Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Similar documents
Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

Bedding Disposal Workstations The Portable Safety Solution for Animal Research Laboratories. Viva Bedding Disposal Workstation, Model VBD-4A_.

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Low Noise, Class II Microbiological Safety Cabinets The Industry's Most Comfortable, Energy Efficient Cabinet

Universal Applications

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

Forced Convection Laboratory Ovens Reliable Performance For Universal Applications

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

Forced Convection Laboratory Incubators. Reliable Performance For Universal Applications. Forced Convection Laboratory Incubators

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Class II Biological Safety Cabinets The World's Leading Energy Efficient, Quiet, and Compact Biosafety Cabinet.

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Class II, Microbiological Safety Cabinets The Industry's Premier Energy Efficient Solution from Esco

Forced Convection Laboratory Incubators. Reliable Performance For Universal Applications. Forced Convection Laboratory Incubators

Refrigerated Incubator. Reliable Performance For Universal Applications

Class II Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Class II, Microbiological Safety Cabinets The Industry's Premier Energy Efficient Solution from Esco

Formalin Vaporizer The Premium Solution for Biological Safety Cabinet Decontamination. Esco Formalin Vaporizer Model FV-00_

Forced Convection Laboratory Incubators. Reliable Performance For Universal Applications. Forced Convection Laboratory Incubators

Class II Microbiological Safety Cabinet The Industry's Premier Biological Safety Solution from Esco

SubliMate. Bench Top Laboratory Freeze Dryers. Designed and Made in the E.U.

Class II, Australian Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Low Noise, Class II Biological Safety Cabinets The Safety Solution for Life Science Laboratories

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Microbiological Safety Cabinets

Airstream Class II, Biological Safety Cabinet (E-series),

Ultra-low Temperature Freezer ULT Vault for Your Samples

Ultra-low Temperature Freezer ULT Vault for Your Samples

CO2 Incubators Cradle for Beautiful Cells. CelCulture CO2 Incubator

SubliMate. Bench Top Laboratory Freeze Dryers. SubliMate Bench Top Laboratory Freeze Dryer Model FDL-5

Ultra-low Temperature Freezer ULT Vault for Your Samples

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

Biological Safety Cabinet

Ultra-low Temperature Freezer ULT Vault for Your Samples. Lexicon Ultra-low Temperature Freezer Model UUS-668A-1

CO 2 Incubators Cradle for Beautiful Cells. CelCulture CO 2 Incubator Model CCL-170_-_

Ultra-low Temperature Freezer ULT Vault for Your Samples

CelCulture CO2 Incubators CelCulture for IVF. Cradle for Beautiful Cells. Cradle for Optimal Embryo Incubation. Designed in the USA

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Cradle for Beautiful Cells. CelCulture CO 2 Incubators. Designed in the USA

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Cradle for Beautiful Cells. CelCulture CO 2 Incubators

CelSafe ESCO GLOBAL NETWORK. The Safest Way To Grow Your Beautiful Cells

CelCulture CO2 Incubators CelCulture for IVF. Cradle for Beautiful Cells. Cradle for Optimal Embryo Incubation. Designed in the USA

LABORATORY CABINETS 103

Innovation in air purification unmatched air quality

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Lexicon II. with New Aalto Controller. Lexicon II Ultra-low Temperature Freezers 1. Uncompromised Protection for your Samples. Designed in the USA

Clean Bench Animal Transfer Stations

CelMate. CO 2 Incubators. CelMate. Incubators. CelMate CO 2 Incubators. Cradle for Beautiful Cells

IVF/ART Series Laminar Flow Cabinets

Lexicon II Ultra-Low Temperature Freezer 1. Ultra-Low Temperature Freezer. Lexicon II. Uncompromised Protection for your Samples. Designed in the USA

CelCulture for IVF. Cradle for Optimal Embryo Incubation

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

INCREASE YOUR LAB EFFICIENCY

Safe Operating Procedure (Revised 2/10)

Biological Safety Cabinets or Fume Hoods Which one to use?

L a b o r a t o r y E q u i p m e n t C a t a l o g

ENVAIR lab CO2 Incubator

BIOLOGICAL SAFETY CABINET

CLEAN AIR SYSTEM.

BioSafety Cabinet- Class 100

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

Gelaire BH-EN and UltraSafe cabinets

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

Biological Safety Cabinets. Biological Safety Cabinets

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

Down flow clean air cabinet Star of the Universe. Fortuna

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Thermo Scientific 1300 Series A2

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

Microbiological Safety Cabinets ENVAIR eco safe Comfort

B. Design meeting requirements of the particular class and type of cabinet as follows:

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

Fume Hood Safety TYPES OF FUME HOODS

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

Thermo Scientific Lindberg Blue M Ovens. Superior performance and accuracy for your most demanding applications

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

Precision Containment for All Applications

Cleanroom Air Showers

Thermo Scientific Lindberg Blue M Ovens. Superior performance and accuracy for your most demanding applications

User and Service Manual. Esco Controlled Environment Laboratory and Cleanroom Equipment Solutions. Class ll, Type A2 Biological Safety Cabinets

BioMAT 2 BioMAT 2-S2. Class 2 Microbiological. Safety Cabinets. Simple. Safe. Quiet. Efficient. To EN 12469:2000

Laminar Flow Cabinets eco air V

Laboratory Automation & Robotic System Enclosures

ESCO. A Guide To Biosafety & Biosafety Cabinets

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Transcription:

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories Airstream Class lll, Biological Safety Cabinet, Model AC3-4B_.

Main Features Exhaust air is double-filtered through high-quality ULPA filters (per IEST-RP-CC-001.3) with typical efficiency of >99.999% for 0.1 to 0.3 micron particles, better than HEPA filters. Exclusive dual exhaust filters provide >100,000 times better protection than single-stage designs. Microprocessor-based Esco Sentinel Silver control system provides visual / audible alarms for airflow. Magnehelic* pressure gauge is mounted in the rear of the work zone for at-a-glance monitoring of work zone negative pressure. Neoprene gauntlets are single piece leak-tested glove assemblies which guarantee maximum protection. An integrated pass-through with interlocking doors permits materials transfer without risk of environmental contamination. Esco antimicrobial surface on all painted surfaces minimizes contamination. An angled cabinet front ensures an ergonomic working posture. Cabinet operates at negative pressure relative to the laboratory in order to prevent migration of pathogenic materials out of the work area. *Registered trademark of Dwyer Instruments, Inc. Airstream Class III Biological Safety Cabinet. Model AC3-4B_. Biological Safety Cabinets Class III Biological Safety Cabinets

capability than conventional HEPA filters that have a typical efficiency of >99.99% for 0.3 micron particles. Modern separator-less mini-pleat filter construction maximizes the filter surface area to extend filter life and eliminates possible filter media damage by thin and sharp aluminum separators used in conventional HEPA filter construction. The filter frame and media is constructed in accordance with EN18 requirements for fire retardant properties The supply ULPA filter provides ISO Class 3 (per ISO14644.1) clean air to the work surface in a gentle vertical flow for product protection. The dual exhaust ULPA filters trap aerosols generated in the work area before air is exhausted to the room providing personnel and environmental protection. The exhaust filter media is protected from mechanical damage by an integrated metal screen guard, which is absent from conventional HEPA filters. Neoprene synthetic arm-length gauntlets are flame and abrasion resistant. Single piece, leak-tested assembly guarantees maximum protection. Black color allows the detection of leaks by visual means. Containment and Protection The Esco Airstream Class III Biological Safety Cabinet provides the industry s best protection for high-hazard applications. Complete welded construction ensures an air-tight carcass for absolute containment, operator and environmental safety. Dual exhaust ULPA filters deliver superior protection - the combined typical efficiency of the two exhaust filters in series allows only 1 particle out of 10 billion (of 0.1-0.3 microns size) to penetrate. Filtration efficiency is even higher for particles larger than 0.3 microns or smaller than 0.1 microns. Inflow room air is ULPA filtered to establish product protection; unfiltered room air does not enter the work zone, preventing product contamination. Integrated pass-through with interlocking doors allows materials and equipment to be easily passed into the main chamber without the risk of environmental contamination. Magnehelic* pressure gauge mounted in the rear wall of the work zone enables continuous monitoring of work zone negative pressure. Operator, Product and Environmental Protection The Esco Airstream Class III Biological Safety Cabinet (AC3) offers the highest possible level of containment and protection. The cabinet's airtight seal and advanced ULPA filtered laminar airflow provides product, operator and environmental protection and is suitable for use with agents assigned to Biosafety Levels 1,, 3 and 4. The AC3 is frequently used for work involving the deadliest biohazards, bacteria, viruses and microorganisms. Mini-pleat Separatorless Filter (left) vs. Conventional Aluminum Separator Filter (right) Esco cabinets use Swedish Camfil Farr mini-pleat filters without aluminum separators to increase filter efficiency, minimize the chance of leakage, and to prolong filter life. Filters include a lightweight aluminum frame for structural stability and elimination of swelling common to conventional wood frames. Blower System The Airstream blower system is designed for high performance operation, maximum energy efficiency and minimal maintenance. Dual fan design ensures cabinet containment and operator safety in the event of a single fan failure. The permanently lubricated direct-drive external rotor motor / blower reduces operating costs. The external rotor motor design allows for optimum cooling of the motor during extended operations and extends the motor bearing life. An integral blower hour meter tracks operating life and aids in predictive maintenance planning. Sentinel TM Microprocessor Control, Alarm, Monitoring System The Esco Sentinel microprocessor-based control system supervises operation of all cabinet functions. 3 *Registered trademark of Dwyer Instruments, Inc Integrated Filtration System A combination of a supply ULPA filter and dual exhaust ULPA filters give the AC3 cabinet a fully integrated performance envelope for product, operator and environmental protection. ULPA filters (per IEST-RP-CC001.3), are tested to a typical efficiency of >99.999% for 0.1 to 0.3 micron particles; these provide better filtration Esco ULPA Filter Efficiency Typical Penetration Independent supply and exhaust filters provide 99.999% typical efficiency for particle sizes of 0.1 to 0.3 microns. Airstream Series filters meet the IEST-RP-CC001.3 recommended practice for ULPA performance (USA), and EN 18 for H14 performance (EU).

Cabinet Filtration System Dynamic air barrier, inflow and forward-directed downflow air converge Ambient air is pulled into the cabinet through a disposable pre-filter, trapping larger particles and prolonging the life of main filter. Air is then passed through the downflow ULPA filter into the work zone as a vertical laminar flow air stream, bathing the work surface in clean air. The uniform non-turbulent air stream protects against cross contamination within and throughout the work area. Near the work surface, the downflow air stream splits and exits the chamber through perforations around the perimeter of the work zone. ULPA-filtered air Unfiltered / potentially contaminated air Room air / Inflow air Air from work zone passes through the first ULPA exhaust filter below the work surface, before traveling through internal ducting and exhausting to the laboratory environment after passing through the second ULPA exhaust filter located above the cabinet's main chamber. Biosafety Cabinets For Air Quality For Filtration For Electrical Safety Standards Compliance EN 1469, Europe ISO 14644.1 Class 3, Worldwide IEST-G-CC1001, USA IEST-G-CC100, USA IEST-RP-CC034.1, Worldwide IEST-RP-CC007.1, Worldwide IEST-RP-CC001.3, Worldwide EN 18 (H14), Europe IEC 61010-1, Worldwide EN 61010-1, Europe UL 61010-1, USA CAN/CSA-., No. 61010-1 4 The control panel is located in the center of the cabinet and angled down for easy access by the operator. Cabinet airflow is monitored continuously and displayed on a bright, easyto-read LCD display. An integrated, temperature-compensated true airflow velocity sensor provides an accurate airflow reading despite room temperature fluctuation. All electronic parts are contained inside a plug-and-play module that permits easy exchange if required. Microprocessor software updates are available from Esco for download via the Internet. Sentinel functions are factory set to default to ON or OFF, depending on worldwide destination and local preferences. Default settings can be user activated through the touchpad data entry access. Automatic start-up sequence will prepare the cabinet for normal operation and advise when safe conditions are established. An administrator controlled PIN (personal identification number) can be set to restrict access to main menu. The airflow alarm can be activated or deactivated depending on user preference and nature of the work. Consult your Esco Operating Manual or contact your Sales Representative for information on user-preference programming capabilities built into the Sentinel microprocessor platform. Cabinet Construction Robust construction and enhanced safety features qualify the cabinet for the most demanding laboratory applications. The cabinet is fully assembled and ready to install and operate when shipped. All stainless steel work surface is easy to clean. Optional electrical service fittings are located for easier access. 8" Glove Sizes External surfaces are coated with Esco Isocide antimicrobial coating to protect against surface contamination and inhibit bacterial growth. Isocide eliminates 99.9% of surface bacteria within 4 hours of exposure. Industrial grade support frame constructed of electro-galvanized steel with an abrasion resistant finish. Comfortable Ergonomic Design The AC3 cabinet is engineered for comfort, utility value and safety. The angled front improves reach into the work area and reduces glare from the glass surface. The instant-start 5000k fluorescent lamp operates on an electronic ballast to reduce heat, improve comfort and conserve energy. To find out your glove size, measure (in inches) around your hand with a tape measure at the place indicated on the diagram. This measurement, in inches, is the closest to your glove size, i.e. 8 is equal to a glove size of 8. You should use your dominant hand, the right if you are righthanded, and the left if you are left-handed. Standard glove sizes available are 7, 8 (standard size) and 9. Specify when ordering. Biological Safety Cabinets Class III Biological Safety Cabinets

Touchpad data entry buttons permit control settings and access to diagnostics, default settings and hierarchical menus. Color coded indicator lamps display green for primary function (fan operation); blue for secondary function (fluorescent lights and electrical outlet); and orange for caution (UV lamp ON). Programmable automatic UV light timer simplifies operation, enhances contamination control, extends UV lamp life and saves energy. Digital read-out with alpha-numeric display indicates all input, status and alarm functions. All functions can be user activated through touch-pad programming access; see Operations Manual. Sentinel Microprocessor Control System, Programmable When programmed ON the start-up sequence confirms status with Air Safe and local time display. the Personal Identification Number (PIN) access restricts unauthorized adjustments. an airflow alarm warns of deviations from normal velocities. The lamp delivers uniform lighting to the work surface for greater comfort, reduced glare and improved productivity (see Technical Specifications). Neoprene synthetic arm-length gauntlets are flame and abrasion resistant. Single piece, leak-tested assembly guarantees maximum protection. Black color allows the detection of leaks by visual means. Glove ports are designed for easy and safe glove changing. Electrical Safety and Certification All components meet or exceed applicable safety requirements. Each cabinet is individually factory tested for electrical safety. Documentation specific to each cabinet serial number is maintained on file. All electrical components are UL-listed or recognized. Contact Esco or your Sales Representative for site preparation information (see Electrical Specifications). Warranty The AC3 is warranted for 3 years excluding consumable parts and accessories. Each cabinet is shipped with a comprehensive User s Manual complete with a report documenting all test procedures. Additional IQ/OQ documentation is available upon request. Contact your local Sales Representative for specific warranty details or documentation requests. Accessories and Options Esco offers a variety of options and accessories to meet local applications. Contact Esco or your local Sales Representative for ordering information. Electrical Outlets and Utility Fixtures Electrical outlet, ground fault, North America Electrical outlet, Europe / Worldwide Cabinet Accessories Germicidal UV lamp - Controlled by automatic UV lamp timer through Sentinel TM microprocessor control panel 5 Antimicrobial Powder-Coating Bacterial Population (10 fold) 8 6 4 All exterior painted surfaces are powder-coated with Esco Isocide, an antimicrobial inhibitor to minimize contamination. Isocide is integrated into the coating substrate and cannot wash out or diminish by repeated cleaning. Performance results are available upon request. Contact Esco or your Esco Sales Representative for details. 0 4 hours 8 hours 1 hours 16 hours 0 hours 4 hours Contact Time in Hours

General Specifications, Airstream Class lll, Biological Safety Cabinets Note to customer: Insert electrical voltage number into last model number digits _ when ordering Model AC3-4B AC3-5B AC3-6B Nominal Size 1. meters (4') 1.5 meters (5') 1.8 meters (6') External Dimensions (W x D x H) 1665 x 850 x 50 mm 65.6" x 33.5" x 88.6" 1970 x 850 x 50 mm 77.6" x 33.5" x 88.6" 75 x 850 x 50 mm 89.6" x 33.5" x 88.6" Internal Work Area, Dimensions (W x D x H) 1340 x 560 x 650 mm 5.8" x.0" x 5.6" 1645 x 560 x 650 mm 64.8" x.0" x 5.6" 1950 x 560 x 650 mm 76.8" x.0" x 5.6" Internal Work Area, Space 0.75 m (8.1 sq.ft) 0.9 m (9.9 sq.ft) 1.09 m (11.7 sq.ft) Number of Gloves Ports ports 4 ports 4 ports Glove Type & Sizes Available Neoprene TM polychloroprene synthetic rubber gauntlets. Available in sizes 7, 8 (standard size) and 9 Initial Airflow Volume 603 m 3 /h ( 355 cfm) 756 m 3 /h ( 445 cfm) 90 m 3 /h (531 cfm) Negative Work Zone Pressure -75 Pa (-1.1" Wg) 6 Pre-Filter ULPA Filter Typical Efficiency (Downflow, 1st Exhaust, nd Exhaust) Sound Emission (Typical)* Disposable and non-washable polyester fibers with 85% arrestance / EU3 rated Typical: 99.999% at 0.1 to 0.3 μm and MPPS NSF 49 <54 dba <55 dba <56 dba EN 1469 <51 dba <5 dba <53 dba Fluorescent Light Intensity At Zero Ambient Cabinet Construction Electrical** Main Body Work Zone >000 Lux (>186 foot candles) >1800 Lux (>167 foot candles) >000 Lux (>186 foot candles) 1.5 mm (0.06") 16 gauge electro-galvanized steel with white oven-baked epoxy-polyester Isocide antimicrobial powder coated finish 1. mm (0.05") 18 gauge stainless steel, type 304, with 4B finish 0-40V, AC, 50Hz, 1 AC3-4B1 AC3-5B1 AC3-6B1 Cabinet Full Load Amps (FLA) 3 A 3 A 3 A Optional Outlets FLA 5 A 5 A 5 A Cabinet Nominal Power 361 W 430 W 455 W Cabinet BTU 13 1467 1553 110-10V, AC, 60Hz, 1 AC3-4B AC3-5B AC3-6B Cabinet Full Load Amps (FLA) 10 A 11.5 A 11.5 A Optional Outlets FLA 5 A 5 A 5 A Cabinet Nominal Power 536 W 586 W 60.5 W Cabinet BTU 189 000 117 Net Weight 498 kg (1096 lbs) 598 kg (1316 lbs) 676 kg (1487 lbs) Shipping Weight 606.5 kg / 1337 lbs 615 kg / 1356 lbs 70 kg / 1587 lbs Shipping Dimensions, Maximum (W x D x H) 600 x 1950 x 130 mm 10.4" x 76.8" x 5.0" 600 x 150 x 130 mm 10.4" x 84.6" x 5.0" 600 x 150 x 130 mm 10.4" x 84.6" x 5.0" Shipping Volume, Maximum 6.69 m³ (36 cu.ft.) 7.38 m³ (61 cu.ft.) 7.38 m³ (61 cu.ft.) * Noise reading in open field condition/ anechoic chamber. ** Additional voltages may be available; contact Esco for ordering information. (Cont.) - Emission of 53.7 nanometers for most efficient decontamination Ergonomic lab chair - Laboratory grade construction, meets Class 100 cleanliness; alcohol resistant PVC materials - Adjustable height 395-490 mm (15.6"- 19.3") Ergonomic foot rest - Angled, helps maintain proper posture - Adjustable height - Anti-skid coating, chemical resistant finish Formalin vaporizer The Airtsream Class lll Biological Safety Cabinet is available in all stainless steel construction for pharmaceutical grade applications, contact Esco or your Sales Representative for more details. Biological Safety Cabinets Class III Biological Safety Cabinets

900 mm (35.4") 340 mm 13.4" 650 mm (5.6") 50 mm (100.4") 50 mm 9.8" Airstream Model AC3 Class lll Biological Safety Cabinet Technical Specifications Model AC3-4B_ Model AC3-5B_ 15 15 1 1 1 13 1 13 14 14 450 mm 17.7" 330 mm 13.0" 1340 mm (5.8") 1665 mm (65.5") 1645 mm (64.8") 1970 mm (77.6") Model AC3-6B_ Common Side View 50 mm 9.8" 7 15 3 10 4 11 1 13 1 5 6 90 mm (11.4") 14 7 8 450 mm 17.7" 450 mm 17.7" 9 1950 mm (76.8") 75 mm (89.6") 850 mm (33.5") 1 Esco Sentinel microprocessor control system. Pass box 3. Pre- filter 4. Electrical & electronics panel 5. ULPA filter (downflow) 6. Fluorescent light 7. Glove ports 8. First exhaust ULPA filter 9. First exhaust blower 10. Second exhaust ULPA filter 11. Second exhaust blower 1. UV lamps (optional) 13. Pressure gauge 14. Work zone back wall: optional electrical outlet Retrofit Kit provisions ( outlets in work zone one on each side) 15. Exhaust collar (optional)* *NIOSH Alert: If biosafety cabinets are used for minute quantities of volatile toxic chemicals and trace amounts of radionucleotides, they must be exhausted through properly functioning exhaust canopies.

8 Biological Safety Cabinets Compounding Pharmacy Equipment Containment / Pharma Products CO Incubators Ductless Fume Hoods In-Vitro Fertilization Workstations Lab Animal Research Products Laboratory Fume Hoods Laboratory Ovens and Incubators Laminar Flow Clean Benches PCR Products Ultralow Freezer Since 1978, Esco has emerged as a leader in the development of controlled environment, laboratory and pharmaceutical equipment solutions. Products sold in more than 100 countries include biological safety cabinets, fume hoods, ductless fume hoods, laminar flow clean benches, animal containment workstations, cytotoxic cabinets, hospital pharmacy isolators, and PCR cabinets and instrumentation. With the most extensive product line in the industry, Esco has passed more tests, in more languages, for more certifications, throughout more countries than any biosafety cabinet manufacturer in the world. Esco remains dedicated to delivering innovative solutions for the clinical, life science, research and industrial laboratory community. www.escoglobal.com. Biological Safety Cabinets and Laminar Flow Laboratory Fume Hoods Laboratory Ovens Laboratory Incubators PCR Thermal Cyclers Microplate Shaker/Incubators Ultralow Freezers Esco Technologies, Inc. 940 Turnpike Drive, Units 15-16 Hatboro, PA 19040, USA Toll-Free USA and Canada 877-479-376 Tel 15-441-9661 Fax 15-441-9660 us.escoglobal.com usa@escoglobal.com Esco Micro Pte. Ltd. 1 Changi South Street 1 Singapore 486 777 Tel +65 654 0833 Fax +65 654 690 mail@escoglobal.com www.escoglobal.com Esco Global Offices Beijing, China Kuala Lumpur, Malaysia Manama, Bahrain Guangzhou, China Hanoi, Vietnam Melaka, Malaysia Mumbai, India Philadelphia, PA, USA Salisbury, UK Shanghai, China Seoul, Korea Delhi, India Osaka, Japan Manila, Philippines Midrand, South Africa Jakarta, Indonesia Singapore 9010016_Biological Safety Cabinet_AC3_Brochure_A4_vC1_01/1 Esco can accept no responsibility for possible errors in catalogues, brochures and other printed materials. Esco reserves the right to alter its products and specifications without notice. All trademarks and logotypes in this material are the property of Esco and the respective companies. escoglobal.com LIVE SUPPORT Esco Micro Pte Ltd Cert. No: 651076 PT Esco Bintan Indonesia Cert. No: 651333/E