SERVICE BULLETIN A

Similar documents
SERVICE BULLETIN 43-R134

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

HEATING AND AIR CONDITIONING

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

MASS. MARITIME ACADEMY

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

Installation Manual Mopar Engine Compartment Upgrade Kit

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

SECTION 50 - CAB CLIMATE CONTROL

SERVICE MANUAL FOR MODEL RM-49

SERVICE MANUAL FOR MODEL RM-10

Harold Ag & Mobile Products

SERVICE MANUAL FOR MODEL RM-26

Refrigerant Recovery Machine. Model No Operating Manual

USING R-134A REFRIGERANT

Sleeper Heater and Air Conditioner, Blend Air System 83.05

Refrigerant Recovery Unit, Model RRU134

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

an ISO 9001:2015 Registered Company

A/C COMPRESSOR OIL CHECKING

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

an ISO 9001:2008 Registered Company ShortPac HEAT/COOL (05000-QUX-A/05000-VUX-A)

BC BRONCOS AIR CONDITIONING UNIT

MANUAL CONTROL HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

HEATING AND AIR CONDITIONING

A/C SYSTEM GENERAL SERVICING

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

A/C-HEATER SYSTEM - MANUAL

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET NOVA

5/12/2018 Climate Control System General Information and Diagnostics - Air Conditioning (A/C) System Recovery, Evacuation and Charging - G

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

CIRRUS AIRPLANE MAINTENANCE MANUAL

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

HEATING AND VENTILATION

WineZone Ceiling Mount Ductless Split 15

Auto Air Conditioning Compressors GENERAL CATALOGUE

Air Conditioning Operation and Troubleshooting Matt Dunham

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Condensing Unit Installation and Operating Instructions

TOYOTA FJ-40 DIRECTIONS

INSTALLATION INSTRUCTIONS

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

347002K/177002K/34900

USER MANUAL UN-200V / UN-200VH

PRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56

1. General Description

Installation Instructions

OWNER S MANUAL (English)

OPERATING INSTRUCTIONS

182T and T182T Air Conditioning System ICA Revision: Date: 17 September, 2008

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual

Toyota FJ40 Evaporator Upgrade Add-On Kit (751202)

an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL

DISTRIBUTION > HOUSING, HVAC > INSTALLATION > AIR INLET HOUSING

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

OPERATING INSTRUCTIONS

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Condensing Unit Installation and Operating Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

INSTALLATION INSTRUCTIONS

Hoshizaki America, Inc.

Ariazone 601HD Refrigerant Recovery&Recycling unit

PARAVION TECHNOLOGY, INC AIRWAY AVENUE FORT COLLINS, COLORADO 80524

CIRRUS AIRPLANE MAINTENANCE MANUAL

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

PL Series Premier Indoor Plenum Coils

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

Heavy Duty Heater / Air Conditioner Model R-8545

Vacuum Gauge. Measures lower-than-atmospheric pressure Digital scales. microns psi in. Hg millibars pascals torr millitorr

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

XC13. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R410A.

Hoshizaki America, Inc.

OPERATION & MAINTENANCE MANUAL AC860

TECHNICAL MANUAL OPERATOR S, AND MANINTENANCE MANUAL AIR CONDITIONER, HORIZONTAL COMPACT, 33,000 BTU/HR 208 VOLT, THREE PHASE, 400HERTZ,

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

Installation Manual Chevrolet Vehicles

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Transcription:

1. PLANNING INFORMATION A. Effectivity: Dassault Falcon 10 aircraft which have installed R-134a Upgrade Kit SZ59K-R134 before August 8, 2002. B. Reason: Upgrade kits before August 8, 2002 did not include the replacement of the three expansion valves. C. Description: This Service Bulletin gives instructions for installing the three new expansion valves. D. Compliance: Compliance is optional. E. Approval: This Service Bulletin has been approved by the FAA. Components are FAA-PMA. F. Manpower: Estimated labor hours is 28 hours ± 5 hours. Time should be allocated to 1) remove panels in the aft baggage compartment to gain access to the motor-compressor assembly, 2) Remove interior panels in the passenger compartment to gain access to the evaporator assembly. 3) Recover the R-134a refrigerant, 4) flush condenser and evaporator, 5) remove and replace the receiver-dryer, 6) remove evaporator assembly, 7) remove and replace the compressor, 8) replace the three expansion valves, check that each external equalizing tube is clear, 9) re-install evaporator assembly, 10) evacuate for 8 hours, 11) service with R-134a refrigerant, 12) re-attach all panels and secure interior. Evacuation time of 8 hours is not included in the above 28 hour estimate. G. Material cost and availability: Refer to Section IV for a detailed listing of parts and materials required to accomplish the modification procedures outlined in this Service Bulletin. The required parts and pricing is available from: Zee Systems, Inc. P.O. Box 791165 San Antonio, TX 78279-1165 USA TEL: 210-342-9761 FAX: 210-341-2609 Email: info@zeeco-zeesys.com H. Equipment and Tooling: Ground Power Unit (28VDC capable of 120A continuous) R-134a Refrigerant Poloyl Ester (POE) Oil, Compressor, or LUBRIZOL 2916 1 of 7

Nitrogen Bottle Recovery/Recycle Equipment which meets SAE J1990 or J2209. Manifold Gauge Set, R-134a compatible, w/ quick Disconnects. Manifold Gauge Set, R-12 compatible Scale.1 lb. Increments (or smaller) Leak Detector for R-134a Vacuum Pump, refrigerant I. Weight and Balance: No effect. J. Electrical Load Data: No effect. K. References: Refer to Zee Systems, Inc. DWG SZ59-001 for basic STC information. Refer to Dassault Falcon 10 Service Instructions from Maintenance Manual, Section 6-30-00 Section 12-16-00 Section 21-50-02 Section 21-50-06 Section 21-50-07 Section 21-50-11 Section 21-50-12 Section 21-50-14 Section 21-50-15 Differences to Falcon 10 Service Instructions from Maintenance Manual, Section 21-50-02 are as follows. 1. General Throughout the entire document change the word freon to refrigerant. 2. Special tools, materials and equipment Refer to this Service Bulletin when alternate service (replenishing) method is used. 3. Operation A.(7) Open the HP and LP valves on the manifold gauge set. Evacuate the system for 6 hrs (minimum) to 8 hrs. after attaining maximum vacuum. B.(7) Load to 3.2 lbs. (1.45 kg). 2 of 7

B.(8) Close the valves on the manifold gauge set and the filling cylinder when the system has reached 3.2 lbs. (1.45kg) C.(3) Do not use the bubbles to check the refrigerant charge when using R-134a refrigerant. Disregard steps (4) through (11). Refer to Section III of this Service Bulletin for alternate service (replenishing) instructions. II ACCOMPLISHMENT INSTRUCTIONS A. Preparation: The replacement of components should be accomplished in a clean, dry area free of oil, dirt, moisture and other contamination. CAUTION The air conditioning system is under pressure. Appropriate safety measures should be taken when servicing this equipment. Only trained personnel with safety equipment should perform these duties. NOTE It is unlawful to release R-12 to the atmosphere. Use approved Recovery/Recycle equipment to capture the R-12 refrigerant. Use only lawful means to dispose of the recovered R-12. Check with local agencies for approved disposal procedures. B. Disassembly: NOTE Cap all lines to prevent contaminants and moisture from entering the system. NOTE Standard air conditioning service equipment for mobile R-134a refrigerant system is used for this service. If you are using automatic service equipment some of the steps may be omitted, performed in a different order or combined with other steps. Refer to the operating instructions for the equipment you are using. Also, the following steps are recommended. If you have contracted an air conditioning service professional they may have different procedures to perform the same functions. 1. Recover the R-134a refrigerant. a. Attach the high side (red) connector for the R-134a manifold gauges to the high side service port. b. Attach the low side (blue) connector for the R-134a manifold gauges to the low side service port. c. Attach the yellow line to the recovery equipment. d. Connect the R-134a recovery bottle to the recovery equipment. e. Recover the R-134a refrigerant in accordance with the recovery equipment instructions. 2. Remove or disconnect the following components: 3 of 7

a. Disconnect the SZ58-2008 No. 8 (discharge) flex line at the compressor. This line runs from the compressor toward the condenser (runs to the aft). (Refer to Falcon 10 IPC 21-52-01, item 305). See Flushing instructions B., 1., a.. b. Disconnect the SZ58-20010 No. 10 (suction) flex line at the compressor. This line runs from the compressor toward the evaporator (runs forward). (Refer to Falcon 10 IPC 21-52-01, item 255). See flushing instructions B, 1., b. c. Replace the SZ59-050-1Receiver-Dryer (Reservoir, Tank). (Refer to Falcon 10 IPC 21-52-01, item 285). d. Replace the SZ84-913TJ-1 Compressor. Remove the pulley from the old compressor and install it on the new compressor. e. Remove the Evaporator Assembly. (Refer to Falcon 10 IPC 21-52-01, item 32, -32A) Refer to Falcon Maintenance Manual Section 21-50-11. f. The three Thermostatic Expansion Valves (Pressure Reducing Valves). (Refer to Falcon 10 IPC 40, -40A) Refer to Falcon Maintenance Manual Section 21-50-15. Each expansion valve has a capillary tube with a thermostatic bulb at the end. Each thermostatic bulb is attached to one of the three evaporator pipes in a precise position. Make note of the which valve is connected to which pipe and the position of each thermostatic bulb on the pipe to correctly reassemble. C. Flushing Instructions: 1. Before re-assembly the Condenser Coil and Evaporator Coil must be flushed to remove trapped mineral oil. a. Connect a source of dry nitrogen to the discharge side flex line (SZ59-2008). With the Receiver-Dryer removed, place a container to collect any oil at the end of that line. Blow the dry nitrogen through the condenser coil at 100-150 PSI. There is no way to determine the amount of oil trapped in the coil. Continue to force the dry nitrogen through the coil until all oil is removed. b. With the three expansion valves and three sampling tube removed from the evaporator cap the three No.4 sampling tube ports on the outlet tube. Connect a source of dry nitrogen to the first inlet tube. Place a container to collect the oil at the outlet tube. Blow the dry nitrogen through the evaporator coil at 75-100 PSI. There is no way to determine the amount of oil trapped in the coil. Continue to force the dry nitrogen through the coil until all mineral oil is removed. Repeat the process with the other two inlet tubes. D. Assembly Instructions: 1. Install the following components: a. The new SZ84-913TJ-1 Compressor and pulley. Before installing the compressor check the oil level. The horizontal depth should be 1-3/16 (30mm). Vertical depth should be 1-1/2 (38mm) minimum. Replenish as necessary with Poloyl Ester (P.O.E.) 4 of 7

b. On the top of the compressor align the No. 8 Discharge fitting ZEE P/N: 022-21960M as required to fit the hose to the compressor. Snug the bolt down; do not tighten at this time. c. Connect Hose Assembly P/N: SZ59-20010-1 to the compressor. Apply a light film of refrigerant oil to the O-Ring to help seating. d. Connect Hose Assembly P/N: SZ59-2008-1 to the compressor. Route this Hose over the No. 10 Hose at the compressor. Apply a light film of refrigerant oil to the O-Ring to help seating. Tighten the bolt holding the 022-21960M fitting on the compressor. Use a 5/16 12 point socket. Torque the 5/16 torx-head bolt to 17-25 ft.-lb. (23.0-33-9 N-m). e. Connect the SZ59-050-1A Receiver-Dryer to the hard lines. Be sure that the direction of flow is forward. Apply a light film of the refrigerant oil to the flare to help seat the seal area. Use a backup wrench and tighten. f. Tighten all connections. Torque the two 5/16 torx-head bolts on the compressor fittings to 17-25 ft.-lb. (23.0-33.9 N-m). g. Fit the evaporator with the three SZ84-760-2 Thermostatic Expansion Valves. Refer to Falcon Maintenance Manual Section 21-50-15, using plastic clamps P/N: MS3367-5-9 to replace the existing clips. Make sure that the thermostatic bulb for each valve is correctly positioned. Make sure that a good metal to metal seat between the thermostatic bulb and the pipe is achieved. Once attached, cover with the piece of insulating tape (provided with valve) to isolate the three from each other. Attach cover. Carefully uncoil only enough of the capillary tube necessary. Take care not to kink the capillary tube. There is no repair for a damaged capillary tube. If tube or bulb becomes damaged the valve must be replaced. h. Attach the sampling tube to each valve. i. Install the evaporator according to the instructions in the Falcon 10 Maintenance Manual Section 21-50-11, with new seal(s) P/N: F10A725009 on the evaporator return tube. Refer to Dassault modification M530 or SB F10-207 for seal location and installation information. A. Check: Check the system for leaks. 1. Pressurized the system to 100 PSIG with Nitrogen. DO NOT USE AIR 2. Use soap solution to check the connections. B. Evacuate the system. 1. Connect the R-134a manifold gauge set to the Discharge and Suction service ports. The high (red) and low (blue) side valves should be shut off at the manifold gauge. 2. Connect the yellow line from the manifold gauge set to the vacuum pump. 3. Start the pump. Open the high and low side valve at the manifold gauge set. Maintain a vacuum of 29.0-30.0 in-hg for 8 hours. During the evacuation period occasionally close the high and low side valves at the manifold gauge set. The vacuum reading should not change. Any change in the vacuum reading with the valves closed indicates a leak in the system. C. Service: Charge the System with refrigerant in accordance with Falcon Maintenance Manual Section 21-50-02. Note the changes the instructions as described in Section I, K of this Service Bulletin. 5 of 7

D. Alternate Service (Replenishing) instructions. 1. Weigh the refrigerant bottle. Make note of the weight. 2. Connect the yellow line on the manifold gauge set to the refrigerant bottle. a. With the valves on the manifold gauge closed bleed the air from the yellow line so only refrigerant will enter the system. 3. Introduce a static charge with the system NOT RUNNING. a. Open the valve on the refrigerant bottle. b. Slowly open the high and low side valves on the manifold gauge. Continue to add refrigerant until the pressures stabilize or until 3.2 lb.(1.45kg) of refrigerant is reached then close the valves on the manifold gauge. 4. Introduce a running charge. a. Connect external electrical supply unit. b. Set the FREON switch on the console to ON. Make sure the evaporator blowers are operating. c. Slowly open the LOW side valve on the manifold gauge set until the gauge reads 25-30 PSI. d. Continue to add refrigerant until the target weight of 3.2 lb.(1.45kg) is reached. When the target weight is reached immediately close the valve. e. Close the valve on the refrigerant bottle. 5. Disconnect the high and low side quick disconnect manifold fittings from the aircraft plumbing. 6. Check for leaks. 7. Make appropriate log book entries. IV. MATERIAL INFORMATION A. To accomplish the Service Bulletin, order Kit Part Number SZ59K-R134-1A. The kit contains the following items. QTY PART NUMBER DESCRIPTION OLD PART NUMBER DISPOSITION 1ea SZ59-050-1A* Receiver-Dryer 518-65590 or, DISCARD 536-65590 or, DISCARD 536-65590-1 or, DISCARD SZ59-050-1 or, DISCARD SZ59-050-1A DISCARD 1ea SZ84-913TJ-1 Compressor 520-65730 or, DISCARD EF210R16774 or, DISCARD 11-90355 DISCARD SZ84-913TJ-1 DISCARD 6 of 7

QTY PART NUMBER DESCRIPTION OLD PART NUMBER DISPOSITION 3ea SZ84-760-2 Expansion Valve TMSX or, DISCARD 528-65628-1 or, DISCARD 528-65628-2 DISCARD 2ea F10A725009** Seal F10A725009 DISCARD 9ea MS3367-5-9 Clamp DISCARD Alternate Dassault P/N: 78750-01 *Normal maintenance item. Replace anytime the system is interrupted. **One time use seal. Do not reuse old seal. 7 of 7