Safety instructions VEGATOR 121, 122

Similar documents
Safety instructions Display and adjustment module

Safety instructions VEGAPULS 62

Safety instructions VEGASWING 61, 63

Safety instructions VEGAVIB 61, 62, 63

Safety instructions VEGACAP 62, 63, 64, 65, 66

Safety instructions VEGAPULS 69

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Safety instructions VEGAPULS 64

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Safety instructions VEGABAR 81, 82, 83, 86, 87

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Mounting instructions. Rinsing connection. for VEGAPULS WL 61, 61, 64, 67 and 69. Document ID: 49552

Manual Isolating Barrier D461R1 (Revision 01)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Safety instructions VEGAMIP MPR61(*).G*/DK****R/T*** VEGAMIP MPT61(*).G*/DK****T*** VEGAMIP MPR62(*).G******R/T*** IECEx BVS Ex t IIIC T..

PEPPERL+FUCHS GmbH

Manufacturer declaration. 3-A, Installation and Cleaning Instructions. VEGAPULS 63 Hygienic process fittings. Document ID: 46197

Supplementary instructions Bypass 72 Bypass tube with VEGAFLEX level sensor

Technical Data. Dimensions

OPTIBAR P 1010/2010 C Supplementary instructions

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

IECEx Certificate of Conformity

SET Installation and Operating Instructions. Level switch for one sensor

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

OilSET-1000 (12 VDC)

Hygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGAVIB VB61, VB63 Hygienic process fittings. Document ID: 35483

OPTIBAR DP 7060 Supplementary Instructions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

EN ISO/IEC :2016/AC

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Manual Isolating Barrier D461 (Revision 05)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Gas cylinder scale Model GCS-1

Certificate of Compliance

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Physikalisch-Technische Bundesanstalt

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Technical Data. Dimensions

IECEx Certificate of Conformity

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

SET-2000 Hi Level/Oil

PROTECT SRB 200EXi-1A

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

UL HAZARDOUS LOCATIONS SERVICES

Certificate of Compliance

OPTIWAVE X500 Supplementary Instructions

VERSAFLOW VORTEX Supplementary instructions

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Annubar Flowmeter Series

Operating Instructions Conductive probe EL 1

DICTATOR Hold-Open Systems for Hazardous Areas

SVENSK STANDARD SS-EN

Indoor/outdoor resistance thermometer Model TR60

SET-2000 Oil/Sludge 12 VDC

IECEx Certificate of Conformity

Rosemount 3490 Series

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Intrinsically Safe Solutions

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Certification Supplement Manual

IECEx Certificate of Conformity

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

EU DECLARATION OF CONFORMITY

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

MANUAL Oil Level Sensor

Certification Supplement Manual

Operating Instructions VEGATOR 122. Double channel signal conditioning instrument for level detection for 8/16 ma sensors. Document ID: 46108

User s Manual YTA610 and YTA710 NEPSI Certification

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Certificate of Compliance

Operating Instructions. Conductive probe EL 1. Conductive rod electrode. Document ID: 32651

Smart encoders & actuators

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

MANUAL Overflow sensor NVF-104/34-PF

HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY PART 2-95: PARTICULAR REQUIREMENTS FOR DRIVES FOR VERTICALLY MOVING GARAGE DOORS

Manual Power relay SR853

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Transcription:

Safety instructions Intrinsic safety TÜV 14 ATEX 134822 TÜV 14 ATEX 134826 X 0044 Document ID: 47469

Contents 1 Area of applicability... 4 2 General information... 4 3 Technical data... 4 4 Installation... 5 Supplementary documentation: Operating Instructions EU-type approval certificate TÜV 14 ATEX 134822, Issue 00 (Document ID: 47470) Conformity statement TÜV 14 ATEX 134826 X, Issue 00 (Document ID: 47556) EU declaration of conformity (Document ID: 46604) Editing status: 2017-12-08 2

DE EN FR IT ES PT NL SV DA FI EL DE EN FR ES Sicherheitshinweise für den Einsatz in explosionsgefährdeten Bereichen Safety instructions for the use in hazardous areas Consignes de sécurité pour une application en atmosphères explosibles Normative di sicurezza per l'impiego in luoghi con pericolo di esplosione Instrucciones de seguridad para el empleo en áreas con riesgo de explosión Normas de segurança para utilização em zonas sujeitas a explosão Veiligheidsaanwijzingen voor gebruik op plaatsen waar ontploffingsgevaar kan heersen Säkerhetsanvisningar för användning i explosiionsfarliga områden Sikkerhedsforskrifter til anvendelse i explosionsfarlig atmosfare Turvallisuusohjeet räjähdysvaarallisisssa tiloissa käyttöä varten Υποδείξεις ασφαλείας για τη χρησιμοποίηση σε περιοχές που υπάρχει κίνδυνος έκρηξης Die vorliegenden Sicherheitshinweise sind im Download unter www.vega.com standardmäßig in den Sprachen deutsch, englisch, französisch und spanisch verfügbar. Weitere EU-Landessprachen stellt VEGA nach Anforderungen zur Verfügung. These safety instructions are available as a standard feature in the download area under www.vega.com in the languages German, English, French and Spanish. Further EU languages will be made available by VEGA upon request. Les présentes consignes de sécurité sont disponibles au téléchargement sous www.vega.com en standard en allemand, en anglais, en francais et en espagnol. VEGA met à disposition d'autres langues de l'union Européenne selon les exigences. Las indicaciones de seguridad presentes están disponibles en la zona de descarga de www.vega.com de forma estándar en los idiomas inglés, francés y español. VEGA pone a disposición otros idiomas de la UE cuando son requeridos. 3

1 Area of applicability These safety instructions apply for signal conditioning instruments VEGATOR TOR121**S/X****, TOR 122 according to EU type approval certificate TÜV 14 ATEX 134822, Issue 00 (certificate number on the type label) and conformity statement TÜV 14 ATEX 134826 X, Issue 00 (certificate number on the type label) and for all instruments with the number of the safety instructions (47469) on the type label. 2 General information The signal conditioning instruments VEGATOR TOR121**S/X****, TOR 122 are used for intrinsically safe power supply of two-wire transmitters, the reliable galvanic separation from all other circuits and the processing of analoguously transmitted measured data. The signal conditioning instruments VEGATOR TOR121**S/X****, TOR 122 depending on limit values are used for generation of binary output signals on the floating, non-contact relay output. The signal conditioning instruments VEGATOR TOR121**S/X****, TOR 122 work in conjunction with 8/16 ma (current jump signal) limit switches and are mainly used for level detection or pump control for VEGASWING, VEGAVIB and VEGAWAVE vibrating level switches with electronics version "Twowire". Hence simple control tasks can be solved. Typical applications are monitoring functions such as overfill and dry run protections. The 8 ma/16 ma input signals and relay outputs or used for control and monitoring of levels. The single channel signal conditioning instruments VEGATOR TOR121.**X****, VEGATOR TOR121.**S**** (with additional fail safe relay in the output) are for connection of a current jump signal (8 ma/16 ma) sensor and the double channel signal conditioning instrument VEGATOR TOR122 for connection of two current jump signal (8 ma/16 ma) sensors. Signal conditioning instruments VEGATOR TOR121**S/X****, TOR 122 must be mounted and operated outside hazardous areas and inside hazardous areas zone 2. The operating instructions as well as the installation regulations or standards that apply for explosion protection of electrical systems must generally be observed. The installation of explosion-protected systems must always be carried out by qualified personnel. Ignition protection label: II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC, I(M1) [Ex ia Ma] I II 3G Ex na nc ic IIC T4 Gc 3 Technical data The VEGATOR TOR121**S/X****, TOR 122 include non-intrinsically safe circuits and one intrinsically safe circuit. Non-intrinsically safe circuits Voltage supply: (connections 16/17) Relay outputs: (10/11/12, 13/14/15) U = 20 253 V AC U m = 253 V AC Maximum values: 253 V AC, 3 A 60 V DC, 1 A 4

Intrinsically safe circuit Signal circuit: (connections 1/2, 4/5) Ignition protection type intrinsic safety Ex ia IIC, IIB, I Maximum values: U o 22.4 V I o 113.5 ma P o 636 mw Characteristics: linear The effective internal inductance L i and capacity C i are negligibly small. The max. values of the table can also be used as concentrated capacitances and concentrated inductances. The values for IIC and IIB are also permitted for explosive dust atmosheres. Ex ia IIC IIB I Max. permissible external inductance L o 0.5 mh 10 mh 10 mh Max. permissible external capacitance C o 0.095 µf 0.55 µf 1.2 µf Application conditions Permissible ambient temperatures Permissible ambient temperature at the installation location of an instrument -20 +60 C (-4 +140 F) 4 Installation Signal conditioning instruments VEGATOR TOR121**S/X****, TOR 122 must be mounted and operated outside hazardous areas and inside hazardous areas zone 2. The protection rating of VEGATOR TOR121**S/X****, TOR 122 corresponds to IP 20. If the signal conditioning instruments VEGATOR TOR121**S/X****, TOR 122 are not set up in dry and clean environments, they must be mounted in a housing with the required protection rating. With zone 2 applications, the following special conditions must be noted: According to EN/IEC 60079-15, paragraph 6.3.1 the following applies for this instrument: or The instrument must be installed in a housing tested according to IEC 60079-0 meeting the requirements of protection rating IP 54. The instrument must be installed in a housing tested according to IEC 60079-0 meeting the requirements of protection rating IP 4X. The instrument must then be exclusively installed in areas offering also a suitable protection against penetration of impurities or liquids. The pollution degree of the area where the instrument is used must not exceed 2. With zone 2 applications, the torque of the terminals should be between 0.4 Nm and 0.5 Nm. If the intrinsically safe circuit is led into dust-explosive areas of zone 20 or 21, please make sure that the instruments connected to these circuits meet the requirements of category 1D or 2D and are certified respectively. 5

Notes 6

Notes 7

Printing date: All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice VEGA Grieshaber KG, Schiltach/Germany 2017 VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com www.vega.com