Technical Specification

Similar documents
Technical Specification VFD

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

PILOT VALVE ENCLOSURES

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Platen Heater Pad Replacement

ACT Cartridge Dust Collector

TEMPERATURE CONTROLLERS

PARTS CATALOGUE 2011

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Vickers. Service Data. Piston Pumps. PVH57/63 Variable Displacement Piston Pump - 11 Design M-2206-S. Revised 11/01/97

569, 570, 571, 572 Series

Liquid Drainers LIQUID DRAINERS

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Genie Heated Regulator Installation & Operation Instructions

Pop-up Clicker Drain Installation and User Guide

Service Data Vickers. Piston Pumps. PVH98/106 Variable Displacement Piston Pump - 11 Design M-2208-S. Revised 05/01/97

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

PF Series. Piston Actuated Valves

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

TANKER & STORAGE TANK PRODUCTS

569, 570, 571, 572 Series

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

Service Data Vickers. Piston Pumps. PVH74/81 Variable Displacement Piston Pump - 11 Design M-2207-S. Revised 11/01/97

Condensate Drain Valves

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Filter cleaning in hot gas applications PENTAIR 1

Worldwide Contacts.

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Ar-Mite TM Low Flow Armored Flowmeter

Worldwide Contacts. Technical Data

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

610 AC3 CONTROL KNOB (OFF, PILOT, ON) TEMPERATURE SELECTION KNOB ON-OFF REGULATING THERMOSTAT THERMOELECTRIC SAFETY DEVICE.

Technical Data. Sizes 2 12 Inch (DN50 DN300)

Darchem Thermal Protection

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Heater Core And Evaporator Core Housing

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

3500 CFM TECHNICAL SPECIFICATIONS MIDWEST VACUPAC BIN VENT AND CONVEYOR TRANSFER POINT DUST CONTROL SYSTEM SERIES MBV 43 F MBV 43 C MBV 37 C MBV 54 F

Canadian Retail. Parts Catalogue

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

WHY CHOOSE AN EXTREME DUTY MULTI VAC INDUSTRIAL VACUUM SYSTEM?

MJC cartridge dust collector

Canadian Retail. Parts Catalogue

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

MJC Mini. Cartridge Filter. Features. Principal specification and options

INSTALLATION INSTRUCTIONS M SHOWER SLIDING RAIL

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Basket Blasters. BB2-3K & BB4-3K Models BB2-3K & BB4-3K Options BB4-3K Basket Blasters

Rapide Gas Boilers BRG 80 BRG 120 BRG 200

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

SmartLine Pressure Transmitter ST 700 Basic Quick Start Installation Guide 34-ST-25-57, Revision 1, December 2016

irritec USA irritec USA THE MODULAR SAND MEDIA FILTER TM Water Tool Filters

CERAMIC COOKTOP MODELS CE901 AND CE901M

Installation, commissioning and servicing instructions

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

FMC(Z) cartridge filter

GV Series 4 Section Assembly

MINIATURE THERMOSTATIC VALVE

Air operated diaphragm pumps. Catalogue 2011 rev 1

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

MemoirsStately3HoleBasin Mixer Installation and User Guide

Eco IR Basin Tap. Installation and Maintenance Guide. A basin mounted tap with pre-programmed infra-red sensor; mains or battery supply.

Taco 00 Series Cartridge Circulators

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Thermostatic Control Valves

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

OEM Sensors for HVAC manufacturers Heat recovery Chiller

High Pressure Water - Descale Valves - VXXX Series. Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

INSTALLTION FOR THERMOSTATIC VALVES

Page 1 of 18. Part# /5/2013

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

M7100 Pressure Transducer

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Cartridge Heaters. Components. Application Guidelines

V46. Pressure actuated water valves. Refrigeration components Modulating water valves. Catalogue page

568X, 587X, 588X Series

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Transcription:

Technical Specification 3 Series Pulse Jet Valves FS3 Series T3 Series DD3 Series Description Superior performance, easy maintenance diaphragm valve available with threaded ports (T3), dresser nut ports (DD3) or flange and slide ports (FS3). Outlet at 90 to inlet. 3 Series valves are available as remote pilot valves and may be converted to integral pilot applications through the use of the screw in pilots of the MIP and 3DS series. Suitable for Dust collector applications, in particular for reverse pulse jet filter cleaning and its variations including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters. Construction Body: Aluminium (diecast) Seals: Nitrile or Viton (diaphragms reinforced) Spring: 304 SS Diaphragm Seat: PA-6 (standard), Viton coated mild steel Operation Recommended on time range: 50-500ms Recommended time between pulses: 1 minute or greater Maintenance Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually. Approvals Atex II 2D Mechanical (RCA Only) CSA (US) C22.2 No 139-1982, UL 429 (CA & RCA) Installation For your safety do not pressurise system until all valves and pipes are fully secured. Do not attempt to remove a fitted valve while system is under pressure. 1. Prepare supply and blowtube pipes* to suit valve type and specification. Avoid installing valves underneath the tank. 2. Ensure tank and pipes are free from dirt, rust or other particulate. 3. Ensure supply air is clean and dry. 4. Mount valves to inlet pipes (or flanges, tighten bolts to 10Nm) and blowtube to valves, ensuring no excess thread sealant can enter the valve itself. Ensure blowtube is fully inserted into the valve outlet. 5. Tanks and pipes must be independently restrained from FS and DD valves. 6. Connect RCAC pilot port to remote pilot valve, or install MIP/3DS screw in pilot valve. 7. Apply moderate pressure to system and check for installation leaks. 8. Fully pressurise system. 9. Test fire and listen for proper actuation and crisp pulse noise. Valve is not a structural component. Do not rely on valve to retain tanks or pipe. Refer to Camlock product specifications for installation details. *Pipes must be to Schedule 40 outside diameter Schedule 40 Size OD mm OD Inches ¾" 26.7 1.050 1" 33.4 1.315 Weights Size Remote Pilot (RCAC) Size Remote Pilot (RCAC) Kg (lbs) Kg (lbs) 20T3 0.55 (1.21) 25T3 0.65 (1.43) 20ST3 0.55 (1.21) 25DD3 1.05 (2.32) 20DD3 0.55 (1.21) 25FS3 0.95 (2.08) 20FS3 0.55 (1.21) Maintenance Kits and Accessories Model Nitrile Viton Includes RCAC20T3, ST3, DD3, FS3 K2016 K2017 Diaphragm kits include main RCAC25T3, DD3, FS3, FH3 K2529 K2530 diaphragm, spring, and locking pin. 20DD3 Dresser nut seal kit K2018 K2019 Nut, seal, and seal retaining ring. 25DD3 Dresser nut seal kit K2533 K2534 Nut, seal, and seal retaining ring. 20FS3 Outlet seal replacement G690338 G690338-2 Outlet seal 25FS3 Outlet seal replacement G690763 G690763-2 Outlet seal 25FS3 Valve to baghouse wall seal G690125 G690125-2 Wall seal Camlock for 20 & 25FS3 and 6" round tank K2514-2 - Flange adaptor to mount FS Camlock for 20 & 25FS3 valves to round tanks. and 8" round tank K2536-2 - Eliminates welding. Refer to Camlock product specification. 2 Copyright by Tyco International Ltd. TS 3 Series 11/11

Product Characteristics and Performance Model Port Size Number of Flow Pressure Range Temperature Range C (F) mm in diaphragms Kv Cv kpa(psi) Nitrile Seals Viton Seals 20T3 20 ¾" 1 14 17 30(5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 20ST3 20 ¾" 1 14 17 30(5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 20DD3 20 ¾" 1 14 17 30(5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 20FS3 20 ¾" 1 19 22 30(5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 25T3 25 1" 1 24 27 30(5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 25DD3 25 1" 1 24 27 30(5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 25FS3 25 1" 1 34 40 30(5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) Order Code RCAC 0 Diaphragm material 0=nitrile, 1=viton Thread type 0=NPT, 1=RC, 2=G Pilot size 0=1/ 8 1=1/4 Connection style Valve port size T3=Threaded, ST3=Short Threaded*, DD3=Dresser Nut, FS3=Flange in/slide out FH3=Flange inlet/hose outlet** 20, 25 mm *Available for 20 (3/4") size only. **Available for 25 (1") size only. Examples: RCAC25T3010 1" threaded port valve with 1/8" pilot, 1" RC port threads, nitrile seals. RCAC20FS3001 3/4" flange inlet slide seal outlet port valve with 1/8" NPT remote pilot port and viton seals. Dimensions (Dimensions in mm and [inches]) RCAC20T3 Copyright by Tyco International Ltd. TS 3 Series 11/11 3

RCAC20ST3 RCAC20DD3 4 Copyright by Tyco International Ltd. TS 3 Series 11/11

RCAC20FS3 RCAC25T3 Copyright by Tyco International Ltd. TS 3 Series 11/11 5

RCAC25DD3 RCAC25FS3 6 Copyright by Tyco International Ltd. TS 3 Series 11/11