Manual SLM50HE.

Similar documents
Buffer Tank FWSS 1000 V7-RH

Domestic Hot Water Tank

Fresh Water Station FWS 20 / FWS 30. Manual. Masterpieces. Art.-Nr.: (V1.0) of Solar Technology

CIRCO 6 Solar Circulation Unit

Installation and instruction manual SOLAR STATION

OptiSorp. Steam distribution system EN 1112

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Solar station DKP 6-8 / DKP Installation and Service Manual C

Installation instructions

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

Lifting Station Type ABS Sanimax

OWNER S MANUAL. Solar Collector DELUXE

ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01

Friwa Compact. Operating instructions EN

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Installation, operating and servicing instructions

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

SHOWER SOFTENER-CEASA 1

20 TON AIR/MANUAL SHOP PRESS

Operating Instructions!

Operating Instructions

TT /97 WARNING WARNING WARNING INSTALLATION INSTRUCTIONS

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Model: 1100 Float-Controlled Condensate Trap, PN 25

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Operating Instructions

USER S MANUAL ATH WH220

Grain crusher Universal. Purpose: This machine is designed for the crushing of grain in agricultural operation.

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

USER S GUIDE WATER HEATED AIR CURTAINS

Technical information for installation and operation

INSTRUCTIONS MANUAL INDUSTRIAL WALL FAN (20, 26, 30 ) WITH REMOTE CONTROL

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Engine Block Heater Service Kits (Tank Type) 30RZ/33RZ/45RZ (CSG 649 Ford Powered) Standby Generator Sets

BOILING PANS GAS & ELECTRICS

FLOW HEATER 32E X 2R IMPORTANT GENERAL INFORMATION: SPECIFICATION. Instruction Manual. Article number: 045a-105 Electric heating capacity:

Pump assembly Instruction manual

USER GUIDE ENGLISH TOPSTART Ref. TSWZ, TSWRS or TSG Between 0.5 and 3 kw

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

The Meibes concept for the specialist: Easier. Quicker. More successful.

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Miniboil Boiling Only

Installation guide PRO7-VAQ E. Before installing read this guide first

Pole Mounting System Installation & Certification Manual

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

Instructions for installation and use English. More documents on: H B /09

OWNER S MANUAL IMPORTANT: READ OWNER S MANUAL CAREFULLY

15,000 BTU Portable Air Conditioner

Gema Canopy. Floated ceiling easy installed

Installation and operating instructions. DK energy storage and DK energy buffer

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Granule Gastro/Combi

HOT WASHER MODEL NO: KING150

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Commissioning a Solar Thermal Installation

Water level controller and limiter

ENGLISH USER S GUIDE ThermoCar from 0,5 to 2 kw

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

Regulux. Radiator lockshield with drain-off facility. To be precise.

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Installation Operation Maintenance

Control valves for floor heating systems. Floor Heating Manifolds

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Mira Sport Max with Airboost

Original instructions Sense7-series Non-contact coded safety switch

SCHWAN INSTALLATION GUIDE

Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless.

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

Installation guide VAQ E. Before installing read this guide first

SPLIT WALL-MOUNTED AIR CONDITIONER

HKF 8180 Operating instructions

Moisture inside the drum is due to final testing.

Operating instructions

infranomic INFRARED HEATING PANELS Operating and Installation Instructions Wolff+Meier GmbH & Co. KG Glaswerke Am Wingert Langgöns Germany

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

User Guide Topax Hygiene System. S Booster MP44/MP66/MP88

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic

Decentralised ventilation units

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

Pro-Clean Stratified Tank scope of delivery:

TTV 4500 / TTV 4500 HP / TTV 7000

Installation Instructions

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Transcription:

Manual SLM50HE www.sonnenkraft.com www.sonnenkraft.com

Table of Contents 1. General 3 1.1. Use 3 1.2. Application example 3 2. Description 4 3. Warning 4 4. Structure of the shift layer module 4 5. Safety Instructions 5 6. Installation and Commissioning 6 6.1. Installation 6 6.2. Hydraulic connection 10 6.3. Electrical connections 10 6.4. Commissioning 11 7. Technical Data 14 7.1. Construction 15 8. Spare parts 16 9. Warranty 16 2

1. General Before commissioning your new shift layer module, please read all chapters thoroughly and, in particular, please note the warnings given in chapter 3. Incorrect handling can result in damage to the installation. 1.1. Use The SLM50HE layer loading station makes it possible to load the buffer tank depending on the temperature. Solar layer loading is speed regulated, energy efficient and suitable for large buffer tanks. 1.2. Application example 3

2. Description Shift layer module SLM50HE is used to connect a solar collector plant up to 50 m² in size to a buffer tank. The solar heat from the collector system is transfered to the buffer system with highly-efficient heat exchangers. Thereby, it provides an intelligent control system dependent on sunlight for optimum interaction between the solar and buffer loading pump and guarantees high heat transfer capacity. The module loads the buffer using speed control and the corresponding temperature zone of the buffer depending on the temperature. 3. Warning Installation and operation should be executed in accordance with the locally applicable specifications and standard practices. Only qualified technical personnel should carry out the assembly, maintenance and cleaning of the shift layer module. Unauthorised modifications or changes are not permitted for safety reasons and will inevitably lead to the voiding of the warranty for the machine. The operating pressures provided may not be exceeded! If any errors occur no matter of what type please contact your heating system installer. Please do not carry out any repairs to the plant yourself, since these are not permitted by law and you can expose yourself to hazards as a result. 4. Structure of the shift layer module Due to technical advancements, we reserve the right to make constructional changes on our products. Each of these changes are taken into account in the operating manual by replacing the respective pages. The module may sometimes vary from the appearance given in the illustration! 4

5. Safety Instructions The station is to be connected paying attention to the following norms, countryspecific guidelines and local water company regulations. DIN EN 12828 VDE 0100 Heating systems in buildings Setting up electrical operating equipment DIN 1988 VDE 0185 Technical rules for drinking water General notes for setting up supply installation lightning protection systems DIN 4708 VDE 0190 Central warm water heating system Main potential equalisation of electrical systems DIN 4751 Heating system safety equipment DIN 4753 Water heater and water heating system for drinking supply and industrial water DIN 4757 Solar heating and solar-thermal systems DIN 18380 Central heating systems and service water systems DIN 18381 Gas, water and waste water installation work DIN 18382 Electrical cable and wiring systems in buildings DIN EN 12975 Thermal solar systems and their components This appliance is not intended for use by persons (including children) with limited physical, sensory or mental abilities or with a lack of experience and/or knowledge, unless they are being supervised by a person who is responsible for their safety, or have received instructions from such a person as regards its use. If the power supply cable of this device is damaged, then this must be replaced by the manufacturer or their customer service or similarly qualified technicians, in order to prevent hazards. 5

6. Installation and Commissioning Before you start installation, please keep the following in mind: Read through the entire operating manual and pay particular attention to the section Warnings. This device is not intended for operation by people (including children) with limited physical, age or mental abilities. Uninformed or inexperienced persons are permitted to operate the machine only under the supervision or instruction of a person responsible for the safety. The installations must sufficiently satisfy the respective official specifications. 6.1. Installation The erection and installation must be done by an approved technical facility. This facility will also take on the responsibility for correct installation and commissioning. A dry, frost-free room that provides sufficient space for maintenance work is requried as the installation site. The shift layer module must be installed so that it is protected from splashing water and should be run only at room temperatures below 40 C. 6

Wall installation Wall installation takes place as follows with the included attachment material (3x M10 stair bolts, M10 nuts and 3 M10 washers): 1. Drill at least 8 cm deep on the designated drill points with a ø 12 mm according to the Drillling template (rear part insulation) included. 2. Afterwards, insert wall plug into the hole and screw the stair bolts into the wall until the wall plug threads are no longer visible. 3. Now hang the shift layer module on the threaded bolts and mount it using the flat washers and nuts. 7

Drillling template for wall installation 8

Tank installation Tank installation takes place as follows in 3 steps with the installation material included: Step 1: (Image above) Install and tighten the 3 threaded rods onto the respective tank connectors. Step 2: (Image above) Push the shift layer module over the threaded rods and fix the module to the tank using the flat washers and nuts. Step 3: (Image right) Install the 3 corrugated tubes with the seals to the module. 9

6.2. Hydraulic connection Line connection takes place according to the installation layout in this manual. See 1.2. Application example: The line paths to the buffer should be as short as possible! We recommend steel or copper piping as line material. The installation order is to be followed for all lines and fittings in order to prevent electrochemical corrosion. Installation of a gravitational heating system is not permitted! Connection of the collection circuit expansion tank must take place as a direct connection. Installation of shut-off valves (except for suitable maintenance units like cap valves) is not permitted! Connections are to be tightened only after the tubing has been sealed. Tightening torques or impact of forces on components and connections that have already been pre-mounted must be avoided at all costs! Additionally, check all flat sealing screws for proper swivel nut tightening torque (screws can become loose during transport!). 6.3. Electrical connections Internal wiring of electrical equipment is conducted onsite. Connection to the power supply (230 V/AC, 50 Hz) takes place by means of the preclamped supply cable. The buffer sensors included are installed on the respective buffer tank metering points according to their labelling Buffer top and Buffer bottom and connected to the affected control clamps as well as the collector sensor included in the scope of delivery. The controller manual contains comprehensive information on the controller integrated in the module. Work on live parts of the module is carried out only after following the respective regulations of the electricity supply company and the relevant standards applicable. 10

6.4. Commissioning Only use water prepared according to the standards (e.g., ÖNORM H 5195-1:2010). All lines must be diffusion resistant. Filling and commissioning must be done by an approved technical facility and concessionary personnel. Here, the function and tightness against leaks of the entire plant including the parts assembled in the manufacturing works should be checked. Safety valve functionality is to be checked at regular intervals. Annual maintenance by an approved technical facility is recommended. Opening the ball valves slowly at the inlet and outlet of the module prevents pressure shocks during the rinsing process. Use the cleaning connections provided for filling the collector circuit. See 7.1. Construction. The filling and rinsing must be carried out until it is ensured that the system is completely de-aerated. Flow noises during buffer pump operation indicate that there is still air in the machine that can be removed via the pump and manual primer. Close the collector return line at the end of the filling process and adjust the system pressure to approx. 3 bar (this applies to expansion tanks with a system pressure of 2.5 bar, the static height of the machine must be taken into consideration as well). Before opening each control box housing, ensure that it is disconnected from the power supply! Do not fill in direct sunlight because this can lead to steam hammering! 11

Cleaning and filling the collector circuit: The filling and rinsing must be carried out until it is ensured that the system is completely de-aerated. Flow noises during collector pump operation indicate that there is still air in the machine that can be removed via the manual primer. Before beginning with the cleaning and/or filling process, please read through this item well. Solar-side (collector side) See 7.1. Construction. 1. Only heating glycol water mixtures (frost-resistant to at least -25 ) may be used for filling the solar circuit. 2. Before beginning with cleaning and filling, make certain that all connections (solar forward/return flows, etc.) are provided with correct seals and are tightly connected. 3. Connect the fill pump forward flow to KFE valve A (filling nozzle). 4. Connect the fill pump return flow to KFE valve B (purging nozzle). 5. First, open KFE valve A (handle in flow direction). 6. Now, open KFE valve B (handle in flow direction). 7. Start the cleaning process of the solar circuit by switching on the filling pump. 8. Let the pump run until the glycol water mixture flows back into the tank without bubbles. 9. Close KFE valve B (handle against flow direction). 10. Pay attention to the gauge. 11. When the gauge has reached the desired operating pressure, close KFE valve A (handle against flow direction). 12. Now, the pump can be switched off and the filling pump connections can be disconnected from the KFE valves A and B. 13. The solar circuit is now completely filled and ready for use. 14. Should air noise be discovered in the circuit during operation, then begin with point 1 again. 12 Buffer-side 1. Only heating water can be used according to norm ÖNORM H 5195-1:2010 for filling the buffer circuit and buffer tank. 2. Before you start connecting the lines from the shift layer module to the buffer tank, shut the ball valves C, D and E (handle in the direction opposite to the flow) on the shift layer module.

3. Before beginning with filling, make certain that all connections are provided with correct seals and are tight. 4. Now, open all valves to the connection lines on the buffer tank. 5. Now open valve C, then valve D and finally, valve E at the shift layer module. 6. If no water noise is heard, switch the buffer circuit pump on manually. See separate SKSC 3+ Controller user's manual. 7. Let this process run for several minutes. Afterwards, switch the pump off. 8. Vent the buffer tank and top-off with heater water if necessary. 9. The buffer circuit is now completely filled and ready for use. 13

7. Technical Data Dimensions Cover Solar piping Width Height Depth SLM50HE 470 mm 850 mm 285 mm EPP black RG 60 g/l Copper pipe ø 22 mm * 0.8 mm Buffer piping Metal hose stainless steel 1.4404, ø 26.2 mm * 0.18 mm Weight ~ 25 kg Connections A KFE valve filling nozzle G3/8" AG B KFE valve purging nozzle G3/8" AG C Buffer return line cold G1" AG D Buffer return line warm G1" AG E Buffer return line hot G1" AG F Solar inflow line G1" AG G Solar return line G1" AG Maximum operating pressure Collector circuit Buffer circuit Solar pump Nominal voltage Nominal output max. delivery height Buffer loading Nominal voltage pump Nominal output Plate heat exchanger (glycol/water) H max. delivery height Power Inlet temperature Outlet temperature Flow rate amount Expansion tank G3/4" AG connection, position in the solar return line high-pressure side max. 6 bar max. 3 bar 230 VAC / 50 Hz 4 70 W 0.3 7.5 m 230 V / 50 Hz 4 70 W 0.3 7.5 m ~ 26 kw 60 C (glycol) / 29 C (water) 35 C (glycol) / 54 C (water) 970 kg/h 14

7.1. Construction 1 Temperature sensor inflow 2 Electrical actuator 3 Mixing block 4 Heat exchanger 5 Reset valve buffer circuit 6 Buffer block 7 High-efficiency pump buffer circuit 8 Flow meter (electronic) 9 Pressure control valve max. 6 bar 10 Reset valve solar circuit 11 Solar block 12 Monometer 13 Collector block 14 High-efficient pump solar circuit 15 Flow meter (electronic) 16 Solar vent 17 Solar return line 18 Temperature sensor solar inflow line A B C D E F G H KFE valve A filling nozzle KFE valve B filling nozzle Connection C buffer return line COLD Connection D Buffer return line BOTTOM Connection E Buffer return line TOP Connection F solar return line Connection G solar return line Expansion tank 15

8. Spare parts Pos. no. Article description Article designation Article no. 2 Actuator for switching valve SLM50HE-SA 130523 8, 15 Flow sensor VFS 2-40 SLM50HE-DFS 130524 5, 10 Valve insert volume flow control SLM50HE-VES 130525 9 Pressure control valve 6 bar with safety cotter pin SLM50HE-ÜDV 130527 12 Manometer 10 bar axial SLM50HE-MM 130528 16 Solar vent 3/8" SLM50HE-EL 130529 - Cotter pin set SLM50HE SLM50HE-SS 130530 - Seal set SLM50HE SLM50HE-DS 130531 - Tank connector set for SLM50HE SLM50HE-SAS 130532 - Installation set for SLM50HE SLM50HE-MS 130533-3-circuit control SKSC3+ SKSC3+ 141170 A, B KFE valve 3/8" SLM50HE-KH10 130534 7 Tank charge pump UPM2 15/75 SLM50HE-SLP 130535 14 Collector charge pump Solar PM2 15/75 SLM50HE-KLP 130536 - - Insulation (black) incl. logo and icon (5-part) for SLM50HE Insulation (black) incl. logo and icon (5-part) for SLM50HE-O SLM50HE-ISO 130537 SLM50HE-O-ISO 130538 D Ball valve, 1 both way incl. 2 seals, red SLM50HE-KH25R 130567 C Ball valve, 1 both way incl. 2 seals, blue SLM50HE-KH25B 130568 E Angle type ball valve, 1 both way incl. 2 seals, red SLM50HE-KHE 130569 - Valve insert for 3-way switching-valve SLM50HE-VES 130526 9. Warranty The purchaser has a warranty of 2 years from the date of purchase on the module and its components. Installation and use of the module as specified is required for this. 16

Pump characteristic line Declaration of Conformity The product conforms to relevant guidelines and thus has the CE label. The Declaration of Conformity can be requested from the manufacturer. 17

Notes 18

Notes 19

Deutschland Sonnenkraft Deutschland GmbH Clermont-Ferrand-Allee 34 93049 Regensburg Tel.: +49 (0)941 46 46 3-0 Fax: +49 (0)941 46 46 3-31 E-mail: deutschland@sonnenkraft.com Österreich Sonnenkraft Österreich Vertriebs GmbH Industriepark 9300 St. Veit/Glan Tel.: +43 (0)4212 450 10 Fax: +43 (0)4212 450 10-377 E-Mail: office@sonnenkraft.com Italia Sonnenkraft Italia S.r.l. Via G. B. Morgagni 36 37135 Verona (VR) Tel.: +39 045 82 50 239 Fax: +39 045 82 50 127 E-Mail: italia@sonnenkraft.com France SONNENKRAFT France 16 Rue Saint Exupéry 67500 Haguenau Tél.: +33 (0)3 90 59 05 00 Fax: +33 (0)3 90 59 05 15 E-Mail: france@sonnenkraft.com España Sonnenkraft España S.L. C/La Resina 41 a, Nave 5 28021 Madrid Tel.: +34 91 505 29 40 Fax: +34 91 795 56 32 E-Mail: espana@sonnenkraft.com Sonnenkraft International Sonnenkraft Solar Systems GmbH Industriepark 9300 St. Veit/Glan Tel.: +43 (0)4212 450 10-400 Fax: +43 (0)4212 450 10-477 E-Mail: international@sonnenkraft.com Scandinavia Sonnenkraft Scandinavia A/S Stengårdsvej 33 4340 Tølløse Tel.: + 45 59 16 16 16 Fax: + 45 59 16 16 17 E-Mail: info@sonnenkraft.dk Portugal Sonnenkraft Portugal Rua Henrique Callado, n 6 piso 2 B21 Edificio Orange - Leião 2740-303 Porto Salvo Tel.: (+351) 214 236 160 Fax: (+351) 214 217 233 E-Mail: portugal@sonnenkraft.com Schweiz SONNENKRAFT Schweiz AG Seetalstrasse 13 6020 Emmenbrücke Tel.: +41 41 260 21 21 Fax.: +41 41 260 21 31 E-mail: schweiz@sonnenkraft.com United Kingdom Sonnenkraft Solar Systems Ltd. www.sonnenkraft.co.uk uk@sonnenkraft.com www.sonnenkraft.com