Refrigerants and lubricants

Similar documents
Maneurop reciprocating compressors

Maneurop reciprocating compressors. MT/MTZ Hz - R22 - R407C - R134a - R404A / R507A MAKING MODERN LIVING POSSIBLE

Maneurop reciprocating compressors MT / MTZ

Maneurop reciprocating compressors MT/MTZ

Maneurop reciprocating compressors MT / MTZ

Maneurop reciprocating compressors MT/MTZ

Maneurop reciprocating compressors MT / MTZ

Maneurop reciprocating compressors MT/MTZ

Refrigerant Glide and Effect on Performances Declaration

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Chapter 2. Alternatives to HCFCs and their Characteristics

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Scroll Chillers Transition from HCFC-22 to HFCs

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Performer scroll compressors. SM - SY - SZ Hz R22 - R407C - R134a - R404A - R507A. Selection & application guidelines

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

March 10, 2016 San Joaquin Valley RETA Meeting

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

TERNARY ZEOTROPIC MIXTURE WITH CO 2 COMPONENT FOR R-22 HEAT PUMP APPLICATION

Danfoss scroll compressors SM SY SZ

Retrofit and High Glide Refrigerants

CHAPTER 1 INTRODUCTION

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Danfoss scroll compressors SM - SY - SZ

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Danfoss scroll for refrigeration LLZ013 to low temperature

MAKING MODERN LIVING POSSIBLE. MLZ / MLM Refrigeration scroll compressors Hz - R404A - R507 - R134a - R22. Selection & application guidelines

Maneurop reciprocating compressors NTZ

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Gary Parker Refrigerants Product Manager

Gary Parker Refrigerants Product Manager

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Maneurop reciprocating compressors

A Comparison Between Refrigerants Used In Air Conditioning

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Check valve Types NRV and NRVH

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Danfoss scroll compressors SH090 to SH485 - single

The natural solution for domestic refrigeration

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Danfoss scroll compressors SH090 to SH485 - single

The Refrigeration Cycle

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

RS-45 (R-434A) R22 REPLACEMENT AT ALL TEMPERATURES. U.S. EPA Certified NON-FLAMMABLE

International Journal of Advance Engineering and Research Development

The Refrigeration Cycle

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

REFRIGERANT CHANGEOVER

Study of R161 Refrigerant for Residential Airconditioning

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

Evaluation of HCFC Alternative Refrigerants

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Danfoss scroll compressors CXH140 - single and manifold installation

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

Pressure Enthalpy Charts

Filter Driers with Replaceable Core

10/4/2013. The Changing State of Refrigerants

APPLICATION & SERVICE GUIDE

The Essentials Of Working With R-410A

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Danfoss scroll compressors In parallel installation SM/SY/SZ

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

R-407A R-448A R-449A

Low GWP Refrigerants for Air Conditioning Applications

HCFC-22 replacement with drop-in and retrofit HFC refrigerants in a two-stage refrigeration plant for low temperature

Kirby Commander Condensing Unit

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

DEEPAK PALIWAL, S.P.S.RAJPUT

Air-Cooled Heat Exchanger Performance for R410A

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Performance Assessment of Three Eco-Friendly Hydro-Fluorocarbon and Hydrocarbon Refrigerant Mixtures as R22 Alternatives in Refrigeration Systems

REFRIGERANT REPORT 20 A EN

Heat Pump/Air Conditioner Field Test Data for an HCFC-22 Alternative Containing HFC-32, HFC-125, and HFC-134a

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Modeling and Testing of an R-23/R-134a Mixed Refrigerant System for Low Temperature Refrigeration

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Framtidens köldmedier

Reduce everything but reliability

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Maneurop reciprocating compressors NTZ

A study on retrofit methodologies for legacy air-conditioning systems to reduce their impact on global warming and ozone depletion

Tube-in-tube heat exchanger Type HE

Transcription:

Refrigerants and lubricants GENERAL INFORMATION When choosing a refrigerant, different aspects must be taken into consideration: Legislation (now and in the future) Safety Application envelope in relation to expected running conditions. Compressor capacity and efficiency Compressor manufacturer recommendations & guidelines Additional points could influence the final choice: Environmental considerations Standardisation of refrigerants and lubricants Refrigerant cost Refrigerant availability The table below gives an overview of the different refrigerant-lubricantcompressor combinations for Maneurop MT & MTZ compressors. Lubricant Compressor Refrigerant Type type type Danfoss Maneurop lubricant Application R22 HCFC Mineral MT White oil, 1P Medium / High Temperature R7C HFC Polyolester MTZ Polyolester oil 1PZ Medium / High temperature R134a HFC Polyolester MTZ Polyolester oil 1PZ Medium / High temperature R4A HFC Polyolester MTZ Polyolester oil 1PZ Medium temperature R7 HFC Polyolester MTZ Polyolester oil 1PZ Medium temperature Transitional refrigerants, R22 based Hydrocarbons Alkylbenzene Alkylbenzene oil 1 ABM MT Note: Initial mineral oil charge has to be Medium / High temperature (ABM) replaced by 1 ABM oil. Danfoss Maneurop does not authorise the use of hydrocarbons in their compressors The Montreal protocol states that CFC refrigerants such as R12 and R2 may no longer be applied in new installations in the signatory members countries. Therefore capacity and other data for these refrigerants are not published in this document. Danfoss Maneurop MT compressors however are suitable for use with these refrigerants and can still be used as replacements in existing installations. R22 R22 is an HCFC refrigerant and is still a wide use today. It has a low ODP (Ozone Depletion Potential) and therefore will be phased out in the future. Check local legislation. Always use Maneurop White oil. The Maneurop MT compressor is dedicated for R22 and is supplied with an initial mineral oil charge. Use the application envelopes on page 8 and performance tables on page 10-11 to select the correct compressor. R7C Refrigerant R7C is an HFC refrigerant with similar thermodynamic properties to those of R22. R7C has zero ozone depletion potential (ODP=0). Many installers and OEMs consider R7C to be the standard alternative for R22. R7C is a zeotropic mixture and has a temperature glide of about 6 K. For more specific information about zeotropic refrigerants; refer to section "zeotropic refrigerant mixtures". R7C must be charged in the liquid phase. Always use the Maneurop MTZ compressors with Danfoss Maneurop 1PZ polyolester oil, which is supplied with the MTZ compressor for R7C applications. Use the application envelope on page 8 and performance tables on page 12-13 to select the correct compressor. Maneurop MT compressors should never be used with R7C, even when the mineral oil is replaced with polyolester oil. Hz catalogue 1

Specifications TECHNICAL SPECIFICATIONS Compressor model Displacement Cyl. Oil Net Design versions** number charge weight motor voltage code (cm 3 /rev) (m 3 /h)* (dm 3 ) (kg) 1 3 4 5 6 7 9 MT / MTZ 18 JA.23 5.26 1 0.95 21 S-VE S-VE S-VE S-VE - - - MT / MTZ 22 JC 38.12 6.63 1 0.95 21 S-VE S-VE S-VE S-VE S-VE - - MT / MTZ 28 JE 48.06 8.36 1 0.95 23 S-VE S-VE S-VE S-VE S-VE - - MT / MTZ 32 JF 53.86 9.37 1 0.95 24 S-VE S-VE S-VE S-VE S-VE S-VE S-VE MT / MTZ 36 JG.47 10.52 1 0.95 25 S-VE S-VE S-VE S-VE S-VE - - MT / MTZ JH 67.89 11.81 1 0.95 26 S-VE S-VE S-VE - S-VE - - MT / MTZ 44 HJ 76.22 13.26 2 1.8 S-VE S-VE S-VE - S-VE - - MT / MTZ HJ 76.22 13.26 2 1.8 37 S-VE S-VE S-VE - - - - MT / MTZ HK 85.64 14.90 2 1.8 S-VE S-VE S-VE - S-VE S-VE S-VE MT / MTZ 51 HK 85.64 14.90 2 1.8 37 S-VE S-VE S-VE - S-VE - - MT / MTZ 56 HL 96.13 16.73 2 1.8 37 S-VE S-VE S-VE - S-VE S-VE S-VE MT / MTZ 57 HL 96.13 16.73 2 1.8 39 S-VE S-VE S-VE - - - - MT / MTZ 64 HM 107.71 18.74 2 1.8 37 S-VE S-VE S-VE - S-VE - S-VE MT / MTZ HM 107.71 18.74 2 1.8 39 S-VE S-VE S-VE - S-VE - - MT / MTZ 72 HN 120.94 21.04 2 1.8 - S-VE S-VE - S-VE - S-VE MT / MTZ 73 HN 120.94 21.04 2 1.8 41 - S-VE S-VE - S-VE - - MT / MTZ 80 HP 1.78 23.63 2 1.8 - S-VE S-VE - S-VE - S-VE MT / MTZ 81 HP 1.78 23.63 2 1.8 41 - S-VE S-VE - - - - MT / MTZ 100 HS 171.26 29.80 4 3.9 - S-VE S-VE - S-VE S-VE S-VE MT / MTZ 125 HU 215.44 37.49 4 3.9 64 - S-VE S-VE - S-VE S-VE S-VE MT / MTZ 144 HV 241.87 42.09 4 3.9 67 - S-VE S-VE - S-VE S-VE S-VE MT / MTZ 1 HW 271. 47.25 4 3.9 69 - S-VE S-VE - S-VE S-VE S-VE MT / MTZ 200 HSS 342.52 2 x 29.80 8 10.4 1 - S S - S - - MT / MTZ 2 HUU 4.88 2 x 37.49 8 10.4 175 - S S - S - - MT / MTZ 288 HVV 483.74 2 x 42.09 8 10.4 178 - S S - - - - MT / MTZ 320 HWW 543.10 2 x 47.25 8 10.4 180 - S S - S - - * At 2900 rpm ** S & VE versions, see table on page 4. 2 Hz catalogue RECIPROCATING COMPRESSORS

Specifications NOMINAL PERFORMANCE R22, R7C - HZ Compressor model NOMINAL RATINGS * NOMINAL RATINGS ** MT - R22 MTZ - R7C Cooling Power Current COP Cooling Power Current COP capacity input input capacity input input (W) (kw) (A) (W/W) (W) (kw) (A) (W/W) MT / MTZ 18 JA 3881 1. 2.73 2.68 3726 1.39 2.47 2.68 MT / MTZ 22 JC 5363 1.89 3.31 2.84 4777 1.81 3.31 2.64 MT / MTZ 28 JE 7378 2. 4.56 2.89 6137 2. 4.39 2.61 MT / MTZ 32 JF 8064 2.98 4.97 2. 6941 2.67 5.03 2. MT / MTZ 36 JG 9272 3.37 5.77 2.75 7994 3.12 5.71 2.56 MT / MTZ JH 10475 3.85 6.47 2.72 9128 3.61 6. 2.53 MT / MTZ 44 HJ 11037 3.89 7.37 2.84 9867 3.63 6.49 2.72 MT / MTZ HK 12324 4.32 8.46 2.85 11266 4.11 7.34 2.74 MT / MTZ 56 HL 13771 5.04 10.27 2.73 12944 4.69 8.36 2.76 MT / MTZ 64 HM 15820 5.66 9.54 2.79 187 5.25 9. 2.78 MT / MTZ 72 HN 17124 6.31 10.54 2.71 16380 5.97 10.48 2.74 MT / MTZ 80 HP 19534 7.13 11.58 2.74 18525 6.83 11.83 2.71 MT / MTZ 100 HS 233 7.98 14.59 2.93 22111 7.85 13.58 2.82 MT / MTZ 125 HU 429 10.66 17.37 2.85 29212 10.15 16.00 2.88 MT / MTZ 144 HV 343 11.95 22.75 2.87 32934 11.57 18.46 2.85 MT / MTZ 1 HW 38273 13.39 22.16 2.86 37386 13.28 21. 2.82 MT / MTZ 200 HSS 46807 15.97 29.19 2.93 43780 15.54 26.90 2.82 MT / MTZ 2 HUU 858 21.33 34.75 2.85 57839 20.09 31.69 2.88 MT / MTZ 288 HVV 68379 23.91. 2.87 225 22.92 36.56 2.85 MT / MTZ 320 HWW 747 26.79 44.32 2.86 724 26. 42.37 2.81 NOMINAL RATINGS* MT HIGH EFFICIENCY COMPRESSORS R22 - HZ Compressor Cooling capacity (W) Power input (kw) Current input (A) COP (W/W) MT HJ 10786 3.62 6.86 2.98 MT 51 HK 120 4.01 7.86 3.07 MT 57 HL 13711 4.54 9.24 3.02 MT HM 15763 5.23 8.81 3.01 MT 73 HN 17863 5.98 9.99 2.99 MT 81 HP 20298 6.94 11.27 2.93 * Ratings at ARI conditions with R22: 7.2 C evaporating temperature, 54.4 C condensing temperature, 8.3 K subcooling, 11.1 K superheat, Hz, 0 V. ** Ratings at ARI conditions with R7C at dew point: 7.2 C evaporating temperature, 54.4 C condensing temperature, 8.3 K subcooling, 11.1 K superheat, Hz, 0 V. Capacity and power input data ± 5%. Hz catalogue 3

Operating envelopes - -25-20 -15-10 -5 0 5 10 15 20 for MT compressors with R22 - -25-20 -15-10 -5 0 5 10 15 20 R7C at DEW POINT 80 75-20 -15-10 -5 0 5 10 15 20 25 R134a - - -25-20 -15-10 -5 0 5 10 15 R4A/R7 Hz catalogue 4

Operating envelopes ZEOTROPIC REFRIGERANT MIXTURES Refrigerant mixtures can be either zeotropic or azeotropic. An azeotropic mixture (like R2 or R7) behaves like a pure refrigerant. During a phase transition (from vapour to liquid or from liquid to vapour) the composition of vapour and liquid stays the same. In a zeotropic mixture (like R7C) on the other hand the composition of vapour and liquid changes during the phase transition. When the effect of this phase transition is very small, the mixture is often called a near-azeotropic mixture. R4A is such a near-azeotropic mixture. The composition change has two resulting effects: Phase shift In system components where both vapour and liquid phase are present (evaporator, condenser, liquid receiver), the liquid phase and vapour phase do not have the same composition. In fact both phases form two different refrigerants. Therefore zeotropic refrigerants need some special attention. Zeotropic refrigerants must always be charged in liquid phase. Flooded evaporators and suction accumulators should not be applied in systems with zeotropic refrigerants. This also applies to near-azeotropic mixtures. Temperature glide During the evaporating process and the condensing process at constant pressure, the refrigerant temperature will decrease in the condenser and rise in the evaporator.therefore when speaking about evaporating and condensing temperatures, it is important to indicate whether this is a DEW point temperature or a MEAN point value. In the figure below, the dotted lines are lines of constant temperature. They do not correspond to the lines of constant pressure. Points A and B are DEW point values.these are temperatures on the saturated vapour line. Points C and D are MEAN point values.these are temperatures which correspond more or less with the average temperature during the evaporating and condensing process. For the same R7C cycle, MEAN point temperatures are typically about 2 to 3 C lower than DEW point temperatures. According to Asercom recommendations, Danfoss Maneurop uses DEW point temperatures for selection tables and application envelopes etc. To obtain exact capacity data at mean point temperatures, the mean point temperatures must be converted to dew point temperatures with help of refrigerant data tables from the refrigerant manufacturer. pressure (log) D B DEW temperature and MEAN temperature for R7C C A enthalpy 5 Hz catalogue RECIPROCATING COMPRESSORS