & Plastic Secondary Drain Pans The AG-1200+ has all of the features of the 1100+ plus an innovative two-piece clamp design which allows it to be mounted to a metal secondary drain pan (without a lip) or a plastic secondary drain pan (with a lip) in 10 seconds or less, without screws or drilling. Product Code 96106 Features: High Capacity 5 Amp, 24Volt AC Magnetic Float Switch Easy, Drill-Free Installation Residential and Commercial Applications Pull Up Test Knob Protective Housing Keeps Out Insulation, Pests, and Debris Normally Open 3rd Wire for Optional External Alarm, Digital Controller, or Energy Management System US Patent 7,710,283 75MF C-14

NEW and IMPROVED Now with Adjustable Height Mount AG-1250E AG 1250E MULTIPURPOSE WATER SENSOR METAL/PLASTIC SECONDARY DRAIN PANS Product Code 96108 The AG-1250E multipurpose water sensor is mounted directly in a metal or plastic secondary pan, floor or wall. The AG-1250E is a high-amperage, solid state sensor with no moving parts to break down or become clogged. The low profile design makes it easy to install. PRODUCT SPECS Normally Open or Closed Voltage Rating: 24 VAC, 5 Amp Normally Open 4th Wire for Optional External Alarm, Digital Controller or Energy Management Systems Switch can be normally open or normally closed Versatile mounting options allow positioning on the unit, in a secondary pan, floor or wall 5 Amp, 24 Volts AC solid state sensor Clip on mounting base for easy cleaning and drying of sensor NEW adjustable height mount 25XE Metal Contacts Can be mounted with double sided tape, adjustable height clip or screw. Proprietary design sensors can detect as little as 1/16 of water. C-14 US Patent 8,578,770

AG-2550E INLINE WATER SENSOR FOR PRIMARY DRAIN LINE AND SECONDARY DRAIN PAN The AG 2550E electronic water sensor is designed for use on the primary drain line and is integrated with an access port for clearing and removing clog causing debris. The water sensor has no moving parts and the unique design of the insulated housing allows the application of chemicals to clean the drain without any worry of retrograde backflow into your HVAC unit. Electronic In-Line Water Sensor and Insulated Access Port for Primary Drain Lines. Unobstructed 3/4 Inch Flow-Switch does not Impede Drainage. Integrated Easy Access Port for Cleaning Out Drain Lines and Adding Chemicals. Bonus Secondary Sensor with Water Detection LED Light for secondary drain pans 2 SENSORS, ONE PRICE. Normally Open 4th Wire for Optional External Alarm, Digital Controller or Energy Management Systems. HORIZONTAL INSTALLATION VERTICAL INSTALLATION US Patent 8,154,313 & 8,578,770 Product Code 96110 E-14

AG-3125E AG 3125E ONE PRIMARY PAN CONDENSATE SENSOR The AG-3125E primary pan sensor is mounted directly in the auxiliary drain port of the primary pan. The AG-3125E is a highamperage(5amp), solid state sensor with no moving parts to break down or become clogged. Voltage Rating: 24 VAC, 5 Amp Time Delay Water Detection LED New uick Pull Adhesive Tape Available in: Single Product Code 96120 3 Pack Product Code 96121 25XE 6 Pack Product Code 96122 US Patent 8,151,580; 8,154,313; 8,561,417 & 8,578,770 E-14

AG-3150E AG-3175E Plenum Rated AG-3150E & AG-3175E Plenum Rated Primary Pan Sensors with Time Delay The AquaGuard AG-3150E/AG-3175E s primary pan sensor is mounted directly in the auxiliary drain port of the primary drain pan. The bonus secondary sensor can be installed either vertically or horizontally and features a water detection LED. For a vertical application, the bonus secondary sensor can be mounted on the side of the unit. For a horizontal application, the bonus secondary sensor can be installed directly in the metal or plastic secondary drain pan, which allows both sensors to continuously monitor any condensate overflow in both the primary and secondary drain pans two sensors in one. If any condensate overflow is detected in either drain pan, the sensor(s) will automatically shut off the system and activate an optional alarm. Patent Pending Smart Sensor Technology with Time Delay Redesigned Probe Sensor for Increased Reliability Bonus Secondary Sensor Two Sensors for the Price of One 6 Feet of Both Probe & Sensor Wire (A -31 5E Plenum Rated Probe Sensor Wire) 5 Amp, 24 Volts AC Solid State Sensor with Water Detection LED Light Switch Can Be Normally Open or Normally Closed Compact Waterproof Design Normally Open 4th Wire for Optional External Alarm, Digital Controller or Energy Management Systems (Mounted to Side of Unit) (Inside Primary Pan) 25XE (Inside Secondary Pan) Product Code 96124 (AG3150E) 96126 (AG3175E) US Patents 8,151,580; 8,154,313; 8,561,417; 8,561,417; 8,578,770 E-14

IDEAL FOR COMMERCIAL PACKAGE UNITS, METAL/PLASTIC SECONDARY DRAIN PANS & PRIMARY PAN WITH TIME DELAY The AquaGuard AG-3180E micro-electronic condensate sensor is mounted directly in the primary drain pan. The bonus secondary sensor features water detection LED and easily installs in the metal or plastic secondary drain pan. Both sensors continuously monitor any condensate overflow in the primary and secondary drain pans and automatically shut off the system and activate an alarm if any overflow is detected. Micro Pan Sensor Plus Bonus Secondary Sensor with Water Detection LED Meets International Building Codes & Primary Pan Code Requirements Now with Time Delay: Up to 60 Seconds On 6 Feet of Both Plenum Rated Probe and Sensor Wire 5 Amp, 24 VAC Solid State Sensor with Patent Pending Smart SensorTechnology Switch Can Be Normally Open or Normally Closed Normally Open 4th Wire for Optional External Alarm, Digital Controller or Energy Management Systems 25XE Product Code 96128 International Mechanical Code 30.2.3.1: On downflow units and all other coils that do not have a secondary drain or provisions to install a secondary or auxiliary drain pan, a water-level monitoring device shall be installed inside the primary drain pan. This device shall shut off the equipment served in the event that the primary drain becomes restricted. Devices installed in the drain line shall not be permitted. E-14 US Patent 7,744,395; 8,151,580; 8,151,621; 8,154,313; 8,169,314; 8,561,417; 8,578,770

AG-3575E AG-3575E COMPLETE ALL-IN-ONE CONDENSATE MANAGEMENT SYSTEM The AquaGuard AG-3575E is the all-in-one solution for a complete and professional HVAC installation. Given the multiple installation options, the AG-3575E is the perfect solution for commercial or self-contained package units, primary pans and metal or plastic secondary drain pans. The AG-3575E includes 3 sensors: Inline electronic water sensor for Primary Drain line Primary pan sensor (Clip-on or Probe) Secondary drain pan sensor High amperage rating: 5 AMPS, 24VAC 3 Sensors: Primary drain line sensor, Primary pan sensor, Secondary pan sensor Meets both International Building codes and Primary pan code requirements Total of 18 ft of plenum-rated control and sensor wire Bright water detection LED Indicator light for easy diagnostic PVC fittings that allow for vertical/horizontal installation Listed AG-2550E 25XE AG-3176 Mounting Clips Can Be Adjusted for Depth of Pan Water Detection LED Light Proprietary design sensors can detect as little as 1/16 of water. Can be mounted with double sided tape or screw. US Patent 8,154,313 & 8,578,770 Product Code 96130 E-14

AG-4200E AG-4200E PRIMARY PAN SENSOR New Electronic Multipurpose Condensate Overflow Sensor We ve combined the proven water sensing technology of the AG-1250E with our industry leading Goliath and Titan drain pan line to deliver the ultimate condensate management system. The AG-4200E is the complete condensate management system for Goliath, Goliath Furnace, Goliath Value Series nd Titan Drain Pans. Includes Vibration Isolators Product Code 96143 US Patent 8,578,770; 8,317,169 3/4 PVC threaded male pipe adapter 24 VAC, 5 Amp 1/4 inch Trigger Depth Smart Sensor Technology Time Delay: Up to 60 Seconds n Controls ormally pen or ormally Closed 6 of Standard Control Wire Compact Waterproof Design Water Detection LED 4th Wire for Alarm E-14

AG-4250E AG-4250E PRIMARY and SECONDARY PAN CONDENSATE SENSOR We ve combined the proven water sensing technology of the AG-3150E with our industry leading drain pans to deliver the ultimate condensate management system. Providing the security of TWO sensors and the durability of our drain pans. The AG-4250E is the complete condensate management system for Goliath, Goliath Furnace, Goliath Value, and Titan Flexible Series Secondary Drain Pans. Includes Vibration Isolators 2 Sensors - Primary and Secondary Pans 24 VAC, 5 Amp 1/4 inch Trigger Depth Smart Sensor Technology (Patent Pending) Time Delay: Up to 60 Seconds n Controls ormally pen or ormally Closed 6 of Probe Wire 6 of Standard Control Wire Compact Waterproof Design Bonus Secondary Sensor Water Detection LED 4th Wire for Alarm Product Code 96148 US Patent 8,578,770; 8,317,169 E-14

AG-9100 External Audible and Visual Remote Alarm The ONLY Multipurpose Remote Alarm Approved For Use With AquaGuard Condensate Management Systems The AG-9100 Audible & Visual Remote Alarm is connected directly to AquaGuard Condensate Management Systems. When activated, the AG-9100 produces an audible and visual signal. Integrated into Most Monitoring Systems (Home Alarm, Water Detection or Condensate Management System, Etc.) 12-24 VAC / 6-32 VDC Circuit, No Battery Required Loud 103db Audible Alert with On/Off Switch Bright White LED Alarm Lights Can be Conveniently Mounted to a Wall, Ceiling, or Directly to a Hot Water Tank or HVAC/R Unit with Two Screws or Included Adhesive Pad Over 250 Feet Away from a Condensate Overflow Switch Included 12 Inches of Lead Wire Product Code 96180 For use with Aquaguard Condensate Management Systems AG-1100+ AG-1200+ AG-1250E AG-2550E AG-3150E AG-3175E AG-3180E AG-3575E AG-4200 Series C-14

AG-9300SERIES AG-9300 SERIES ELECTRONIC CONDENSATE DRAIN SENSOR FOR DUCTLESS MINI-SPLIT SYSTEMS Each system continuously monitors any condensate overflow in the primary drain pan of any ductless mini-split system, and automatically shuts off the system and activates an alarm if any overflow is detected. The AG-9300 Series includes: A - 300-U: (96192) Universal Drain Sensor for Ductless Mini-Split Systems A - 300-MIT: (96194) Drain Sensor for Mitsubishi Ductless Mini-Split Systems A - 300-L : (96196) Drain Sensor for LG Ductless Mini-Split Systems A - 300-CS: (96198) Drain Sensor for Comfort Star Ductless Mini-Split Systems AG-9300 SERIES FEATURES: 75MF Universal Model is Compatible with All Major Manufacturers Ductless Mini-Split Systems Currently on the Market Additional Models Available with Exclusive Wire Harness Connectors for Mitsubishi, L and CS Meets International Building Codes Long Life Lithium Battery Included (Lasts Up To the Life of the Ductless Mini-Split Unit) Up to 20 Second Make/Break Delay with Automatic Reset uick and Easy Installation Low Battery Audible Alert Mounting Clips Adhesive Pad ICC CODE 307.2.3.4 A water-level detection device conforming to shall be provided that will shut off the equipment served in the event that the primary drain is blocked. The device shall be installed in the primary drain line, the overflow drain line, or in the equipment- supplied drain pan, located at a point higher than the primary drain line connection and below the overflow rim of such pan. Patent Pending C-14

AG-9150E AG-9150E MULTIPURPOSE WATER SENSOR & ALARM FOR METAL / PLASTIC SECONDARY DRAIN PANS, ON FLOORS, WALLS BASEMENT INSTALLATIONS The AquaGuard AG-9150E is the ultimate condensate management system for any residential or commercial application. The AG-9150E features our awardwinning AG-1250E Multipurpose Water Sensor combined with our AG-9100 External Audible and Visual Remote Alarm. FEATURES External Audible Visual Remote Alarm with Five Bright White LED Lights 103 Decibel Audible Alert that can be mounted over 250 Feet Away Versatile Mounting Options 5 Amp, 24 Volts AC Solid State Sensor with Water Detection LED Light Innovative Mounting Base for Easy Cleaning and Drying of Sensor Switch Can Be Normally Open or Normally Closed with Automatic Reset 6 Feet of Control Wire Included Sensor Features a Compact Waterproof Design ALARM Mounts Up To 250 Ft. Away from Condensate Switch E-14 Product Code 96190 US Patent 8,578,770

AG-9150E Smart Sensor Technology with Automatic Reset The sensor features patent pending Smart Sensor Technology and includes an automatic reset. Smart Sensor Technology reduces nuisance tripping caused by moisture inside a drain pan and increases the life span of the HVAC/R compressor. The 24 VAC switch can also be set to either normally open or normally closed. Included Alarm The remote alarm has an audible and visual signal and can be installed over 250 away from the water sensor. The loud 103 decibel audible alert can be heard from over 100 feet away. Five (5) bright white LED lights flash and are visible both day and night when the alarm is activated. The alarm is equipped with an on/off switch to silence the audible alarm while keeping the visual alert active. Easy Overflow or Water Detection Upon overflow or water detection, the multipurpose water sensor s bright red LED Light will trigger and activate the remote alarm. With the alarm located in a convenient or highly visible location, there is no need to go up into an attic, on a roof, or down into a basement to check on the status of the HVAC/R unit or location. The water detection LED light and alarm makes troubleshooting and trip detection easy in both well lit and dark locations for any HVAC contractor, business or homeowner. Innovative Mounting Bracket The multipurpose water sensor features an innovative clip on mounting bracket that allows multiple installation options. The mounting bracket can be mounted directly on HVAC/R units, in a metal or plastic secondary drain pan, on floors or even on a wall and elevates the sensors eliminating false tripping. Dries Easily The innovative mounting bracket also allows water to easily reach the sensors and eliminates the need for a hard-to-dry hydrophilic pad. The sensor can also be quickly and easily removed from the bracket for easy cleaning. Compact Design The AG-9150E sensor measures less than 1.4 inches x 2.0 inches (36mm x 50mm) for complete condensate management in any tight space and includes 6 feet of control wire. Solid State Electronics The multipurpose water sensor is a dependable solid state sensor, which can be completely submerged in water and contains no moving parts that could become clogged like a mechanical float switch. High 5 Amp Capacity With a high 5 amperage capacity, the AG-9150E s multipurpose sensor s state-of-the-art electronics are surge protected from the various electrical currents that occur during compressor turn ons and turn offs. The high load capacity ensures that the switch performs again and again and is more reliable than lower Amp capacity switches, which are not designed to handle excessive loads from today s high efficiency HVAC systems. Metal Contacts Can be mounted with double sided tape, adjustable height clip or screw. Proprietary design sensors can detect as little as 1/16 of water. C-14