Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Similar documents
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

EVAPORATIVE LIGHT SCATTERING DETECTORS FOR HPLC

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

Agilent 1290 Infinity II Vialsampler Data Sheet

Q Trap LC/MS/MS TurboIonSpray Ion Source Manual. About This Manual... 1 Conventions Introduction... 3 Features... 4

API 2000 LC/MS/MS TurboIonSpray Ion Source Manual

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

HPLC Column Ovens and Temperature Controllers

DYE QUALITY CONTROL REFERENCE MATERIAL KIT

PUV, PIR and PFO Series BROCHURE

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Mercury Vapor Monitor VM-3000

Agilent 1200 Infinity Series ELSD

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

VM-3000 Mercury Vapor Monitor

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

detectors UltiMate 3000 Variable Wavelength Detectors

CALIDUS tm the Modular micro Gas Chromatograph

Customers should provide all necessary operating supplies upon request of the engineer.

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Nexera-i Specifications Prominence-i Specifications

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

SEC-MALS Noise Assessment and Cleaning Guide

Agilent 1200 Infinity Series ELSD

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

SAM-MAX Refrigerant Monitors

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

ENVAIR lab CO2 Tri-Gas Incubator

Agilent 1100 Series Refractive Index Detector. Reference Manual

BENEFITS. QUATERNARY HPLC SYSTEMS Quaternary and Other Gradients. The Complete Range of HPLC. Convenience of Maintenance. Systems Configuration

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

REAL TIME LABORATORY MONITORING SYSTEM

Orion ionplus 2111LL low-level sodium monitor. The next generation in sodium protection. Analyze Detect Measure Control

Fundamentals of Solid-Phase Extraction (SPE): Principles and Practical Tips for Developing Sample Preparation Methods

Spark Holland introduces

ProStar 325 UV-Vis Detector

An Advanced Heat Exchanger for the Agilent 1290 Infinity Thermostatted Column Compartment

Hydrazine Analyzer Series 2171 Specifications

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Model KBWF 720 Growth chambers with light and humidity

FITOCLIMA 600 & 1200 STABILITY

HFID Heated Total Hydrocarbon Analyzer Module

Series 5000 Hydrazine Analyzer Model 60002

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

VM-3000 Mercury Vapor Monitor

FITOCLIMA 600 & 1200 STABILITY

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

APPLIED. OMA-406R Rackmount Process Analyzer

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Datalogging as standard

Installing the Agilent CE ESI-MS Sprayer Kit (G1607A)

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

OMA-300 Process Analyzer

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

Model KBWF 240 Growth chambers with light and humidity

SystemsQT for Waters Alliance HPLC Systems (Revision G)

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Process Gas Chromatograph

Agilent 1260 Infinity Multi-Detector Suite

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

API LC/MS/MS TurboIonSpray Ion Source Manual Table of Contents

Model C 170 CO 2 incubators with hot air sterilization

IQ/OQ Protocol Installation Qualification/ Operation Qualification

intrinsically safe detector for hydrocarbon gases

User Meeting 8 or 9 September 2015: Laser diffraction Data Quality: Do s and Don ts. User meeting 8 or 9 September 2015 Sysmex

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

FITOCLIMA 600 & 1200 PHARMA

IQ/OQ Protocol Installation Qualification/ Operation Qualification SteamScrubber & FlaskScrubber Laboratory Glassware Washers

ENVAIR lab CO2 Incubator

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Optilab T-rEX. Differential Refractometer with Extended Range. 256 Times the Detection Power 50 Times the Dynamic Range

Specifications Wavelength Range: 190 nm to 800 nm continuous

Technical specifications of FT-IR Spectrometer

PSA Series. Particle Size Analyzer

Atomic Absorption Spectrometer

Parker icount Oil Sampler (IOS)

STABILITY ICH. ICH Stability Tests

Model gffoz Process Ozone Sensor (In-Line)

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

Refrigerated Incubators / Environmental Testing Chambers

Customised HPLC Systems for Highest Performance

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Transcription:

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED LEASING/MONTHLY RENTALS ITAR CERTIFIED SECURE ASSET SOLUTIONS SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full-service, in-house repair center SM InstraView REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www.instraview.com Contact us: (888) 88-SOURCE sales@artisantg.com www.artisantg.com WE BUY USED EQUIPMENT Sell your excess, underutilized, and idle used equipment We also offer credit for buy-backs and trade-ins www.artisantg.com/webuyequipment LOOKING FOR MORE INFORMATION? Visit us on the web at www.artisantg.com for more information on price quotations, drivers, technical specifications, manuals, and documentation

NEW ELSD 2000ES E N H A N C E D S E N S I T I V I T Y More Sensitive Lower detection limits Two Operating Modes Get optimum performance for all applications Universal Detect compounds missed by other detectors Advanced Features Increase productivity and decrease downtime Low Temperature Operation Detect semi-volatile compounds The Most Advanced Is Now Even MORE SENSITIVE Specialists in Chromatography Brochure #497 UNP

FROM THE LEADER IN EVAPORATIVE LIGHT SCATTERING DETECTION The Most Advanced ELSD Is Now Even More Sensitive The ELSD 2000ES has all the benefits of the ELSD 2000 plus even greater sensitivity! The optical and electronic components have been redesigned to minimize background noise and increase sensitivity. The result of this new, patent pending technology is lower detection limits and greater signal-to-noise ratios. The ELSD 2000ES Increases Sensitivity for Equal Concentrations of Hydrocortisone 10463 10464 1. Hydrocortisone (100ng on column) Column: Alltima C18, 5µm, 250 x 4.6mm (Part No. 88056) Mobile Phase: Water:Acetonitrile (55:45) Evaporative Light Scattering Detection in Three Simple Steps 2 1. Nebulization Column effluent passes through a needle and mixes with nitrogen gas to form a dispersion of droplets. 2. Evaporation Droplets pass through a heated drift tube where the mobile phase evaporates, leaving a fine mist of dried sample particles in solvent vapor. 3. Detection The sample particles pass through a cell and scatter light from a laser beam. The scattered light is detected, generating a signal.

ADVANCED INSTRUMENT CONTROL The ELSD 2000ES has many features that enhance detector performance, increase productivity, and decrease downtime Digital Gas Flow Control Digital gas flow control ensures reproducible results. Changing gas flow is fast and easy from the ELSD s front panel or PC control software. Save gas by automatically shutting off gas flow at the end of an unattended run. Program and view method parameters on the ELSD s menu-driven front panel. Store as many as 10 methods. Onboard Diagnostics Decrease downtime with automated troubleshooting, or use diagnostic tests to verify detector functions on start-up. Safe, Unattended Operation Alarm set points ensure tight control of the critical operating parameters. When operating unattended, an output signal can trigger the LC pump to shut down under alarm conditions. Deviations in operating parameters are logged by the type of error at the time it occurs. Comprehensive PC-based control software makes choosing the critical operating parameters of temperature and gas flow a snap. ELSD 2000ES* Specifications Light Source: Laser diode with collimating optics, 650nm, 30mW output, class IIIB Detector Element: Silicon photodiode Temperature Range: Ambient to 120 C in 1 C increments Nebulizer Gas: Nitrogen preferred; Calibrated to 4.0L/min Inlet Pressure: 60-80psig Typical Operating Range: 1.0 3.0L/min Flow Control: Digital mass flow control Mobile Phase Flow Rate: To 5.0mL/min Analog Output: 1V or 10mV full scale Communications: Inputs: TTL/contact closure for auto zero and gas shutoff Outputs: Contact closure for pump shutdown in error conditions User Interface: Graphical LCD with alphanumeric keypad and/or Windows based PC control via serial I/O Power Requirements: 120/240V, 50/60Hz Dimensions: 23.0" H x 12.5" W x 21.6" D (58.4cm H x 31.8cm W x 54.8cm D) Weight: 35lbs (16Kg) IEC/FDA Classification: Class 1 laser product Warranty: 1 year parts and labor *Patent pending 3

OPTIMUM PERFORMANCE WITH ANY APPLICATION Why Two Operating Modes? Splitting Best for semi-volatiles at low temperatures Not Splitting Best for non-volatiles at high temperatures Since an ELSD s response is based on the amount of particles passing through the optical cell, it makes sense that sending 100% of the column effluent would net the highest responses. In most, but not all cases, this is true. Some samples such as semi-volatiles may benefit from lower operating temperatures and gas flows achieved by splitting a portion of the aerosol stream to waste. Only the ELSD 2000ES offers the choice of splitting or not splitting, giving you optimum sensitivity for every application. Splitting Allows Near Ambient Temperature Evaporation, Maximizing Sensitivity for Semi-Volatiles Low Temperature Analysis of Urea 1. Urea (1µg on column) 10307 Column: Prevail Carbohydrate ES, 5µm, 250 x 4.6mm (Part No. 35101) Mobile Phase: Acetonitrile:Water (85:15) Not Splitting is Best for Non-Volatile Samples and/or Organic Mobile Phases Triglycerides in Sesame Seed Oil 1. LLL 2. LLO 3. LLP 4. OOL 5. POL 6. PPL 7. OOO 8. OOP 9. PPO 10. OOS Column: Alltima C18, 3µm, 150 x 4.6mm (Part No. 91387) Mobile Phase: A: Dichloromethane B: Acetonitrile Gradient: Time: 0 10 18 20 %B: 70 55 70 70 Flow Rate: 1.5mL/min 9517 Splitting Maintains Stable Baselines with Rapid, Extreme Gradients LC/MS Screening Performance Test Mix 1. Aspartame 2. Cortisone 3. Reserpine 4. Dioctyl Phthalate Column: Platinum C18, 3µm, 20 x 4.6mm (Part No. 43804) Mobile Phase: A: 0.05% Formic Acid in Water B: 0.05% Formic Acid in Acetonitrile Gradient: Time: 0 3 7 10 %B: 5 90 90 5 Column Temp: 40ºC 10273 4

REPLACE OR COMPLEMENT YOUR EXISTING DETECTOR ELSD Advantages Compared to Other LC Detectors Sensitivity Gradient Capability Baseline Stability Solvent Interference Mass Balance ELSD RI UV MS Chart Key Excellent: Good: Poor: ELSD Obtains a More Accurate Representation of Sample Mass than UV ELSD Shows What May Be Missing From Your UV Chromatogram 1:1 Mixture 1. Ephedrine 2. Caffeine 10450 10449 Lotrimin AF Topical Solution 1. PEG 2. Clotrimazole 10446 10447 Column: Alltima HP EPS C18, 5µm, 150 x 4.6mm (Part No. 87715) Mobile Phase: 1% Acetic Acid:Methanol:Acetonitrile (70:20:10) Flow Rate 1.0mL/min Column: Alltima C18, 5µm, 150 x 4.6mm (Part No. 88302) Mobile Phase: A: Water B: Methanol Gradient: Time 0 8 10 20 25 %B 30 50 100 100 30 Column Temp: 40 C ELSD Replaces RI with Higher Sensitivity and Stable Baselines 1. Fructose 2. Glucose 3. Sucrose 10278 10277 Column: Prevail Carbohydrate ES, 5µm, 53 x 7mm Rocket (Part No. 35104) Mobile Phase: Acetonitrile:Water (75:25) Flow Rate: 2.0mL/min Column Temp: 30ºC 5

IDEAL FOR PHARMACEUTICAL AND NUTRACEUTICAL ANALYSIS Use ELSD In Parallel with UV/Vis and MS for Maximum Structural and Concentration Information 1. Aspartame 2. Hydrocortisone 3. Reserpine 4. Terfenadine 10456 10458 10457 Stable Baselines with Rapid, Extreme Gradients 10451 1. Ephedrine 2. Acetylsalicylic Acid 3. Diphenhydramine 4. Trimipramine Column: Alltima HP C18, 3µm, 33 x 7mm Rocket (Part No. 87671) Mobile Phase: A: 0.1% TFA in Water B: 0.1% TFA in Acetonitrile Gradient: Time: 0 3 %B: 10 90 Flow Rate: 2.5mL/min Column Temp: 30 C Use Gradient Elution and Detect Non-Chromophoric Nutraceuticals Ginkgo Biloba Standardized Extract Column: ZORBAX StableBond C18, 3.5µm, 50 x 4.6mm (Part No. 835975-902) Mobile Phase: A: 0.025% Formic Acid in Water B: 0.025% Formic Acid in Acetonitrile Gradient: Time: 0.0 1.0 5.0 5.1 %B: 25 70 70 25 Column Temp: 30 C Chromatograms courtesy of Agilent Technologies 0 1 2 3 4 5 5 10 15 20 25 30 35 Min. 1. Bilobalide 2. Ginkgolide J 3. Ginkgolide C 4. Ginkgolide A 5. Ginkgolide B 6. Quercetin 7. Kaempferol 8. Isorhamnetin Column: Alltima C18, 5µm, 250 x 4.6mm (Part No. 88056) Mobile Phase: A: 0.05% TFA in Water:Methanol (95:5) B: 0.05% TFA in Methanol Gradient: Time: 0 35 %B: 25 75 6 7 8 10241 6

VERSATILE DETECTION FOR A BROAD RANGE OF APPLICATIONS Use ELSD with Microbore Columns without Modifying the Detector Glucopyranosides 1. n-octyl Glucopyranoside (50ng on column) 2. n-decyl Glucopyranoside (50ng on column) 3. n-dodecyl Glucopyranoside (50ng on column) 10310 Column: Alltima C18, 3µm, 150 x 1mm (Part No. 43864) Mobile Phase: Methanol:Water (90:10) Flow Rate: 50µL/min Use ELSD for Triggering Fraction Collection of UV/Vis Transparent Compounds in Preparative Applications ELSD Simplifies Detection of Difficult Samples Ethinamate 10438 1. Ethinamate Mono-, Di-, Tri-Saccharides 1. iso-erythritol 2. Fructose 3. Sorbitol 4. Mannitol 5. Glucose 10009 6. Inositol 7. Sucrose 8. Maltitol 9. Maltose 10. Raffinose 11. Maltotriose 12. DP4 13. DP5 14. DP6 15. DP7 16. DP8 17. DP9 18. DP10 19. DP11 20. DP12 21. DP13 22. DP14 Column: Alltima C18, 5µm, 150 x 10mm (Part No. 81102) Mobile Phase: Water:Acetonitrile (55:45) Flow Rate: 5.0mL/min Column Temp: 25 C Column: Prevail Carbohydrate ES, 5µm, 250 x 4.6mm (Part No. 35101) Mobile Phase: A: Acetonitrile B: 0.04% Ammonium Hydroxide in Water Gradient: Time: 0 25 40 60 %B: 17 27 45 55 7

PRODUCT DETAILS AND SERVICES The ELSD 2000ES has been designed and manufactured in accordance with the following standards: EN6101-1 + A2:95, EN555011: 1998, FCC CFR 47 Part 15: 2001, EN 61326: 1998, EN 6100-3-2: 1995 + A14:2000 and EN61000-3-3: 1995 ELSD 2000ES* DESCRIPTION 120V 240V * Patent Pending PART NO. 600100ES 600200ES Full IQ/OQ/PQ Protocols Included With Each ELSD Alltech makes it easy for you to integrate the ELSD into a qualified HPLC system. The ELSD 2000ES is thoroughly tested before shipment and calibration and performance documents are included with each instrument. Detailed IQ/OQ/PQ procedures are included with the detector to help you perform your own qualification. We also provide the option of onsite qualification performed by an Alltech service engineer. Instrument Services DESCRIPTION Qualification Services IQ/OQ performed by Alltech PQ performed by Alltech IQ/OQ/PQ performed by Alltech Re-OQ performed by Alltech Re-OQ/PQ performed by Alltech Installation and Training Installation and familiarization PART NO. Q60010ES Q60020ES Q60030ES Q60040ES Q60050ES INSTALL Experience the benefits of increased sensitivity today! Call and ask for a quote or information on sample analysis or a product demonstration in your lab. The trademarks referred to herein are the property of their respective owners. Contact your Alltech office or distributor for current or local prices. Visit www.alltechweb.com for product information and online ordering. Visit www.chromatography.com for the latest in technical information and applications. Alltech Corporate Headquarters: 2051 Waukegan Road Deerfield, IL 60015 Phone: 847-948-8600 Fax: 847-948-0477 Email: alltech@alltechemail.com Web Site: http://www.alltechweb.com Your Local Source for Alltech Products: 06/04 #497 Copyright Alltech reserves the right to change prices and/or specifications without prior notification. Use of Our Products: Alltech Associates, Inc., supplies chromatographic equipment reagents and accessories for nonmedical laboratory use only. This means our products:... may NOT be used as drugs,...may NOT be used as cosmetics,...may NOT be used as medical devices or as in vitro diagnostic devices. Printed in the USA. Artisan Technology Group - Quality Instrumentation... Guaranteed (888) 88-SOURCE www.artisantg.com

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED LEASING/MONTHLY RENTALS ITAR CERTIFIED SECURE ASSET SOLUTIONS SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full-service, in-house repair center SM InstraView REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www.instraview.com Contact us: (888) 88-SOURCE sales@artisantg.com www.artisantg.com WE BUY USED EQUIPMENT Sell your excess, underutilized, and idle used equipment We also offer credit for buy-backs and trade-ins www.artisantg.com/webuyequipment LOOKING FOR MORE INFORMATION? Visit us on the web at www.artisantg.com for more information on price quotations, drivers, technical specifications, manuals, and documentation