INSTALLATION INSTRUCTIONS

7800 SERIES 22-Terminal Universal Subbase

7800 SERIES RM7888A Relay Module

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D 7800 SERIES Relay Modules

RM7838A 7800 SERIES Relay Modules

7800 SERIES EC7885A/RM7885A Relay Module

7800 SERIES RM7888A Relay Module

7800 SERIES EC7823/RM7823 Relay Module

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

7800 SERIES S7830 Expanded Annunciator

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

RM7897A,C 7800 SERIES Relay Modules

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

RM7895A,B,C,D/EC7895A,C; RM7896A,C,D 7800 SERIES

7800 SERIES S7800A2142 Keyboard Display Module

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

R7120M 7800 SERIES Relay Modules

CR Series Command Relays

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

RM7890A1056, RM7890B SERIES

Commercial/Industrial Combustion Control Level Three Announcement

Cleaver-Brooks CB780/CB784 Operation and Maintenance Manual

7800 SERIES S7800A1167 Keyboard Display Module

Honeywell SLATE ICM Platform

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

RM7890D; RM7895E,F 7800 SERIES Relay Modules

7800 Series RM7888A Relay Module

RM7890; RM Vac 7800 SERIES Relay Modules

C554A Cadmium Sulfide Flame Detector

Q7800H Integrated Burner Control Subpanel

7800 SERIES RM7840E,G,L,M Relay Module

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

YP7899C SERIES Burner Management Panel

T7079A,B Solid State Remote Temperature Controllers

APPLICATION SPECIFICATIONS INSTALLATION INSTRUCTIONS. The following assumptions apply when using the RM7840G,L, RM7800L, EC7840L:

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

7800 SERIES EC7810A, EC7820A Relay Module

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

IS Series Pressure Sensing Switches

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

MBCE-110/230FR Flame Sensor Module

7800 SERIES RM7824A Relay Module

T4398A,B Precision Electric Heating Thermostat

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

MBCE-110/230UV Flame Sensor Module

C7005A,B Gas Pilot and Flame Rod Assemblies

Model 17A00 Expansion Enclosure

MBCE-110/230FR Flame Sensor Module

Sensor Interface Module Installation/Operation Instructions

Room Sensor for BACnet VAV Actuator

GAS COOKTOP INSTALLATION INSTRUCTIONS

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

Installation and Maintenance Manual IM 1038

MBUV-100D, MBUVS-100D MBIR-100D, MBFR-100D DIN RAIL MOUNT FLAMEWORX MODULES

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

Booster Power Supply Manual

Field Start-Up Sheet Direct Fired Gas Equipment

SC-6 Six Supervised Control Module

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

SP-1000X. Panic Device Power Controller Installation Guide. Rev

C6097A,B Pressure Switches

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

Instructions For A and Flame Simulators

Sola Hydronic Control. An Eco-Friendly Solution.

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

P7810A-D Pressuretrol Controller

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

C7232A,B Sensor and Controller

/9308 External Battery Chargers Installation Instructions

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

RA889A Switching Relay

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Dual Input ph/orp Analyzer

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

Dual Input Toroidal Analyzer

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Flame Rod Manual. Publication Rev A

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

4100U City and Relay Cards Installation Instructions

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Transcription:

SLATE Sub-Base Module R8001S9001 INSTALLATION INSTRUCTIONS

Scan for more information

Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can easily be customized for almost any requirement or application offering virtually limitless development opportunities with far less complexity. The R8001S9001 SLATE Sub-Base Module provides the ability for the SLATE system to be mounted via DIN Rail in a panel. All SLATE modules need this sub-base except for the SLATE Base Module. Features Quick-mount to standard DIN-Rail Locking mechanism Provides bus connectivity to all modules Connections for remote mounted flame amplifiers (remote bus) and remote pushbutton reset Specifications Electrical Ratings: Voltage and Frequency (from the Base): 18 VDC (± 1 VDC) Maximum Total Connected Load: 2.5A Terminal Ratings: See Table 1 Terminal Description Rating 1 18 V Power 2.5 A max including modules 2 18 V Ground --- 3 Remote Reset (Burner Control and Limit modules only) Connect to Terminal 2 (18 V Ground) via external pushbutton SLATE Sub-Base Module 3 R8001S9001

Terminal Description Rating 4 B (Remote Bus RS485) 5 A (Remote Bus RS485) Table 1. Terminal Ratings. Used for Remote mounted flame amplifiers Used for Remote mounted flame amplifiers Environmental Ratings Ambient Temperature: Operating: -20 F to +150 F (-29 C to +66 C). Shipping: -40 F to +150 F (-40 C to +66 C) Humidity: 95% continuous, noncondensing. Vibration: 0.5G environment Dimensions: See Fig. 1. Weight: 5 oz (136 g) Approvals Underwriters Laboratories Inc. Listed, File: MP286 IRI acceptable. Federal Communications Commission: Part 15, Class A Emissions. Mounting DIN Rail (See Fig. 3) Required Components R8001A1001 SLATE Base Module Any other SLATE modules Optional 5-position terminal block for remote flame amplifier or remote reset button connections (Phoenix Contact p/n 1754504 or equivalent). See Fig. 2. 4 32-00025 01

7-3/32 (180) 1-5/32 (29) 2-21/32 (67) 3-13/32 (86) M35384 Fig. 1. Dimensions in in. (mm). SLATE Sub-Base Module 5 R8001S9001

1 2 3 4 5 TERMINAL DESCRIPTION 1 18V POWER 2 18V GROUND 3 REMOTE RESET (BURNER CONTROL AND LIMIT MODULES ONLY) 4 B (REMOTE BUS RS485) 5 A (REMOTE BUS RS485) Fig. 2. Sub-base module wiring terminals. M35430 6 32-00025 01

Installation WARNING Fire or Explosion Hazard Can cause severe injury, death, or property damage. Verification of safety requirements must be performed each time a control is installed on a burner to prevent possible hazardous burner operation. When Installing This Product 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. Mounting 1. The sub-base module can be mounted on type C 20 DIN rail. 2. Mount the sub-base module first. The sub-base has locking mechanisms on both sides of the module. Pull to unlock position. See Fig. 3. SLATE Sub-Base Module 7 R8001S9001

UNLOCKED FROM DIN RAIL LOCKED ONTO DIN RAIL Fig. 3. Sub-base locking mechanisms. M35378 3. Slide sub-base on the DIN rail and lock into place. 4. When securing subsequent sub-base modules make sure communication ports are aligned and locked into place. See Fig. 4. M35386 Fig. 4. Connecting additional sub-base modules. 8 32-00025 01

5. After securing the sub-base module, snap the SLATE module into place and secure the module to the sub-base using screws (included with SLATE module). Wiring WARNING Electrical Shock Hazard. Can cause severe injury, death or equipment damage. 1. Disconnect the power supply before beginning installation to prevent electrical shock and equipment damage. More than one power supply disconnect can be involved. 2. Wiring must comply with all applicable codes, ordinances and regulations. See Fig. 2. 3. Wiring must comply with NEC Class 1 (Line Voltage) wiring. Application Communication Lines Other terminals Recommended Wire Size 22 AWG two-wire twisted pair with ground, or five-wire. 18 AWG wire insulated for voltages and temperatures for given application. Recommended Part Numbers Belden 8723 shielded cable or equivalent. TTW60C, THW75C, THHN90C Table 2. Recommended Wire Sizes and Part Numbers. IMPORTANT This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause interference for radio communications. It has been tested and found to comply with the limits of a Class A computing device of part 15 of FCC rules, which are designed to provide reasonable protection against such interference SLATE Sub-Base Module 9 R8001S9001

when operated in a commercial environment. Operation of this equipment in a residential area may cause interference; in which case, the user, at their own expense, may be required to take whatever measures are required to correct this interference. 1. This digital apparatus does not exceed the Class A limits for radio noise, set out in the Radio Interfeence Regulations of the Canadian Department of Communications. 2. Cable shield must be terminated to ground at both ends. If shielded cable is NOT used, use three-wire twisted cable. Recommended Grounding Practices Use an Earth ground or a signal ground as described below. Earth Ground (Base, Rectification Flame Amp Module, Other Modules Optional) 1. Use to provide a connection between the base and the control panel of the equipment. Earth ground must be capable of conducting enough current to blow the breaker in the event of an internal short circuit. 2. Use wide straps or brackets to provide minimum length, maximum surface area ground conductors. If a leadwire is required, use 14 AWG copper wire. 3. Verify that mechanically tightened joints along the ground path are free of nonconductive coatings and protected against corrosion on mating surfaces. Signal ground Note the 18 V system ground is not electrically connected to earth ground. Follow local codes and appliance recommendations to determine if this should be connected to earth ground. Recommended Routing of Leadwires Do not run high voltage ignition transformer wires in the same conduit with the flame detector or data lines. Do not route flame detector or data lines in conduit with line voltage circuits. 10 32-00025 01

Enclose flame detector leadwires without armor cable in metal cable or conduit. Follow directions in flame detector instructions. Be sure loads do not exceed the terminal ratings. Refer to the labels or terminal ratings in Table 1. The SLATE system must be mounted in an electrical enclosure. When mounting in an electrical enclosure, provide adequate clearance for servicing, installation, and removal of SLATE modules. Maximum Wire Length The maximum leadwire length is 300 feet to terminal inputs (Control, Running/Lockout Interlock) For remote reset leadwires, maximum length to remote pushbutton is 1000 feet. For remote bus data lines, maximum cable length depends on the number of modules connected, the noise conditions, and the cable used. The maximum of all interconnecting wires is 4000 feet. SLATE Sub-Base Module 11 R8001S9001

32-00025-01 For more information and detailed instructions on the SLATE display please refer to the SLATE User Guide document located on our website at http://combustion.honeywell.com/slate Automation and Control Solutions Honeywell International Inc. U.S. Registered Trademark. 1985 Douglas Drive North 2014 Honeywell International Inc. Golden Valley, MN 55422 32-00025 01 M.S. 11-14 customer.honeywell.com Printed in U.S.A.