ESSENCIA INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER TO BE KEPT BY THE OWNER

Similar documents
OPALIA INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER TO BE KEPT BY THE OWNER

to the owner s Manual and the owner important: To be kept for the owner Chromatherapy and WarmTouchShell TM.

OWNER S MANUAL IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER

GEYSAIR TM ADDENDum. to the owner s Manual. and the owner

Laurel Mountain Whirlpools. Walk-In Bathtub Installation Manual

COPPER FREESTANDING TUB

Whirlpool Bathtub Model Number: MT618

ARLEY STEAM SHOWER ENCLOSURE

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

FREWIN STEAM SHOWER ENCLOSURE

LEVENS STEAM SHOWER ENCLOSURE

Installation and Operation Manual MG-304. Please read this manual carefully before use.

Acrylic Claw Foot Tub

OWNER S MANUAL WISTERIA

owner s manual produitsneptune.com Do not discard. Save these instructions for further use.

IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.

NEPTUNE Steam Room Installation Instructions

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Kallista Bath Flip Drain

ELLA SOAKING WALK IN BATHS OWNERS MANUAL. Representing these model numbers: L / R Elite Soaking L / R Royal Soaking

SYSTEM BASIC WHIRLPOOLS

Destination Collection Whirlpool Bath Installation Instructions

RESIN FREESTANDING TUB

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Threaded Faucet Installation

Installation Instructions

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Installation Instructions

Vintage Whirlpool Baths: K-702-AC K-702-H-AC CA (9427) Copyright 1994 Kohler Co.

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

CAST IRON PEDESTAL TUB

1-866-PENNERS

Access Tubs. Installation & operating instructions COSTCO MODEL # / RIGHT COSTCO MODEL # / LEFT

#PSBTWE1000 INSTALLATION GUIDE

ATTENTION INSTALLER: Please deliver this manual to homeowner.

INSTALLER: Save these instructions. for owner. owner s + operator s. manual

Acrylic Claw Foot Tub

STAINLESS STEEL TUB INSTALLATION

STOP ACRYLIC TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

Cable Drain & Cable Drain Trim Kit

Access Tubs 3053 HYDRO INSTALLATION & OPERATING INSTRUCTIONS MODEL INSTALLATION & OPERATING INSTRUCTIONS

SUPPLEMENTARY INSTRUCTIONS

UNIVERSAL TEE STYLE Hydromassage Bath Heater INSTALLATION INSTRUCTIONS

Before you begin, carefully read the installation instructions below. Observe all local electrical safety and plumbing codes.

Ella Gel Coat Walk In Tub E SERIES OWNER'S MANUAL

Hydrotherapy Jets (Remote Water Quality System)

1PIECE FREESTANDING BATHTUB

Infrared Room Installation & Operation Instructions

ACRYLIC PEDESTAL TUB

controls - user guide important information for the installer and the owner

STOP RESIN TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

Glass Vessel Sink Installation

SAVE THESE INSTRUCTIONS

WALK IN BATH TUB OWNER S MANUAL

Meditub. Installation & operating instructions. Operating instructions

O W N E R S MANUAL ROUGE

Spa Control System OWNER S MANUAL

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

CAST IRON CLAWFOOT TUB

Installation Instructions PRO SERIES

ELLA SOAKING WALK IN BATHS OWNERS MANUAL REPRESENTING THESE MODEL NUMBERS: L / R Elite Soaking L / R Royal Soaking

Next Generation Corona Discharge Installation & Operation Manual

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

WINE AND BAR SERIES. Sink Installation Kit. For assistance, call ; for UK ; at

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

OWNER S MANUAL ENTREPRENEUR

K-870-JA-AA K-872-JA-AA

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

ELLA MASSAGE WALK IN BATHS OWNERS MANUAL

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

WALK-IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

STOP. For missing, damaged parts or technical help, Call before returning product

Installation Guide. Install your new sink with step-by-step instructions.

Basin Set INSTALLATION INSTRUCTIONS

Viking Installation Guide

Technical Specifications Section 1

IMPORTANT INSTALLATION and OPERATING INSTRUCTIONS

Access Tubs 3238 DUAL ( AIR/HYDRO ) INSTALLATION & OPERATING INSTRUCTIONS MODEL INSTALLATION & OPERATING INSTRUCTIONS. Costco Item # /394831

Dishwasher. Installation manual DW60M9990AP

Installation Instructions

ODEON OVE. A. Ordering Information. B. Required Electrical Service T01-C INSTALLATION INSTRUCTIONS

STAINLESS STEEL OFFSET DOUBLE BOWL SINK

- INSTALLATION - USER S GUIDE - - REPLACEMENT PARTS -

Access Tubs. Installation & operating instructions. Costco Item # /394831

WALK-IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Installation & operating instructions

Model: M630-44FDC CAUTION:

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

SWIVEL HEAD WASTE AND OVERFLOW INSTALL

Installation Instructions

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Top Control Dishwasher

Access Tubs 3060WCA AIR INSTALLATION & OPERATING INSTRUCTIONS MODEL INSTALLATION & OPERATING INSTRUCTIONS

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Transcription:

IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER TO BE KEPT BY THE OWNER

TABLE OF CONTENT IMPORTANT SAFETY INSTRUCTIONS...1 PARTS & TOOLS...3 SITE PREPARATION...6 INSTALLATION REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH...7 REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH...22 CUTTING TEMPLATES: ELECTRONIC CONTROLS...34 2 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS THIS DOCUMENT SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER S MANUAL. Risk of hyperthermia; people using medication and/or having an adverse medical history should consult a physician before using a Hydro-thermo massage bathtub equipped with a heater. Risk of hyperthermia and possible drowning: do not use a Hydro-thermo massage bathtub equipped with heater immediately following strenuous exercise. Risk of fetal injury; pregnant or possibly pregnant women should consult a physician before using a Hydro-thermo massage bathtub equipped with a heater. Risk of accidental injury or drowning; do not use drugs or alcohol before or during the use of a Hydro-thermo massage bathtub equipped with a heater. Use this unit only for its intended purposes or as described in this manual. Use only accessories or devices recommended by the manufacturer. Risk of hyperthermia and possible drowning. Check and adjust water temperature before use. Water temperature exceeding 100ºF (38ºC) may be injurious to your health. To reduce the risk of injury, as with any other conventional bath, do not allow children or physically impaired people to use this unit unless they are closely supervised at all times. To avoid injury, exercise care when entering or exiting the Thermomasseur. The Geysair (option) should always be connected to the hot water intake. If it is not the case, then, the Geysair option should be deactivated via the bath control. RISK OF ELECTRICAL SHOCK Disconnect electric power before servicing. Do not permit electrical appliances (hair dryer, lamp, telephone, radio, television, etc.) within 5 (1,5 m) of the Thermomasseur. Before using the Thermomasseur, its exterior construction (podium or skirting) should be finished so that a bather cannot accidentally come in contact with electrical components (turbine and power module). For indoor use only. www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 1

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS (cont d) PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS THIS DOCUMENT SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER S MANUAL. ELECTRICAL CONNECTIONS: Never drop or insert objects into any openings. The Thermomasseur must be connected only to a supply circuit that is protected by a 15 amp class A ground fault circuit interrupter (GFCI) for baths with 1 heated backrest and a 20 amp (GFCI) for baths with Geysair or for baths with 2 heated backrests. This interrupter is supplied by a certified electrician and must be tested on a regular basis in accordance with manufacturer s instructions. The GFCI ground must be connected. If defective, do not use the Thermomasseur. Disconnect immediately and call a certified electrician. Use 12 AWG (or greater) copper conductors that resist temperatures of at least 194ºF (90ºC). Canada only: for permanently connected units. A green-colored terminal (or a wire connector marked g., gr., ground or grounding) is provided within the terminal compartment (not applicable if unit supplied with an electric plug). To reduce the risk of electrocution, connect this terminal or connector to the grounding terminal of your electric service or supply panel with conductor equivalent in size to the circuit conductors supplying the equipment and be 12 AWG or more. All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and local building codes and regulations. Install in accordance with manufacturer s installation instructions. For Geysair-equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be tested between the bath grounding terminal and the bath power supply. Failure to perform the grounding continuity test could result in serious personal injury. WATER LEAK TEST Once plumbing is fully installed and before beginning any other work, fill the ThermoMasseur with water to overflow level and wait 30 minutes. Check all plumbing hook-ups and bath for leaks. BainUltra is not responsible for any water damage caused by improper installation (see Warranty section). 2 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

H ESSENCIA PARTS & TOOLS REQUIRED STANDARD PARTS - PLUMBING ESSENCIA 6838 & OVAL 7236 DESCRIPTION QTY A Plated drain clicker 1 B Locking nut 1 A B C Strainer 1 D Rubber seal 1 C E PVC Wired drain shoe 1 F PVC Piping 1-1/2 X 2 1 D G PVC Tee Connector 1-1/2 F-F 1 G F E PLUMBING STANDARD PARTS - ESSENCIA DESIGN OPTIONAL PARTS - ESSENCIA 6838 (1) DESCRIPTION QTY H Plated drain clicker 1 I Strainer 1 J Rubber seal 1 K Brass drain shoe 1 L 4 in. brass tailpiece 1 J I M Nylon conic shaped seal for drain 1 N Brass nut 2 O Brass pipe 1-1/2 x 3 with flange 1 P Nylon flat seal with flange 1 Q P O N M L K Q 1-1/2 male threaded adaptor 1 (1) : INTEGRATED WASTE & OVERFLOW OPTION www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 3

PARTS & TOOLS REQUIRED OPTIONAL PARTS PLUMBING (2) ISLAND TUB DRAIN (ITD) KIT Makes installation and servicing easier for removal of bath. Allows you to connect the bath drain tailpiece to the plumbing pipe without need for tightening to seal once the bath is lowered to the floor. (2): REQUIRED WHEN NO ACCESS IS POSSIBLE UNDER the BATH. Available only with ESSENCIA DESIGN & 6838 with integrated waste & Overflow. STANDARDS PARTS FLOOR ANCHOR DESCRIPTION QTY R Floor anchor 2 S Threaded anchor (Oval 7236 & Design) 2 R T 1/2 Nut 13 zinc (Oval 7236 & Design) 2 U 1/2 Flat washer 2 (Oval 7236 & Design) V #10 X 1-1/2 Countersunk head screw 12 (Oval 7236 & Design) W Seals (Oval 7236 & Design) 2 W V U T S 4 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

PARTS & TOOLS REQUIRED STANDARDS PARTS THERMOMASSEUR DESCRIPTION QTY A Turbine 1 B MiaPlus Control(Essencia Design) 1 C Contrôle MiaMulti 1 (Essencia 6838 & Oval 7236) B D 15 extension cord 1 A C D PARTS & TOOLS REQUIRED Installation template 48-inch level Measuring tape Teflon tape Caulking gun Silicone ABS & PVC Glue Square/Phillips #2 Screwdriver 3/4 Ratchet Adjustable clamps www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 5

PLUMBING SITE PREPARATION See faucet manufacturer s specifications for zoning and plan water supply location accordingly. Position drain according to bath s technical specifications. Baths from Essencia collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models. FLOOR 1500 LB (680 KG) BEDDING Before installing, ensure that the floor underneath the bath can support 1500 lb (680 kg). The bath may sit directly on the floor. The bathtub can also sit on a concrete bed. In that case, it is recommended to isolate the concrete between two plastic sheets: one installed on the floor and the other under the bath. SERVICE ACCESS AND VENTILATION A service access is necessary. Minimum dimensions are 22 in. x 18 in. (55 cm x 46 cm) to properly reach all electrical components of the system. An air vent is necessary. Minimum dimensions are: 2 in. x 4 in. (5 cm x 10 cm) to ensure proper functioning of the turbine. There is a technical specification sheet for each BainUltra ThermoMasseur which includes information such as necessary dimensions of site before installation. If you do not already have the technical specifications, download from the BainUltra Web site at: bainultra.com or call us at: 1 800 463-2187. 6 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH PLUMBING FLOOR LAYOUT FOR PIPES AND ACCESS ESSENCIA 6838 68" Air pipe Floor anchor 6" Standard waste & overflow INTEGRATED waste & overflow 38" 12" Floor anchor 25,125" Wiring 10" 14,5" Access trap 25,125" ESSENCIA OVAL 7236 72" Wiring 4,5" Overflow Waste Floor anchor Floor anchor 36" 10,5" Air pipe Access 12" 19,5" 9,375" trap NOTE : Please refer to the Installation Template provided with your ESSENCIA bath. However, if it is missing, please contact us at 1-800-463-2187 to order it. www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 7

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH PLUMBING FLOOR LAYOUT FOR PIPES AND ACCESS (cont d) ESSENCIA DESIGN 72" Wiring 2" Waste & Overflow Floor anchor Floor anchor 36" 11" Air pipe 19,5" 9,5" 9,375" Access trap NOTE : Please refer to the Installation Template provided with your ESSENCIA bath. However, if it is missing, please contact us at 1-800-463-2187 to order it. 1 PLUMBING - ESSENCIA 6838 HELPFUL TIP: Carefully place the tub on its side, on a blanket or a corrugated cardboard. Measure & Align (2x) Floor anchor R 8 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH STANDARD PARTS - PLUMBING ESSENCIA 6838 DESCRIPTION QTY A Plated drain clicker 1 B Locking nut 1 D C Strainer 1 D Rubber seal 1 E PVC Wired drain shoe 1 F PVC Piping 1-1/2 X 2 1 G PVC Tee Connector 1-1/2 F-F 1 Flexible Overflow Piping (Factory installed) G F E If necessary adjust length of the flexible overflow piping connected to the overflow. OPTIONNAL PARTS - PLUMBING (1) ESSENCIA 6838 DESCRIPTION QTY H Plated drain clicker 1 I Strainer 1 J Rubber seal 1 K Brass drain shoe 1 L 4 in. brass tailpiece 1 Flexible Overflow Piping (Factory installed) J M Nylon conic shaped seal for drain 1 K N Brass nut 2 O Brass pipe 1-1/2 x 3 with flange 1 L P Nylon flat seal with flange 1 Q P O N M Q 1-1/2 male threaded adaptor 1 (1) : INTEGRATED WASTE & OVERFLOW OPTION www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 9

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 1 PLUMBING - ESSENCIA OVAL 7236 HELPFUL TIP: Carefully place the tub on its side, on a blanket or a corrugated cardboard. S Threaded anchor Measure & Align (2x) STANDARD PARTS - PLUMBING ESSENCIA OVAL 7236 DESCRIPTION QTY A Plated drain clicker (p. 3) 1 B Locking nut (p. 3) 1 C Strainer (p. 3) 1 D Rubber seal 1 E PVC Wired drain shoe 1 F PVC Piping 1-1/2 X 2 1 If necessary adjust length of the flexible overflow piping connected to the overflow. Adjust length on the straight part of the brass overflow pipe «F» to fit with the drain position that varies with different bath models. Fix anchors «S» to floor with the provided screws «V» (p. 4). G PVC Tee Connector 1-1/2 F-F 1 D Flexible Overflow Piping (Factory installed) G F E 10 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 1 PLUMBING - ESSENCIA DESIGN HELPFUL TIP: Carefully place the tub on its side, on a blanket or a corrugated cardboard. Threaded anchor S Fix anchors «S» to floor with the provided screws «V» (p. 4). Measure & Align (2x) STANDARD PARTS - PLUMBING ESSENCIA DESIGN DESCRIPTION QTY H Plated drain clicker (p. 3) 1 I Strainer (p. 3) 1 J Rubber seal 1 K Brass drain shoe 1 L 4 in. brass tailpiece 1 M Nylon conic shaped seal for drain 1 N Brass nut 2 O Brass pipe 1-1/2 x 3 with flange 1 P Nylon flat seal with flange 1 Q 1-1/2 male threaded adaptor 1 Flexible Overflow Piping (Factory installed) J K Q P O N M L www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 11

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 2 TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR ) Geysair Hose and Back Flow Preventer 1-1/2 I.D. PVC AIR INTAKE PIPE («TIGERFLEX» FLEXIBLE PVC) 1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX») & Fittings (not included) Hot Water Supply TURBINE REMOTE MOUNTING SEE STEP 7 page 17 Access to Geysair TM backflow preventer is necessary for cleaning of the filter. Baths from Essencia collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models. Geysair component cannot be remote mounted. It must stay at original position, attached to bath. Must never be unplugged. 3 ELECTRICAL WIRING OF OPTIONAL COMPONENTS REMOTE MOUNTING of CONTROL MODULES SEE STEP 8 page 18 12 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

PARTS REMOTE & TOOLS MOUNTING REQUIRED OF TURBINE WITH ACCESS UNDER BATH 4 BATH INSTALLATION - ESSENCIA 6838 HELPFUL TIPS: Carefully place the tub on its side, on a blanket or a corrugated cardboard. To easily manipulate the bathtub in a safe way during installation, we recommend using moving straps. Floor anchor R Measure & Align (2x) Be sure the floor is leveled. Use shims as needed. Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic. Apply a bead of silicone around the perimeter of the bath. The tub must be securely anchored to floor. Install the bath on anchors «R» previously screwed to floor. Remove exceeding silicone. Floor surface 4 Minimum Anchor R www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 13

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 4 BATH INSTALLATION - ESSENCIA OVAL 7236 & DESIGN HELPFUL TIPS: Carefully place the tub on its side, on a blanket or a corrugated cardboard. To easily manipulate the bathtub in a safe way during installation, we recommend using moving straps. Measure & Align (2x) Threaded Anchor S Be sure the floor is leveled. Use shims as needed. Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic. Apply a bead of silicone around the perimeter of the bath once on the floor. The tub must be securely anchored to floor. Install the bath on anchors «S» previously screwed to floor. Remove exceeding silicone. Connect the drain. Attach bath to floor by screwing washers «U» and nuts «T» to anchors «S». Close with the seals «W». Floor surface 1 Maximum T U W S 14 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 5 ELECTRONIC CONTROL INSTALLATION MIAPLUS & MIAMULTI (OPTIONAL) LOCATION LOCATION: Determine the most convenient location, on the wall close to tub. Peel off the protective film of sticker behind the control. You can add a silicone bead to secure to the wall. Baths from Essencia collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models. DRILLING OF WALL: Refer to the Cutting Template on page 34 for the location and diameter of the holes. Jig saw with fine cut blade Drill TOOLS REQUIRED 1/4 in. drill bit TOUCH PAD INSTALLATION Push wiring through drilled holes. Remove protective film from watertight seal. Secure to the wall with permanent waterproof sealant (mold-free clear silicone for bathrooms). Secure temporarily with a tape for about 24 h. 5 ELECTRONIC CONTROL INSTALLATION DOT TOOLS REQUIRED 7/8 in. Hole saw Drill TOUCH PAD INSTALLATION Push wiring through drilled holes. DOT WarmTouchShell (WTS) Remove protective film from watertight seal. Secure to the wall with permanent waterproof sealant (mold-free clear silicone for bathrooms). Secure temporarily with a tape for about 24 h. DOT Chromatherapy (LED) If the control is not factory installed, you will find it attached to the turbine, or to the electronic control modules. www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 15

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 6 REMOTE MOUNTING OF TURBINE Bottom of door When located in an enclosed location. 1 Floor Choose a location for the turbine with the shortest possible distance from the Thermomasseur bath, no more than 15 ft. (4,6m), and a maximum of six elbow directional changes to ensure system performance. It can be under the floor, in a closet or any other place that can hide the turbine and if needed optional modules. Easy access must remain possible at all time and sufficient air ventilation is necessary for turbine. A service access is necessary. Minimum dimensions are 22 in. x 18 in. (55 cm x 46 cm) to properly reach all electrical components of the system. An air vent is necessary. Minimum dimensions are: 2 in. x 4 in. (5 cm x 10 cm) to ensure proper functioning of the turbine. Geysair TM cannot be remotely installed. 16 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 7 REMOTE MOUNTING OF TURBINE - AIR PIPE (THERMOMASSEUR ) 1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX») & Fittings (not included) 7 REMOTE MOUNTING OF TURBINE - ELECTRICAL CONNECTIONS (THERMOMASSEUR ) See page 20 for electrical diagram GEYSAIR (option) EXTENSION CORD (If required for longer distance, contact BainUltra for ordering) GEYSAIR CONNECTION TO GFCI Outlet United States Junction box Canada For Geysair TM equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be tested between the bath grounding terminal and the bath power supply. Failure to perform the grounding continuity test could result in serious personal injury. www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 17

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 8 REMOTE MOUNTING OF TURBINE ELECTRICAL CONNECTIONS OF OPTIONAL THERAPIES See page 20 for electrical diagram. Match the colors of the plug-in cables with those of the turbine terminals E A: 2 nd Heated Backrest B: Chromatherapy (LED) D C: MiaPlus D: MiaMulti (Option) C E : AromaCloud A B Junction box Canada TO GFCI Outlet United States Junction box Canada TO GFCI Outlet United States Electrical outlet must be installed by a certified electrician. Installation must be conducted in accordance with all local, provincial/state, and federal building/electrical codes and regulation. Connect electrical supply only after all low voltage wiring is properly installed on turbine. If you did not follow this last step, shut off and then restart your home s circuit breaker. Turbine and air pipe should be clear of building materials and wiring. 18 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 8 REMOTE MOUNTING OF OPTIONAL THERAPIES (TUB ONLY) ELECTRICAL CONNECTIONS See page 21 for electrical diagram. A : WarmTouchShell B: Chromatherapy (LED) C : DOT WarmTouchShell D : DOT Chromathérapie E : AromaCloud D B A C E C DOT WarmTouchShell (WTS) D Junction box Canada TO GFCI Outlet United States Junction box Canada TO GFCI Outlet United States DOT Chromothérapie (DEL) www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 19

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH ELECTRICAL DIAGRAM THERMOMASSEUR 20A CIRCUIT 15A CIRCUIT NEUTRAL N L LOAD NEUTRAL N L LOAD GROUND FAULT CIRCUIT INTERRUPTERS GROUND FAULT CIRCUIT INTERRUPTERS JUNCTION BOX JUNCTION BOX N L N L TURBINE WITH GEYSAIR (FOR MIAPLUS, MIAMULTI ) TURBINE WITHOUT GEYSAIR (FOR MIAPLUS, MIAMULTI ) 20 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH ELECTRICAL DIAGRAM - THERAPIES 15A CIRCUIT NEUTRAL N L LOAD GROUND FAULT CIRCUIT INTERRUPTERS JUNCTION BOX N L N L N L AROMACLOUD (AROMATHERAPY) INMIX MODULE (CHROMATHERAPY) AIRSTREME (WARMTOUCHSHELL ) www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 21

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 1 PLUMBING FLOOR LAYOUT FOR PIPES AND ACCESS 68" Air pipe Floor anchor 6" Standard waste & overflow INTEGRATED waste & overflow 38" 12" Floor anchor Wiring 10" Access trap 25,125" 14,5" 25,125" ESSENCIA 6838 - STANDARD WASTE INSTALLATION 68" 5,625" INTEGRATED waste & overflow 38" Opening for the Island Tub Drain Ø6,5" ESSENCIA 6838 ISLAND TUB DRAIN INSTALLATION (INTEGRATED OVERFLOW option ONLY) NOTE : Please refer to the Installation Template provided with your ESSENCIA bath. However, if it is missing, please contact us at 1-800-463-2187 to order it. 22 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE PARTS & TOOLS MOUNTING REQUIRED OF TURBINE WITHOUT ACCESS UNDER BATH 1 PLUMBING FLOOR LAYOUT FOR PIPES AND ACCESS (cont d) 72" Wiring 4,5" Overflow Waste Floor anchor Floor anchor 36" 10,5" Air pipe Access 12" 19,5" 9,375" trap ESSENCIA OVAL 7236 - STANDARD WASTE INSTALLATION 41,5" 72" 36" Opening for the Island Tub Drain Ø6,5" 5,5" ESSENCIA DESIGN ISLAND TUB DRAIN INSTALLATION NOTE : Please refer to the Installation Template provided with your ESSENCIA bath. However, if it is missing, please contact us at 1-800-463-2187 to order it. www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 23

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 1 PLUMBING - ESSENCIA 6838 STANDARD DRAIN INSTALLATION HELPFUL TIP: Anchor Carefully place the tub R on its side, on a blanket or a corrugated cardboard. Measure & Align (2x) STANDARD PARTS - PLUMBING ESSENCIA 6838 DESCRIPTION QTY A Plated drain clicker (p. 3) 1 B Locking nut (p. 3) 1 C Strainer (p. 3) 1 D Rubber seal 1 E PVC Wired drain shoe 1 F PVC Piping 1-1/2 X 2 1 G PVC Tee Connector 1-1/2 F-F 1 D Flexible Overflow Piping (Factory installed) If necessary adjust length of the flexible overflow piping connected to the overflow. G F E 24 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE PARTS & TOOLS MOUNTING REQUIRED OF TURBINE WITHOUT ACCESS UNDER BATH 1 PLUMBING - ESSENCIA 6838 ISLAND TUB DRAIN INSTALLATION (INTEGRATED DRAIN & OVERFLOW OPTION) HELPFUL TIP: Carefully place the tub on its side, on a blanket or a corrugated cardboard. Anchor R Refer to supplied instructions for Island Tub Drain installation. Island Tub Drain Measure & Align (2x) OPTIONAL PARTS - PLUMBING (1) ESSENCIA 6838 DESCRIPTION QTY H Plated drain clicker 1 I Strainer 1 J Rubber seal 1 K Brass drain shoe 1 L 4 in. brass tailpiece 1 M Nylon conic shaped seal for drain 1 N Brass nut 2 O Brass pipe 1-1/2 x 3 with flange 1 P Nylon flat seal with flange 1 Q 1-1/2 male threaded adaptor 1 (1): INTEGRATED DRAIN & OVERFLOW OPTION Flexible Overflow Piping (Factory installed) J K Q P O N M L www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 25

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 1 PLUMBING - ESSENCIA OVAL 7236 STANDARD DRAIN INSTALLATION HELPFUL TIP: Carefully place the tub on its side, on a blanket or a corrugated cardboard. Measure & Align (2x) Threaded Anchor S STANDARD PARTS - PLUMBING ESSENCIA OVAL 7236 DESCRIPTION QTY A Plated drain clicker (p. 3) 1 B Locking nut (p. 3) 1 C Strainer (p. 3) 1 D Rubber seal 1 E PVC Wired drain shoe 1 If necessary adjust length of the flexible overflow piping connected to the overflow. Adjust length on the straight part of the brass overflow pipe «F» to fit with the drain position that varies with different bath models. Fix anchors «S» to floor with the provided screws «V» (p. 4). F PVC Piping 1-1/2 X 2 1 G PVC Tee Connector 1-1/2 F-F 1 D Flexible Overflow Piping (Factory installed) G F E 26 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 1 PLUMBING - ESSENCIA DESIGN ISLAND TUB DRAIN INSTALLATION HELPFUL TIP: Carefully place the tub on its side, on a blanket or a corrugated cardboard. Threaded Anchor S Measure & Align (2x) Refer to supplied instructions for Island Tub Drain installation. Island Tub Drain STANDARD PARTS - PLUMBING (1) ESSENCIA DESIGN DESCRIPTION QTY H Plated drain clicker 1 I Strainer 1 Fix anchors «S» to floor with the provided screws «V» (p. 4). J Rubber seal 1 K Brass drain shoe 1 L 4 in. brass tailpiece 1 M Nylon conic shaped seal for drain 1 N Brass nut 2 O Brass pipe 1-1/2 x 3 with flange 1 P Nylon flat seal with flange 1 Q 1-1/2 male threaded adaptor 1 (1) : INTEGRATED DRAIN & OVERFLOW OPTION J K Flexible Overflow Piping (Factory installed) Q P O N M L www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 27

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 2 TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR ) PASSAGE FOR THE ELECTRICAL WIRING OF OPTIONAL THERAPIES IF THE AIR PIPING CONNECTIONS AND POWER SUPPLY OF THERAPEUTIC OPTIONS HAVE TO BE AT FLOOR LEVEL, YOU MUST MAKE AN OPENING ON ONE SIDE OF THE BATH, AS CLOSE AS POSSIBLE TO TURBINE AND CONTROLS. Do not drill through the interior shell. The size of the opening must be large enough to allow wires and pipes to go through. TOOLS REQUIRED Drill 1/4 in. drill bit Jig saw with fine cut blade ESSENCIA 6838 Air pipe* Geysair (optional) Electric cables (Optional therapies) ESSENCIA Oval 7236 & DESIGN Air pipe* Geysair (optional) Electric cables (Optional therapies) (*) : Location of air pipe can differ from drawing. 28 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 2 TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR ) Geysair Hose and Back Flow Preventer 1-1/2 I.D. PVC AIR INTAKE PIPE («TIGERFLEX» FLEXIBLE PVC) 1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX») & Fittings (not included) Hot Water Supply TURBINE REMOTE MOUNTING SEE STEP 7 page 17 Access to Geysair TM backflow preventer is necessary for cleaning of the filter. Baths from Essencia collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models. Geysair component cannot be remote mounted. It must stay at original position, attached to bath. Must never be unplugged. 3 ELECTRICAL WIRING OF OPTIONAL COMPONENTS REMOTE MOUNTING of CONTROL MODULES SEE STEP 8 page 18 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 29

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 4 BATH INSTALLATION - ESSENCIA 6838 WITH STANDARD DRAIN...13 4 BATH INSTALLATION - ESSENCIA 6838 WITH ISLAND TUB DRAIN (INTEGRATED OVERFLOW OPTION ONLY) HELPFUL TIPS: Carefully place the tub on its side, on a blanket or a corrugated cardboard. To easily manipulate the bathtub in a safe way during installation, we recommend using moving straps. Anchor R Measure & Align (2x) Be sure the floor is leveled. Use shims as needed. Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic. Apply a bead of silicone around the perimeter of the bath once on the floor. Connect the drain. Install bath on anchors «R» previously screwed to the floor. Remove exceeding silicone. R 30 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 4 BATH INSTALLATION - ESSENCIA OVAL 7236 WITH STANDARD DRAIN...14 4 BATH INSTALLATION : ESSENCIA DESIGN WITH ISLAND TUB DRAIN HELPFUL TIPS: Carefully place the tub on its side, on a blanket or a corrugated cardboard. To easily manipulate the bathtub in a safe way during installation, we recommend using moving straps. Threaded anchor S Measure & Align (2x) Be sure the floor is leveled. Use shims as needed. Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic. Apply a bead of silicone around the perimeter of the bath. Connect the drain. Install bath on anchors «S» previously screwed to the floor. Remove exceeding silicone. Attach the bath to floor with washers «U» and nuts «T» screwed to anchors «S». Cover with seals «W». T U W Threaded anchor S S www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 31

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 4 BATH INSTALLATION DRAIN CONNECTION WITH ISLAND TUB DRAIN (ITD) - INFORMATION Refer to supplied instructions for ISLAND TUB DRAIN installation. ISLAND TUB DRAIN Floor surface Use the 6 in. (15 cm) tail piece supplied with Island Tub Drain 32 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH FOR THE NEXT STEPS, SEE SECTION : REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER THE BATH 5 ELECTRONIC CONTROL INSTALLATION MIAPLUS & MIAMULTI (6838 & OVAL 7236)...15 5 ELECTRONIC CONTROL INSTALLATION DOT (THERAPIES)...15 6 REMOTE MOUNTING OF TURBINE...16 7 REMOTE MOUNTING OF TURBINE AIR PIPE (THERMOMASSEUR )...17 7 REMOTE MOUNTING OF TURBINE ELECTRICAL CONNECTIONS (THERMOMASSEUR )...17 8 REMOTE MOUNTING OF TURBINE ELECTRICAL CONNECTIONS OF OPTIONAL THERAPIES...18 8 REMOTE MOUNTING OF OPTIONAL THERAPIES (TUB ONLY) ELECTRICAL CONNECTIONS...19 ELECTRICAL DIAGRAM THERMOMASSEUR...20 ELECTRICAL DIAGRAM THERAPIES...21 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 33

NOKORI CUTTING TEMPLATES / GABARITS DE PERÇAGE NOKORI CUTTING TEMPLATES / GABARITS DE PERÇAGE Print scale 100% / Imprimer à 100% Print scale 100% / Imprimer à 100% Cut-out for MiaMulti infrared Trou pour infrarouge MiaMulti 5.125"±0.04" [13.0 cm±0.1 cm] 1.625" [4.1 cm] 0.875" [2.2 cm] 1.125" [2.9 cm] 1.625"±0.04" [4.1 cm±0.1 cm] MIAPLUS & MIAMULTI 2.165" [5.5 cm] 1.375" [3.5 cm] R0.125" [R0.3 cm] 5.591" [14.2 cm] Control cut-out Trou du contrôle Control outline Contour du contrôle R0.250" [R0.6 cm] Print scale 100% / Imprimer à 100% 1.063" [2.7 cm] 11.313" [28.7 cm] AIR INTAKE - OPENING PRISE D'AIR - OUVERTURE 11.063" [28.1 cm] 0.813" [2.1 cm] R0.125" [R0.3 cm] CUTTING TEMPLATEs / GABARITS DE PERÇAGE 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST). Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright August 2016 BainUltra Inc. All rights reserved. 45200640 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 34