An Assessment of Radiator Performance

Similar documents
Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

2. HEAT EXCHANGERS MESA

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Transcritical CO2 Bottle Cooler Development

Dual-Purpose Air Conditioner

CONTROLLED CHILLED BEAM PUMP MODULE

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Heat sinks for electronic cooling applications

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment

A Novel Approach for the Thermal Management. of PC Power Supply

How to improve air cooler vacuum steam condensers performance in the field

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

STANDARD HEAT EXCHANGERS

RIGID DC LIQUID CHILLER

Best Practices for Condensing Boilers

Figure 1: Overview of CO 2 evaporator types

Pocket Dilution Cooler

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

NOREN Products. Compact Cabinet Coolers

Fike set out to develop a better understanding of the power density trends in data centers around the world.

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS

Product Data. Features/Benefits ComfortLink control

CTI Sponsored Educational Program

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Guide To Troubleshooting INEFFICIENT COOLING FANS

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

Adding More Fan Power Can Be a Good Thing

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

THERMAL ICE STORAGE: Application & Design Guide

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Case 13 Food Storage & Processing Center

HVAC considerations for lamp and laser projectors in cinema

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

The Basics of Package/Device Cooling

2.2. General view of Microchannel Heat Exchangers

Ultimate energy saving technology

Technical Development Program

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

CONTROLLED CHILLED BEAM PUMP MODULE

Heat pump supplemental heating system for motor vehicles

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Hints and Tips for Thermal Design for Discrete Semiconductor Devices Part 3

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

The electrical wattage needed by the circulator is:

Slide 2 The type of coils we will be talking about today are round copper tube, flat fin coils.

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

Enclosure Temperature Control

INFRARED 101 How Does It Work and Will It Make You Money?

A Review of Hydronic Balancing of Cooling Water Circuit

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

commercial refrigeration products

Application Note Heat Transfer Design Team 7 Compact Inverter Jack Grundemann

SEALED ENCLOSURE COOLING

EHH SERIES DRAW THROUGH FAN COILS CFM

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Induction Billet Heaters with Enthalpy Controlled Zone Heating

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

ASHRAE Headquarters Building: GSHP vs. VRF systems

The Way We Were and Are Going on Cooling High Power Processors in the Industries

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

"Best Practices in Modern Hydronic Heating - THE DETAILS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Optimisation of cooling coil performance during operation stage for improved humidity control

30GN FLOTRONIC II AIR-COOLED CHILLERS

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

Single-Felt Dryer Sections

70% Save time and money with MCHE standard products. MicroChannel Heat Exchangers. Lower refrigerant charge

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Ultimate energy saving technology

MECHANICAL SCIENCE Module 2 Heat Exchangers

30GT FLOTRONIC AIR-COOLED CHILLERS

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

Electric Coils. Blower Coils. Product Information

Ambient (ºF) Temperature Rise Above

Thermal management architectures for rack based electronics systems. Sukhvinder Kang, David Miller Aavid Thermalloy, Concord NH, USA

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Performance Assessment of Water Cooled Condenser Refrigeration System

Technical Papers. 37th Annual Meeting. International Institute of Ammonia Refrigeration. March 22 25, 2015

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III

Thermal Performance of a Loop Thermosyphon

Implications of GHP Fan Control Strategies on Humidity Control in Commercial Applications

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

WHITE PAPER: Cooling Industrial Enclosures with Filter Fans

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

Transcription:

An Assessment of Radiator Performance By William Adams September 9, 2005 Table of contents 1. Test Equipment and Procedures...2 2. Radiator Descriptions...3 3. Performance Testing...4 a. Group 1: Single Row Radiators...4 b. Group 2: Dual Row Radiators...6 c. Group 3: Miscellaneous Radiators...7 4. Summary: The Best 120mm Radiators Compared...9 5. 80mm Radiators...11 6. Conclusions...13 Page 1 of 13

Introduction This is a survey of radiator types in use in watercooling systems for personal computers. The focus of the survey is limited to the assessment of radiator performance with a single fan, selected on the basis of its noise to performance ratio. Limited also were the sizes, only radiators for a single120mm fan were compared, although two 80mm radiators were included to illustrate the difference between 1-pass and 2-pass configuration. Comparisons are made initially within a given type of radiator, and then between the different types. Note that this testing was performed not to assess the ultimate performance capability of the radiators; for each this would occur at the maximum air and liquid side flow rates, together with the maximum temperature difference between the hot and cold sides. This test regime is noise limited and is effected by using a single fan, the Delta WFB1212M for 120mm radiators @ 34db(A) and a Delta AFB0812H for 80mm radiators @ 31db(A). 1. Test Equipment and Procedures Testing was performed in a Forma Scientific environmental chamber to control the ambient temperature; while the circulated coolant was held at 35 C with a Haake A82 recirculating chiller. Air and coolant temperatures were taken at equilibrium and measured to 2 decimal places with Fluke 2A thermometers using an average where there were fluctuations. Flow was measured with a ½ Rosemount 8712C magnetic flow meter and pressures with a Foxboro 823DP differential pressure transducer, again measured to 2 decimal places using Philips PM2534 DMMs. The photo below shows a typical bench test setup. All 120mm radiator testing was done with a single fan, a Delta WFB1212M turning at 2100 RPM producing 72.4 CFM (no restriction) with a noise SPL of 34 db(a). This fan was selected due to its moderate noise and relatively good performance compared to other fans with similar noise characteristics. For 80mm radiators a Delta AFB0812H is used having an SPL of 31 db(a). The coolant was distilled water and 5% HydrX. The temperature difference was 10 C for the 120mm radiators and 15 C for the 80s. These differentials were selected to reflect actual usage conditions; i.e. watercooling systems with single small radiators will run hotter than with larger or multiple radiators. Page 2 of 13

2. Radiator Descriptions The following radiators were compared to each other in groups. Their attributes and dimensions are summarized in Table 1 below. a. 120mm class Group 1 o MCR120-QP: Swiftech s MCR120-QP is a single row, 2-pass configuration but utilizes a somewhat wider tube than others. o Black Ice Pro (BIP): Made by HW Labs, the BI Pro is a single row, 2-pass configuration. o BI Cross Also by HW Labs. The BI Cross (X-Flow?) is the same radiator core as the BI Pro, but with different headers to convert it from a 2-pass to a single-pass, or cross flow configuration o Corsair Hydrocool: The radiator supplied in the Corsair Hydrocool was removed to test its performance. It is all aluminum and a 2-pass design. Group 2 o Black Ice Extreme (BIX): Made by HW Labs, the BIX is a 2 row variant of the BI Pro, again a 2-pass configuration. o ThermoChill 120.1: Made by ThermoChill, the 120.1 is a 2 row, 2-pass radiator in its original version. o CoolRad-12T: Made for CoolingWorks, the CoolRad-12T is another 2 row, 2-pass radiator. o CoolWave: The CW120S2 is a generic OEM radiator having a 2 row, 2-pass configuration. Group 3 o Hayden: Made by Hayden as a prototype for Swiftech, a stacked plate brazed all aluminum radiator in a 1-pass configuration. o D-Tek Pro: The D-Tek Pro is a 2-pass cut down corrugated plate heater core to a typical 120mm fan dimension. o Lytron: This Lytron model was the initial Swiftech radiator in 2000; it is similar to the current model M05-050 but has 2 more tubes. It is a continuous tube of copper, with soldered fittings on one side, and flat aluminum sheets are pierced and crimped around the tubes for fins. b. 80mm class o o MCR80-QP: Swiftech s MCR80-QP is a single row, single pass radiator. Black Ice (BI Micro): Made by HW Labs, the BI Micro is a dual row 2-pass configuration. Table 1 Model/Attributes Material (tube/fin) Frontal area, in² Volume, in³ Number of tubes/rows Fins per inch, FPI Shroud depth, in. MCR120-QP Brass/cu 21.6 18.8 12/1 13.5 0.26 BI Pro, single 120 fan 22.9 14.9 12/1 17 0.24 BI Cross, single 22.9 14.9 12/1 17.3 0.24 Corsair (Hydrocool) Alu/alu 22.6 18.1 15/1 18.5 0.32 BI Extreme, single Brass/cu 22.9 32.1 12/2 17.5 0.21 ThermoChill 120.1 23.3 29.1 12/2 22.5 0.36 CoolRad-12T 23 29.2 12/2 16.5 0.24 CoolWave, single 21.9 27.5 12/2 17.5 0.30 Hayden (prototype) Alu/alu 23.3 29.1 10/1 12 0.58* D-Tek Pro Brass/cu 26.1 51.4 12/1 11 0.58* Lytron (~=MO5-050) Cu/alu 23.8 35.6 10/offset 22 0.60 MCR80-QP Brass/cu 9.5 8.2 8/1 17 0.25 BI Micro 8.8 12.3 8/2 17 0.23 *External shroud added to flat faced radiators Page 3 of 13

3. Performance Testing c. Group 1: Single Row Radiators The first group of radiators tested was that having a single row of tubes. All of these radiators are a 2-pass configuration. 7 6 Graph 1 Single Row Radiators Pressure Drop vs. Flow Rate 5 4 3 2 1 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 MCR120 QP BIP-120 BI Cross 1/2 Corsair alu The large range of pressure drops reflects the difference in design and construction of these four radiators. The BI Cross (a cross flow configuration, corner to opposite corner) has the same core (tubes and fins) as the BI Pro; the greatly reduced flow resistance is due not only to that configuration (1 pass vs. 2 pass) but also to the 1/2 barbs whereas all the other radiators tested had 3/8 barbs. The high flow resistance of the Corsair aluminum radiator is due to the structure of the tubes. 200 190 Graph 2 Single Row Radiators Heat Dissipated vs. Flow Rate heat dissipated, W 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 MCR120 QP BIP-120 BI Cross 1/2 Corsair alu Page 4 of 13

The above is the conventional plotting of heat dissipated vs. flow rate and the Swiftech MCR120-QP and the Corsair radiators have an advantage over both BI models. Note that the flow rate range of interest is between 1 and 1.5 gpm as most US designed systems will have flow rates in that range. If graphs 1 and 2 are combined, one can see the resulting dissipation as a consequence of the pressure drop. Graph 3 200 Single Row Radiators Heat Dissipated vs. Pressure Drop 190 heat dissipated, W 0 1 2 3 4 5 6 7 pressurre drop, psi MCR120 QP BIP-120 BI Cross 1/2 Corsair alu Now the MCR120-QP and the BI Cross have higher dissipation when the radiators pressure drop is also considered. By counting the line symbols from left to right the flow rate is also known, the markers flow rates being 0.3, 0.5, 1.0, 1.5, 2.0, and 3.0 GPM. It can be seen that the MCP120-QPs dissipation is exceeded by the BI Cross only when the flow rate is beyond 2 GPM, a situation most unlikely in a pc water cooling system. Under certain situations a single pass radiator may be useful, but generally their performance will always lag that of a 2-pass due to the lower tube fluid velocity. There are exceptions, one circumstance of which is described in the 80mm radiator tests below. Another way to plot the above is substituting thermal resistance for the heat dissipated. 0.075 Graph 4 Single Row Radiators Thermal Resistance vs. Pressure Drop 0.070 0.065 0.060 0.055 0.050 0 1 2 3 4 5 6 7 MCR120 QP BIP-120 BI Cross 1/2 Corsair alu Page 5 of 13

This presentation is more useful as if the system flow rate and the total heat load are known, then the coolant temperature can be estimated using the C/W. Group 2: Dual Row Radiators Dual row radiators exist to handle higher heat loads than single row versions, all shown have a 2-pass configuration. Graph 5 5.0 Dual Row Radiators Pressure Drop vs. Flow Rate 4.0 3.0 2.0 1.0 0.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 BIX-120 ThermoChill 120.1 CoolRad-12T CoolWave All four of the dual core radiators are similar in construction, even to the nominal tube dimensions; the lowest pressure drop being that of the CoolRad-12T. Graph 6 200 Dual Row Radiators Heat Dissipated vs. Flow Rate Delta WFB1212M fan, 10 C coolant to air temperature difference 190 heat dissipated, W. 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 BIX-120 ThermoChill 120.1 CoolRad-12T CoolWave The BI Extreme and its clone, the CoolRad-12T, perform similarly with the edge to the CoolRad-12T at higher flow rates. The CoolWave was close, while the ThermoChill 120.1 indicates it needs more airflow to perform well. Page 6 of 13

Graph 7 200 Dual Row Radiators Heat Dissipated vs. Pressure Drop Delta WFB1212M fan, 10 C coolant to air temperature difference 190 heat dissipated, W. 0 1 2 3 4 5 BIX-120 ThermoChill 120.1 CoolRad-12T CoolWave Again, when plotting heat dissipated vs. the pressure drop; the edge, other things being equal, will go to the radiator having the lower flow resistance. The same relationship can be seen in graph 8 below by plotting the radiators thermal resistance against the pressure drop. Graph 8 0.075 Dual Row Radiators Thermal Resistance vs. Pressure Drop Delta WFB1212M fan, 10 C coolant to air temperature difference 0.070 0.065 0.060 0.055 0.050 0 1 2 3 4 5 BIX-120 ThermoChill 120.1 CoolRad-12T CoolWave d. Group 3: Miscellaneous Radiators This assorted group includes corrugated plate (heater core), continuous tube, and aluminum stacked plate (oil cooler) configurations. Note that all 3 radiators are specifically made to the 120mm format thus eliminating the gross size differences that normally inhibit the comparison of these types. Page 7 of 13

Graph 9 7 Miscellaneous Radiators Pressure Drop vs. Flow Rate 6 5 4 3 2 1 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Hayden alu D-Tek Pro core Lytron cu tube Expectedly the D-Tek Pro (cut down) heater core has low flow resistance while the copper continuous tube and the aluminum stacked plate designs have similarly high pressure drops. Graph 10 200 Miscellaneous Radiators Heat Dissipation vs. Flow Rate Delta WFB1212M fan, 10 C coolant to air temperature difference 190 heat dissipated, W 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Hayden alu D-Tek Pro core Lytron cu tube Bearing in mind that the flow rate range of interest is 1 to 1.5 gpm, it can be seen that the heater core is well optimized for this application. Page 8 of 13

Graph 11 200 Miscellaneous Radiators Heat Dissipated vs. Pressure Drop Delta WFB1212M fan, 10 C coolant to air temperature difference 190 heat dissipated, W 0 1 2 3 4 5 6 7 Hayden alu D-Tek Pro core Lytron cu tube From this graph it is clear that a heater core is a more effective design than either stacked aluminum plates or continuous tube, insofar as these models can be considered representative of their type/size. The continuous tube Lytron radiator is typical of the type, while the Hayden prototype is somewhat unique due to the greater plate width than their standard products. Graph 12 0.080 Miscellaneous Radiators Thermal Resistance vs. Pressure Drop Delta WFB1212M fan, 10 C coolant to air temperature difference 0.075 0.070 0.065 0.060 0.055 0.050 0 1 2 3 4 5 6 7 Hayden alu D-Tek Pro core Lytron cu tube 4. Summary: The Best 120mm Radiators Compared How is best defined for a radiator? Clearly it is the greatest cooling with the least pressure drop. On this basis the MCR120 QP and the BI Cross should be considered from the single row group, the CoolRad-12T from the dual row group, and the D-Tek Pro from the miscellaneous group. Note that the BI Cross is included although it is not directly Page 9 of 13

comparable due to having 1/2 barbs while all the other radiators had 3/8. With the same size barbs it would not be close due to the higher pressure drop. Graph 13 0.075 Top Performing Radiators Thermal Resistance vs. Pressure Drop 0.070 0.065 0.060 0.055 0.050 0 1 2 3 4 5 pressure drop.psi MCR120 QP BI Cross 1/2 CoolRad-12T D-Tek Pro core Here the MCR120 QP and the BI Crossflow are similar through 2 gpm, but this is due to the larger barbs on the crossflow. Another way to consider the performance is to plot the thermal resistance vs. the hydraulic power. Hydraulic power represents the work expended pumping coolant through the radiator and is found by calculating the pressure drop by the flow rate by a constant (depending on the units used). 0.075 Graph 14 Top Performing Radiators Thermal Resistance vs. Hydraulic Power 0.070 0.065 0.060 0.055 0.050 0 1 2 3 4 5 6 7 hydraulic power, W MCR120 QP BI Cross 1/2 CoolRad-12T D-Tek Pro core What is being illustrated here is the work required to achieve a given thermal resistance. It can be seen that the MCR120 QP is a more effective solution until flow rates exceed 2 gpm. So what can be concluded regarding 120mm radiator types, bearing in mind that the fan is pre-determined based on noise and the flow rate range of interest is 1 to 1.5 gpm? The flat tube and folded fin radiators were slightly superior to corrugated plate heater cores, both of which were appreciably better than continuous tube or stacked plate aluminum oil coolers. Note that stacked plate aluminum oil coolers can be very effective, but not the size and configuration tested. Page 10 of 13

While all the brass/copper tube/fin radiators were superior to the aluminum, this difference is not related to the materials, rather to the specific tube design of the Corsair radiator resulting in high flow resistance (but contributing to the cooling as well a tradeoff). 5. 80mm Radiators Two 80mm radiators were tested to illustrate the differences between a single row, 1-pass; and dual row, 2-pass configurations. 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 Graph 15 80mm Radiator Comparison Pressure Drop vs. Flow Rate 0.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 MCR80-QP BI Micro Notwithstanding the difference between having one and two rows of tubes and one and 2-pass configuration, the flow resistance of the two is quite similar due to the MCR80-QP s single row of tubes being larger, and having a single pass configuration. Graph 16 80mm Radiator Comparison Heat Dissipation vs. Flow Rate Delta AFB0812H fan, 15 C coolant to air temperature difference heat dissipated, W 120 110 100 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 MCR80-QP BI Micro Page 11 of 13

While the flow resistance of the two 80mm radiators is similar, the MCR80-QP provides ~10% better dissipation in the flow range of interest, 1 to 1.5 gpm. Graph 17 80mm Radiator Comparison Heat Dissipation vs. Pressure Drop Delta AFB0812H fan, 15 C coolant to air temperature difference heat dissipated, W 120 110 100 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 MCR80-QP BI Micro The same advantage of the MCR80-QP over the BI micro is apparent above. Graph 18 0. 80mm Radiator Comparison Thermal Resistance vs. Pressure Drop Delta AFB0812H fan, 15 C coolant to air temperature difference 0. 0.120 0.110 0.100 0.090 0.080 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 MCR80-QP BI Micro The difference in the C/Ws indicates that with a 100W load, the MCR80-QP will drop the coolant temperature 1 C+ in the flow range of interest. Page 12 of 13

Graph 19 0. 80mm Radiator Comparison Thermal Resistance vs. Hydraulic Power Delta WFB0812H fan, 15 C coolant to air temperature difference 0. 0.120 0.110 0.100 0.090 0.080 0 1 2 3 4 5 6 hydraulic power, W MCR80-QP BI Micro And the MCR80-QP s higher performance is apparent no matter how the data is presented. This superiority of a single row over a dual row is due to the more efficient use of the fan s output. Single row cores have lower air flow resistance and with lower powered fans achieve greater throughput than the same fan with dual row cores. Notwithstanding the greater fin surface area in a dual row core, the lower air velocity reduces the convection more than the increased area increases it. 6. Conclusions Dual row radiators and heater cores have a greater heat rejection capability than single row, but to utilize the higher capability stronger fans must be used to overcome the airflow resistance. Stronger fans make more noise and it was found that with an upper limit of 34 db(a) there is no way to achieve higher performance using a dual row core similar to those tested. Some may ask: What is a radiator s rating? The answer is it depends. Specifically any rating will, indeed must, define the flow rates on both the air and liquid sides and the temperature difference between the two sides. All of the thermal resistance and dissipation graphs above describe the ratings of these radiators, but the air side flow rate is not known, only the air source (the fan) is held constant. Putting a more, or less, powerful fan on the radiator would necessitate new curves to define its rating. There is no single value that describes a radiator s rating without also stating the flow and temperature conditions. Page 13 of 13